Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #58508293

Tender For Special Repair To Bldg No A-22 (Or Accn) Of 417 Fd Hosp At Rhenock Under Ge 867 Ews.

Issued by Statutory Bodies & Commissions/Committees · pakyoung, Sikkim
Tender Value
22.82 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
12 days left
EMD
45640
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
pakyoung → Sikkim
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Bldg No A-22 (Or Accn) Of 417 Fd Hosp At Rhenock Under Ge 867 Ews.

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG NO A-22 (OR ACCN) OF 417 FD HOSP AT RHENOCK UNDER GE 867 EWS.
Sl. No. Item Description
1Dismantling of plain or corrugated steel sheeting of any gauge, thickness including Nainital pattern roof covering, etc. complete all as specified and as directed.
2S&F Pre- painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with seif tapping screws, etc. complete all as specified and as directed.
3S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with seif tapping screws, etc. complete all as specified and as directed.
4Dismantling wrought iron or mild steel work of any description, etc. complete all as specified and as directed.
5S&F Roof trusses (Framed), trussed , purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections ) including distance pieces cleats etc FE-410W (Gde E-250) quality A, etc. complete all as specified and as directed.
6Dismantling of wall and ceiling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness including cover, etc. complete all as specified and as directed.
7S&F GI frame work of size 605 x 605mm, for seamless celing comprising of GI perimeter chanel 0.55mm thick with two unequal flangesof 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and incl ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, etc. complete all as specified and as directed.
8S&F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasterners 12.5mm dia 40mm long, etc. complete all as specified and as directed.
9M&L for 4mm thick asbestos cement plain building boards, fixed or laid /inserted to GI snap grid framework with screw in ceilings, etc. complete all as specified and as directed.
10M&L for preparation of AC Boards and applying three coats of white wash on ceiling, etc. complete all as specified and as directed.
11Demolition of brickwork or stone/boulder masonry built in cement mortor, etc. complete all as specified and as directed.
12M&L for Precast cement concrete block masonry with solid blocks of type C-1 (1:3:6) (using 20mm graded stone aggregate) of 10cm in width and setting in CM 1:6, etc. complete all as specified and as directed.
13M&L for RCC type B-1 (1:2:4) (using 20mm graded stone aggregate) as in beams cantilevers, bressumers, lintels over 1.5m span, etc. complete all as specified and as directed.
14Formwork to sides and soffits of floor or roof beam, beam hunching, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams of fair finish surface, etc. complete all as specified and as directed.
15M&L for 10mm dia and over Mild steel TMT Bars cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (annealed not less that 0.90 mm dia or securing with chip), etc. complete all as specified and as directed.
16Description all as per item No 15.00 here-in-before but for 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders, etc. complete all as specified and as directed.
17Taking down cement plaster on brick or stone masonry surfaces of walls etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
18M&L for 15mm thick rendering in CM 1:6 on fair faces of brick or block concrete masonry walls and finished the surface even and smooth without using extra cement, etc. complete all as specified and as directed.
19M&L for 20mm thick rendering in two layers of 10mm each in CM 1:4 on other than fair faces of brick or block concrete masonry walls with WPC including finished even and smooth without using extra cement, etc. complete all as specified and as directed.
20M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whiting as priming coat, including a thick layer of wall care putty (Birla white or equivalent), etc. complete all as specified and as directed.
21M&L for Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of chalk whiting primer, etc. complete all as specified and as directed.
22Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area n.exc 1.5 sqm, etc. complete all as specified and as directed.
23Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm, etc. complete all as specified and as directed.
24S&F Pressed steel door frame for doors, size 165 x 60mm with one rebates incl necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
25S&F 35mm thick plain framed panelled shutter (any number of panels) of 2nd class H.W with panels of timber flat on both sides or of venerred particle boards medium density, wood particle board with commercial face veeners, etc. complete all as specified and as directed.
26S&F 1st class hard wood 30mm thick Glazed and skeleton shutter, poen rebated and prepared to receive glass, gause,etc (without sash bar), edges of framing plain or chamfered or rounded, fitted with cut and mitred beads for securing glass etc; size of members of shutters as specified in SSR -I ,section 8, clause 8.24 (a) supplied and fitted to chowkhats, etc. complete all as specified and as directed.
27S&F Steel windows with side hung shutters incl projecting type hinges with steel handle, and steel peg stay complete with glazing bars, etc. complete all as specified and as directed.
28S&F Steel windows with side hung shutters incl projecting type hinges with steel handle, and steel peg stay complete without glazing bars, etc. complete all as specified and as directed.
29S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; and similar work conforming to Fe.290.Gde-E-165, etc. complete all as specified and as directed.
30S&F 3mm thick sheet glass, oridinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane, etc. complete all as specified and as directed.
31S&F Galvanised wire cloth, 0.63 mm nominal dia of wire and average width of aperature 1.4mm and fixed with tinted tacks or galvanised wire staples as in fly proof window and door, etc. complete all as specified and as directed.
32S&F 250 mm long Aliminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium, etc. complete all as specified and as directed.
33S&F 150mm long Aluminium anodised extruded alloy handles of fabricated type and fixed with screws, etc. complete all as specified and as directed.
34S&F 200 mm long Aluminium anodised barrel tower bolts of extruded section fixed with screws, etc. complete all as specified and as directed.
35M&L for Preparation of new wooden surfaces of any description, over 10cm width or girth not other wise described and applying two coat of synthetic enamel paint over one coat of pink primer on , etc. complete all as specified and as directed.
36M&L Preparation new steel surfaces of any description over 10cm width or girth not other wise described and applying two coat of synthetic enamel paint over one coat of red oxide primer, etc. complete all as specified and as directed.
37Dismantling floor, hearth or wall tiling incl cement mortar bedding, backing, removing serviceable tiles to store and rubbish off the premise, etc. complete all as specified and as directed.
38M&L for 7 to 8mm thick Joint free non skid ceramic colured tiles area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors and pointd in coloured cement to match, set and jointed in neat cement slurry over and including 15mm thick screed bed or bedding layer in CM 1:6, etc. complete all as specified and as directed.
39M&L for 300 x 200mm x 7mm thick Glazed ceramic coloured tiles on vertical surfaces such as skirting, dados and pointed in colour cement to match, set & Jointed in neat cement slurry over and including 15mm rendering in CM 1:4 , etc. complete all as specified and as directed.
40S&F 25mm dia decorative type curtain rod (curtain rails) of stainless steel (SS-304 grade) including suitable selective choice decorative knobs and brackets fixed with wall flange and screws including takingdown existing curtain rods, etc. complete all as specified and as directed by Engr-in-Charge.
41Demolition of cement concrete (Unreinforced) in ground floor and pavings n exc 15cm thick ness (below or above ground level), etc. complete all as specified and as directed.
42M&L for 75mm thick PCC type C-2 (1:3:6) (using 40mm graded stone aggregate) as in path, plinth protection, etc., complete all as specified and as directed.
43Form work to sides of concrete foundations, footings, bases of columns and plinth beam and similer work etc in rough finished surfaces of concrete flat, etc. complete all as specified and as directed.
44M&L for PCC type C-2 (1:3:6) (using 40 mm graded crushed stone aggregate) as in surface channels and drains, etc. complete all as specified and as directed.
45Taking down old existing copper/aluminium point wiring (light fan, Socket or power) Complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors, etc. complete all as specified and as directed.
46M&L for concealed point wiring with 1.5 Sqmm (nominal area) PVC insulated unsheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm size, medium grade with all necessary fittings, concealed wiring, for light / Exhaust fan point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed for mounting of fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover, for housing switches, socket outlet, regulator etc. complete all as specified or directed including testing on completion, etc. complete all as specified and as directed. Make : Plaza/Havells/KEI
47Description all as per item No 46.00 here-in-before but for one 3 / 5 -pin switch socket outlet 5 amps on independent board, etc. complete all as specified and as directed.Make : Plaza/Havells/KEI
48Description all as per item No 46.00 here-in-before but for One 3 pin socket outlet 5 Amps on the same board with other switchs with cables 1.5 Sqmm size, etc. complete all as specified and as directed. Make : Plaza/Havells/KEI
49Description all as per item No 46.00 here-in-before but for one switch socket outlet 15 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable, etc. complete all as specified and as directed.. Make : Plaza/Havells/KEI
50S&F 5A Switch piano flush type single pole one way , etc. complete all as specified and as directed.
51S&F 5A Switch socket combination 3 pin flush type (multi purpose ), etc. complete all as specified and as directed.
52S&F 5/15A Switch socket combination 2 in 1, 3 pin, flush type universal, etc. complete all as specified and as directed.
53S&F Lamp holder, PVC/Polycarbonate type and back plate suitable for batten fitting, etc. complete all as specified and as directed.
54S&F 65 X 50 mm Ceiling rose surface bakelite three terminal , etc. complete all as specified and as directed.Make : Anchor/Havells/Plaza
55S&F in repairs 1x9W LED Light fitting Bulkhead luminaires including LED light driver connecting up with three core flexible copper conductor cable of suitable size, etc. complete all as specified and as directed.
56S&F in repairs 1x 18W LED lights fitting, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose , etc. complete all as specified and as directed.Make: Havells/Philips/Wipro/Crompton
57S&F in repairs 9W LED Bulb suitable for B22 holder, system efficacy should be > 85 lm/ W. PF > 0.9, The Lamp Should have Cool Daylight Color temp of 6500K, lumen output >800 lm, etc. complete all as specified and as directed.Make: Philips/Wipro/Crompton
58S&F in repairs 35W LED Street light fitting 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection clamps, etc. complete all as specified and as directed.Make : Philips/Havells/Crompton.
59Disconnection and taking down distribution boards, switch fuse unit, enclosure for MCB/MCB Box including MCB's of any type and size and keeping aside for reuse of serviceable one, etc. complete all as specified and as directed.
60S&F Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral link of 8 way 415 Volts, etc. complete all as specified and as directed.Make- Legrand or equivalent in Siemens/Schneider.
61S&F 40 Amp to 63 Amps MCB Single pole and neutral of 10 KA, 240 Volts 50 HZ, 'C' curve, etc. complete all as specified and as directed.Make/Cat part No: 4086 18 of Legrand or equivalent in Siemens/Schneider.
62S&F 5-32A MCB single pole (SP), 10 KA of 240 Volts, 'C' curve, etc. complete all as specified and as directed.Make: Cat part No: 4085 95 of Legrand or equivalent in Siemens/Schneider
63Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor including taking down existing wiring, etc. complete all as specified and as directed. Make : KEI/Plaza/HavellsNote: Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
64M&L for Earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC type C-1 (1:3:6), 50 mm thick Pre-cast RCC type B-1 (1:2:4) as cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking down exisinting earthing, etc. complete all as specified and as directed.
65Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n.exc. 1.50m deep for HT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, etc. complete all as specified and as directed.
66Returning filling including spreading leveling watering and well ramming in layers not exc 25cm in soft/ loose soil, etc. complete all as specified and as directed.
67Removing excavated material in soft/ loose soil n.exc 50m and depositing where directed at a level n'exc1.5m above the starting point, etc. complete all as specified and as directed.
68M&L for sand cushioning to U/G cable in layers of 23cm thick (8 cm before laying the cable and 15cm thick after laying the cable) in trenches, etc. complete all as specified and as directed.Note :- Only Puned layers shall be measured.
69Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 in flat of size 250mm x 150mm x 40mm thick, etc. complete all as specified and as directed.
70Supply and Laying in replacement of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trenches or on wall with the help of shadel of size 25 Sqmm 4 core as required at site, etc. complete all as specified and as directed.Make : Havells/KEI/Plaza
71M&L for 25 mm bore GI tube of light grade for passing through cables under the floor along the wall or pole and fixed with suitable size of MS clamps and nut and botls/washers including taking down existing pipes, etc. complete all as specified and as directed.Make : Jindal/TATA or equivalent Please Enable Macros to View BoQ information
72M&L for 25 mm bore GI tube of light grade for passing through cables under the floor along the wall or pole and fixed with suitable size of MS clamps and nut and botls/washers including taking down existing pipes, etc. complete all as specified and as directed.Make : Jindal/TATA or equivalent Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58508293
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22.82 Lakhs
LAST DATE 03-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg No A-22 (Or Accn) Of 417 Fd Hosp At Rhenock Under Ge 867 Ews.
Basic Detail
Tender No 8622/E8
Bidding Type Tender
Location
City pakyoung
State Sikkim
Key Dates
Publish Date 12 Nov 2026
Submission Date 03 Dec 2026
Open Date 05 Dec 2026
Finance
Tender Value 22.82 Lakhs
Tender Fee 500
EMD 45640
Exemption Available
Document List
BOQ_895685.xls
d0aa7d77-0630-480a-aecf-a545446bd009.html
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Dec 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_895685.xls

html

d0aa7d77-0630-480a-aecf-a545446bd009.html

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender