Housing Urban and Rular Development Government Departments Closing in 13 days TDR #58510793

Tender For Special Repairs To Leaky Roof, Toilet, Water Supply, Sanitary And Painting Arrangements At Phc At Ct Palayam At Anthiyur Taluk Of Erode District

Issued by Government Departments · Erode, Tamil Nadu
Tender Value
12.84 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
13 days left
EMD
13000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Erode → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Leaky Roof, Toilet, Water Supply, Sanitary And Painting Arrangements At Phc At Ct Palayam At Anthiyur Taluk Of Erode District

BOQ

Name of Work:- Special repairs to Leaky roof, Toilet, Water supply, Sanitary and Painting arrangements at PHC at CT Palayam at Anthiyur Taluk of Erode District
Sl. No. Item Description
1Dismantling clearing away and carefully stacking the materials useful for reuse of Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs etc., complete as per standard specification and as directed by the deparmental officers.
2Dismantling clearing away and carefully stacking materials useful for reuse of Brick / stone masonry in Cement mortar walls under 3m high etc, complete as per standard specification and as directed by the deparmental officers.
3Dismantling, Clearing away and carefully stacking the materials useful for reuse of RCC by manual / by using deploying machineries etc, complete complying with standard specifications and as directed by the deparmental officers.
4Clean removal of cement plaster from walls etc.,complete complying with standard specification and as directed by the departmental officers.
5Clean removal of cement plaster from walls and racking out joints 20mm deep for ceiling etc., complete complying with standard specification and as directed by the departmental officers.
6Dismantling and carefully stacking the materials useful for reuse of Pressed tiles & weathering course, etc., complete as per standard specification and as directed by the deparmental officers.
7Dismantling clearing away and carefully stacking the materials useful for reuse of One course of pressed tile roof finish in Cement Mortar etc., complete as per standard specification and as directed by the deparmental officers.
8Dismantling clearing away and carefully stacking the materials useful for reuse of Plain Cement Concrete etc, complete as per standard specification and as directed by the deparmental officers.
9Earth work excavation for foundation by manual means for RR/Brick and Other step type footings for Load bearing structures in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
10Cement Concrete 1:5:10 (One Cement, Five Crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification-Mixing by manual means
11Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
12Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
13Brick work in Cement Mortar 1:6 (one cement and six crushed stone sand) using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge.
14For Foundation and Basement
15For Super Structure in Ground Floor
16Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) For Super Structure in Ground Floor
17Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
18Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick), etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
19Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
20Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
21For Foundation and Basement
22For Super Structure in Ground Floor
23Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)Upto Plinth / Basement level
24Cement Concrete 1:5:10 (One Cement, Five Crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification-Mixing by manual means
25Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.Super Structure in Ground floor
26Finishing the top of roof with one course of New machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. Using Pressed Tiles of 230mm x 230mm x 16 mm to 18mm
27Finishing the top of roof with one course of Old machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. Using Pressed Tiles of 230mm x 230mm x 16 mm to 18mm
28Cleaning the Roof top pressed tiles with High pressure water wash by Machine cleaning. Applying Polymer/Weedicides chemical spray on the top of the roof. Pointing the joints neatly to full depth of tiles. Applying Two Layers of CeraBond Fiber material and top coating with two coats of Electrocoat Rubberized material etc., completely as per specification.
29Flooring with Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
30Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Double charged Vitrified Tiles 600 x 600 x 8mm
31Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm
32Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) - 20 mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
33Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) 25 mm thick
34Supplying and fixing in position steel balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete. An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers.
35Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers
36Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
37Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
38Supplying and fixing position CI Nahani Trap / Floor Trap of the size 75 x 50mm with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
39Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
40110mm dia PVC Pipe
4175mm dia PVC Pipe
42Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
43110 mm dia PVC Elbow with door
4475mm dia PVC Elbow with door
45Manufacturing, supplying and fixing 1/3 panelled and 2/3 grilled steel doors with the following specification M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S.flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sand witching the CR sheet in between.Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 20kg/sq.m, 3 Nos Steel Parliament Hinges of Size 125mm x 150mm incase single leaves shutter to be provided and 6 Nos Steel Parliament Hinges of Size 125mm x 150mm for double leaves shutter to be provided 6nos of holdfasts 200mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 4nos. One the top of each shutter, one at lock rail (Inner side) and the other at the bottom are provided. one aldrop is provided at on appropriate place in the door.3 Nos of handle are to be provided, A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation or fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour ,charges, taxes, ransportation to site of work, loading, unloading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Double leaf of size 1.20m x 2.10m
46Renewing the damaged galss panes with new 3mm thick pin headded galss panes including cost of alround teakwood beading etc., complete complying with standard specification and as directed by the departmental officers.
47Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/-1mm) & minimum Bulk Density of 550 KG/ cub.Mt. & shore Hardness of 55. For the aesthetic appearance, the door Shall be a printed digitally on the side of the shutter and the design is as decided by the Engineer in Charge of the departmental. The WPC door shall be fixed onto the WPC frame with 3 Nos of 5\\" SS Hinges and the door shall have 2 towerbolt on one side and 1 towerbolt or aldrop on the other side for locking system and 2 numbers of handle on the either side of the door shutter, all made of aluminium etc., complete and as directed by the departmental officers
48Supplying ,fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using 1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc... complete complying with standard specification and as directed by the departmental officers.
49Supplying and fixing solid core flush shutter of following type with thickness and necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf
50Fabricating, Supplying and fixing in position of steel Sheeted windows (Four Leaves) with the following specifications. Outer frames of windows made of ‘Z’ section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion ‘J’ section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made of F7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly. 2 numbers of Steel Offset Pivot hinges of size 3” and one number of handle-Cu.m-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adjustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 200mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete complying with standard specification and as directed by the departmental officers.
51Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers.
52Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
53Painting Old Plastered Wall Surface with Two finishing coats of Exterior Emulsion paint of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
54Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.
55Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with One coats of best approved first quality and colour of synthetic enamel paint over the existing priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
56Painting Old wood work with Two coat of synthetic enamel ready mixed paint of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
57Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm Colour glazed earthern ware of approved quality and brand with \\"P\\" or \\"S\\" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
58Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \\"P\\" or \\"S\\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
59Fabrication, supply and fixing in position of ‘N’ type ventilators using M.S. angle of size 25 x 25 x5 mm for frame and M.S. Flat of size 20 x 3 mm for fixing the weld mesh and using 25 x 22 x3 mm ‘T’ section for frame glass. Special type of Hold fast welded to the frame of 45 degree inclined towards centre for wall and fxing the weldmesh 25mm square including cost of 3mm thick pinheaded glass panes for all panels and fixing the glass panels with necessary clips & putties with required bolts, nuts and washers and one coat of red oxide primer etc. including necessary dismantling, making holes in RCC columns, beams, masonry wherever necessary with power drill to the extend required and made good to the original conditions after fising complete complying with standard specification and as directed by the departmental officers
60Construction of INSPECTION CHAMBER following clear sizes including earth work excavation,CC 1:5:10 of 10 cm thick and brick work in cement mortar 1:5 [One cement and five crushed stone sand] using best quality of Fly Ash Brick of size 230x110x70mm with class designation of 7.5 with plastering with cement mortar 1:3 [one cement and three crushed stone sand] 12mm thick to inner and outer sides and wearing coat 1:3:6 [One cement,three crushed stone sand and six aggregate] 15cm thick and covered with precast slab 5cm thick etc.,complete complying with standard specifications and as directed by the departmental officers.
61CLEAR SIZE 0.60m X0.60m
62CLEAR SIZE 0.90m X0.90m
63Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Below ground level.
6432 mm diametre UPVC PIPE - Below Ground Level
6525 mm diametre UPVC PIPE - Above Ground Level
66Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level.20 mm diametre UPVC PIPE..
67Supplying, laying and jointing UPVC Specials (Unplasticized polyvinyl chloride) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (both in internal and external water supply arrangements)Note:Since the labour for cutting,threading/pasting,sundries have already been included under pipe line item of works,no separate provision for fixing UPVC specials needs to be allowed.
6825 mm dia UPVC Elbow
6925 mm dia UPVC Tee
7025 mm dia UPVC Coupling
7120 mm dia UPVC Elbow
7220 mm dia UPVC Tee
7325 x 20 mm dia UPVC Reducer
7420 x 15 mm dia UPVC Reducer
75Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
7632mm G.M. Gate Valve
7725 mm G.M. Gate Valve
78Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers.(110 mm dia PVC Pipe)
79Supplying and fixing colour galvalume sheet roof of 0.47mm thick and steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
80Supplying & fixing of PVC ready made water tank of 1000 litre capacity best quality and the approved variety of I.S.I specifications with necessary inlets and the outlets and overflow, cleaning pipe arrangements and labour charge for fixing in position etc., and properly fixed in the floor top as directed by the departmental officers.
81Paving the floor with fine polished cuddapah stone slab of following thickness over cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer and pointing the joints to full depth of slabs with same mortar mixed with black oxide and the top surface rendered smooth, curing, etc.,complete complying with standard speicification and as directed by the departmental officers. (The cuddapah stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) Cuddapah Slab of 20 / 30mm thick
82GST 18% Including GST 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58510793
AUTHORITY Government Departments
TENDER VALUE 12.84 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Special Repairs To Leaky Roof, Toilet, Water Supply, Sanitary And Painting Arrangements At Phc At Ct Palayam At Anthiyur Taluk Of Erode District
Basic Detail
Tender No NIT.15 2026 27 BCM DIVISION ERODE Dated.11.11.2026
Bidding Type Tender
Location
City Erode
State Tamil Nadu
Key Dates
Publish Date 13 Nov 2026
Submission Date 30 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 12.84 Lakhs
Tender Fee Ref. Documents
EMD 13000
Exemption Not Available
Document List
91668c7c-51ac-4334-bf93-586e7e00f96a.html
BOQ_871272.xls
Tencon_CTpalayamPHC.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

91668c7c-51ac-4334-bf93-586e7e00f96a.html

xls

BOQ_871272.xls

pdf

Tencon_CTpalayamPHC.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender