Tender For Providing Of Traffic Signal System At Tanda Road Dosarka Distt. Hoshiarpur.
Tender Value
14.67 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
13 days left
EMD
29346
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshiarpur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Of Traffic Signal System At Tanda Road Dosarka Distt. Hoshiarpur.
BOQ
| Sl. No. | Item Description |
| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority :- EXECUTIVE ENGINEER MECHANICAL DIVISION PWD B&R JALANDHAR Name of Work:- Providing of Traffic Signal System at Tanda Road Dosarka Distt. Hoshiarpur. Contract No: ELECTRICAL WORKS Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Design, Supply, testing & commissioning of 4G Modem & SIM Card based Data Receiving & Sending Communication Devices working on Serial/12C/Modbus TCP/ Ethernet TCP/IP protocols to be connected with separate City Signal Dashboard & Cloud Server System having following features and compatible for receving & sending data of Traffic Signal Controllers Systems at various junctions. The device should allow for the following tasks:i. Register & Login for the Application to communicate with the existing Controller Systemsii. Location of Traffic Signal Systemsiii. Sending Programs and Data to the Controller Stationsiv. Live display of Power Supply/Connectivity/Signal System UP or failure statusv. v. Live Display of Traffic Signal Lights working with 4g time lagvi. App notification trigger to various Officials for Signal Failuresvii. Traffic Synchronisation Status, if anyviii. Back-end admin panel for Maintenance Officials to pull out historical data of Signal Working |
| 3 | ix. Fully customized Reporting modulex. Switching ON/OFF Traffic Signalsxi. Report for Special events at Traffic Signal Systemxi. Notification to concerned Officers and Contractors for failure of Traffic Signal Supply. Multiple alerts shall be configurable The device should be compatible with existing Traffic Signal Controllers complete in all respects as approved by Engineer-in-charge at site. |
| 4 | S/E of Intelligent Motherboard Controller compatible with GSM Model and facility for connectivity to control room, Vehicle Actuation Cameras and ATCS mode for Vehicle Management with Live SKIP Timer and Camera Integration. The detailed specifications of the controller are as below: -HARDWAREMemory: NOVRAM with built in battery battery backupSystem clock: Calendar clock (RTC) with minimum 5 years Battery back-up clock Programming Facility Through external Engineering Application WITH BLUETOOTH operationFEATURESNumber of signals Minimum 16 signals group should be programmable as either vehicular or Pedestrian groups. Additional Programmable dummy groups as desirable.Number of stage: 16 stagesOutputs The Motherboard should have Connector to connect further to the Sub Control UnitVehicle Actuation: RS232/RS485/DI ports should be provided for communication with sensors and inbuilt software should be provided for Vehicle Actuation Facility so as to run the Traffic Signal in Vehicle Actuation Mode. The control system should have facility for working in Vehicle Actuation Mode. It should sense the inputs from various existing Traffic Sensors and adjust the Traffic Signals according to the intensity of traffic on all four/six roads of the Traffic Junction. |
| 5 | The controller should be programmable so as to work in Vehicle Actuation with Cameras/Sensors etc at a particular time of the day/whole day/particular date etc. The controller should be integrated with Vehicle Detector cards, Vehicle Sensors cards etc. complete in all respects.Area Traffic control compatibility Controller should have live Ethernet/internet port for connecting to the area traffic control centre. Live port should be provided and testing / demo should be done /displayed before commissioning of controller No hardware/software should be required to be provided up to controller at later stage when connection is required for areacontroller.ENVIRONMENTAL FEATURESOperating voltage: 24VDC Temperature 0C to 70 C Relative Humidity Max 95% The controller shall be installed in the pedestal and also making connections to it with all the incoming and outgoing cables as per site requirement. complete in all respects as approved by Engineer-in-charge at site |
| 6 | Design, Manufacture, Supply, Wiring & Commissioning of Traffic Light sub control unit with facility of Output Isolation Through solid state devices with zero cross output solid state switching isolated from control circuit by optical isolation in male female plug type single module. The solid state device should not be used for switching ON/OFF of more than 2 Nos. LED Lamps including shall be installed in the pedestal and also making connections to it with all the incoming and outgoing cables as per site requirement. The Sub Control unit shall be provided with Overload/over voltage protection and modular plug-in type system shall be provided for easy maintenance. The Unit shall also be provided with Indicators for Operator use complete in all respects with continuous input voltage current control & overload. complete in all respects as approved by Engineer-in-charge at site. |
| 7 | Supply and erection of IP-65 Approved One Aspect signal Head LED Light Assembly of 300mm dia fabricated from polycarbonate materials die moulded Complete in all respects of nominal size 380 x 350mm complete in all respect with LED type traffic signals glasses. The visor shall be fabricated from UV Stabilised HDPE Materials of length min 254 mm depth and tilted 50 along the geometrix axis from the back side to front end as per IS 7537-1974 and the assemblies shall have provision for mounting of pole to permit directional adjustments. The lenses of red, amber or green colour shall be fabricated from 5mm dia LED's of light intensity of minimum 5000 mcd and the electronic switching circuit wired on printed circuit board of epoxy material with transparent covering glass of polycarbonate materials. LED Viewing Angle should be 23 degree with max. Forward Current as 20 mA & lamp shall be visible from 400m under normal atmospheric conditions (Conforming to IEC60529) a) Glass with a minimum of 190 LED's of Red/Amber colour, or b). Glass with a minimum of 66 LED's of Green colour in Arrow/Walking Man shape. complete in all respects as approved by Engineer-in-charge at site. |
| 8 | Supply and erection of steel tubular pole 8.70mtr long and in two steps-bottom portion MS Pipe B class ISI mark 6mtr long 150mm dia and top portion MS pipe B class ISI mark gauge 3mtr long of 125mm dia with provision for the erection of bracket fabricated from 50mm dia M.S. pipe of A class upto 4mtr long, P type arm suitable for fixing of traffic lights and a 200mm dia round M.S. plate of 6mm thickness to be provided at the bottom of the pole. The pole will be erected 1.5mtr below ground level with 1:3:6 cement concrete mixture. The joining of the pole will be done so as to provide maximum supports to the joints including the cost of the all labour and material required for the job. The pole will also be provided with suitable reinforced plastic pole top for the safety of cables etc. The mounting arrangement of the lanterns should be made in such a way that signal heads can be adjusted as per required direction of the site complete in all respects as approved by Engineer-in-charge at site. |
| 9 | Design & Supply of Smart Android based App for Traffic Signals to control all important parameters such as Programs, Timings, Vehicle Actuation parameters, Live Signal Working, Manual Control, Smart Icon etc shall be transferred and configurable from Smart Android APP The following parameters shall be programmable from anywhere in Jalandhar city:Live Simulation of Traffic Signal actual working at siteAdd, edit or delete data of Programs and sets in the ControllerCheck working of CamerasCheck working of DowncountersMains Power StatusBattery Status - 24vbattery ststaus-12vLogs of all important traffic datacomplete in all respects as approved by Engineer-in-charge at site. |
| 10 | Supply and erection of PVC under ground copper conductor 1.55q mm size armoured cable 14 core (loose in pipe) suitable for A.T.C. signals 660/1100 volts conforming to ISS 1554-1998 laid in existing pipe or in trench including cost of labour material required for the job. complete in all respects as approved by Engineer-in-charge at site. |
| 11 | Supply and erection of PVC under ground copper conductor 1.55q mm size armoured cable 8 core (loose in pipe) sultable for A.T.C. signals 660/1100 volts conforming to ISS 1554-1998 laid in existing pipe or in trench including cost of labour material required for the job. complete in all respects as approved by Engineer-in-charge at site. |
| 12 | Providing trenchless boring by Manual means or Machine slit cutting through manual means/machine cut 4\\" deep with recarpeting with Tar under metal surface for road crossing & reconditioning the same after laying of pipe to complete the job as required at site complete in all respects as approved by Engineer-in-charge at site. |
| 13 | Supply and erection of PVC copper conductor 6 core 1mmsq. Wire complete in all respects including making connections complete in all respects as approved by Engineer-in-charge at site. |
| 14 | Supply and erection of 24V 200Amp-Hr Power Pack with Sealed Maintenance free Batteries complete in all respects with connecting terminals etc. The Batteries should be mounted in existing Panels/MS Boxes and duly provided with special arrangement so as to prevent thefts. complete in all respects as approved by Engineer-in-charge at site. |
| 15 | Supply and erection of Heavy Duty 24V cum 12V DC Rectifier of upto 20Ampere Capacity for extra charging of 24V DC 300AH Batteries complete in all respects as approved by Engineer-in-charge at site. |
| 16 | Supply & Erection of Outdoor grade Traffic Signal Panel of approximate size 900 X 600 X 600mm (Nominal) fabricated from 1.6mm thick MS sheet and required supporting members of MS angle Iron/ MS Flat duly painted & with separate compartments for batteries & Control System etc. Facility for theft proof installation of Batteries shall also be provided in the pedestal. The pedestal box should have 4 legs 70cm long of 35 x35x 5mm angles iron and grouted 30 cm below ground level in cement concrete mixture complete in all respects with provision for cable entry etc. complete in all respects as approved by Engineer-in-charge at site. |
| 17 | Supply and erection of Industrial Grade Intelligent 1400W Battery Charger Systems provided with intelligent float charging circuit for total capacity of 300Ahbatteries @ 24V and 1 No 12V 42Ah. The system shall be provided with low/high voltage cut arrangement so as to ensure that in the event of continuous power failure, the batteries do not get deep discharged/ over charged. The charger shall be fabricated from weather resistant heavy duty Power Diodes, Switching FETs/Transistors assembled on Aluminium Heat Sink units, charging ciruicts and metering to show Voltage levels etc. The Charger should also have intgerated 12V Charging System. The system shall be housed in existing box. The cost shall include required wiring of the same. complete in all respects as approved by Engineer-in-charge at site. |
| 18 | Supply and erection of MS Pole 100mm dia A Class ISI Mark 6.1m long duly welded for traffic signal head assemblies as requirement at site. The pole should be painted with primer red oxide and two coats of golden yellow synthetic enamel paint. The pole is to be erected 1.00m below ground level in 1:3:6 cement concrete mixture. The provision for cable entry should also be made complete in all respects with all labour and material required for the job including welding of 200 x 200 x 5mm M.S. Plate at the bottom and erection of the same in 1:3:6 cement concrete foundation. The pole top canopy fabricated from Reinforced Fiber Plastics in White Colour shall be mounted on the Top of the pole. The pipe shall be of reputed manufacturing company complete in all respects as approved by Engineer-in-charge at site. |
| 19 | Supply & Erection of Multi-coloured Red & Green coloured Microprocessor based Down Counter Timer for computerized ATC Signals with Ethernet port to display the live timings of Red remaining time in Red Colour and Straight Green or Side Green timings independently in Green colour as per requirement of Traffic Signal flow. The down-counters should have the following specifications:a) Number of digits: 2% digitsb) Number of Segment per digit: 7 segmentsc) Channels 3/4 (red/Green/Side Green1/2) as per Site requirementd) Minimum Number of LEDs per digit: 420 LEDs per digite) Minimum total: 600 LEDs per Downcounter Timerf) Minimum height of Digit: 250mmg) Ports for receiving Signal: Ethernet/Modbus TCP-IP & Digital Inputsh) Communication Protocol: Live Modbus-TCP/IP/DIi) Colour of Display - Red when Red light and Green when Green lightThe Display should have a capability of counting down of Red/green times duly synchronized with multiprogrammable microprocessor controller. The system should itself display the changed programmable timings of the controller and it should adjust to changed Red/Green timings in the subsequent cycles. The job also includes synchronizing with existing Traffic Signal system and the cost of calibration of the system including the cost of material etc. complete in all respects as approved by Engineer-in-charge at site. |
| 20 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 21 | Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.) |
| 22 | COPPER EARTHING: |
| 23 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 24 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 25 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 26 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 27 | XLPE INSULATED ARMOURED CABLES (LOOSE): |
| 28 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 29 | Overall size 10sq.mm (4Core) Armoured (Loose) |
| 30 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: |
| 31 | CUBICAL PEDESTAL: |
| 32 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 33 | Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm Total in Figures 1467278.0 1467278.0 INR Fourteen Lakh Sixty Seven Thousand Two Hundred & Seventy Eight Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
TodayNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender