Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #58507952

Tender For Special Repair To Mag No 04 Of Asd At Cod Under Ge (East) Jabalpur

Issued by Statutory Bodies & Commissions/Committees · Jabalpur, Madhya Pradesh
Tender Value
48.44 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
11 days left
EMD
96900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Mag No 04 Of Asd At Cod Under Ge (East) Jabalpur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Nov-2026 Make corrigendum Other 03-Dec-2026

BOQ

Name of Work:- SPL REPAIR TO MAG NO 04 OF ASD AT COD UNDER GE (EAST) JABALPUR
Sl. No. Item Description
1M&L for Water Proofing Treatment on \\"Non Approachable/Non Accessible and Approachable Roof\\" surfaces (Horizontal & Vertical surfaces) in following sequence through manufacturer/authorized applicator of the manufacturer complete all as specified and directed (Appicabale for 1.1 to 1.5)
2M&L for rendering 10 mm thick in cement mortar 1:4 on roof or concrete surfaces complete all as specified and directed.
3M&L for applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg per Sqm complete all as specifed and directed
4M&L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg per Sqm including cleaning surfaces complete all as specifed and directed
5M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on bitumen coated surface with 100 mm overlaps shall be sealed by flame as per manufacturer's instruction including removal of existing one complete all as specified and directed.
6M&L for cement concrete tiles 30cm x 30cm x 22mm thick, machine pressed; set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over & including 15 mm thick screed bed or bedding layer of 1:6 cement mortar for laying floor finishes complete all as specified and directed.
7Supply only liquid water proofing compound ISI marked complete all as specified & directed.
8Excavation over areas n.exc. 1.5m deep and getting out in soft /loose soil complete all as specified and directed
9Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
10Returning, filling in any type of soil , including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
11M&L for Good Earth filling above MAG, spreaded, levelled each layer n. exc 25 cm as approved by GE complete all as specified and directed.
12Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed
13M&L for 20mm thick wearproof topping as specified (by incorporating an approved metallic floor hardner), finishing even and smooth without using extra cement (except metallic hardner) over & including 30mm thick granolithic concrete 1:1:2 floor topping laid over cement concrete sub floor etc and finished to an even and fair surface complete all as specified and directed.
14Supply only metallic hardner of approved make.
15M&L for forming 20 mm thick expansion joint for 200 mm thick concrete slab filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound grade 'A' complete all as specified and directed.
16M&L for forming contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade 'B' complete all as specified and directed.
17M&L for cement concrete work in pavement/hard standing of flexural strength 40 kg/sqcm in field using 400 kg of cement per cum of concrete of thickness 25 cm or less complete all as specified and directed.
18Supply and laying 400 micron thick HDPE sheet (virgin quality) water proof , wrinkle free without punchure having minimum weight 390 gm/Sqm over sand cushion with overlap between adjacent strips and at tranverse joint as minimum 300 mm complete all as specified and directed
19M&L for PCC 1:2:4 type B0 (Using 12.50 mm graded stone aggregate) in roof padding/kerbs/sunken slab etc complete all as specified and directed
20Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed
21Dismantling framed timber scantlings 40 sq. cm & over in section, in any position complete all as specified and directed
22Dismantling of Asbestos cement sheet ( corrugated, semi corrugated etc) in roof covering roof covering complete all as specified and directed.
23S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
24S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
25M& L for 1.25 mm thick, 150 mm dia Mild steel sheet eaves gutters, galvanised class 3, half round with rounded edges complete all as specified and directed
26S&F for Drop ends (for spigot or socket ends) or nozzles of dia 150 mm complete all as specified and directed
27S&F for Stop ends (for spigot or socket ends) of dia 150 mm complete all as specified and directed
28S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
29S&F MS steel flat iron as in wind tie for roof sheet including securing bolts complete all as specified and directed.
30M&L 6mm thick asbestos cement, corrugated or semi-corrugated shets in roofs, walls, etc. Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
31M&L for 6mm thick asbestos cement one piece plain angular ridge Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
32Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified and directed.
33M&L for Brick work with old size subclass ‘B’ bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
34Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil complete all as specified and directed.
35Excavation in trenches, n exc 1.5m wide & exc 1.5m but n exc 3.0m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil complete all as specified and directed.
36Excavation in trenches, n exc 1.5m wide & exc 3.0m but n exc 4.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & n exc 1.5m in depth & getting out in soft/loose soil complete all as specified and directed.
37M&L for cement concrete 1:4:8, type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specifed and directed.
38M&L RCC M-25 (design mix) using 20 mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specifed and directed.
39M&L RCC M-25 design mix using 20 mm graded aggregate in as walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specifed and directed
40Use and waster Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Rough finished surfaces of concrete flat complete all as specifed and directed
41Use and waste Formwork to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better Rough finished surfaces of concrete flat complete all as specifed and directed
42M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specifed and directed
43M&L Mild steel TMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specifed and directed
44S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specifed and directed
45Taking down Chowkats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specifed and directed
46S&F 2nd class hard wood Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specifed and directed
47S&F 40 mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specifed and directed
48S&F Brass handles 150mm size, cast type, polished bright complete all as specifed and directed
49S&F Butt hinges 125mm size, medium weight, cold rolled mild steel complete all as specifed and directed
50S&F Brass, sliding door bolt 300mm long with sand or die-cast brass hasp, staple (bolt type) & fixing bolt with rolled or drawn brass bolts complete all as specifed and directed
51M&L for copper sheet fixed to flush door on both faces (inner and outer) with all fitting arrangement complete all as specified and directed.
52M&L 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection complete all as specified and directed.
53M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.50m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates etc and the like including weathering slightly rounded/ chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
54M&L for 100mm thick PCC 1:4:8 type C-1 using 20 mm graded crushed stone aggregate as in Sub base laid in panels & finished even and smooth without using extra cement complete all as specified and directed.
55M&L for Moorum/red bajri filling, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering as required complete all as specified and directed.Note: Consolidated thickness shall be measured.
56M&L for Hard Core of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed..
57M&L for 80mm thick coloured machine pressed precast concrete interlocking paver block glossy finished any size and shape conforming to IS 15658-2006 , M-40 Grade with grey cement and pigment over stone dust filling complete all as specified and directed.(Cost of sand will be measured and paid separately)
58M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
59Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
60M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of external wall in CM 1:4 and to be finished even and smooth without using extra cement complete all as specified and directed.
61M&L for rendering 5 mm thick in cement mortar 1:3 on RCC ceiling surface and finished even and smooth (without using extra cement) complete all as specified and directed .
62M&L 10 mm thick rendering on fair faces of brick work or concrete surfaces of internal wall in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
63M&L for applying two coats of synthetic enamel paint over one coat of red oxide, zinc chrome primer on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth, including preparation of new surface complete all as specified and directed.
64M&L for applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer on steel & iron surfaces of any description, n. exc 10cm width or girth when unconnected with other painting or when painted in different tint, including preparation of new surface complete all as specified and directed.
65Preparation of new surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth and applying two coat of fire resistance paint complete all as specifie and directed.
66Preparation of old surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth and applying one coat of fire resistance pain complete all as specified and directed.
67Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
68S&F of Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed.
69Demolition of cement concrete (reinforced) of any description & in any position not otherwise specifically provided for complete all specified and directed.
70M&L Precast cement concrete type B1 (1:2:4) using 20 mm graded aggregate set in CM(1:4) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specifed and directed
71Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 100m or under, beyond the ead included in the rates, including loading, unloading and stacking at the destination complete all as specifed and directed
72Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including such as switches, ceiling roses, holders, pendants, regulators, sockets etc and making good disturbe cement mortar, white cement, putty etc and match with existing surfaces of walls, floors etc complete all as specified as directed
73Taking down carefully any type of old unserviceable submain wiring with PVC/steel conduit surface / concealed or wooden battens etc and making good the disturbed surfaces to match with the existing surface complete all as specified & directed by Engineer-in-Charge.
74Taking down carefully any type of DBs including MCCBs and MCBs for keeping the old materials into safe taking credit(credit for above items should be made as per condition separately) and making godd toB surface etc complete all as specified and directed.
75Material and labour for point wiring for explosive atmosphere with 1100 volts grade, PVC insulated single cable with stranded copper conductor of size 2.5 sqmm drawn through and including ERW rigid stove enar conduit of size 18/19mm dia with bends, elbows, couplings and ceiling rose etc., duly approved by CMRI Dhanbad and as per IS, fixed with PVC FRLS, insulated unsheathed multi stranded copper conductor cable of 2.5 sqmm as an earth wire connected to common earth and earth dolly as per IS specification for one light/fan point controlled by one switch complete all as directed.
76All as per item No 70 here-in-before but one socket point 5 Amp controlled by one switch on same board.
77All as per item No 70 here-in-before but one socket point 5 Amp controlled by one switch on Independent board.
78All as per item No 70 here-in-before but with 1100 Volts grade copper stranded conductor FRLS cable of size 4 Sqmm main & with 4 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board
79Supply and fixing in replacement of flame proof rotory switch, LM-6 aluminium body enclosure with threaded cover and switch operated by a shrouded knob, single pole, 16 amps, 250 V capacity with double entries way suitable for 20 mm dia ERW threaded rigid steel conduit duly approved by CMRI Dhanbad complete all as directed.
80S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specifie and directed.
81S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specifie and directed.
82Supply and fixing in replacement of FLP DB TPN 4 way of die casting aluminium housing with IP 66 degree protection with proper fixing arrangements with Incoming cable size upto 3.5 core 50 sqmm. With MCB 63 Amps as a incoming TPN, outgoing with 12 Nos of MCB SP rating 6-32 A complete all as specified and directed.
83Supply and fixing in repair FLP-WP MCB FP up to 32 Amps, 415 V, 50 HZ Complete all as specified and directed Make: Sudhir Cat No: DOLS/187 or Shyam/Baliga/Pluto
84Supply and fixing in repair FLP-WP MCB SP up to 25 Amps, 240 V, 50 HZ Complete all as specified and directed Make: Sudhir Cat No: RI/OA/1010 or Shyam/Baliga/Pluto
85Suppy and fixing in replacement of FLP junction boxes 4 way, 100 mm dia asper requirement of all flameproof gascategory CMRI approved all as prer requrenment and directed by Engr In Charge.
86S&F In repairs LED light fitting 1 x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc including hose pipe complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
87Supply and fixing in replacement of flexible metalic hose conduit from junction box to tube light fittings not less than 300mm long of size M20/3/4\\" conduit M x M/FM x M / F 300mm duly approved by CMRI Dhanbad complete all as directed.
88Material and labour for wiring with two single core 6 sqmm multi stranded copper conductor, FRLS, PVC insulated, unsheathed cable, ISI marked, drawn into ERW Steel conduit including 6 sqmm FRLS, PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess making good to the disturbed surfaces to match the existing surfaces complete all as specified and directed. NOTE: Two run of 6 Sqmm submain wiring cable alongwith one run of 6 Sqmm earth wire shall be measured as one length.
89Supply and fix in replacement of spinkler glass bulb type (Standard response) as per IS: 15105/TAC guidelines 79 degree temperature rating pendent type including taking out old unserviceable sprinkler complete all as specified and as directed.
90Taking down of serviceable steel tubing of size 40 to 50 mm from ceiling/wall with connection including cleaning for removal and refixing on same position after completion of ceiling repair work including necessry fitting (saddels, nut bolts, iron angle brakets) complete all as specified and directed.
91Supply and fix in repairs light grade galvanised iron tube 40 mm bore with all fittings for lightening protection pipe or laid in floors/walls complete all as specified and directed.
92Supply and Fixing Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
93Schedule of credit amount of Rs 56,994.00 to be deducted during AOC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58507952
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.44 Lakhs
LAST DATE 03-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Mag No 04 Of Asd At Cod Under Ge (East) Jabalpur
Basic Detail
Tender No 8937/E8
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 21 Nov 2026
Submission Date 03 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value 48.44 Lakhs
Tender Fee 500
EMD 96900
Exemption Available
Document List
81637128-1009-40f1-b7dc-04d3086bfd9a.html
BOQ_895542.xls
TENDER8937.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 11 days
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

81637128-1009-40f1-b7dc-04d3086bfd9a.html

xls

BOQ_895542.xls

pdf

TENDER8937.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender