Tender For Land Development Of Water Logged Area Through Vertical Drainage Arrangement In Residential Area Of Municipal Corporation Narnaul City, Hsvp Sector And Surrounding Area. (Narnaul Constituency- Cm Announcement Code: 29217).
Tender Overview
Project Description
Tender for Land Development Of Water Logged Area Through Vertical Drainage Arrangement In Residential Area Of Municipal Corporation Narnaul City, Hsvp Sector And Surrounding Area. (Narnaul Constituency- Cm Announcement Code: 29217).
BOQ
| Sl. No. | Item Description |
| 1 | Providing, laying and Fixing of Galvanizes steel chain link both end twisted fence fabric having opening size 7.5x7.5 cm and 3.15 mm dia wire, 2.2 meter height of mesh, with 2.8 meter ht of MS Angle 50x50x5 mm supports fixing at spacing of 3 meter center to center, supports with MS Flat 35x5 mm. Fencing supported with MS Angle 35x35x5 at top and bottom and earthwork excavation pit. The M.S Angle supports shall be anchored in cement concrete (1:3:6) blocks 45x45x60 cm additional razor barbed wire fencing shall be provided at the top of mesh, fencing including gate |
| 2 | Supplying of G.I Tee 50mm i/d (ISI Marked) |
| 3 | Supplying of G.I union 50mm (ISI Marked) |
| 4 | Supplying of G.I Reducer 100x 50mm (ISI Marked) |
| 5 | Supplying of GM Ball valve 50mm i/dia (DRP make ISI marked) |
| 6 | Supplying of C.I. NRV 50mm (ISI marked) |
| 7 | Supplying of GI Elbow 50mm i/dia bore well (ISI Marked) |
| 8 | Supplying, erection, testing and commissioning of Variable Frequency Drive (VFD) complete with all accessories for the required power capacity of Solar Pump VFD Drive for Pump set of power capacity 7.5 HP |
| 9 | Supplying, erection, testing and commissioning of Variable Frequency Drive (VFD) complete with all accessories for the required power capacity of Solar Pump, VFD Drive for Pump set of power capacity 10 HP |
| 10 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade, SDR-17 and PN - 6 for Irrigation as per IS 4984: 2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 110mm HDPE Pipe |
| 11 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade, SDR-17 and PN - 6 for Irrigation as per IS 4984: 2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 160mm HDPE Pipe |
| 12 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade, SDR-17 and PN - 6 for Irrigation as per IS 4984: 2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 200mm HDPE Pipe |
| 13 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade, SDR-17 and PN - 6 for Irrigation as per IS 4984: 2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 250mm HDPE Pipe |
| 14 | Protection Box for DWLR contains size 0.60 mtr x 0.60 m x 0.50 mtr. |
| 15 | DWLR Piezometer ( Battery Operated) with Sensor and 50 m Cable with installation (Without GST) |
| 16 | LSG-V Wire wound screen pipe size 100 mm dia,6 mm thick ,0.75 mm Slot size IS-8110-2019 per Meter (Without GST ) |
| 17 | Credit of old Brick / Brick Bats |
| 18 | Supplying, erection testing and commissioning of submersible pumping sets (Reputed ISI Make i.e. Crampton/CRI/ BS/Taxmo) as per BIS SPECIFICATION No. 8034 - 1989 (as amended up to date for pumps ) and IS 9283 – 1979 (as amended up to date for motor ) the pump and motor sets should be capable of pumping clear fresh cold water having characteristics as specified in IS 8034 – 1989 and IS 9283 – 1979 as applicable as per design requirement and directions of Engineer-in-Charge (Submersible pumping set 7.50 HP) |
| 19 | Supplying, erection testing and commissioning of submersible pumping sets (Reputed ISI Make i.e. Crampton/CRI/ BS/Taxmo) as per BIS SPECIFICATION No. 8034 - 1989 (as amended up to date for pumps) and IS 9283 – 1979 (as amended up to date for motor) the pump and motor sets should be capable of pumping clear fresh cold water having characteristics as specified in IS 8034–1989 and IS 9283–1979 as applicable as per design requirement and directions of Engineer-in-Charge (Submersible pumping set 10.00 HP) |
| 20 | Provision for operation and running along with watch and ward for the period of 6 years inculding defect liability period after completion of work of whole infrastructure of land development of water logged area though vertical drainage arrangement i.e. Solar P.V. Panels, Inverters and Charge Controllers, Solar Pannel Mounting Structures, Cable and Wiring, Battery bank and other civil structures and Shallow Borewell for yielding and installing DWLR piezometer with sensor cable LSGV wire, Screen pipe including Submersible Pumping Machinery, GI lowering pipes, Submersible Cable, Electric Panel Board and Other Electromechanical Equipment`s and Sluice Valves, GI/CI/DI specials etc. complete in all respect should be done by the tendering agency as per direction of Engineer in-charge of work. Amount shall be payable to the agency on half yearly basis in 12 jobs after completion of work including defect liability period |
| 21 | Provision for maintenance of whole infrastructure for land development of waterlogged area through vertical drainage arrangement for the period of 5 years after completion of defect liability period at own expenses of contractor. The detailed geological and hydrological report should be submitted half yearly depicted the average drawdown of water level in whole project area including proper watch and ward of whole scope of work complete in all respect should be done by the tendering agency as per direction of Engineer in-charge of work. Amount shall be payable to the agency on half yearly basis in 10 jobs after completion of defect liability period. Any damage to pipeline due to whatsoever means shall be rectified by contractor only |
| 22 | Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength, anti-theft screws. Including lightning and surge voltage protection, Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to monitor plant performance (Amp-meter, Volt-meter, Frequency meter, Energy meter, Watt-meter, and other instrument/equipment as required). The minimum clear vertical height of the installed structure above the top of the foundation shall be at least 7 feet (2.134 metres) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 - requirements for testing, for safety qualification or equivalent IS and be mounted on fixed Aluminium/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electroluminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) including suitable foundation, design and drawing shall be duly vetted from government institute Including third party inspection. Solar plant complete in all respect as per satisfaction of Engineer-in-Charge. |
| 23 | Provision of final design and drawings of the proposed solar-powered dewatering system by an expert consultant having proven experience in similar works. The scope shall include a detailed Electrical Resistivity Survey of the affected area to determine suitable locations and depths of dewatering borewells, expected yield, adequacy of the proposed borewell network and anticipated groundwater drawdown, along with the design of pipelines for disposal of groundwater into Barkoda Minor and Narnaul Distributary, Solar Photovoltaic Power Plants with VFD-based pumping arrangements, and all associated civil, electrical and mechanical works. The design and drawings shall be vetted by a Government institution and approved by the competent authority before execution of the work. |
| 24 | Item Description HSR Item |
| 25 | H.S.R. Items Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender