Tender For Installation And Energisation Of Kendumal-I & Ii Revival And Reinforcement R.L Project In Sundaragada Block Of Sundaragada District
Tender Value
18.94 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
2 days left
EMD
18944
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sundargarh → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation And Energisation Of Kendumal-I & Ii Revival And Reinforcement R.L Project In Sundaragada Block Of Sundaragada District
BOQ
| Sl. No. | Item Description |
| 1 | KENDUMAL-I |
| 2 | Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. |
| 3 | Excavation in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels, within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods and stacking rubble or spreading and leveling within the site as the case may be etc; complete.asper direction of the Engineer-in-charge.(Mechanical 60% & Mannual 40%) |
| 4 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 5 | Cement concrete (1:4:8) with 4cm size h.g.b. crusher broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. |
| 6 | Brick work with FLY ASH. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth . complete as per the Engineer-incharge. |
| 7 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.a) walls and fins including attached pillasters |
| 8 | Supply, fitting & placing uncoated HYSD Bar reinforcement complete as per drawing & technical specification including cost, taxes, conveyance charges of etc. complete as directed by the Engineer-incharge. |
| 9 | R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 10 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 11 | Colour washing two coats with stone Lime including colouring |
| 12 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 13 | Labour charges & Cost of PVC Pipe for jointing the pipes with solvent cement including fitting and fixing of required no. of PVC Tee . including cost Solvent Cement, Transportation of Pipe including conveyance pipe from village to worksite 200mm dia PVC Class-I Pipe |
| 14 | Labour charges & Cost of PVC Pipe for jointing the pipes with solvent cement including fitting and fixing of required no. of PVC Tee . including cost Solvent Cement, Transportation of Pipe including conveyance pipe from village to worksite 160mm dia PVC Class-I Pipe |
| 15 | Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. A) Hard Soil |
| 16 | Filling in F&P with excavated materials including well watered and rammed.in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels, within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods and stacking rubble or spreading and leveling within the site as the case may be etc; complete.asper direction of the Engineer-in-charge.(Mechanical plus mannual |
| 17 | Cost of 200 mm pvc end cap |
| 18 | Cost of 160 mm pvc end cap |
| 19 | Cost of 200mm x 200mm x 160 mm PVC Tee |
| 20 | Cost of 160 mm dia PVC coupler |
| 21 | Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement. |
| 22 | Cost of 200 mm dia PVC coupler |
| 23 | Supply of T & P Kit comprising of hand gloves- 1 pair, tester - 1 no, 8 inch cutting plier - 1 no, 12 inch sly wrench -1 no, 12 inch Screw driver - 1no , 24/27 & 21/23 De spanner -2 nos, 24/27 & 21/23 Ring spanner -2 nos (Taparia) with Bag |
| 24 | KENDUMAL-II |
| 25 | Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. |
| 26 | Excavation in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels, within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods and stacking rubble or spreading and leveling within the site as the case may be etc; complete.asper direction of the Engineer-in-charge.(Mechanical 60% & Mannual 40%) |
| 27 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 28 | Cement concrete (1:4:8) with 4cm size h.g.b. crusher broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge. |
| 29 | Brick work with FLY ASH. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth . complete as per the Engineer-incharge. |
| 30 | Brick work with FLY ASH. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in super structureetc. complete as per the Engineer-incharge. |
| 31 | Cement concrete (1:2:4) with 12mm size black h.g.b. crusher broken chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 32 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.a) floor and roof slab, balconies, projecting sun shades and chajjas |
| 33 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.a) RCC lintels |
| 34 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.a) foundation , plinth band and footings bases of columns mass concrete precastslabs etc |
| 35 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.a) walls and fins including attached pillasters |
| 36 | Supply, fitting & placing uncoated HYSD Bar reinforcement complete as per drawing & technical specification including cost, taxes, conveyance charges of etc. complete as directed by the Engineer-incharge. |
| 37 | R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 38 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 39 | White washing three coats with Stone lime |
| 40 | Colour washing two coats with stone Lime including colouring |
| 41 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 42 | M.S. pannel door single leafed with M.S. frame overall size includingframe of height (1.0 x2.0)mt. width for door and shutter of 18 gauge CR sheet pannel as per approved size & specification etc. complete including cost of all materials fitting and fixing the door etc. complete as per the direction of the Engineer in charge. |
| 43 | Cement washing 2 coats per 1 Sqm. |
| 44 | 2.5cm thick A.S. flooring with C.C. (1:2:4) using 12mm size black hard granite crusher broken chips of approve quality for approve querry including water and curring with cost taxes royalty and conveyance charges of all material toworksite and supply of all labour and T&P required for the work complete as directed by the Engineer in charge. |
| 45 | Dry brick khoa rammed to 4” size in flooring |
| 46 | Painting red oxide primer for priming over iron work including cost of labour etc. complete as per direction of the Engineer in charge. |
| 47 | Painting two coats with any approved paints |
| 48 | Labour charges & Cost of PVC Pipe for jointing the pipes with solvent cement including fitting and fixing of required no. of PVC Tee . including cost Solvent Cement, Transportation of Pipe including conveyance pipe from village to worksite 200mm dia PVC Class-I Pipe |
| 49 | Labour charges & Cost of PVC Pipe for jointing the pipes with solvent cement including fitting and fixing of required no. of PVC Tee . including cost Solvent Cement, Transportation of Pipe including conveyance pipe from village to worksite 160mm dia PVC Class-I Pipe |
| 50 | Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. A) Hard Soil |
| 51 | Filling in F&P with excavated materials including well watered and rammed.in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels, within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods and stacking rubble or spreading and leveling within the site as the case may be etc; complete.asper direction of the Engineer-in-charge.(Mechanical plus mannual |
| 52 | 12.5 HP Centrifugal Monoblock pumpset 20mtr. Head to discharge 1700 LPM |
| 53 | Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 15 HP with 20 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp & no volt coil with electronic timer |
| 54 | 63 Amp. 400 Volt.T.P. main switch (EPM Standard) |
| 55 | 4 KVR Capacitor |
| 56 | Base frame of motor |
| 57 | Cost of base plate for control panel |
| 58 | 3 x 16mm2 T.D. Cable laying underground including excavation of earth sand filling etc.complete |
| 59 | 2.5 mm2 s/s flat. Cable laying underground including excavation of earth sand filling etc.complete |
| 60 | 100 mm dia. G.I. Pipe |
| 61 | 100mm C.I. Foot Valve |
| 62 | 100 mm dia. G.I.Flange |
| 63 | 100 mm dia. G.I. Bend |
| 64 | 100mm C.I. N.R. Valve |
| 65 | Cost of 100 mm dia GI Nipple |
| 66 | Cost of 100mm dia GI Socket |
| 67 | Cost of 200 mm pvc end cap |
| 68 | Cost of 160 mm pvc end cap |
| 69 | Cost of 200mm x 200mm x 160 mm PVC Tee |
| 70 | Cost of 160 mm dia PVC coupler |
| 71 | 200mm x110 mm PVC reducing socket |
| 72 | 110 mm PVC FTA |
| 73 | 50mm C.I. Air Release Valve with saddle,riser pipe,bend etc for proctection tank |
| 74 | Cost of 100X100X25mm G.I. tee, Bend, Bulb Valve for Priming & welding |
| 75 | Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement. |
| 76 | Cost, supplyuing of M.S Nuts and Bolts, packing etc (1/2\\" to 5/8\\") |
| 77 | Motor Hood |
| 78 | Labour charges for installation of. Motors 1nos. including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve and other fitting materials like nut bolt,leather packing etc with cutting, welding inluding electricals installation etc. complete. |
| 79 | Supply of T & P Kit comprising of hand gloves- 1 pair, tester - 1 no, 8 inch cutting plier - 1 no, 12 inch sly wrench -1 no, 12 inch Screw driver - 1no , 24/27 & 21/23 De spanner -2 nos, 24/27 & 21/23 Ring spanner -2 nos (Taparia) with Bag |
| 80 | Construction of 3 phase 11 KV Line as per REC standard confirming to RE Rules 1956 with 400Kg. 10 mtrs.long PSC Pole ( cost excluded ) support in 50Mtrs. Span 55 sqm . AAA Insulated covered conductor, 11 KV \\"V\\" cross arm with required nos.of 11KV T &C disc.Insulators and 11KV Pin insulator,carping & padding of poles, danger board at each pole,anticlimbing devices. Stay set at each bending Point and double stay at end point with 18mm G.I. H.T. Stay, concreting of stay with anchor plate,guarding at road crossing etc. including cost of materials,labours, transportation, inspection and commissionng etc. complete. |
| 81 | LT Line with 3x35+1x25mm² AB Cable without pole (30 mtr span) |
| 82 | Construction and errection of 11/0.4KV , D.P. mounted transformer substation of different capacity confirming to RE Rules 1956 mounted on 2.44mtr. Long structure , supported in 400 Kg 10mtrs. Long PSC Poles, Transformer hard channel and top channel made of 2.8mtrs. long 100X50X6 mm M.S. Channel, Transformer belting on 2.8 mtrs. long 50X50X5 mm M.S. angle (all REC.SPN.Std F-3) with all accessories like3 poles 11 K.V. HG Fuse (F-5) & AB Switches (F-9) both mounted on 2.5 mtrs. long 75X40X6 mm M.S. Channel and supported by 1mtr. long 50X50X5 mm M.S. angle with 3nos. 11 KV lightening Arrestors and distribution box, Pipe earthing(F-2), including cost of 50 sqmm. 3.5 core PVC Cable carping and padding of poles, danger board at each poles, Anti climbing Devices & all other necessary fitting i.e. required size nuts & bolts, brackets Cable sockets etc., construction of barbed wire fencing with double leaf MS Gate with metal spreading, including cost of all materials , labour transportation complete with liasoning for testing inspection & commissioning ( including 25 KVA Transformer 11 / 0.4 KV level - II, Star - II and excluding cost of PSC pole ) |
| 83 | 10 mtr 400kg PSC pole |
| 84 | 9 mtr 300 kg PSC pole |
| 85 | Boundry wall of Sub-Station (size 15' x 10') with Sand filling and metal spreading, Fixing of Iron gril gate of double doors of 01 mt each to be fixed in proper size of briks. The gate is to be painted with silver coloured enamel paints and lock & key arrangements to be provided etc. |
| 86 | S.C Distribution box for LT line |
| 87 | Internal wiring of Pump house |
| 88 | Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduite pipe, No.6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation including fixing of TD cable inside the earth trench as per direction of Engineer-in-charge.. |
| 89 | Electrical Earthing including all materials as per the direction of the Engineer-incharge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender