Agriculture Boards / Undertakings / PSU Closing in 9 days TDR #58504990

Tender For annual repair maintenance Civil Works For The Year 2026-27 Sh: General Maintenance Works And Renovation Of G.No Mini 6 To Make It Storage Worthy At Fsd Tuticorin

Issued by Boards / Undertakings / PSU · Tuticorin, Tamil Nadu
Tender Value
42.85 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
9 days left
EMD
85720
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tuticorin → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for annual repair maintenance Civil Works For The Year 2026-27 Sh: General Maintenance Works And Renovation Of G.No Mini 6 To Make It Storage Worthy At Fsd Tuticorin

BOQ

Name of Work:- ARMO Civil Works for the year 2026-27 SH: General maintenance works and renovation of G.no Mini 6 to make it storage worthy at FSD Tuticorin
Sl. No. Item Description
1Taking out wind ties from roof including cutting outrusted bolts, nuts etc. and removing materials to anydistance within compound and stacking.
2Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.I. Sheet
3Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
4Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
5Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
6Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar
7Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand).
820 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
9Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
11Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
13Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
14Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover.
15Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately.Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
16Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm)
17White washing with lime to give an even shade: New work (three or more coats)
18Repurchase price of dismantled materials (to be paid by or recovered from the contractor work bill) inclusive of cost born for loading and unloading etc., by the contractor. Dismantled steel/iron flats, bolts, nuts etc.
19Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
20Providing and fixing radial exhaust turbo ventilator (extraction capacity of minimum 100 cft per minute air circulated fan of 22\\" throat dia wind ventilator with FRP base plate) including cost of fixing turbo/ wind ventilators on new 0.50mm thick pre-coated GI profile sheet roofing on godown roof including cost of transportation of all materials, tools and plants, fixtures/fastenings, labour insurance safet measures etc., and as directed by the Engineer-in-charge inlcuding guarantee for turbo ventilator of minimum 3 years and performance warranty etc., complete.
21Cleaning of drains by removing silt, sand, earth, sludge and dry leaves including cleaning of any other foreign matter if any such as organic/in organic materials etc.,for smooth running/free flow of rain water and disposal of cleaned material as directed by the Engineer in charge For drains of width above 0.30 m.
22Cleaning of drains by removing silt, sand, earth, sludge and dry leaves including cleaning of any other foreign matter if any such as organic/in organic materials etc.,for smooth running/free flow of rain water and disposal of cleaned material as directed by the Engineer in charge For drains of width up to 0.30 m.
23Providing and laying Two courses water proofing treatment with bitumen felt over roofs consisting of first courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt)including preparation of surface but excluding grading complete with : Bitumen felt (hessian base) type 3 grade I conforming to IS : 1322
24Tightening of Self drilling / Self tapping Screws in GI Profile sheet roofing including fixing of missing Screws, arresting roof leakage by providing GI washers/EPDM seal and filling the gap by providing weather silicon sealant over Self drilling / Self tapping Screws including providing safety measures for the labourers to work at higher elevation viz., ropes etc., insurance coverage for labourers and hiring of required T&P etc complete.
25Providing and Laying flash strip wherever required over roof including providing necessary safety measures for the labourers to work at higher elevation, ropes etc., insurance coverage for labourers and hiring of requiring T&P etc complete. (Analysed item with DSR 2023 rates)
26Servicing and repairs to rolling shutters by cleaning of side guides scrapping old grease, cleaning with kerosene oil, applying grease inside guides, removal of wall cover, application of proper tension to the springs correcting ball bearing, shaft replacement of damaged parts, removing and straightening of bend lathes fixing top cover and assuring smooth free and carry operations of rolling shutters etc. complete as directed by Engineer-in-charge including the cost of grease and necessary spare parts.
27Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
28Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
29Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
30Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
31Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars
32Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
33Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
34Providing and laying debonding layer of 125 micron thickness at the interface of cement concrete slab and 1:4:8 as per Engineer- In charge
3552 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
36Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
37Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
38Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm in required thickness, for all leads & lifts, all complete as per direction of Engineerin- charge.
39Providing and laying 60 mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58504990
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 42.85 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for annual repair maintenance Civil Works For The Year 2026-27 Sh: General Maintenance Works And Renovation Of G.No Mini 6 To Make It Storage Worthy At Fsd Tuticorin
Basic Detail
Tender No NIT 08 FSD Tuticorin ARMO
Bidding Type Tender
Location
City Tuticorin
State Tamil Nadu
Key Dates
Publish Date 12 Nov 2026
Submission Date 30 Nov 2026
Open Date 01 Dec 2026
Finance
Tender Value 42.85 Lakhs
Tender Fee Ref. Documents
EMD 85720
Exemption Not Available
Document List
53d46067-bbcd-43af-b64b-cfed44de6e42.html
BOQ_981647.xls
Tendernotice_1.pdf
ttnNIT.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Dec 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

53d46067-bbcd-43af-b64b-cfed44de6e42.html

xls

BOQ_981647.xls

pdf

Tendernotice_1.pdf

pdf

ttnNIT.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender