Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #58508322

Tender For Replacement Of Asbestos Sheets With Galvelum Sheets In Mt Sheds Under Ge (Af) Borjhar

Issued by Statutory Bodies & Commissions/Committees · Kamrup Metro, Assam
Tender Value
41.84 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
8 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Replacement Of Asbestos Sheets With Galvelum Sheets In Mt Sheds Under Ge (Af) Borjhar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 23-Nov-2026 Corrigendum No 01 Other 03-Dec-2026

BOQ

Name of Work:- REPLACEMENT OF ASBESTOS SHEETS WITH GALVELUM SHEETS IN MT SHEDS UNDER GE (AF) BORJHAR
Sl. No. Item Description
1Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc complete all as specified
2S&F for Galvalume zinc coated GI based corrugated sheet shall be 0.50mm thick (total coated thickness), 550 Mpa minimum, yieldstrength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon andfinished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. all as specified and directed.
3S&F for Galvalume zinc coated GI based plain sheet shall be 0.50mm thick (total coated thickness), 550 Mpa minimum, yieldstrength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. all as specified and directed.
4Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
5S&F rolled mild steel Fe-410-W (Gde-E-250) quality-B as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed by Engineer-in-Charge.
6M&L for preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth over a coat of red oxide primer, complete all as specified and directed .
7M&L for applying one coat of synthetic enamel paint to old painted steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer -in-Charge.
8M&L for applying one or more coat of white wash to old decorated (white washed) surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed by Engineer -in-Charge.
9M&L for Taking down cement plaster in any description on brick or stone wall etc incl racking out joints.hacking for key scrubbing down with water etc. all as specified and as directed by Engr-in-Charge.
10M&L for 15mm thick rendering in cement mortar (1:6) to fair faces of brick or concrete wall surfaces finished even & smooth without using extra cement all as specified and directed by Engineer -in-Charge.
11Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets, complete all as specified & directed.
12M&L for Non asbestos fibrecement building boards 4-6mm in thickness fixed orlaid/ inserted to timber/GI/Aluminium frame work with screws along with Anodised aluminium snap gridframe work for false ceiling Size of grid 605 x 605mm all as specified and directed.
13M&L for three coats of white wash on newly plastered surfaces of wall including preparation of surface complete.
14M&L for preparation of newly plastered wall surfaces and applying two coats of Oil Bound Distemper over a coat of alkali resistant primer applied complete all as specified and directed by Engineer -in-Charge.
15Demolition of brick work or stone / boulder masonary built in CM including all quoins, arches, pillars, etc but excluding ashlar, facing, dressed stone work and pre-cast concrete articles complete all as specified and as directed by Engineer-in-Charge
16M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed.
17Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed by Engr-in-charge
18Material and labour for point wiring for the One light/fan point controlled by one,one way switch with 1.5 Sqmm single core, PVC FRLS insulated unsheathed, multistranded copper conductor drawn through and including PVC casing and caping including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick complete all as specified and directed.
19All as per serial item No 18 here in before but for one 3 pin 5 Amp socket outlet on independent board.
20All as per serial item No 18 here in before but for one 3 pin 5 Amp socket outlet on same board.
21S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals (ISI Marked), AC, 230 Volts complete all as specified & directed.
22S&F switch piano flush type single pole one way (ISI Marked), 6 Amp, AC,230 V all as specified and directed.
23S&F socket outlet flush type 2 in 1, 6A, AC, 230V complete all as specified and directed.
24S&F switch & socket combination flush type 2 in 1, 6A, AC, 230V complete all as specified and directed.
25S&F switch socket combination flush type 2 in 1, 6 Pin, 20/10 Amp, AC, 230V with four fixing holes complete all as specified and directed.
26Material and labour for Point wiring with 4.0 sqmm FR PVC insulated and sheathed multi stranded (FRLSH) copper conductor cable drawn in PVC casing and Caping on surface wall, ceiling with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness plastic laminated sheet, cover for one 3 pin socket outlet 15 Amp on independent board including continuous 4.0 sqmm copper conductor cable (FRLSH) (multistranded) PVC insulated and unsheathed Cable as earth wire to common earth dolly, complete all as specified and directed by Engr-in-charge
27Supply and fix DB 8 way MCB SPN double door, glazed type, IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09, complete all as specified and directed. Make- Legrand / Indo asian / Havells or its equivalent in specified makes in CA.
28Supply & fix MCBs single pole (SPN) 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards confirming to IS/IEC 60898-1 (ISI merked) complete all as specified and directed.
29Supply & fix MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards confirming to IS/IEC 60898-1 (ISI merked) complete all as specified and directed.
30S&F in Replacement of existing sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 4.0 Sqmm drawing into and including PVC casing and caping of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 4.0 Sqmm as a earth continuity conductor(green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 4.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 4.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
31M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. (Note: The rate quoted shall inclusive of GI wire 4 mm dia with GI pipe protection 15 mm, light grade up to 7.5 m)
32Material & labour for Sub main wiring with two runs of single core 1.5 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh into PVC non metallic rigid conduit concealeed including PVC insulated stranded copper conductor nominal cross section area as under as contineous earth continuity wire complete all as specified. Two run of 1.5 Sqmm cable one run of 1.5 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed.
33Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
34S&F for Energy saving, environmental friendly, long life, exclusive innovative die-casting aluminium IP66 Highbay light of 55/50 watt capacity with suitable hook/clamp mounting on ceiling/wall, suitable for highlighting architectural facade and general purpose lighting complete Make : Havells Cat No-EMBERROULTRAHBP055WLED757PWBTORLBLK equivalent make specified Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58508322
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 41.84 Lakhs
LAST DATE 03-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Replacement Of Asbestos Sheets With Galvelum Sheets In Mt Sheds Under Ge (Af) Borjhar
Basic Detail
Tender No 9174
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 23 Nov 2026
Submission Date 03 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value 41.84 Lakhs
Tender Fee 500
EMD 84000
Exemption Available
Document List
9174tender.pdf
a12ac9dc-94ef-45f8-9bb1-d0c3f3430aa6.html
BOQ_895693.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

9174tender.pdf

html

a12ac9dc-94ef-45f8-9bb1-d0c3f3430aa6.html

xls

BOQ_895693.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender