Tender For Improvement Of Existing Water Supply System In Cumbum Municipality,,Theni District Under Cmiudm 2026-2027
Tender Value
42.19 Crore
Estimated cost
Bid Submission
15 Dec 2026
28 days left
EMD
42.19 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Theni → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of Existing Water Supply System In Cumbum Municipality,,Theni District Under Cmiudm 2026-2027
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m below on linear measurement Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam following types of soil strata as directed by departmental officers.Hard stiff clay, stiff black cotton, hard red earth,shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil.SS20B |
| 2 | Upto 2.0 m depth |
| 3 | 110,140,160,180,200,225mm Dia HDPE pipe,250,300,350 mm Dia DI Pipe & 80,100mm Dia GI pipe . |
| 4 | OHT & WATCH MAN SHED |
| 5 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth.(DATA) |
| 6 | 1)For 1st depth of 0 m to 2.4 m |
| 7 | 2)For 2nd depth of 2.4 m to 3.4 m |
| 8 | Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge |
| 9 | 110,140,160,180,200,225mm Dia HDPE pipe,250,300,350 mm Dia DI Pipe & 80,100mm Dia GI pipe.as directed by the TWAD Officers. |
| 10 | Supply & delivery of following sizes of HDPE PIPES confirming to as directed by the TWAD Officers. |
| 11 | 110mm Dia HDPE pipe |
| 12 | 140mm Dia HDPE pipe |
| 13 | 160mm Dia HDPE pipe |
| 14 | 180mm Dia HDPE pipe |
| 15 | 200mm Dia HDPE pipe |
| 16 | 225mm Dia HDPE pipe |
| 17 | Supply & delivery of following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES AS PER IS 8329/2000 (TWAD SOR 25-26 PG.NO-211) |
| 18 | 250mm Dia DI/P |
| 19 | 300mm Dia DI/P |
| 20 | 350mm Dia DI/P |
| 21 | Supply & delivery of following sizes of G I PIPES (MEDIUM) AS PER IS 1239/PART I/2004 |
| 22 | 80 mm Dia GI/P |
| 23 | 100 mm Dia GI/P |
| 24 | Lowering HDPE pipes and specials to trench and laying to proper grade and alignment and as directed by the Dept Officers. |
| 25 | 110mm Dia HDPE pipe |
| 26 | 140mm & 160mm Dia HDPE pipe |
| 27 | 180mm,200mm&225mm Dia HDPE pipe |
| 28 | Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers. |
| 29 | 250mm Dia DI/P |
| 30 | 300mm Dia DI/P |
| 31 | 350mm Dia DI/P |
| 32 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers (TWAD SOR 25-26 PG.NO-181) |
| 33 | 80 mm to 100mm Dia GI/P (WD-W0262) |
| 34 | Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Dept Board Officers. (TWAD SOR 25-26 PG.NO-181) |
| 35 | 110mm Dia HDPE pipe (WD-W0619) |
| 36 | 140mm Dia HDPE pipe (WD-W0621) |
| 37 | 160mm Dia HDPE pipe (WD-W0622) |
| 38 | 180mm Dia HDPE pipe (WD-W0623) |
| 39 | 200mm Dia HDPE pipe (WD-W0624) |
| 40 | 225mm Dia HDPE pipe (WD-W0625) |
| 41 | Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials) .(TWAD SOR 25-26 PG.NO-196) |
| 42 | 250mm Dia DI/P (WD-W0312) |
| 43 | 300mm Dia DI/P (WD-W0313) |
| 44 | 350mm Dia DI/P (WD-W0314) |
| 45 | Cutting P.V.C./HDPE rigid pipes and specials true to axis and finishing the ends complete. (TWAD SOR 25-26 PG.NO-184) |
| 46 | 110mm Dia HDPE pipe (WD-W0512) |
| 47 | 160mm Dia HDPE pipe (WD-W0516) |
| 48 | 180mm& 2000 mm Dia HDPE pipe (WD-W0517) |
| 49 | 225mm Dia HDPE pipe (WD-W0519)(Adopt 250mm dia) |
| 50 | Cutting C.I./D.I Pipes true to axis and filing smoothly and finishing the ends complete (TWAD SOR 25-26 PG.NO-195) |
| 51 | 250mm Dia DI/P (WD-W0482) |
| 52 | 300mm Dia DI/P (WD-W0483) |
| 53 | 350mm Dia DI/P (WD-W0484) |
| 54 | 80mm dia GI/P (84.39+39.08+84.39)(W-0137,W-0138) |
| 55 | 100mm Dia GI/P-(W-0139,W-0140)(55.74+112.42+112.42) |
| 56 | Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by Dept officers.(TWAD SOR 25-26 PG.NO-232) (WD-W0936) |
| 57 | Barricading work (Where the lines are in narrow width of municipality area,busy streets like Market, Bus-stand and in the Highways etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia.and 1.80m height) vertical with horizontal poles in two rows, painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.140mm Dia HDPE pipem x 0.8mm thick) in the horizontal poles and fixing 75mm dia. reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by Dept officers.(TWAD SOR 25-26 PG.NO-233) (WD-W0937) |
| 58 | Testing of pipes for water supply with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes.(TWAD SOR 25-26 PG.NO-194) |
| 59 | 110mm Dia HDPE pipe (WD-W0460) |
| 60 | 140mm Dia HDPE pipe (WD-W0461) |
| 61 | 160mm&180mm Dia HDPE pipe (WD-W0462) |
| 62 | 200mm & 225mm Dia HDPE pipe (WD-W0463) |
| 63 | 250mm Dia DI/P (WD-W0464) |
| 64 | 300mm Dia DI/P (WD-W0465) |
| 65 | 350mm Dia DI/P (WD-W0466) |
| 66 | Supply , delivery and fixing of HDPE specials (lining and coated) at site etc., complete as directed by Engineer in charge.(TWAD SOR 25-26 PG.NO- 20 &11) |
| 67 | 110mm Dia HDPE pipe-90 Deg Bend (WD-M0286) |
| 68 | 140mm Dia HDPE pipe-90 Deg Bend (WD-M0288) |
| 69 | 160mm Dia HDPE pipe-90 Deg Bend (WD-M0289) |
| 70 | 180mm Dia HDPE pipe-90 Deg Bend (WD-M0290) |
| 71 | 200mm Dia HDPE pipe-90 Deg Bend (WD-M0291) |
| 72 | 225mm Dia HDPE pipe-90 Deg Bend (WD-M0292) |
| 73 | 110mm Dia HDPE pipe-Tee (WD-M0286) |
| 74 | 140mm Dia HDPE pipe-Tee (WD-M0288) |
| 75 | 160mm Dia HDPE pipe-Tee (WD-M0289) |
| 76 | 180mm Dia HDPE pipe-Tee (WD-M0290) |
| 77 | 200mm Dia HDPE pipe-Tee (WD-M0291) |
| 78 | 225mm Dia HDPE pipe-Tee (WD-M0292) |
| 79 | Supply , delivery and fixing of End Cap (WD-M0115) |
| 80 | Supply & delivery of following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 AS PER IS 8329/2000 .(TWAD SOR 25-26 PG.NO- 46) |
| 81 | 250mm D.I. 90 Deg Bend,45 Deg bend,300mm 90 Deg & 45 Deg bend (WD-M0779) |
| 82 | 350mm D.I. 90 Deg Bend & 45 Deg bend (WD-M0780) |
| 83 | Supply & delivery of following sizes of G.I. SPECIALS AS PER IS 1239/ PART II (TWAD SOR 25-26 PG.NO- 30 &36) |
| 84 | GI/P Reducer |
| 85 | 100mm x80mm GI Reducer (WD-M0525) |
| 86 | 100mm GI 90deg Elbow (WD-M0594) |
| 87 | 80mm GI Elbow (WD-M0594) |
| 88 | 100mm GI Coupling (WD-M0596) |
| 89 | 80mm GI Coupling (WD-M0596) |
| 90 | 100mm GI (WD-M0492) |
| 91 | G.I UNEQUAL TEE(MEDIUM) (TWAD SOR 25-26 PG.NO- 16) |
| 92 | 80mm GI Equal Tee (WD-M0595) |
| 93 | 80mm GI Dummy (WD-M0613) |
| 94 | 100mm Equal Tee (WD-M0595) |
| 95 | 100x80 mm Tee (WD-M0548) |
| 96 | 100mm GI Dummy (WD-M0163) |
| 97 | Disposal of surplus earth including loading, conveyance within a distance of 5 km and spreading as directed by the Engineer in charge.(TWAD SOR 25-26 PG.NO-231) |
| 98 | Net quantity (WD-W0930) |
| 99 | Supply and delivery of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron ofGrade GGG 40 or equivalent grade, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 ORing protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 4846-200mm Dia HDPE pipe0/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 (TWAD SOR 25-26 PG.NO-68) |
| 100 | 100mm DI D/F Gate Valve-110mm dia pipe (WD-M1199) |
| 101 | 150mm DI D/F Gate Valve-160mm Dia Pipe (WD-M1200) |
| 102 | 200mm DI D/F Gate Valve-180mm & 200mm dia pipe (WD-M1201) |
| 103 | Construction of Sluice DMA Chamber of size of 3.4mx1.5mx1.7m with earth work,supply M-sand,RCC mix M-20 grade of concrete,fabrication of Steel,Steel centring with RCC Slab 100 mm thick including cost and conveyance of all materials and labour charges to site etc., complete as per Standard specification. |
| 104 | DMA CHAMBER |
| 105 | Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.(TWAD SOR 25-26 PG.NO-97) |
| 106 | 100mm EFM-110 mm Dia Pipe (WD-M1391) |
| 107 | 125mm EFM-140mm dia pipe (WD-M1392) |
| 108 | 150mm EFM-160mm & 180mm dia pipe (WD-M1393) |
| 109 | 200mm EFM-200mm dia pipe (WD-M1394) |
| 110 | DI Pressure Reducing Valve (PN10/16) with the function to reduce downstream pressure to set point irrespective of upstream fluctuations.The downstream pressure set point can be changed as per the requirement.“Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing valve with cast body of ductile iron grade GGG-40 or GGG-50 or as per IS 3896 Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flage connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified(harmless)/WRAS & NSF approved.The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.”Pilot valve system having Stainless Steel / Brass fittings with spring of SS 304 as per standard parts according to DIN EN 12 266-1 with all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self-cleaning filter to avoid possibility of dirt build up inside the control tubing and with 5 years warranty.(TWAD SOR 25-26 PG.NO-85) |
| 111 | 100mm PRV-110mm dia Pipe (WD-M1306) |
| 112 | 150mm PRV -140mm Dia Pipe (WD-M1307) |
| 113 | 200mm PRV -250mm Dia Pipe (WD-M1308) |
| 114 | DI Altitude Control Valve (PN10/16) with the function to prevent water level in a tank from exceeding a set level. The set level can be changed as per the requirement.“Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Altitude Control valve with cast body of ductile iron grade GGG-40 or GGG-50 or as per IS 3896 Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. Flange connection dimensions according to EN 1092,Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270. (EP-P)/WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings as per standard parts according to DIN EN 12 266-1 with all the external control tubing of SS 304 / copper / reinforced plastic rated PN16 Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve / speed control device should be provided to vary opening speed of the main diaphragm with self-cleaning filter to avoid possibility of dirt build up inside the control tubing and with 5 years warranty |
| 115 | 100mm FVC-110mm dia Pipe (WD-M1256) |
| 116 | 150mm FVC-160mm & 180mm dia Pipe (WD-M1257) |
| 117 | 200mm FVC-200mm dia Pipe (WD-M1258) |
| 118 | Labour charges for cutting of B.T road or WBM roads for laying of mains and as directed by Engineer in charge.(TWAD SOR 25-26 PG.NO-215) |
| 119 | B.T. Roads (or) Maccadam road (WD-W0739) |
| 120 | Concrete Roads (WD-W0740) |
| 121 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means. |
| 122 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means |
| 123 | Supply and delivery of DI Specials for DMA CAHMBER valve including cost and conveyance of all materials and labour charges to site etc., complete as per Standard specification. |
| 124 | Labour for filling with fine sand passing through a sieve of ten meshes to 2.5cm and retained in a sieve of 40 meshes to 2.5 cm well washed and cleaned to be free from impurities including stacking.(TWAD SOR 25-26 PG.NO-203)(WD-W0612) |
| 125 | Labour for filling with broken stone of all sizes well washed and cleaned, to be free from impurities, including stacking and laying in bed.(TWAD SOR 25-26 PG.NO-203)(WD-W0610) |
| 126 | Labour for filling the coarse sand passing through a sieve of 10 meshes to 2.5 cm and retained in 20 meshes to 2.5 cm well washed and cleaned to be free from impurities including stacking Slow /Rapid Sand Filter).(TWAD SOR 25-26 PG.NO-203)(WD-W0611) |
| 127 | Supply delivery of natural pebbles filter media for filter bed operation & Sedimentary bore well of Spherical in shape and allow even distribution in support bed with good flow .The media should be doubled washed , Screened , Kiln dried and classified into various sizes to meet specifications including all incidents charges , loading & unloading etc.,as directed by the TWAD Board officers. (TWAD SOR 25-26 PG.NO-203) |
| 128 | SIZE : 20mm to 70mm (WD-W0935) |
| 129 | SIZE : 5mm to 20mm (WD-W0934) |
| 130 | Supply Fine sand media Top layer sand media including cost materials and Labour charges complete etc., (TWAD SOR 25-26 PG.NO-123)(WD-M1878) |
| 131 | Mosaic-in-situ finish in cement mortar in flooring and in wall surface (TWAD SOR V-I 25-26 PG.NO-31)(W-0041) |
| 132 | UGT/OHT (inside) waterproofing with Anti microbial Coating Waterproofing: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the UGT/ OHT tank applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/ mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti- algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification.(TWAD SOR 25-26 V-I PG.NO-44) (W-0306) |
| 133 | Plastering the surface of walls with Cement Mortar 1:4 (One cement and Four plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 134 | Supply and filling with M- sand in layers complying with standard specification including consolidation and watering etc. complete |
| 135 | Providing and laying in position, Standardised Concrete Mix M-30 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 136 | 1)Upto 1.5 m ht below G.L. |
| 137 | 2)Beyond 1.5 to 4.5m below GL |
| 138 | 3)Upto GL ht to 1.5 m Above G.L |
| 139 | 4)Upto 1.5 m ht to 4.5 m Above G.L |
| 140 | 3)Upto 4.5 m ht to 7.32 m Above G.L |
| 141 | 4)From 7.32 m to 10.98 m ht. Above G.L. |
| 142 | 5)10.98 m to 14.64 m ht. Above G.L. |
| 143 | 6)14.64 m to 18.30 m ht. Above G.L. |
| 144 | 7)18.30 m to 21.96 m ht. Above G.L. |
| 145 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 146 | Upto basement |
| 147 | Ground floor |
| 148 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 149 | Square Column |
| 150 | Watchmenshed |
| 151 | Up to Basement |
| 152 | 1)Column 0 to 3.6 m ht below GL&above GL |
| 153 | 3)Column from 3.6 m to4.90 m |
| 154 | 4)Column from 4.90 m to 5.90 m |
| 155 | 5)Column from 5.90 m to 6.90 m |
| 156 | 6)Column from 6.90 m to 7.90 m |
| 157 | 7)Column from 7.90 m to 8.90 m |
| 158 | 8)Column from 8.90 m to 9.90 m |
| 159 | 9)Column from 9.90 m to 10.90 m |
| 160 | 10)Column from 10.90 m to 11.90 m |
| 161 | 11)Column from 11.90 m to 12.90 m |
| 162 | 12)Column from 12.90 m to 13.90 m |
| 163 | 13)Column from 13.90 m to 14.90 m |
| 164 | 13)Column from 14.90 m to 15.90 m |
| 165 | 13)Column from 15.90 m to 16.90 m |
| 166 | Circular Column |
| 167 | 1)Column 0 to 3 m ht below GL |
| 168 | 3)Column from 3.6 m to4.90 m |
| 169 | 4)Column from 4.90 m to 5.90 m |
| 170 | 5)Column from 5.90 m to 6.90 m |
| 171 | 6)Column from 6.90 m to 7.90 m |
| 172 | 7)Column from 7.90 m to 8.90 m |
| 173 | 8)Column from 8.90 m to 9.90 m |
| 174 | 9)Column from 9.90 m to 10.90 m |
| 175 | 10)Column from 10.90 m to 11.90 m |
| 176 | 11)Column from 11.90 m to 12.90 m |
| 177 | 12)Column from 12.90 m to 13.90 m |
| 178 | 13)Column from 13.90 m to 14.90 m |
| 179 | 13)Column from 14.90 m to 15.90 m |
| 180 | 13)Column from 15.90 m to 16.90 m |
| 181 | B)Plain surface |
| 182 | 1)0.00m to 3.60m below and Above GL |
| 183 | 2)From 3.60 m to 4.90 m |
| 184 | 4)From 6.90 m to 7.90 m |
| 185 | 5)From 7.90 m to 8.90 m ht. Above G.L. |
| 186 | 6)From 10.90 m to 11.90 m |
| 187 | 6)From 11.90 m to 12.90 m ht. Above G.L. |
| 188 | 7)From 12.90 m to 13.90 m ht. Above G.L. |
| 189 | From 13.90 m to 14.90 m |
| 190 | From 14.90 m to 15.90 m |
| 191 | 8)From 15.90 m to 16.90 m ht. Above G.L. |
| 192 | 9)From 16.90 m to 17.90 m ht. Above G.L. |
| 193 | C)Curved surface |
| 194 | From 0.00 to 3.60m HEIGHT |
| 195 | From 3.60 to 4.90m HEIGHT |
| 196 | From 13.90 m to 14.90 m |
| 197 | From 14.90 m to 15.90 m |
| 198 | 5)From 15.90 m to 16.90 m ht. Above G.L. |
| 199 | 5)From 16.90 m to 17.90 m ht. Above G.L. |
| 200 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500,Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 201 | Supply, delivery and fixing of Cut stone of approved quality set in Cement Mortar 1:3 mix including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification |
| 202 | Supply, delivery and fixing of RCC Inner Ladder of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification |
| 203 | Providing RCC spiral staircase as per approved design.(10LL-16m St) |
| 204 | Providing RCC spiral staircase as per approved design(8.00LL-18m St) |
| 205 | Providing RCC spiral staircase as per approved design (1LL-12m St) |
| 206 | Supply, delivery and fixing of RCC Handrails of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification |
| 207 | Supply, delivery and fixing in position FRC manhole 600mm dia FRC manhole cover to suit 600 mm clear opening manhole frame & manhole cover to suit 600 mm clear opening manhole frame complete and as directed by the Officers.(TWAD SOR 25-26 PG.NO-35)(WD-M0593)(WD-M1357 & WD-M1357)(1058.22+1511.02) |
| 208 | Supply, delivery and fixing of PVC Ventilator of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification.(AC COWL 100mm Dia) (TWAD SOR 25-26 PG.NO-163)(WD-M-00593) |
| 209 | Labour charges for erection of DI Pipe with spicals including cost and convince of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification. |
| 210 | Inlet & outlet Overflow Pipe connections |
| 211 | 10.00LL OHT-16m |
| 212 | 8.00LL OHT-18m |
| 213 | 3.00LL -OHT-18m |
| 214 | 1.00LL -OHT-12m |
| 215 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 216 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. |
| 217 | Supply, delivery and fixing of enameled water level indicator of approved design and pattern (graduation in metric system) with required all accessories as directed by TWAD Board Officers. ( The rates including loading, unloading, transportation charges etc.,)(TWAD SOR -25-26,WD-M1384) |
| 218 | Supply, Delivery, erection and commissioning of Batch type electro chlorinator using common salt as raw material, consisting of electrolyzers cell made of Titnium with coating mixed met al oxide such as Anabium, Cadmium, etc, capable of producing sodium hypochlorite solution within time span of 8 hours, having adjustable metering cum dosing pump capable of dozing the prepared sodium hypochlorite solution in water supply system with sensor having auto shut down when the storage if FRP tank gets empty. The storage vessel and electrolyzer tank (hypo procesing tank) must be made of FRP tank coated inside with hypothalic -BIS standard, having capacity to store required quantity of hypochlotrite solution, water and common salt for electrolysis process respectively. The eclectrochlorinator must have power source or control module for producing necessary DC current for electrlyser process from 440v, 3 phase / single phase AC supply and must have auto cut off after batch time of 8 hours. For all power connection, copper cables should be used |
| 219 | 1.00LL -OHT-16m (WD-M1507) |
| 220 | 3.00LL OHT-18m-(WD-M1511) |
| 221 | 8.0LL OHT-18m-(WD-M1521) |
| 222 | 10.00LL OHT-16m-(WD-M1525) |
| 223 | Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers. |
| 224 | Brick work in Cement Mortar 1:5 using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 225 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 226 | Supply and Delivery Fabrication of MS doors and windows with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles,plates, sheets, fabrication charges,cost of hold fast and transportation charges etc., complete..(TWAD SOR 25-26 PG.NO-108) |
| 227 | Fully panelled Signle leaf - Door-(1.00mx2.00m)-(WD-M1486) |
| 228 | Fully panelled Double leaf - Window (without Ventilator)-1.20mx0.90m-(WD-M1487) |
| 229 | Ventilator (045mx0.60m)-(WD-M1489) |
| 230 | Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) a. Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm |
| 231 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 232 | Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers Using Pressed Tiles of size 200mm x 200mm x 16mm to 18mm |
| 233 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). SD 26 |
| 234 | Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting SD 88 |
| 235 | Supply and fixing of horizontal type 4way triple pole neutral MCB distribution board in sheet steel enclosure double door(metal)with 40A 4pole MCB isolater as incoming and 12Nos.6A to 32A SPMCB as outgoing in flush with wall and making good of the concealed portion with earth connection.The MCBDB and MCB's should be with the ISImark (like standard make) SD 157 |
| 236 | Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5m SD.75 |
| 237 | Supply and run of 4x6sq.mm.PVCinsulatedS Cunsheathed FRLS coppe conductor of 1100V on7 /20 GI bearerwire for service connection mains SD 68 |
| 238 | House service connectionHSC Connection - 20 mm - Providing House service connection with MDPE 20mm pipe (supply, lowering, jointing & testing), electrofusion tapping saddle PE 80 blue, PN 12.5 with female threaded metal insert of SS 304, Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded to suit the corresponding bore sizes of 15mm dia size (1/2\\",), Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304, Poly propylene 90 Degree Compression elbow with compression joint at both ends, Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 and protection box of size 20cm x 30cm for fixing of Water Meter all as per standard including road cutting, replacement of utilities providing house service connection, refilling, retoration of roads/drains testing etc complete with materials and specification as instructed by department officers.(TWAD SOR 25-26 PG.NO-30) |
| 239 | 20mm MDPE HSC in 80mm GI PIPE |
| 240 | 20mm GI HSC in 100mm GI PIPE |
| 241 | 20mm MDPE PIPE in HDPE pipe |
| 242 | Road restoration for HSC connection including CC 1:5:10 & CC1:2:4 |
| 243 | Supply and delivery of GI 50mm (m)class pipe for encasing 20mm pipe in strom water drainage crossing (WD-M0489) |
| 244 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 245 | Provision for GST 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 28 daysDec 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender