BOQ
| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.as per DSR 2.31 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. As per Code No. 2.8.1 |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.as per DSR 2.27 |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 fine sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per DSR Code No. 4.1.8 |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). As Code No-5.1.2 |
| 6 | Centering and shuttering including stutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete. As per DSR Code No- 5.9.1 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Above Plinth Level. As per Code No-5.2.2 |
| 8 | Centering and shuttering including stutting, propping etc. and removal of form for Columns, pillars, piers, abutments, posts and struts. As per DSR Code No- 5.9.6 |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand). As per DSR Code No- 6.1.2 |
| 10 | Centering and shuttering including stutting, propping etc. and removal of form for Lentels beams, plinth beams, girders, bressumers and cantilevers, As per DSR Code No- 5.9.5 |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Level. As per Code No-5.3 |
| 12 | Centering and shuttering including stutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access plateform. As per DSR Code No- 5.9.3 |
| 13 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per Code No.- 5.22 .6 |
| 14 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. M.S. Angle 35x35x5 for door frames As per Code No. 10.31 |
| 15 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, i/c applying a priming coat of approved steel primer. Using flats 36x6 mm for diagonal braces and central cross piece As per Code 10.5.2 |
| 16 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution DSR Code No.13.53.1 |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of Class designation 7.5 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ). As per Code No 6.4.2 |
| 18 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of Class designation 7.5 in super structure above plinth level upto floor V level. cement mortar 1:4 (1 cement : 4 coarse sand ). As per Code No 6.13.2 |
| 19 | 12mm cement plaster in single coat on fair side of single or half brick wall for interior plastering upto floor two level including brick wall for interior plastering upto floor two level including internal rounded angles chafers,and or rounded angles not excedding 80mm in grith and finished even and smooth No.extra for mixing and additive.1-1Cement:6 Sand as per DSR 13.1.2 |
| 20 | 12mm cement plaster in single coat on rough side of single or half brick wall for interior plastering upto floor two level including internal rounded angles not excedding 80mm in grith and finished even and smooth. As per Code No 13.2.2 |
| 21 | E/w in filling or in embankment in foundation or plinth in ordinary soil including lift up to 1.5m and lead up to 30m and including filling watering ramming of excavated earth as per dsr 2.25a |
| 22 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface. As per Code No-13.80 |
| 23 | Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers specifications two or more coats applied on wall @ 1.25ltr/10sqm over and i/c one coat of special primer applied @ .90litre/10sqm as per DSR 13.48.1 |
| 24 | Providing & laying rectified glazed ceramic floor tiles of size 300x300 mm or more ( thickness to be specified by the manufacturer), of 1st quality confirming to IS:15622, of approved make, in colours white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grounting the joints with white cement and matching pigmrnts etc., complete. As per Code No-11.39 |
| 25 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. As per DSR Code No.8.31 |
| 26 | Providing and laying vitrified floor tiles in different sizes (thickness to be .specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.as per DSR 11.41.2 600mmx600mm size |
| 27 | Providing & laying polished Granite stone flooring in required design and patterns in linear as well as curvillinear portions of the building all complete as per the architectural drawing with 18mm thick in salb/rises of steps,skirting,dado & pillers laid on 20mm thick base of cement 1:4 laid and jointed with cement slurry mixed with pigment to match the shade of slabs including rubbing and polishing completed.as per DSR 8.2.2.2 |
| 28 | Making drip course in sun shade or FACIA as per direction of engineer in charge including supply of all materials labour etc.for proper completion of the work.as per DSR 5.30 |
| 29 | Providing stainless steel made sliding bolts 16mm dia with nuts and screw 250 mm long as per DSR 9.96.1 |
| 30 | Providing stainless steel made tower bolts dia with nuts and screw 150 mm long as per DSR 9.97.1 |
| 31 | Supply & fixing of information board |
| 32 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.As per DSR Code No. 10.18 |
| 33 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nóminal size stone aggregate.As per DSR Code No.11.3.1 |
| 34 | GST PAID EXTRA AS PER GOVT Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender