Tender For Construction Of 4 Nos Flat Type E Type Quarter Buildingat Rengali Phc For The Year 2023-24 In The Dist. Of Sambalpur
Tender Value
1.14 Crore
Estimated cost
Bid Submission
25 Nov 2026
6 days left
EMD
1.14 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sambalpur → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 4 Nos Flat Type E Type Quarter Buildingat Rengali Phc For The Year 2023-24 In The Dist. Of Sambalpur
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation in all kind of soil within 50 m initial loead and initieal lift, including dressing and levelling the bed etc. complete |
| 2 | Filling in foundation and plinth with excavated earth including watering and ramming as directed by the E.I.C. etc. complete |
| 3 | Supplying and filling foundation and plinth with sand wall watered and rammed with cost conveyance and royality, taxes of all materials and labour (T&P) etc. complete. |
| 4 | Cement Concrete (1:3:6) in Foundation using 4 cm size bhg metal including watering, curing with cost, conveyance, royalty and taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 5 | Cement Concrete (1:2:4) using 12mm size cbhg chips including watering, curing with cost, conveyance, royalty and taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 6 | R.C.C. M-20 using 20 mm & down size h.g.c.b chips including watering, curing with cost, conveyance, taxes and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 7 | For Column Base |
| 8 | Plinth Beam |
| 9 | Column / Beam (GF ) |
| 10 | Column / Beam ( FF ) |
| 11 | Column / Beam (SF ) |
| 12 | Lintel (GF & FF) |
| 13 | Sunshades (GF) |
| 14 | First floor |
| 15 | Second floor |
| 16 | R.C.C. Shelves (GF) |
| 17 | First floor |
| 18 | R.C.C. Stair (GF) |
| 19 | R.C.C. Stair (FF) |
| 20 | Roof Slab,landings&chajjas (GF) |
| 21 | Roof Slab,landings&chajjas (FF) |
| 22 | Roof Slab,landings&chajjas (SF) |
| 23 | Supplying ,Cutting, Bending, binding, tying and placing in position HYSD bars as per drawing including cost, conveyance, taxes of all materials and cost of all labour (T&P) etc. complete as per the direction of Engineer-in-Charge.Ground floor |
| 24 | First floor |
| 25 | Second floor |
| 26 | 20mm thick C.P. (1:4) as grading plaster including watering, curing, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. |
| 27 | Second floor |
| 28 | Fly Ash Brick masonry with CM (1:6) in Foundation & Plinth including watering, curing with cost, conveyance, royalty and taxes of all materials & labour (T&P) etc. complete as per the direction of Engineer-in-Charge. |
| 29 | Fly Ash Brick masonry with C.M. (1:6) in Superstructure using Fly Ash Bricks including watering and curing with cost, conveyance, royalty and all taxes of materials and labour (T&P) required for the work etc. complete as per direction of Engineer-in-Charge. (GF) |
| 30 | First floor |
| 31 | Second floor |
| 32 | 16 mm (5/8\\") thick cement plaster (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. (GF) |
| 33 | First floor |
| 34 | Second floor |
| 35 | 12mm thick C.P. (1:6) over brick walls finished smooth including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. (GF) |
| 36 | First floor |
| 37 | Second floor |
| 38 | Supplying, fitting, fixing of Vetrified tile flooring on 20mm thick bed of C.M. (1:4) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(GF) |
| 39 | First floor |
| 40 | Supplying, fitting, fixing of Vetrified tile in dados on 12mm thick C.P. (1:3) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. |
| 41 | First floor |
| 42 | Supplying, fitting, fixing of Ceramic Glazed Wall tile in walls on 12mm thick C.P. (1:3) jointed with neat cement slurry & pigment to match the shade including watering & curing with cost, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge. (GF) |
| 43 | First floor |
| 44 | Fixing tiles (Vitrified Industrial Tiles) in floors treads or steps and landing on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubing and polishing with cost,coveyance of all materials etc. complete. (GF) |
| 45 | Fixing of Granaite in floors treads or steps and landing on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubing and polishing with cost,coveyance of all materials etc. complete. (GF) |
| 46 | First floor |
| 47 | 6mm thick C.P. (1:4) as ceiling plaster including watering, curing, conveyance, royality & all taxes of materials & labour with T&P required for the work etc. complete as per direction of Engineer-in-Charge.(GF) |
| 48 | First floor |
| 49 | Providing, supplying and fitting and fixing of M.S. Door / Window shutters, gates & M.S. grills as per approved design etc. complete. |
| 50 | MS Door&Window |
| 51 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 52 | Providing fitting, fixing of 32 mm thick flush door shutter with approved quality of 30mm thick BWR block boad pasted with 1mm thick sunmika on both side of approved design and quality including cost of all door fittings and fixtures etc complete. |
| 53 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50 mm dia of 2 mm thick circular pipe with balustrade of size 32mm*32mm*2mm in 3 rows in staircase as per approved design and specification buffing, polishing etc complete |
| 54 | Providing, supplying and fitting and fixing of two track upvc sliding Window with 6 mm thick glass as per approved design etc. complete |
| 55 | Wall painting two coat with plastic emulsion paint over a coat of priming including cost of all meterials and labour etc.(GF) |
| 56 | First floor |
| 57 | Finishing wall surface with Acrylic wall putty (Water based) including cost of all materials and labour etc. complete. (GF) |
| 58 | First floor |
| 59 | Finishing out side wall surface with Weather Coat (I.S.I) two coats with any approved shade over a coat of priming including cost of all materials and labour (T&P) etc. complete as per the direction of Engineer-in-Charge. (GF) |
| 60 | First floor |
| 61 | Enamel Painting two coat with any approved paint over a coat of primer including cost of paint & labour. (GF) |
| 62 | First floor |
| 63 | Providing and laying 60 mm thick factory made cemenkt concrete interlocking pavor block of M-30 grade made by block makine machine with strong vibratory compaction of approved size ,design and shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand ,filling the joint with fine sand etc. all complete as per the direction of engineer-in-charge. |
| 64 | Dismantling and removing R.C.C Columns beam, slab ,staircase landing lintels including stacking the useful materials for reuse and removing the debris with in 50 mt lead. |
| 65 | Dismantling and removing brick or stone masonry up to 3m height including stacking the useful materials for reuse and ramming the debris with in 50m lead etc with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 66 | EI Work :- Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type -do- (Gr.A) (1.1.1-1.24.2) |
| 67 | -do- (Gr.B) (1.1.2-1.24.2) |
| 68 | -do- (Gr.C) (1.1.3-1.24.2) |
| 69 | S/F of M.S. Box for 2 Module 18 swg |
| 70 | S/F of M.S. Box for 4 Module 18 swg |
| 71 | S/F of M.S. Box for 12 Module 18 swg |
| 72 | S/F of 3 pin 5/6 A.F.T switch and.Socket on existing board (Modular type) (1.25.1+1.25.4) |
| 73 | S/Fof 6 module M.S. Box with Bakelite cover (Modular Type) on surface or in recess including providing and fixing of 2 nos 3 pin 5/6 amp. Socket out let 5/6amp. Piano type modular switch,connection,painting etc. as required (1.24.4 +2 x (1.25.1+1.25.4) |
| 74 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required |
| 75 | S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand) |
| 76 | S/F of 6 pin 15A modular socket on 2 Modular Metal box for A.C (1.25.5) |
| 77 | Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White).2x1.5 sqmm + 1 x 1.5 sqmm( 1 .8.1) |
| 78 | -do- 2 x 2.5 sqmm + 1 x 1.5 sqmm (1.8.2) |
| 79 | -do- 2x4 sqmm + 1 x 1.5 sqmm (1.8.3) |
| 80 | S/F of 5 to 32 Amp rating 240 Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution Board ISI marked complete with connection, testing and commissioning etc. as required (2.6.1) |
| 81 | S/F of MCB 8 Way Double Door (2.3.1) |
| 82 | S/F of 32A C series D.P. MCB for A.C (make: Legrand/Anchor/Havels/HPL) |
| 83 | Supply, Installation and commissioning of63 Amp. I.C.D.P. Main Switches (Sl.No. 1502) (IS 13940 Part 3/ 1993) on existing surface complete with H.R.C. fuse links, interconnections, earthing etc. as requiredas per direction of Engineer in- charge (Make Siemens/ HPL/Anchor/L&T/ Havels/ C&S/ R,K,) 2.15.1A |
| 84 | Supply of250 mm x 300 mm x100 mm deep(1.24.13) for fixing 63 Amp ICDP Main Switch. |
| 85 | S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30) |
| 86 | S/F of batten holder BK angle holder ISI marked including connection etc. insulated of ceiling rose(1.29- 1.28) |
| 87 | Earthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2+3.3) |
| 88 | Supply & laying 6 SWG G.I. wire in recess for loop earthing as required (3.17) |
| 89 | Invertor wiring (1x 1.5 sqmm) copper wire (1.19.1) |
| 90 | S/F of Fan hok S'type made of 16mm MS rod as per specificationn |
| 91 | S/F of step type modular fan regulator |
| 92 | S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton / Phillips/ HPL/ Polycab / Havells ) |
| 93 | Supply & Fixing of 45-48 Watt single L.E.D street light fitting with LED & Electrinic driver including all accessories and connections (Make:Crompton/Phillips/HPL/Polycab/Havells) |
| 94 | Supply of instalation, Testing commissioning of 12 Watt. LED bulb(Make: Havels / Phillps / Crompton / Polycab / HPL) |
| 95 | Supply, Installation, Testing and commissioning of 10W LED bulkhead fittings( (Make: Havels / Phillps / Crompton ) |
| 96 | S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB |
| 97 | S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS) |
| 98 | S/F OF 2000VA/12v Invertor with 2no 180Ah Battery including Trally arrangement. (Luminous/Microtek/Excide) |
| 99 | S/F of computer board consisting of 3 nos. of 5 amp modular plug and modular switch and 1no. Of 6 amp Mini MCB, complete with wiring on 12 modular type M.S.box with modular cover. |
| 100 | S/F of 18-25 watt LED Tube light fitting compoete with all connection.\ including fixing and all accessories as per direction of Engineer-In-charge (Make: Havels / Phillps / Crompton / Polycab / HPL) |
| 101 | PH Works Supplying all materials,labour,T&P and fitting & fixing of 4.0kgf/cm2 U-PVC soil waste ventilating pipes & fitting of the following O.D conforming to ISI No. 13592/1992 to walls with nails bobbins and wooden plugs or earthwork in excavation in all kinds of soil for laying in trenche including jointing with supply of approved rubber lubricant by non-heat application method/as per manufactures specification including tasting and refilling and trenches as per direction of E.I.C. (a)110mm dia pipe |
| 102 | (b)110mm dia PVC Door Tee |
| 103 | (c)110mm dia PVC P-Trap |
| 104 | (d)110mm dia PVC Door Bend |
| 105 | (e)110mm dia PVC Offset |
| 106 | (f)110mm dia PVC Plain bend |
| 107 | (g)110mm dia PVC cowl |
| 108 | (h)110mm dia PVC Plain Tee |
| 109 | (i)125mm dia CP Grating |
| 110 | Supplying all materials labour T&P and fixing water closet,squatting pan(Indian type WC pan/Orissa pattern squatting pan)dulyembedded in cc(1:5:10)using 4cm hg metal all complete as per the direction of E.I.C.(a)580mm Orissa pan(make-Cera,Parryware,Hindware) |
| 111 | Supplying all materials labour T&P and fixing wash down water closet(Anglo Indian water closetwith integral S or P trap to the floor with wooden plug and chromium plated crews including jointing the trap with soil pipe in cm1:1 etc. all complete as per specification and direction of E.I.C.(a)E.I.W.C. with S Trap with sheet covermake-Parryware,Hindware |
| 112 | Supplying all materials,labour,T&P and fixing kitchen sink with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc. all complete as per P.H. specification and direction of E.I.C.(a)600mmx450mmx200mm Steel sink with 40mm dia cp west,west pipe and brackets. |
| 113 | Supplying all materials,labour,T&P and fixing wash basing with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc. all complete as per P.H. specification and direction of E.I.C.(a)550mmx400mm WHB with 32mm dia cp west,west pipe,brackets and connection pipe.(make-parry ware) |
| 114 | Supplying all materials,labour T&P and fixing mirror of superior glass mounted on 6mm thick AC sheet or plywood sheet and fixing to wooden plugs with CP screws and washers complete as per PH specification and direction of E.I.C. (a) 600mmx450mm B.E. Mirror |
| 115 | Supplying all materials,labour T&P and fixing standard size glass shelf with CP brass bracket and guard rail complete fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C.(a)(125x600)mm size glass-shelf with CP Guard rail |
| 116 | Supplying all materials,labour T&P and fixing standard size CP towel rail complete with CP Brass brackets fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C.(a)25mmx600mm long CP towel rail (Make Parryware) |
| 117 | (b)CP Toilet Ring (Make Parryware) |
| 118 | Supplying all materials,labour T&P and fixing standard size CP soap holder complete with CP Brass brackets fixed to wooden plug with CP screws as per PH specification and direction of E.I.C.(a)CP Soap holder |
| 119 | Supplying all materials labour T&P and cutting holes through brick/stone masonary walls for taking HCI/PVC and fittings including making good the damages etc. all complete as per PH specification and direction of E.I.C. (a)375mm thick wall |
| 120 | (b)250mm thick wall |
| 121 | ( C) Roof Cutting |
| 122 | Supplying all materials labour T&P and fixing Digital tiles in floors,threads, landing on 25mm thick bed of cm(1:1)jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete including cost of precast tiles etc. all complete as per specification and direction of E.I.C. (i)Ground Floor:- |
| 123 | First floor |
| 124 | Supplying all materials labour T&P and fixing porcelain glazed digital tiles tiles in dados skirting and risers of step on 12mm thick CP(1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles etc. all complete as per spcificaiton and direction of E.I.C. Ground floor |
| 125 | First floor |
| 126 | Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member,9201 as top,9200 as bottom and middle member with frame section as 9221with tapered clip no 4660 & frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board.and as per direction of the E.I.C. |
| 127 | Supplying all materials labour T&P and constructing inspection chamber of the following sizes with cc(1:3:6)using 40mm size hg metal on bed,1st class KB brick work in cm(1:6)moulding & shaping the channel inside & benching with cc(1:1.5:3) using 12mm size hg chip,12mm thick CP(1:3)with punning to inside,cement flush pointing(1:3)to outside,RCC coverslab in cc(1:1.5:3)using 12mm size h.g. chips with RCC manhole cover,e.w. in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C.(a)Inside size 760mm x 760mm x 460mm |
| 128 | Supplying all labour T&P and constructing soakwaypit of the following sizes with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brickwork in cm(1:6)for the remaining height at top,12mm thick CP(1:4)inside and outside over masonary brick work,gravel packing in the rear of well steining RCC coverslab in cc(1:1.5:3)using 12mm size hg chips fitted handles including ew in openwell excavation in all kinds of soil and refilling the cavity around the pit & painting the iron works,watering,curing,conveyance of all meterails to worksite,payment of royality,taxes etc. all complete as per approved drawing specification and direction of E.I.C. (a) 1.20m dia x2.00 deep |
| 129 | Supplying all materials,labour,T&P and laying in trenches 4kg/cm2 U-PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches(to slope or level)and jointing with supply of approved solvent cement by non-heat application method cc(1:3:6)using 40mm size HG metal on bed of the trenches and all round concrete encashing with cc(1:4:8)using 40mm size HG metal, earthwork in excavation in trenches in all kinds of soil refilling the same in a layer of 0.30mtr with watering ramming and removing of surplus earth testing the S.W pipe line etc. all complete as per approved drawing specification and direction of the E.I.C. (a)110mm dia PVC pipe with allround encasing |
| 130 | Earth work in all kinds of soil in excavation of foundation trenches within 50m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of E.I.C. (a) Initial lift upto 1.50m |
| 131 | (b) From 1.50m to 3.00m depth |
| 132 | Supplying all materials labour T&P and filling foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site,payment of royality,taxes etc. all complete as per the direction of E.I.C. |
| 133 | Supplying all materials labour T&P and providing cc(1:3:6)using 4cm h.g metal including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 134 | Supplying all materials labour T&P and providing cc(1:1.5:3)using 12mm hg chips including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 135 | Supplying all materials labour T&P and providing KB Brick work in cm(1:4) F&P having crushing strength not less than 75kg/cm2 with dimensional tolerance +/-8% including watering,curing conveyance all materials to work site payment of royality taxes etc. all complete as per specification direction of E.I.C. |
| 136 | Supplying all materials,labour T&P and providing 12mm thick CP(1:3)on brick work including watering,curing conveyance of all materials to work site, payment of royality,taxes etc all complete as per specification and direction of E.I.C. |
| 137 | Supplying all materials labour T&P and providing cement punning for skirting including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C |
| 138 | Supplying all materials labour T&P and providing rigid and smooth centering & shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 139 | Supplying all materials labour T&P and providing MS reinforcement for RCC works including cutting,bending,binding & tying the grills and placing in position including cost of binding wire 18 to 20 gauge,conveyance of all materials to work site, payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 140 | Supplying all materials labour T&P and providing RCC(1:1.5:3)using 12mm hg chips for RCC works including hoisting,laying,watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 141 | Supplying all materials labour T&P and fixing MS step iron in 12mm dia MS steel bar and fixing into walls of septic tank duly embedded in cc(1:3:6)all complete as per PH. specification and direction E.I.C. |
| 142 | Supplying all materials labour T&P and fixing of RCC baffle wall precast with cc(1:1.5:3)using 12mm bhg chips and fitted to septic tank as per P.H. specification and direction E.I.C. |
| 143 | Supplying all materials,labour,T&P and providing fitting&fixing PVC 110mm dia PVC Tee in wall including fitting the necessary with cc(1:1.5:3)with 12mm size hg chips all complete including watering,curing,conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 144 | Supplying all materials labour T&P and Providing cement flush pointing(1:3)to brick masonary including watering,curing,conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C. |
| 145 | Supplying all materials labour T&P and providing 500x500x100mm thick RCC precast MH cover in cc(1:1.5:3)using 12mm hg chips placing the cover on the MH/S tank & finishing smooth all complete as per specification and direction of E.I.C. |
| 146 | Filling in foundation & plinth with excavated materials,including watering and ramming as per direction of E.I.C. |
| 147 | Supplying all materials,labour,T&P and construction of masonry staging with providing 1st class KB brickwork in cm(1:6)of 0.46m height in staging,12mm CP in cm(1:6),RCC beam of 0.25mx0.30mx 3.18m in cc(1:1.5:3)using 12mm size HG chips including centering, shuttering,bending and binding of rod etc watering,curring,conveyance of all materials to work site,payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.Supplying all materials,labour,T&P and construction of masonry staging with providing 1st class KB brickwork in cm(1:6)of 0.46m height in staging,12mm CP in cm(1:6),RCC beam of 0.25mx0.30mx 3.18m in cc(1:1.5:3)using 12mm size HG chips including centering, shuttering,bending and binding of rod etc watering,curring,conveyance of all materials to work site,payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 148 | Supplying all materials,labour,T&P and Fitting&Fixing of Rotational moulded polythene cylindrical vertical water storage tankconforming to 12701/1996including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts,including hoisting upto a height of 5mtr above GL and placing the tank in required position including conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.(a)2000Ltr. Capacity Water Storage Tank |
| 149 | Supplying all materials,labour,T&P and fitting & fixing 10ltr capacity LL flushing cystern with a pair of MS clamps complete with fittings such as syphonic arrangements 15mm nominal size PVC ball valve with polythene float,PVC handle,union and couplings for connection with inlet,outlet and overflow pipes, 32mm dia PVC flush bend,15mm dia,PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cystern and closet and connecting inlet pipe with supply main etc. all connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C. (a)10Lit. Capacity Flushing cistern(Make- Slimline,Cera,) |
| 150 | Supplying all materials,labour,T&P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89(sch-80)and pipe fitting of the following nominal bore with clamps including making good the wall,ceiling and floor testing all complete as per specification and direction of E.I.C.(a)32mm dia PVC pipe |
| 151 | (b)25mm dia C-PVC pipe |
| 152 | (C)20mm dia C-PVC pipe |
| 153 | Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4)for taking GI/PVC pipe & fitting etc. all complete as per PH specification and direction of E.I.C. Ground floor |
| 154 | First floor |
| 155 | Supplying all materials,labour,T&P cutting holes in RCC floors,roofs etc up to 19cm thick for passing GI/PVC pipes fittings and reparing the holes after insertion of pipe etc. with cc(1:1.5:3)including finishing so as to make it leak proof as per direction of E.I.C. Ground floor |
| 156 | First floor |
| 157 | Supplying all materials,labour,T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per direction of E.I.C. Ground floor |
| 158 | First floor |
| 159 | Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per PH specification and direction of E.I.C.(Amber make) (a)15mm dia CP Bib cock (Jaguar make) |
| 160 | 15mm dia CP(LB) Bib cock |
| 161 | 15mm dia CP Two way Bib cock |
| 162 | 15mm dia CP Pillar cock |
| 163 | 15mm dia CP Angle stop cock |
| 164 | 15mm dia CP Concealed stop cock |
| 165 | 15mm dia CP Revolving Shower with shower Arm |
| 166 | 15mm dia Health Faucet & 1.0m long Flexible pipe |
| 167 | 25mm dia PVC F.W.V. |
| 168 | 15mm dia CP Flange |
| 169 | 15mm dia CP Extension Piece |
| 170 | Supplying all materials,labour,T&P and fitting and fixing of ISI mark 1H.P single phase vertical water cool submersible pump set with discharge 1800/2200Lit/ Hour & a head-55/70mtr.of reputed make(CRI/KSB/Texmoor Equivelent) Including cost conveyance and taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 171 | Supplying all materials,labour,T&P and fitting & fixing of 1HP single phase vertical submersible pump set with commissioning and testing etc. all completes as per P.H. Specification and direction of E.I.C. |
| 172 | Supplying all materials,labour,T&P and fitting & fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1HP single phase vertical submersible pump set including all cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 173 | Supplying all materials labour T&P and fitting & fixing of 2.5mm2 3core copper flat suitable cable having ISI mark of reputed company like BCH/ Finolex or equivalent & connecting the pump starter including cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 174 | Supplying all materials labour T&P and fitting & fixing plastic rope with MS well cover,MS Clamp,stainless steel short piece,Bend & socket, union including all cost conveyance & taxes etc. all completes as per P.H. Specification direction of E.I.C. |
| 175 | Supplying all materials labour T&P and fitting&fixing of HDPE pipes and pipe fittings with making connection to pump set including all cost conveyance & taxes etc. all completes as per P.H. Specification direction of E.I.C. |
| 176 | supplying of all materials,labours,T&P and fitting&fixing of 5KVA voltage stabiliser having voltage range from 50volt to 290volt sutable to run 1.00HP sumersible pump set including electrial connection form the existing mains &with the controal panels of the pump set etc.all complete as per specification and direction of E.I.C. |
| 177 | 200mmx150mm Size Bore well Through DTH Method:- Labour for drilling of perfactly vertical bore holes as specified dia.For a specified depth rock with down the hole hammer drilling rig combination drilling rig as required to soil,the soil condition as per direction of E.I.C including supply of rigs with all accessories,T&P consumable etc for lowering 200mm dia PVC pipes for casing fitted with sockets,washers and without well screen as per the necessity for the soft,medium and hard formation(PCV/GI)casing pipes for the over borden is to be provided by the contractor including lowering and drawing after complete of tube well.Tube well(1No).(a)Drilling of 200mm. dia. Bore-0.00mtr to 44.40mtr |
| 178 | (b)Drilling 150mm dia. Bore-44.40mtr to 280.00mtr |
| 179 | Lowering the following GI/PVC pipe with or without soltted pipes as per necessity from GL upto 30.00mtr depth and fitted and fixed in perfecty vertical position including cutting and threading pipes and soltted pipes and supplying and fixing of all jointing materials,T&P etc the top of the casing pipe threaded including piping tube well to prevent entry of foreign materials from above(PVC/ GI)supplied by the contractor (including cost of pipe) (a)Lowring of 200mm dia pipes-0.00mtr to 44.40mtr |
| 180 | (b)Cost of 200mm dia PVC casing pipes-0.00m to 45.00m |
| 181 | Cleaning & developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of E.I.C. |
| 182 | Supplying and fitting and fixing of deep well India Mark-II hand pump with cast iron cylinder,12mm to 16mm dia connecting rod made with bright bar of 12mm dia mtr and 32mm dia G.I.Pipe 3.0mtr long with required depth with end of socket of approved rate as per the direction of E.I.C. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender