Health and Family Welfare Government Departments Closing in 12 days TDR #58507210

Tender For Supply Of Walk In Cold Room , Ppgi Puf Filled Panels As Per Spec No 3, 17 , Plain Cement Concrete Concrete Flooring 1:2:4 At Floor Stand (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) , Flooring Of Walkincold Room As Per

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
25.11 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
12 days left
EMD
25200
Bank guarantee accepted
Document Fee
4484
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Supply Of Walk In Cold Room , Ppgi Puf Filled Panels As Per Spec No 3, 17 , Plain Cement Concrete Concrete Flooring 1:2:4 At Floor Stand (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) , Flooring Of Walkincold Room As Per Spec No. 5 , Door With Hinges And Emergency Safety Lock Size 900Mmx2000Mm As Per Spec No 4 , Emergency Alarm With Standard Length Of Cable As Per Spec No 4 , Two 5Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Copper Pipes For Refrigeration Unit Additional Requirement , Drain Pipe Additional Requirement , Cables For Refrigeration Unit Additional Requirement , Control Panel With Switches And Alarm As Per Spec , Vapour Proof Lamp 2Nos With Cables And Switches As Per Spec No 14 , External Light With Cables And Switches As Per Spec No 14 , Digital Data Recorder With Temperature Alarm And Sms Alert Facility For Temperature Alarm As Per Spec No 12, 13 , Ss 304 Grade 14 Gauge Shelves 6X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 5X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 4X3 Feet As Per Spec No 22 , Pvc Blinds For Door Way As Per Spec No 23 , Earthing And Safety Equipments : Supply And Providing Pipe Earthing As Per Is 3043 With 3.60M Long 40Mm Dia B Class Gi Pipe, Gi Funnel With Weld Mesh, Filling Requried Quantity Of Charcoal & Salt Including Construction Of Inspection Chamber With A Bed Concrete Of 1:4:8 Plain Cement Concrete Using 40Mm Broken Stone (10Cm Thick), Brick Work In Cement Mortar 1:6, Plastering The Surface Of Brick Masonry And The Exposed Surface Of Plain Cement Concrete Bed With Cement Mortar 1:4, 12Mm Thick, (The Finished Inside Dimension Shall Be 300X300X300Mm) But Excluding Test Joint, Earth Continuity Conductor To The Plate, And Covering At The Top ( In Ordinary Soil) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/Cables And Giving Connection As Required. 4.00 Mm Copper Conductor (8 Swg) , Door With Hinges And Emergency Safety Lock Size 1000Mmx2000Mm As Per Spec (Not Taken For Evaluation) , Emergency Alarm Cable Additional Requirement (Hooter) , Two 3Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 4Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 6Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 8Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Additional Digital Display Unit As Per Spec With Standard Length Of Cables As Per Spec , Automatic 3 Phase Change Over , Cable For Additional Digital Display Unit , Demolition Of Old Walkincold Room , Mcbs And Mcb Distribution Boards: Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper/Brass Busbar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Colour Washing Etc. As Required. 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb/Isolator/Rccb/Rcbo As Incomer And Sp/Tp Mcb As Outgoing (Ip 42/43) , Supply And Fixing Of Following Rating Residual Current Circuit Breaker Having Earth Leakage Protection (Rccb) As Per Specification As Required 4 Pole 63 Amps. (415 Volts), 100Ma Sensitivity , Supply And Fixing Of Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required. 6 A To 32 A Tp Mcb, C-Curve Mcb , Supply And Fixing Of Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required. 6 A To 32 A Sp Mcb, C-Curve Mcb , Sp Mcb Blanking Plate , Cables And Cabling : Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium /Copper Conductor Cable Conforming To Is 7098 (Part 1) Amended Upto Date. 4 C 16 Sq.Mm Al , Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium /Copper Conductor Cable Conforming To Is 7098 (Part 1) Amended Upto Date. 3 C 10 Sq.Mm Al , Supplying And Making End Termination With Brass Compression Gland And Aluminium/Copper Lugs For Following Size Of Xlpe Insulated Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade As Required-4C 25 Sqmm Sq.Mm Al , Laying And Clamping Of 1No. Pvc Insulated And Pvc Sheathed Armoured Power Cable, 1.1Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages Colour Washing Etc. As Required 4 Core Cable Of Size Exceeding 6Sq.Mm But Not Exceeding 25 Sq.Mm With Company Fabricated Saddles. , External Over Head Canopy For 2 Outdoor Units If The Compressor Units Are Placed In Open Area , Stablizer 15 Kva 3 Phase Wide Range As Per Spec

BOQ

Name of Work:-
Sl. No. Item Description
1PPGI PUF filled panels as per spec no 3, 17
2PCC concrete flooring 1:2:4 at Floor stand (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
3Flooring of walkincold room as per spec no. 5
4Door with hinges and emergency safety lock size 900mmx2000mm as per spec no 4
5Emergency alarm with standard length of cable as per spec no 4
6Two 5KW condensor and evaporator unit with automatic switch and canopy as per spec including fixing and installation
7Copper pipes for refrigeration unit additional requirement
8Drain pipe additional requirement
9Cables for refrigeration unit additional requirement
10Control panel with switches and alarm as per spec
11Vapour proof lamp 2nos with cables and switches as per spec no 14
12External light with cables and switches as per spec no 14
13Digital data recorder with temperature alarm and SMS alert facility for temperature alarm as per spec no 12, 13
14SS 304 Grade 14 gauge Shelves 6x3 feet as per spec no 22
15SS 304 Grade 14 gauge Shelves 5x3 feet as per spec no 22
16SS 304 Grade 14 gauge Shelves 4x3 feet as per spec no 22
17PVC blinds for door way as per spec no 23
18EARTHING AND SAFETY EQUIPMENTS : Supply and providing pipe earthing as per IS 3043 with 3.60m long 40mm dia B class GI pipe, GI funnel with weld mesh, filling requried quantity of charcoal & salt including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40mm broken stone (10cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12mm thick, (the finished inside dimension shall be 300x300x300mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top ( in ordinary soil)
19Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required. 4.00 mm copper conductor (8 SWG)
20Door with hinges and emergency safety lock size 1000mmx2000mm as per spec (Not taken for evaluation)
21Emergency alarm cable additional requirement (hooter)
22Two 3KW condensor and evaporator unit with automatic switch and canopy as per spec including fixing and installation
23Two 4KW condensor and evaporator unit with automatic switch and canopy as per spec including fixing and installation
24Two 6KW condensor and evaporator unit with automatic switch and canopy as per spec including fixing and installation
25Two 8KW condensor and evaporator unit with automatic switch and canopy as per spec including fixing and installation
26Additional digital display unit as per spec with standard length of cables as per spec
27Automatic 3 phase change over
28Cable for additional digital display unit
29Demolition of old walkincold room
30MCBs AND MCB DISTRIBUTION BOARDS: Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper/brass busbar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc. as required. 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB as outgoing (IP 42/43)
31Supply and fixing of following rating residual current circuit breaker having earth leakage protection (RCCB) as per specification as required 4 pole 63 amps. (415 Volts), 100mA sensitivity
32Supply and fixing of following rating, 10 KA, Miniature circuit breakers of the following series as required. 6 A to 32 A TP MCB, C-CURVE MCB
33Supply and fixing of following rating, 10 KA, Miniature circuit breakers of the following series as required. 6 A to 32 A SP MCB, C-CURVE MCB
34SP MCB blanking plate
35CABLES AND CABLING : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4 C 16 Sq.mm Al
36Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3 C 10 Sq.mm Al
37Supplying and making end termination with brass compression gland and aluminium/Copper lugs for following size of XLPE insulated PVC sheathed aluminium conductor cable of 1.1 kV grade as required-4c 25 sqmm Sq.mm Al
38Laying and clamping of 1no. PVC insulated and PVC sheathed armoured power cable, 1.1KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages colour washing etc. as required 4 core cable of size exceeding 6sq.mm but not exceeding 25 sq.mm with company fabricated saddles.
39External over head Canopy for 2 outdoor units if the compressor units are placed in open area
40Stablizer 15 KVA 3 phase wide range as per spec Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58507210
AUTHORITY Government Departments
TENDER VALUE 25.11 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Kerala Medical Services Corporation Limited
Work Description Tender For Supply Of Walk In Cold Room , Ppgi Puf Filled Panels As Per Spec No 3, 17 , Plain Cement Concrete Concrete Flooring 1:2:4 At Floor Stand (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) , Flooring Of Walkincold Room As Per Spec No. 5 , Door With Hinges And Emergency Safety Lock Size 900Mmx2000Mm As Per Spec No 4 , Emergency Alarm With Standard Length Of Cable As Per Spec No 4 , Two 5Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Copper Pipes For Refrigeration Unit Additional Requirement , Drain Pipe Additional Requirement , Cables For Refrigeration Unit Additional Requirement , Control Panel With Switches And Alarm As Per Spec , Vapour Proof Lamp 2Nos With Cables And Switches As Per Spec No 14 , External Light With Cables And Switches As Per Spec No 14 , Digital Data Recorder With Temperature Alarm And Sms Alert Facility For Temperature Alarm As Per Spec No 12, 13 , Ss 304 Grade 14 Gauge Shelves 6X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 5X3 Feet As Per Spec No 22 , Ss 304 Grade 14 Gauge Shelves 4X3 Feet As Per Spec No 22 , Pvc Blinds For Door Way As Per Spec No 23 , Earthing And Safety Equipments : Supply And Providing Pipe Earthing As Per Is 3043 With 3.60M Long 40Mm Dia B Class Gi Pipe, Gi Funnel With Weld Mesh, Filling Requried Quantity Of Charcoal & Salt Including Construction Of Inspection Chamber With A Bed Concrete Of 1:4:8 Plain Cement Concrete Using 40Mm Broken Stone (10Cm Thick), Brick Work In Cement Mortar 1:6, Plastering The Surface Of Brick Masonry And The Exposed Surface Of Plain Cement Concrete Bed With Cement Mortar 1:4, 12Mm Thick, (The Finished Inside Dimension Shall Be 300X300X300Mm) But Excluding Test Joint, Earth Continuity Conductor To The Plate, And Covering At The Top ( In Ordinary Soil) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/Cables And Giving Connection As Required. 4.00 Mm Copper Conductor (8 Swg) , Door With Hinges And Emergency Safety Lock Size 1000Mmx2000Mm As Per Spec (Not Taken For Evaluation) , Emergency Alarm Cable Additional Requirement (Hooter) , Two 3Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 4Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 6Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Two 8Kw Condensor And Evaporator Unit With Automatic Switch And Canopy As Per Spec Including Fixing And Installation , Additional Digital Display Unit As Per Spec With Standard Length Of Cables As Per Spec , Automatic 3 Phase Change Over , Cable For Additional Digital Display Unit , Demolition Of Old Walkincold Room , Mcbs And Mcb Distribution Boards: Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper/Brass Busbar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Colour Washing Etc. As Required. 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb/Isolator/Rccb/Rcbo As Incomer And Sp/Tp Mcb As Outgoing (Ip 42/43) , Supply And Fixing Of Following Rating Residual Current Circuit Breaker Having Earth Leakage Protection (Rccb) As Per Specification As Required 4 Pole 63 Amps. (415 Volts), 100Ma Sensitivity , Supply And Fixing Of Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required. 6 A To 32 A Tp Mcb, C-Curve Mcb , Supply And Fixing Of Following Rating, 10 Ka, Miniature Circuit Breakers Of The Following Series As Required. 6 A To 32 A Sp Mcb, C-Curve Mcb , Sp Mcb Blanking Plate , Cables And Cabling : Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium /Copper Conductor Cable Conforming To Is 7098 (Part 1) Amended Upto Date. 4 C 16 Sq.Mm Al , Supply Of Following Size 1.1 Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Aluminium /Copper Conductor Cable Conforming To Is 7098 (Part 1) Amended Upto Date. 3 C 10 Sq.Mm Al , Supplying And Making End Termination With Brass Compression Gland And Aluminium/Copper Lugs For Following Size Of Xlpe Insulated Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade As Required-4C 25 Sqmm Sq.Mm Al , Laying And Clamping Of 1No. Pvc Insulated And Pvc Sheathed Armoured Power Cable, 1.1Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages Colour Washing Etc. As Required 4 Core Cable Of Size Exceeding 6Sq.Mm But Not Exceeding 25 Sq.Mm With Company Fabricated Saddles. , External Over Head Canopy For 2 Outdoor Units If The Compressor Units Are Placed In Open Area , Stablizer 15 Kva 3 Phase Wide Range As Per Spec
Basic Detail
Tender No KMSCL/EP/607(R)/2026
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 12 Nov 2026
Submission Date 26 Nov 2026
Open Date 28 Nov 2026
Finance
Tender Value 25.11 Lakhs
Tender Fee 4484
EMD 25200
Exemption Available
Document List
576521fe-5f99-4d35-a0b5-a81989f5d8d0.html
BOQ_1517138.xls
Supplierdetails.xls
Tendernotice_1.pdf
WalkinColdRoom.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

576521fe-5f99-4d35-a0b5-a81989f5d8d0.html

xls

BOQ_1517138.xls

xls

Supplierdetails.xls

pdf

Tendernotice_1.pdf

pdf

WalkinColdRoom.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender