Tender For Infrasructure Development Of Ranipur Jharial At Bangomunda Block, Balangir (Phase-Iii)
Tender Value
13.54 Crore
Estimated cost
Bid Submission
27 Nov 2026
6 days left
EMD
13.54 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Infrasructure Development Of Ranipur Jharial At Bangomunda Block, Balangir (Phase-Iii)
BOQ
| Sl. No. | Item Description |
| 1 | Excavation of foundation in hard rock (Granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per the specification approved by the department etc. complete as per the direction of Engineer-in-charge. |
| 2 | Boundary Wall(Main Temple) |
| 3 | Rani Temple Boundary Wall |
| 4 | Security Kiosk |
| 5 | Paved Road(Rani Temple) |
| 6 | Paved Road(Indralath) |
| 7 | Disposal of building rubbish / malba /rock/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping site or as approved /directed by Engineer-in-charge, including all lead and lifts involved, labour, etc. complete as per the direction of Engineer-in-charge. |
| 8 | Paved Road(Rani Temple) |
| 9 | Paved Road (Indralath Temple) |
| 10 | EARTHWORK EXCAVATION :- Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches or drains, including dressing of sides and ramming of bottoms and dewatering wherever required, including all lifts, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km including cost of all labours/ equipments, sundries and T&P etc all complete as per the direction of Engineer-in-charge |
| 11 | Entrance Gateway |
| 12 | Heritage Road |
| 13 | Drainage |
| 14 | Security Kiosk (Rani Temple) |
| 15 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 16 | Yatri Nivas |
| 17 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 18 | Entrance Gateway |
| 19 | Yatri Nivas |
| 20 | Drainage |
| 21 | Security Kiosk(Rani Temple) |
| 22 | Filling at Barrowed excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 23 | Boundary Wall |
| 24 | Rani Temple Boundary Wall |
| 25 | Supplying of filling sand in foundation and over areas including watering,ramming, consolidating and dressing, labours, tools, taxes etc., all complete as per the specification and direction of Engineer-In-charge. |
| 26 | Entrance Gateway |
| 27 | Yatri Nivas |
| 28 | Heritage Road |
| 29 | Drainage |
| 30 | Boundary Wall(Main Temple) |
| 31 | Rani Temple Boundary Wall |
| 32 | Security Kiosk |
| 33 | Paved Road(Rani Temple) |
| 34 | Paved Road(IndralathTemple) |
| 35 | Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. |
| 36 | Entrance Gateway |
| 37 | Yatri Nivas |
| 38 | Heritage Road |
| 39 | Drainage |
| 40 | Boundary Wall(Main Temple) |
| 41 | Rani Temple Boundary Wall |
| 42 | Rani Temple Boundary Wall |
| 43 | Paved Road(Rani Temple) |
| 44 | Paved Road(Rani Temple) |
| 45 | Providing and laying plain cement concrete 1:3:6 (1 cement:3 sand: 6 stone agregate 12mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring ,shuttering etc.complete all depth and height. |
| 46 | Yatri Nivas |
| 47 | Providing and laying cement concrete 1:2:4 on walls (any thickness), including the cost of centering,shuttering and finishing :including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer -in-charge |
| 48 | Entrance Gateway |
| 49 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment). |
| 50 | Yatri Nivas |
| 51 | Security Kiosk (Rani Temple) |
| 52 | First class Fly Ash masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 53 | Yatri Nivas |
| 54 | Boundary Wall(Main Temple) |
| 55 | Rani Temple Boundary Wall |
| 56 | Security Kiosk (Rani Temple) |
| 57 | First class Fly Ash masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 58 | Ground Floor |
| 59 | Yatri Nivas |
| 60 | Boundary Wall(Main Temple) |
| 61 | Rani Temple Boundary Wall |
| 62 | Security Kiosk (Rani Temple) |
| 63 | First Floor |
| 64 | Yatri Nivas |
| 65 | Entrance Gateway |
| 66 | Terrace Floor |
| 67 | Yatri Nivas |
| 68 | First class Fly Aash masonry using bricks of size 25m. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 69 | Ground Floor |
| 70 | Yatri Nivas |
| 71 | First Floor |
| 72 | Yatri Nivas |
| 73 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
| 74 | a) Footings :- |
| 75 | Yatri Nivas |
| 76 | Entrance Gateway |
| 77 | Heritage Road |
| 78 | Drainage |
| 79 | Boundary Wall(Main Temple) |
| 80 | Rani Temple Boundary Wall |
| 81 | Security Kiosk (Rani Temple) |
| 82 | RCC Wall |
| 83 | Heritage Road |
| 84 | Drainage |
| 85 | b) Column up to plinth :- |
| 86 | Yatri Nivas |
| 87 | Entrance Gateway |
| 88 | Boundary Wall(Main Temple) |
| 89 | Security Kiosk (Rani Temple) |
| 90 | c) Plinth beam :- |
| 91 | Yatri Nivas |
| 92 | Entrance Gateway |
| 93 | Boundary Wall (Main Temple) |
| 94 | Rani Temple Boundary Wall |
| 95 | Security Kiosk (Rani Temple) |
| 96 | d) Lintel |
| 97 | Ground Floor |
| 98 | Yatri Nivas |
| 99 | Security Kiosk (Rani Temple) |
| 100 | Coping |
| 101 | Boundary Wall (Rani Temple) |
| 102 | Boundary Wall (Main Temple) |
| 103 | First Floor |
| 104 | Yatri Nivas |
| 105 | e) Column in S.S :- |
| 106 | Ground Floor |
| 107 | Yatri Nivas |
| 108 | Entrance Gateway |
| 109 | Rani Temple Boundary Wall |
| 110 | Security Kiosk (Rani Temple) |
| 111 | First Floor |
| 112 | Yatri Nivas |
| 113 | Entrance Gateway |
| 114 | Terrace Floor |
| 115 | Yatri Nivas |
| 116 | f) Beam |
| 117 | Ground Floor |
| 118 | Yatri Nivas |
| 119 | Security Kiosk (Rani Temple) |
| 120 | First Floor |
| 121 | Entrance Gateway |
| 122 | Yatri Nivas |
| 123 | Terrace Floor |
| 124 | Yatri Nivas |
| 125 | g) Slab |
| 126 | Ground Floor |
| 127 | Yatri Nivas |
| 128 | First Floor |
| 129 | Yatri Nivas |
| 130 | Entrance Gateway |
| 131 | Terrace Floor |
| 132 | Yatri Nivas |
| 133 | Slope Roof |
| 134 | Entrance Gateway |
| 135 | Security Kiosk (Rani Temple) |
| 136 | Double stage Centering |
| 137 | Entrance Gateway |
| 138 | Staircase |
| 139 | Ground Floor |
| 140 | Yatri Nivas |
| 141 | First Floor |
| 142 | Yatri Nivas |
| 143 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL/ Rungta Steel/ Reliable Sponge/ Scan Steel/ SMC Power Generation/Shyam Metalics & Energy (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
| 144 | Ground Floor |
| 145 | Yatri Nivas |
| 146 | Entrance Gateway |
| 147 | Heritage Road |
| 148 | Drainage |
| 149 | Boundary Wall(Main Temple) |
| 150 | Rani Temple Boundary Wall |
| 151 | Security Kiosk (Rani Temple) |
| 152 | Security Kiosk (Rani Temple) |
| 153 | First Floor |
| 154 | Entrance Gateway |
| 155 | Yatri Nivas |
| 156 | Terrace Floor |
| 157 | Yatri Nivas |
| 158 | 12mm cement plaster on external RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. |
| 159 | Ground Floor |
| 160 | Yatri Nivas |
| 161 | Boundary Wall(Main Temple) |
| 162 | Rani Temple Boundary Wall |
| 163 | Security Kiosk (Rani Temple) |
| 164 | First Floor |
| 165 | Entrance Gateway |
| 166 | Yatri Nivas |
| 167 | Terrace Floor |
| 168 | Yatri Nivas |
| 169 | 16mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. |
| 170 | Ground Floor |
| 171 | Yatri Nivas |
| 172 | Boundary Wall(Main Temple) |
| 173 | Rani Temple Boundary Wall |
| 174 | Security Kiosk (Rani Temple) |
| 175 | First Floor |
| 176 | Entrance Gateway |
| 177 | Yatri Nivas |
| 178 | Terrace Floor |
| 179 | Yatri Nivas |
| 180 | 6 mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:4 (1 cement : 4fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. |
| 181 | Ground Floor |
| 182 | Security Kiosk (Rani Temple) |
| 183 | Yatri Nivas |
| 184 | Entrance Gateway |
| 185 | Boundary Wall(Main Temple) |
| 186 | Rani Temple Boundary Wall |
| 187 | First Floor |
| 188 | Yatri Nivas |
| 189 | Entrance Gateway |
| 190 | Terrace Floor |
| 191 | Yatri Nivas |
| 192 | Providing & Fixing of WPC Door Frame size 5\\" x 2.5\\" having density 725kg/m3, make up of virgin polymer, wheat and rice husk fiber and Calcium silicate. 100% water proof, termite proof and fire retardant made of Alstone Chaukhat. The door will be provided with all necessary fitting & fixture of approved hardware and all materials complete as per direction of the Engineer-In-Charge. |
| 193 | Ground Floor |
| 194 | Yatri Nivas |
| 195 | Security Kiosk (Rani Temple) |
| 196 | First Floor |
| 197 | Yatri Nivas |
| 198 | Providing & fixing WPC Door Shutter of thick 30mm having density 660kg/m3 make up virgin polymer with wheat and rice husk fiber. 100% water proof, termite proof and fire retardant made of Alstone WPC Door. The door will be provided with all necessary fitting & fixture of approved hardware and all materials complete as per direction of the Engineer-In-Charge at all floors and all heights. |
| 199 | Ground Floor |
| 200 | Yatri Nivas |
| 201 | Security Kiosk (Rani Temple) |
| 202 | First Floor |
| 203 | Yatri Nivas |
| 204 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 205 | Ground Floor |
| 206 | Yatri Nivas |
| 207 | Security Kiosk (Rani Temple) |
| 208 | First Floor |
| 209 | Yatri Nivas |
| 210 | Terrace Floor |
| 211 | Yatri Nivas |
| 212 | Supplying, fitting and fixing of UPVC openable door with door frames of approved make with 6mm thick glass of approved quality complete with frame,fitting and fixtures etc. |
| 213 | Security Kiosk (Rani Temple) |
| 214 | Providing and fixing Vitrified tile of specified size in floors on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 sand) with neat cement slurry . finishing the joint with epoxy based water proof grout to match the shades of the tiles etc.including cost of all materials,labours & royalties, conveyance ,loading and unloading ,sundries ,T & P etc .complete as per the specification & direction of Engineer-in-charge. Size of tile 600x 600 mm (Full Body Double charge Vitrified tiles) |
| 215 | Ground Floor |
| 216 | Yatri Nivas |
| 217 | First Floor |
| 218 | Yatri Nivas |
| 219 | Providing & laying vitrified tile of specified size in skirting cut from approved make confirming to IS-15622 specifications over 12mm thick cement mortar (1: 3) to proper line and level to a height as per design including cutting to required size and shape, fixing at corners and splays etc. including finishing the joints with epoxy based water proofing grout to match the color and shade of tiles and complete as per the design & drawing with cost of all materials, labour, conveyance T&P etc. All complete as per the direction of Engineer -in-charge. Size of tile 600x 600 mm (Full Body Double charge Vitrified tiles) |
| 220 | Ground Floor |
| 221 | Yatri Nivas |
| 222 | First Floor |
| 223 | Yatri Nivas |
| 224 | Providing and laying Kota Stone Flooring using Kota tiles of area above 0.10 sqm of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tile |
| 225 | GROUND FLOOR |
| 226 | Security Kiosk (Rani Temple) |
| 227 | Providing and laying Kota Stone in Dado/Skirting using kota tiles of area above 0.10 sqm of approved make, quality and colour without any warpage laid over an under layer of 12 mm thick base of cement mortar (1:3) (1 cement: 3 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use. |
| 228 | GROUND FLOOR |
| 229 | Security Kiosk (Rani Temple) |
| 230 | Providing & laying best quality Antiskid Ceramic floor tile of specified size of thickness 8-10mm of approved make confirming to IS-15622 specifications in floor over 20mm thick cement mortar (1:4) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. Including finishing the joints with epoxy based water proofing grout to match the color and shade of tiles complete as per the design & drawing with cost of all materials, labour, conveyance T&P etc. All complete as per the direction of Engineer -in-charge. |
| 231 | GROUND FLOOR |
| 232 | Security Kiosk (Rani Temple) |
| 233 | Yatri Nivas |
| 234 | First Floor |
| 235 | Yatri Nivas |
| 236 | CERAMIC GLAZED WALL TILE FOR TOILET:- Providing and fixing ceramic glazed wall tiles of specified size of thickness 6-10mm conforming to IS: 15622 specifications of approved make and shade, in skirting and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and finishing the joint with epoxy based water proofing grout to match the shade. All complete as per the direction of Engineer-in-charge (Toilet) (Note- Sample of tiles shall be approved before procurement and use) |
| 237 | Yatri Nivas |
| 238 | Security Kiosk (Rani Temple) |
| 239 | First Floor |
| 240 | Yatri Nivas |
| 241 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & Grooving etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 242 | Ground Floor |
| 243 | Yatri Nivas |
| 244 | First Floor |
| 245 | Yatri Nivas |
| 246 | Providing & Applying priming coat with Water base wall primer of approved brand and manufacture on plaster/putty surface as per the instruction of Engineer-In-Charge at all elevations and all heights including all material & labour complete. |
| 247 | Ground Floor |
| 248 | Yatri Nivas |
| 249 | First Floor |
| 250 | Yatri Nivas |
| 251 | Terrace Floor |
| 252 | Yatri Nivas |
| 253 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 254 | Ground Floor |
| 255 | Yatri Nivas |
| 256 | First Floor |
| 257 | Yatri Nivas |
| 258 | Terrace Floor |
| 259 | Yatri Nivas |
| 260 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-charge at all elevations including all material labour complete. |
| 261 | Ground Floor |
| 262 | Yatri Nivas |
| 263 | Heritage Road |
| 264 | Boundary Wall(Main Temple) |
| 265 | Rani Temple Boundary Wall |
| 266 | Repair Of Existing Boundary Wall (Indralath Temple) |
| 267 | First Floor |
| 268 | Yatri Nivas |
| 269 | Terrace Floor |
| 270 | Yatri Nivas |
| 271 | Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\"Royale Shyne\\" of Asian Paints or equivalent of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. |
| 272 | Ground Floor |
| 273 | Yatri Nivas |
| 274 | Security Kiosk (Rani Temple) |
| 275 | First Floor |
| 276 | Yatri Nivas |
| 277 | Terrace Floor |
| 278 | Yatri Nivas |
| 279 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer - In-Charge at all floors and all heights including all material & labour complete. |
| 280 | Ground Floor |
| 281 | Yatri Nivas |
| 282 | Repair Of Existing Boundary Wall (Indralath Temple) |
| 283 | Boundary Wall(Main Temple) |
| 284 | Rani Temple Boundary Wall |
| 285 | Security Kiosk (Rani Temple) |
| 286 | First Floor |
| 287 | Yatri Nivas |
| 288 | Terrace Floor |
| 289 | Yatri Nivas |
| 290 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 291 | Repair Of Existing Boundary Wall (Indralath Temple) |
| 292 | Supplying, Fitting and Fixing M.S Gate of approved designs made out of M S Flat, Square bars/Round bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading, stacking, of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 293 | Ground Floor |
| 294 | Yatri Nivas |
| 295 | Boundary Wall(Main Temple) |
| 296 | Rani Temple Boundary Wall |
| 297 | Security Kiosk (Rani Temple) |
| 298 | First Floor |
| 299 | Yatri Nivas |
| 300 | Terrace Floor |
| 301 | Yatri Nivas |
| 302 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. |
| 303 | Ground Floor |
| 304 | Yatri Nivas |
| 305 | Security Kiosk (Rani Temple) |
| 306 | First Floor |
| 307 | Yatri Nivas |
| 308 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m. |
| 309 | Yatri Nivas |
| 310 | Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. |
| 311 | Yatri Nivas |
| 312 | Providing average 40mm thick grading Concrete with (1:2:4) using 12mm & down graded size black hard granite chips mixing of water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. All complete in all respect as per direction of the Engineer -in-charge. |
| 313 | Security Kiosk (Rani Temple) |
| 314 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision). |
| 315 | Heritage Road |
| 316 | Paved Road(Rani Temple) |
| 317 | Paved Road(Indralath Temple) |
| 318 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (4th Revision). |
| 319 | Heritage Road |
| 320 | Paved Road(Rani Temple) |
| 321 | Paved Road(Indralath) |
| 322 | Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make,design,colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect confirming to IRC SP63:2018 |
| 323 | Heritage Road |
| 324 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make,design,colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect confirming to IRC SP63:2018 |
| 325 | Paved Road (Rani Temple) |
| 326 | Paved Road (IndralathTemple) |
| 327 | Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984 |
| 328 | Heritage Road |
| 329 | Paved Road(Rani Temple) |
| 330 | Paved Road (IndralathTemple) |
| 331 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Covers on drains of footpath of various sizes, of M-25 grade cement concrete, including cost of centering, shuttering, reinforcement of specified dia TMT bars of Fe 500 grade, neat cement punning on finished surface, properly encased on all edges and providing 2 Nos. 12 mm dia bar for hooks, including cost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
| 332 | Drainage |
| 333 | Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres |
| 334 | Heritage Road |
| 335 | Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. |
| 336 | Heritage Road |
| 337 | Providing and laying semi dense bituminous concrete with batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder of 60/70 penetration grade of bitumen, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheelede, vibratory and tandem rollers to achieve the desired compaction as per Clause 508 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 338 | Heritage Road |
| 339 | Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means. |
| 340 | Heritage Road |
| 341 | Providing and laying of tack coat with bitumen emulsion on prepared surface of granular Base including cleaning of road surface and spraying at the rate of 0.20 kg/sqm by mechanical means. |
| 342 | Heritage Road |
| 343 | Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour,T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. |
| 344 | Heritage Road |
| 345 | Providing and fixing Ornamental khandolite Stone work, plain in copings, cornices, string courses and plinth courses, of required thickness in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, T & P etc. All complete as per drawing and direction of the Engineer -in-charge. |
| 346 | Entrance Gateway |
| 347 | SUPERSTRUCTURE UPTO 4.2 MTR |
| 348 | ABOVE 4.2 MTR |
| 349 | Providing & fixing of khondalite Sclupture of height 600 mm and width 500 mm as per the architectural design and drawing etc all complete as per the direction of Engineer-in-charge. |
| 350 | Entrance Gateway |
| 351 | Providing & fixing of khondalite Sclupture of height 1000 mm and width 900 mm as per the architectural design and drawing etc all complete as per the direction of Engineer-in-charge. |
| 352 | Entrance Gateway |
| 353 | Providing and fixing stainless steel acrylic LED letter (Logo) As per the architectural design and drawing etc all complete as per the direction of Engineer-in-charge. |
| 354 | Entrance Gateway |
| 355 | Providing and Fixing Unistone or equivalent premium Da Vinci Cultured Stone in Khondalite natural stone pattern & shade & approved size in 15 mm thickness, ± 2mm accepted tolerance along with corner pieces at all corners of building in sizes, as available with manufacturer. The pattern should replicate natural stone appearance using differential textured mould technique and pigmentation should be done by infusion methodology to infuse surface with authentic natural tones. Dual or triple tone shading cultured stone should be casted using homogenous base pigmentation with top layer differential shade penetration technique to simulate ultra‐ realistic natural stones. The pattern should have variation in shade and have hints of rust, rust browns, copper, umbers and deep yellows to simulate actual stone. The material should be casted in controlled production environment concrete mix design with high pressure vibratory methodology, 43 – grade OPC white Cement, reinforced with Alkali Resistant Glass fibre1.5 %, The glass fibre shall be alkali resistant (AR) with minimum Zirconium Dioxide (ZrO2) content of 16% and shall be manufactured by approved manufacturer as per specification of approved make i.e., by M/s N.E.G Japan or Owens Corning. The stone cladding cultured stone should be pigmented with synthetic mineral iron oxide non fading weatherproof, UV resistant pigments of M/s Phenochem, Lanxess or equivalent and it. The product should be applied on rough plastered substrate (1:3) Cement and Coarse Sand and should be applied with Unistone ‘Ultimate’ or equivalent Exterior Grade high strength cementitious polymer modified tile adhesive having tensile adhesion strength ≥ 2.5 N / mm2 as per EN ‐1348. The product should be applied with adequate grooves and all horizontal and vertical grooves to be filled and pointed with a mix of fine sand and cement in ratio (3 Fine sand: 1 Cement). All work should be carried out as per manufacturer’s and as per direction of Engineer in charge |
| 356 | Rani Temple Boundary Wall |
| 357 | Providing and fixing Plain Khondalite Stone Works, clading or wall of required thickness in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, T & P etc. All complete as per drawing and direction of the Engineer -in-charge. |
| 358 | Security Kiosk (Rani Temple) |
| 359 | TEXTURED PAINT :- Providing Two coat of Textured paint of approved make, quality and shade over the wall surface of the building over (Two or more coats ) of primer of approved make including cost of material, brushes, all labour, loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) |
| 360 | Heritage Road |
| 361 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water |
| 362 | Rani Temple Landscape |
| 363 | Indralath Temple Landscape |
| 364 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete |
| 365 | Rani Temple Landscape |
| 366 | Indralath Temple Landscape |
| 367 | Supplying and stacking sludge at site including royalty and carriage upto 5 km complete |
| 368 | Rani Temple Landscape |
| 369 | Indralath Temple Landscape |
| 370 | Rough dressing the trenched ground including breaking clods. |
| 371 | Rani Temple Landscape |
| 372 | Indralath Temple Landscape |
| 373 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
| 374 | Rani Temple Landscape |
| 375 | Indralath Temple Landscape |
| 376 | Fine dressing of the ground. |
| 377 | Rani Temple Landscape |
| 378 | Indralath Temple Landscape |
| 379 | Supplying and stacking at site dump manure from approved source, including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment). |
| 380 | (i)Screened through sieve of I.S designation 20mm |
| 381 | Rani Temple Landscape |
| 382 | Indralath Temple Landscape |
| 383 | (ii)Screened through sieve of I.S designation 16mm |
| 384 | Rani Temple Landscape |
| 385 | Indralath Temple Landscape |
| 386 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 387 | Rani Temple Landscape |
| 388 | Indralath Temple Landscape |
| 389 | Grassing with selection carpet lawn grass including watering and maintainance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for moving including supplying good earth |
| 390 | Carpet lawn Grass |
| 391 | Rani Temple Landscape |
| 392 | Indralath Temple Landscape |
| 393 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge. |
| 394 | Rani Temple Landscape |
| 395 | Indralath Temple Landscape |
| 396 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : |
| 397 | Holes 90 cm dia, and 90 cm deep |
| 398 | Heritage Road |
| 399 | Rani Temple Landscape |
| 400 | Indralath Temple Landscape |
| 401 | Holes 45 cm dia, and 45 cm deep |
| 402 | Rani Temple Landscape |
| 403 | Indralath Temple Landscape |
| 404 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) |
| 405 | Trees Plant |
| 406 | Heritage Road |
| 407 | Rani Temple Landscape |
| 408 | Indralath Temple Landscape |
| 409 | plantation per Shrub |
| 410 | Rani Temple Landscape |
| 411 | Indralath Temple Landscape |
| 412 | Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. |
| 413 | Rani Temple Landscape |
| 414 | Neem of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 415 | Rani Temple Landscape |
| 416 | Indralath Temple Landscape |
| 417 | Karanja of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 418 | Rani Temple Landscape |
| 419 | Indralath Temple Landscape |
| 420 | Akashmalli of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 421 | Rani Temple Landscape |
| 422 | Indralath Temple Landscape |
| 423 | Amla of height 3m - 4m (3 to 4 years old) well developed with thick stem |
| 424 | Rani Temple Landscape |
| 425 | Indralath Temple Landscape |
| 426 | Mango of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 427 | Rani Temple Landscape |
| 428 | Indralath Temple Landscape |
| 429 | Kochila of height 4m -5m (2 to 3 years old) well developed with thick stem |
| 430 | Rani Temple Landscape |
| 431 | Indralath Temple Landscape |
| 432 | Champa (white,red, pink) of height 3m-4m (2 to 3 years old) well developed with thick stem |
| 433 | Rani Temple Landscape |
| 434 | Indralath Temple Landscape |
| 435 | Baul of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 436 | Rani Temple Landscape |
| 437 | Indralath Temple Landscape |
| 438 | Ashoka of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 439 | Rani Temple Landscape |
| 440 | Indralath Temple Landscape |
| 441 | Arjun of height 3m-4m (2 to 3 years old) well developed with thick stem |
| 442 | Rani Temple Landscape |
| 443 | Indralath Temple Landscape |
| 444 | Bahunia purpurea (kanchan) of height 4m-5m (3 to 4 years old) well developed with thick stem |
| 445 | Rani Temple Landscape |
| 446 | Indralath Temple Landscape |
| 447 | Peepal/ Banyan Tree of height 4m -5m (3 to 4 years old) well developed with thick stem |
| 448 | Rani Temple Landscape |
| 449 | Indralath Temple Landscape |
| 450 | Plantzoin Royal poinciana Gulmohar Delonix regia Krushnachuda Live Plant (Krushna chuda tree) |
| 451 | Heritage Road |
| 452 | Supplying and planting below mentioned best quality container- grown healthy shrubs/plants of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. |
| 453 | Rani Temple Landscape |
| 454 | Aparajita (black & height) of height up to 1 mtr (1 to 2 yrs) old |
| 455 | Rani Temple Landscape |
| 456 | Indralath Temple Landscape |
| 457 | aswagandha of height up to 2 mtr (1 to 2 yrs) old |
| 458 | Rani Temple Landscape |
| 459 | Indralath Temple Landscape |
| 460 | dhannantari of height up to 2 mtr (1 to 2 yrs old) |
| 461 | Rani Temple Landscape |
| 462 | Indralath Temple Landscape |
| 463 | ganga siuli of height up to 2 mtr (1 to 2 yrs old) |
| 464 | Rani Temple Landscape |
| 465 | Indralath Temple Landscape |
| 466 | kamini of height up to 1 mtr (1 to 2 yrs old) |
| 467 | Rani Temple Landscape |
| 468 | Indralath Temple Landscape |
| 469 | rukunaa hatapochaa of height up to 1 mtr (1 to 2 yrs old) |
| 470 | Rani Temple Landscape |
| 471 | Indralath Temple Landscape |
| 472 | sadabihari (red & white) of height up to 1 mtr (1 to 2 yrs old) |
| 473 | Rani Temple Landscape |
| 474 | Indralath Temple Landscape |
| 475 | Jasmine of height up to 1 mtr (1 to 2 yrs old) |
| 476 | Rani Temple Landscape |
| 477 | Indralath Temple Landscape |
| 478 | FERTILIZERS |
| 479 | Supply and applying of chemical fertilizer before or after as per requirement, as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. |
| 480 | Rani Temple Landscape |
| 481 | Urea / Ammonium Sulphate (30gm/M²) |
| 482 | Rani Temple Landscape |
| 483 | Indralath Temple Landscape |
| 484 | Bone Meal (150gm/M²) |
| 485 | Rani Temple Landscape |
| 486 | Indralath Temple Landscape |
| 487 | Potassium Sulphate or Murate of Potash (20gm/M²) |
| 488 | Rani Temple Landscape |
| 489 | Indralath Temple Landscape |
| 490 | Provision of insecticides (10ml IN 10 ltr/M²) |
| 491 | Rani Temple Landscape |
| 492 | Indralath Temple Landscape |
| 493 | Supplying and fixing of 120 Litre of different colour Plastic Wheel Dustbin (wet & dry) , WB120L, Dimension: 92x48x55 cm.etc including cost of all labour,material loading,unloading,taxes etc.all complete as per the direction of E-I-C. |
| 494 | Heritage Road |
| 495 | Rani Temple |
| 496 | IndralathTemple |
| 497 | Supplying and fixing of 80 Litre of Silver Stainless Steel Open Top Dustbin 14x28 Inch.etc including cost of all labour,material loading,unloading,taxes etc.all complete as per the direction of E-I-C. |
| 498 | Heritage Road |
| 499 | Rani Temple |
| 500 | IndralathTemple |
| 501 | Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge |
| 502 | Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm |
| 503 | Heritage Road |
| 504 | Rani Temple |
| 505 | IndralathTemple |
| 506 | Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm |
| 507 | Heritage Road |
| 508 | Rani Temple |
| 509 | IndralathTemple |
| 510 | Location based signage: The signage structure is a combination of wrought/cast iron pipe structure with sandstone base and iron brackets. Stainless Steel Panel flags with symbol and text digitally H1625-RS printed on micro prismatic retro reflective boards conforming to type XI DG3 (diamond grade) 4000 series. Text language: Odia and English. Text height: Odia 55-60 mm; English 55-60 mm as per drawings & direction of Engineer in charge. |
| 511 | Rani Temple |
| 512 | IndralathTemple |
| 513 | Wayfinding signage: Mild steel panels (with/without wrought iron frame) screwed directly on wall. Text printed digitally H1625 -RS printed on micro prismatic retro reflective boards conforming to type XI DG3 (diamond grade) 4000 series. Text language: Odia and English. Text height: Odia 40-45 mm English 40 - 45 mm Century 30 -35 mm. Icon height: 155 -175 mm as per drawings & direction of Engineer in charge. |
| 514 | Rani Temple |
| 515 | IndralathTemple |
| 516 | Story signage: DG3 digital printing series (super high efficiency reflective sheeting) with alphabets/ numerical/ pictorials digitally printed and laminated using 1170c laminate in matt finish. The base corresponds to a specific kind of pedestal i.e. Kani Pista, with three mouldings with 4:5:6 proportion. Concrete structure with text etched and painted on top. Sandstone cladding at the base text. Language: Odia and English. Text height: Heading - 10 mm Supporting text - 8 mm as per drawings & direction of engineer in charge. |
| 517 | Rani Temple |
| 518 | IndralathTemple |
| 519 | Cultural marker: Providing and fixing 600 x 600 x 1800 mm (LXWXH) culture marker made of stone block with CNC etching and carving designs fixed over MS support structure made up of 150 X150 mm MS pipes with weather proof paint and primer fixed on the sub structure inclusive of all necessary hardwares to make structure stable as per site with complete base work and foundation and research, scriptwriting, proofreading and copywriting of all the content in 3 language (Oriya , Hindi & Englidh )with designing the and developing the infographics of all the graphical representation, illustration, theoraticaland textual content placement of provided content along with development of print ready files for the fabrication and production as/design/drawing with complete work as per site engineer incharge. |
| 520 | Rani Temple |
| 521 | IndralathTemple |
| 522 | Providing and fixing 2000 x 2000 x 3000 mm (LXWXH) culture marker made of Khandolite stone block with CNC etching and carving designs fixed over RCC structure with fixed on the sub structure inclusive of all necessary hardwares to make structure stable as per site with complete base work and foundation and research, scriptwriting, proofreading and copywriting of all the content in 3 language (Oriya , Hindi & Englidh )with designing the and developing the infographics of all the graphical representation, illustration, theoraticaland textual content placement of provided content along with development of print ready files for the fabrication and production as/design/drawing with complete work as per site engineer incharge. |
| 523 | Rani Temple |
| 524 | IndralathTemple |
| 525 | Supplying and fixing of Ornamental Khandolite benches of approve size and Specification complete set etc. including cost of all labour,material,loading and unloading,conveyance,T&P etc.all complete as per the direction of E-I-C. |
| 526 | Rani Temple |
| 527 | IndralathTemple |
| 528 | Sub-Head I (modular Wiring Items) |
| 529 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Each lightpoint should have provision for ceiling rose and angle holder point.NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the lighting, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. |
| 530 | GROUP-A |
| 531 | GROUP-B |
| 532 | GROUP-C |
| 533 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 534 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 535 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 536 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 537 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 538 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 539 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit (2X6+1X4) |
| 540 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) |
| 541 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit . (4X10+2X6) |
| 542 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 543 | Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 544 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 545 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 546 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 547 | Sub-Head II (Light fitting Fixture & Fan) |
| 548 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 549 | Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow6000 CFM @ 15mm MMWG static pressure |
| 550 | Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness) |
| 551 | 24 gauge (0.63 mm thickness) |
| 552 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 553 | Supply, Installation, Testing and Commissioning of bird screen made by stain less steel for fans |
| 554 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 555 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 556 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 557 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 558 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 559 | SITC of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 560 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 561 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 562 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator).Warranty on DB is 3 years (UPS DB 2 NOS EACH FLOOR,CONF) |
| 563 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LDB .) |
| 564 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years (FOR PDB ,AC DB,.) |
| 565 | Supplying and fixing 6- 32 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years . |
| 566 | Supplying and fixing 32 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 567 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 568 | Supplying and fixing 40Amps 4P 415 volts, MCB, C series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 569 | Supplying and fixing 40 Amps rating, RCCB 30mA 4P . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 570 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 571 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 572 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 573 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 574 | CABLING AND END TERMINATION MAIN AREA |
| 575 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 576 | 4core x 16 sq mm |
| 577 | 3.5core x 150 sq mm (BHAKTA NIBAS POWER) |
| 578 | 3.5core x300 sq mm (MAIN CABLE,DG CABLE) |
| 579 | LAYING OF CABLE |
| 580 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 581 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 582 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 583 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 584 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 585 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 586 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 587 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 588 | Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 589 | Supplying and making end termination with 3.5 core x150 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 590 | Supplying and making end termination with 3.5 core x300 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 591 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 592 | 50 mm dia |
| 593 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 594 | Supplying,laying of 3cx2.5 sq.mm AL armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 595 | Supplying,laying of 3cx6 sq.mm AL. armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 596 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 597 | 50 mm dia |
| 598 | MAIN CONTROL PANEL NEAR BHAKTA NIBAS |
| 599 | S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 1+2 SPD 50 kA/Pole with 600A HRC backup fuse shall be installed in the incomer. 80X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory. All the feeders shall have ON/OFF/TRIP indication. |
| 600 | In commer-1-01 number of 630A 4P Icu=100%Ics,36Ka LSIG MCCB with microprocessor release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 601 | In commer-2- 01 number of 250A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 602 | Changeover- 01 no of 250A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB) |
| 603 | Busbar-1&2 04 numbers of 800Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 604 | Out going- 02 numbers of 200 Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 605 | Out going- 02 numbers of 125Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 606 | Out going- 01 numbers of 160Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 607 | Out going- 6 numbers of 100-63Amps 4P MCCB.Icu=100%Ics,16Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 608 | Out going- 1 number of 100Amps 4P MCCB Motorized .Icu=100%Ics,25Ka ,LSING ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula for Solar on grid integrate . |
| 609 | Outgoing- 4 nos. 32A 4P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 |
| 610 | Outgoing- 8 nos. 32A 2P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200(Among it 2 nos with space for KWH Meter for shop) |
| 611 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 612 | (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(iii) All the MCCB outgoing feeders shall have digital ammeter with CT of suitable class 1 rating.(Make-Legrand/Siemens/Schneider/ABB) iv) |
| 613 | MAIN CONTROL PANEL BHAKTA NIBAS |
| 614 | S/I/T&Commissioning of LT INDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication. |
| 615 | In commer-1-01 number of 250A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 616 | In commer-2-01 number of 200A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 617 | Changeover- 01 no of 200A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB) |
| 618 | Busbar-1&2 04 numbers of 300Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 619 | Out going- 6 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 620 | Out going- 4 numbers of 6-32A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 621 | Out going- 4 numbers of 63A 4P MCCB16KA TMR based, Ics=100%Icu ( Make-LEGRAND-DPX3/ Siemens-3VA/ Schneider- CVS/ABB FORMULA) |
| 622 | Out going- 8 numbers of 40A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 623 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 624 | (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication iii) 3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. (Make of SPD-Legrand/Siemens/Schneider/ABB),Make of MCB-LEGRAND-DX3 / Siemens-Betaguard Model/ Schneider-Acti-9 /ABB SB200 |
| 625 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 626 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 627 | Busbar- 04 numbers of 200Amps 25*5mm copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. |
| 628 | Supplying,fixing of 8 module under- FLOOR outlet box IP20, size not less than 308mmx308mm as required as per direction of Engg.-in-Charge.MAKE- Profab/OBO/Neidax/Legrand |
| 629 | Supply ,installation ,testing & commissioning of 10 KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 42AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for IPC building |
| 630 | EARTHING |
| 631 | Supplying,installation,testing & commissioning Of Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per direction of Engg. in charge. |
| 632 | Supplying & laying of 6 swg GI WIRE at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge. |
| 633 | Supplying & laying of 25mm x 5 mm GI strip at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge. |
| 634 | LIGHT SYSTEM EXTERNAL |
| 635 | Supply, installation, testing and commissioning of LED Design based BIS approved LED Street Light with system power of 90W, CCT in 5700K as per ANSI) ,CRI>70, SDCM<3 , LEDs used should have a life of 50,000 burning hrs. & Lumen maintenance as per L70. The Luminaire System lumens should be >=11,700 Lumens @5700K. The fixture housing must be Made of ADC 12 PDC Aluminium housing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have a Ingress protection of IP66 and Impact Resistance of IK08. The light engine should use Metal Core PCB with high grade aluminium (AL5052) and should have a thermal conductivity of >2W/mK. The fixture should have an UV stabilized Injection moulded special PC lens optics(Glass not allowed) ensuring low glare & best in class uniformity. The light and the driver compartment should be thermally isolated by a natural airgap. Luminaire housing and optical compartment both should carry OEM's logo embossed / engraved (no stickering is allowed). The luminaire must have Integral encapsulated high efficiency electronic thermally isolated driver having a Aluminium extrusion construction with rated voltage of 100-300V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of min 6KV and upgraded with integrated IP67 protected SPD of 20KV/10KA surge protection with all necessary safety protection like mis-wiring, Over voltage, Short circuit, Reverse Polarity protection. . The compartment should be bottom openable for ease of maintenance at site. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. Following documents to be submitted after award of contract: Luminaire and Driver TDS, Photometry report, Type test certificate, IP, IK, Vibration and salt spray test certificates from NABL accredited Laboratory, LM80 from LED OEM., CE Certification, ROHS compliant, BIS Certificate for Luminaires & Drivers. The warranty on light fixture shall be 5 years. (Make: PHILIPS/WIPRO/BAJAJ/Crompton/PANASONIC/LT/HAVELLS) |
| 636 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 637 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 638 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 639 | Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.The price inclussive of 3 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-300 + KL-5444 Luminaries / LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj). |
| 640 | Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.Make-Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj/K-Lite.The price inclussive of of 4 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-400 + KL-5444 Luminaries/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj). |
| 641 | Supplying, Erection, Fixing, connection & testing of 50W LED Heritage GATE Light, Dimension of light must be Ø400mm dia and 800mm height, IP 66, IK07, amb. temp -10 to 45 degree celcious, CT 3000-5700K,,50000 HRS, CRI 70, 120 Lm/W system efficacy,driver efficiency >/ 85%,dia case aliminium housing,Clear Acrylic diffuser of Make-K-LITE Model No - 25444/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj as approved maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 642 | Supply, Installation, Testing & Commissioning of of IP65 (16)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-K -lite Bollard KL-25582/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 643 | Supply, Installation, testing & commissioning of 7 meter long aesthetically designed Single Arm decorative lighting pole with 1.2 mtr height Cast Iron base, cast aluminium ring on the middle portion and Trishul on the top. Pole shall be made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating of Antique Copper finish. Bottom dia of the pole will be Ø114.3mm or higher & top decorative arm portion having dia of Ø60 mm or higher and having base Plate of size Ø280 x16mm thick with provision for founation bolt. Pole is Compatible for Ø70mm size for cable entry & exist. Junction Box service door is made up cast aluminium and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 32A 4pole terminal connector for loop-in loo-out arrangement with all materials & labour as required as per the direction of Engineer-in- Charge. (Make: K -lite Pelican Mini Orna Trishul Carolina Pole KP-12037-700-SA or, similar to Jaquar/Bajaj/Reytek/Homdec). |
| 644 | Supply, Installation, testing & commissioning of 7 meter long aesthetically designed Double Arm decorative lighting pole with 1.2 mtr height Cast Iron base, cast aluminium ring on the middle portion and Trishul on the top. Pole shall be made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating of Antique Copper finish. Bottom dia of the pole will be Ø114.3mm & top decorative arm portion having dia of Ø60 mm and having base Plate of size Ø280 x16mm thick with provision for founation bolt. Pole is Compatible for Ø70mm size for cable entry & exist. Junction Box service door is made up cast aluminium and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 32A 4pole terminal connector for loop-in loo-out arrangement with all materials & labour as required as per the direction of Engineer-in- Charge. (Make: K -lite Pelican Mini Orna Trishul Carolina Pole KP-12037-700-DA or, similar to Jaquar/Bajaj/Reytek/Homdec). |
| 645 | Supply, Installation, testing & commissioning of 100W LED Pendent light having Extruded aluminium with Spun Aluminium Top housing and coated with zinc rich primer & pure polyester powder coating of Antique Copper Finish, UV Stabilized Translucent Acrylic diffuser and suitable for mounting on 60 mm OD pipe. CCT-3000K, CRI-≥70, IP-65, IK-07, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 6KV, Efficiency : >85%, Optical Distribution :120degree. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Pelican KL-26799 or, similar to Jaquar/Bajaj/Reytek/Homdec). |
| 646 | Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with street light on that foundation(Details Drawing of the foundation attached). The work shall be excuted as per the direction of EIC.The structural calculation, wind load calculation and civil foundation shall be duly approved by the competent authority from civil wing (SE/CCE/Competant authority)before execution of the work. |
| 647 | Supply , Installation, testing & commissioning of 12W LED step light of Dimension : 255mm x 87mm x 76mm and having die-cast aluminium housing and coated with zinc rich primer & pure polyester powder coating of Jet Black Finish, UV Stabilized Satin Acrylic diffuser. CCT-3000K, CRI-≥70, IP-65, IK-09, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 6KV, Efficiency : >85%, Optical Distribution :120degree. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Sudo KL-22525 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec). |
| 648 | Supply, Installation, testing & commissioning of 9W LED Inground Bourial light of Dimension: Ø116X153 having die-cast aluminium housing and with SS Top ring , UV Stabilized Toughened Glass diffuser. CCT-3000K, CRI-≥70, IP-67, IK-08, SDCM≤ 3, BA-25deg, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 4KV, Efficiency : >85%, Optical Distribution :Asymmetrical. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite In-Ground Bourial 21790 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec). |
| 649 | Supply , Installation, testing & commissioning of 60W LED Focus Light having die-cast aluminium housing and coated with zinc rich primer & pure polyester powder coating of Jet Black Finish, UV Stabilized Clear toughened glass diffuser. CCT-3000K, CRI-≥70, IP-65, IK-06, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 4 KV, Efficiency : >80%, Optical Distribution :45 degree beam angle. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Iyra KL-22561 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec). |
| 650 | Supply , Installation, testing & commissioning of 36W LED Linear wall washer Light of dimenssion must be 1000X85X38 having 6063 Aluminium Alloy housing with UV Stabilized Clear toughened glass diffuser. CCT-3000K, CRI-≥70, IP-66, IK-05, Lumen maintainance >50,000 burning hours as per L70 B10, Optical Distribution :12 degree beam angle. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite KL-23068 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec). |
| 651 | Supply , Installation, testing & commissioning of 9W/MTR LED Neon Flex having Copper Coated Strip body, UV Stabilized Silicone Moulded diffuser. CCT-3000K, CRI-≥80, IP-65, SDCM≤ 3, Lumen maintainance >50,000 burning hours as per L70 B10, 24V DC, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 6KV, Efficiency : >85%, Optical Distribution :120degree. Flex to be provided with required IP67 driver and SS Chanel for installation. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Niva KL-23224 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec). |
| 652 | Supply , Installation, testing & commissioning of IP67 150W 24V DC Driver. |
| 653 | SITC of IP 68 T connector |
| 654 | CABLING |
| 655 | Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 656 | 4core x 16 sq mm (OFP TO IND. TIMER PANEL) |
| 657 | 4 core x 4 sq mm (for small power/LIGHT TO POLE) |
| 658 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 659 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 660 | Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 661 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make-POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster |
| 662 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 663 | 50 mm dia |
| 664 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 665 | Solar light |
| 666 | Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonic/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 667 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 4 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 668 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 669 | Installation of 60W AIO LED solar street light on 8 mtr octagonal pole. |
| 670 | ELV-CCTV ,PA SYSTEM |
| 671 | SITC of 5MP IP Bullet/Dome Camera with inbuilt microphone, equipped with 1/2.7\\" Progressive Scan CMOS image sensor and 3.6/2.8(for dome) mm fixed lens, supporting a resolution of 2592 × 1944 or higher. The camera shall provide IR illumination up to 30 meters and an approximate field of view of 79° (H)/97(for dome), 56°/70(for dome) (V), and 106°/128( for dome) (Diagonal). Minimum illumination shall be 0.003 lux @ F1.6 (AGC ON) with support for WDR (120 dB). The camera shall support video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multiple streaming capability including main stream up to 5MP @ 30 fps, sub-stream up to 1080p @ 30 fps, and additional third stream. The camera shall support intelligent analytics such as human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. The device shall support motion detection with multiple configurable zones and network protocols including TCP/IP, HTTP, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 GB( for dome), privacy masking, ICR auto day/night switching, and support 12V DC or PoE power supply. The housing shall be metal body with IP67 weatherproof protection, suitable for outdoor installation. The product shall comply with NDAA requirements and shall be certified with STQC, BIS, CE, FCC and RoHS. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 672 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 673 | Supply , Installation, testing , commissioning of 32 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS). Make-Honeywell value series/ Pelco/ Axis/ Bosch |
| 674 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 675 | SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer |
| 676 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 677 | SITC of outdoor type double jacketed 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 678 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 679 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 680 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 681 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax/ Legrand/ Panduit |
| 682 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit(1 mtr length) |
| 683 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit (2 mtr length) |
| 684 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco/ Digisol/ Netgear |
| 685 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax/ Legrand/ Panduit |
| 686 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax/ Legrand/ Panduit |
| 687 | SITC of 9U/500D outdoor type IP 55 Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make: Valrack/ Rittal/ Legrand |
| 688 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 689 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear |
| 690 | PA SYSTEM |
| 691 | Supply of 20 Watt outdoor Horn Speaker, IP65, Frequency Response : 150 Hz – 15 kHz, 4 INCH DRIVER, peak power handling capacity 80W, Should have Passive 350 Hz high-pass filter built-in, SPL : 133 dB peak @ 1.4 kHz, IP-65 rating per IEC529, Coverage Pattern: 60° horizontal by 80° vertical , Maximum SPL (1m): 109dB peak, 8 ohm Impedence, Transformer Taps: 70V/100V: 20W, 100V: 30 w.MAKE:Bose/EV/Audac(HS121)/Sonodyne |
| 692 | Supplying, installing, testing and commissioning of quad channel Power amplifier of continous power 4x 240 W @8 ohm and 100V, frequency response- 50Hz-20 kHz , class D amplifier.The amplifier should be clean reliable audio for public address amplification and music.Line input less than 1 volt, unbalanced& line output less than 1 volt unbalanced.Make-Bose/Audac(PMQ240)/EV/Sonodyne |
| 693 | Supply of 30 W weather proof rock speaker with LMT, IP65 , Transformer Taps: 70V/100V: 20W, 100V: 30 w Make-Sonodyne (RS 650)/Bose/EV/Audac |
| 694 | Supply of 10-Channel Mixing Console: Max. 4 Mic / 10 Line Inputs (2 mono + 1 stereo) / 4 GROUP Buses + 1 Stereo Bus / 4 AUX (incl. FX),16-Channel Mixing Console mic preamps with an inverted Darlington circuit,1-Knob compressors,High-grade effects: SPX with 24 programs,24-bit/192kHz 2in/2out USB Audio functions,Works with the iPad (2 or later) through the Apple iPad Camera Connection Kit / Lightning to USB Camera Adapter,Includes Cubase AI DAW software download version,PAD switch on mono inputs,+48V phantom power,XLR balanced outputs with provision for bluetooth.Make-Yamaha/Soundcraft/Studiomaster |
| 695 | SITC of 17U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make: Valrack/ Rittal/ Legrand |
| 696 | Speaker Cable Armoured 2 core 2.5 sqmm PVC Sheathed etc complete as required. |
| 697 | Laying of cable (Digging , laying and refilling with sand and Bricks) |
| 698 | Installation of all equipment, testing and commissioning of the system |
| 699 | FIRE SAFETY EQUIPEMENT |
| 700 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog/Kalpex .4.5 kg capacity |
| 701 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog/Kalpex .6 kg capacity |
| 702 | SIGNAGES: SITC of flexyl Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages Make-Bajaj/Prolite |
| 703 | Supply, installation, testing and commissioning of double sided visible LED illuminated Exit Indication Sign(300 mmx 150 mm, letter height minimum 150 mm) complete with directional arrow legend, rechargeable maintenance-free battery backup capable of providing continuous illumination for not less than 90 minutes upon mains failure, automatic charger circuit, fire-retardant ABS housing, polycarbonate diffuser, minimum letter height 150 mm, suitable for 230V AC supply, wall/ceiling mounting arrangement, complete with all accessories, wiring connections, testing and commissioning as required. The equipment shall comply with applicable requirements of NFPA 101, NFPA 70 and UL 924 standards.The Exit Indication Sign shall be a self-contained, LED-illuminated unit with integrated rechargeable battery backup, directional arrow (left, right, or straight), and automatic changeover circuitry. The sign shall operate in maintained mode (continuously illuminated) or non-maintained mode as specified, and shall automatically switch to battery power upon mains failure. The pictogram shall comply with ISO 7010 (E001 / E002 green running-man symbol) as mandated by NBC 2016 and IBC 2021. Make-Bajaj/Prolite |
| 704 | LIGHTENING PROTECTION SYSTEM--- Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 705 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 706 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 707 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 708 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 709 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 710 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/ABB |
| 711 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 712 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 713 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 714 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 715 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 716 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 717 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 718 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 719 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 720 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 721 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB |
| 722 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 723 | PH WORKS |
| 724 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge |
| 725 | 20mm dia PVC ASTM pipe (sch-80) |
| 726 | Ground Floor |
| 727 | First Floor |
| 728 | 25mm dia PVC ASTM pipe (sch-80) |
| 729 | Ground Floor |
| 730 | First Floor |
| 731 | 32mm dia PVC ASTM pipe (sch-80) |
| 732 | 40mm dia PVC ASTM pipe (sch-80) |
| 733 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 734 | 15mm dia CP angle stop cock(FLR-ACR-5053N) |
| 735 | 15mm dia CP two way bib cock(FLR-CHR-5041N) |
| 736 | 15mm dia CP Bib cock (Con-CHR-047KN Jaquar make) |
| 737 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 738 | 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
| 739 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 740 | 25mm dia brass full way valve (Shakti make) |
| 741 | 32mm dia brass full way valve (Shakti make) |
| 742 | 40mm dia brass full way valve (Shakti make) |
| 743 | 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
| 744 | 15mm CP Extension piece |
| 745 | 125mm CP grating |
| 746 | 15mm size C.P. flange |
| 747 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge |
| 748 | 2000 liters capacity PVC water storage tank roof of 1st floor |
| 749 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 750 | Ground Floor |
| 751 | First Floor |
| 752 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge |
| 753 | Ground Floor |
| 754 | First Floor |
| 755 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
| 756 | Ground Floor |
| 757 | First Floor |
| 758 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 759 | 110mm U-PVC SWR Pipe (Supreme /Ashirvad) |
| 760 | 110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
| 761 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 762 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 763 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 764 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 765 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 766 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 767 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 768 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 769 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 770 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 771 | 580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 772 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 773 | 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 774 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal |
| 775 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 776 | European water closet with 'p' trap plain(Hindware/Parryware/Neycer make) |
| 777 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge |
| 778 | Under Counter basin(560x450)Hindware-No.10095 |
| 779 | 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) |
| 780 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink |
| 781 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 782 | 25mmx600mm long CP towel rail |
| 783 | Towel ring |
| 784 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. |
| 785 | 600mmx125mm plate glass shelf with CP/NP guard rails. |
| 786 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. |
| 787 | 600mmx450mm size B.E mirror (swivelled type) |
| 788 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 789 | CP soap holder |
| 790 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. |
| 791 | ½” x 5” CP Shower (Plaza Deluxe Make) |
| 792 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 793 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 794 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge |
| 795 | Inside size 76cmx76cmx46cm with 18” dia RCC MH cover |
| 796 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge |
| 797 | Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. |
| 798 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 799 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 800 | Ground Floor |
| 801 | First Floor |
| 802 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 30cmx30cm special printed series to be pre-approved by the Engineer-in-charge ) |
| 803 | Kajaria/Somany/Johnson tile 30cmx30cm |
| 804 | Ground Floor |
| 805 | First Floor |
| 806 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 807 | Ground Floor |
| 808 | First Floor |
| 809 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 45cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge ) |
| 810 | Kajaria/Somany/Johnson tile 45cmx30cm |
| 811 | Ground Floor |
| 812 | First Floor |
| 813 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 814 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 815 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liter's along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge |
| 816 | Aqua guard pure Chill 80 PSS UV |
| 817 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge |
| 818 | 100mm dia P.V.C. pipe |
| 819 | 150mm dia P.V.C. pipe |
| 820 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. |
| 821 | MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) |
| 822 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 823 | 50 Users septic tank of size |
| 824 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 825 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 826 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 827 | Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete.5.90 x 3.30 x 0.225 |
| 828 | Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site. 4.75 x 2.15 x 0.15 = |
| 829 | Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. |
| 830 | Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor. |
| 831 | RCC floor, roof slab chhaja up to 4.430 m height |
| 832 | Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site. |
| 833 | Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site. |
| 834 | Supplying all materials labour T&P and providing 12mm thick C.P (1:6) including watering curing and conveyance of all materials to site.(out side) |
| 835 | Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site. Same as plaster |
| 836 | Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. |
| 837 | Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. |
| 838 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. |
| 839 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories |
| 840 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 841 | Drilling of 200mm dia bore |
| 842 | 00 mtr to 30mtr |
| 843 | 30 mtr to 45mtr |
| 844 | Drilling of 150mm dia bore |
| 845 | 45 mtr to 180.00mtr |
| 846 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 847 | Lowering of 200mm dia P.V.C casing pipes |
| 848 | 00 mtr to 30 mtrs |
| 849 | 30 mtr to 45mtr |
| 850 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. |
| 851 | 200mm dia PVC (sch-80) pipe |
| 852 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 853 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 854 | By DTH Rig |
| 855 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: |
| 856 | Rocky terrain with boulder formation for 300m depth |
| 857 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) |
| 858 | 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 859 | DOL Control panel |
| 860 | 40mm dia steel short piece |
| 861 | Well cap |
| 862 | 50mm size CI bracket |
| 863 | 2.50sqmm flat cable |
| 864 | 20mm dia rigid UPVC pipes |
| 865 | Steel rope with cover |
| 866 | Labour charges for lowering including transportation |
| 867 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge |
| 868 | 32mm HDPE pipes (Finolex/Supreme make) |
| 869 | 14,000 ltr capacity R.C.C. Under ground sump of in side size (2.80m x 2.80m x 2.0m) |
| 870 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 871 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 872 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 873 | Supplying all materials labour T&P filling sand in foundation and plinth with well watered and rammed etc. all complate. As per direction of ELC. |
| 874 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 875 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 876 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 877 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 878 | RCC floor, roof slab chhaja up to 4.430 m height |
| 879 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 880 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender