Tender For Repair/Up-Gradation Works At Chanderlok Building, Tilak Marg School, R1 & R2 Zonal Service Center Under Bm-I(E) Division
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Nov 2026
7 days left
EMD
19744
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Up-Gradation Works At Chanderlok Building, Tilak Marg School, R1 & R2 Zonal Service Center Under Bm-I(E) Division
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface /recessed steel conduit as required. a) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 2 | b) 2 x 16sq.mm + 1 x 6 sq.mm earth wire |
| 3 | c 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired a) 3 x 1.5 sq. mm |
| 5 | b) 3 x 2.5 sq. mm |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 7 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 AMPS |
| 8 | LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85% Operating voltage AC 140-270 Volt, frequency 50/60 hz Operating temp range -5 0C to 40 0C, interna surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained til life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (Asper ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in al respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)36 watt) For chanderlok building) |
| 9 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required 300 mm width X 50 mm depth X 1.6 mm thickness |
| 10 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable sizeMS/GI angle, bolts & nuts, painting suspenders, fastener etc as required300 mm width X 50 mm depth X 1.6 mm thickness |
| 11 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable sizeMS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 12 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 13 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (For Tilak Marg Sr. Sec School wing) 4 way (4 + 12), Double door |
| 14 | Taking down carefully existing electrical cables/wires PVC/flexible conduits and loose wires from existing installation, without damage, including dismantling of existing clamps, saddles, supports and fixing accessories, shifting the same to the existing cable tray and re-fixing/re-dressing in an orderly manner on the existing cable tray, including providing and fixing necessary GI/PVC clamps, cable ties, saddles, fasteners and other accessories as required, complete with proper segregation, dressing, securing and identification of cables, testing for continuity/insulation resistance wherever required, complete as required and as directed by the Engineer-in-Charge. ( Chanderlok Building) |
| 15 | S&F of Cubical board made out of CRCA sheet 16 SWG powder coated of suitable size 300 x 400 x 150 mm deep (nominal)suitable for supply and installation of MCCB 125amps 36KA breaking capacity, 4 pole 415Volt, copper bus-bar chamber having 4 Nos, 125 amps capacity, copper bus bar of size 25mm x 5mm one set of Amp and Volt meter with selector switch RYB indicating lights including wiring with 16sq. mm copper wire, thimbles, nut bolts along with grouting in the wall including connection testing, commissioning, painting and providing locking arrangement along with lock 65 mm size, provision for ventilating air fins, handle for opening of door, fixing of danger plate, including masonry/white washing work etc. complete as required at site.( Tilak Marg School primary wing) |
| 16 | Providing and laying electrical insulating mat conforming to IS 15652:2006 (IEC 61111), suitable for the system voltage, of approved class A category elastomeric type, complete in all respects, suitable for the voltage of the electrical installation, resistant to oil acid and low temperature, having non-slip/rough upper surface and plain or suitable slip-resistant underside inside lift machine room at terrace chanderlok building Mayur bhawan building ,Pragati bhawan building and fire brigade lane building , including cutting, jointing laying/fixing and all necessary accessories, complete as required and as directed by the Engineer-in-Charge. |
| 17 | S&F of Cubical board made out of CRCA sheet 16 SWG powder coated, of suitable size 500 x 500 x 200 mm deep (nominal), suitable for supply and installation of MCCB 250 Amps, 36 KA breaking capacity, 4 Pole, 415 Volt, copper bus-bar chamber having 4 Nos. 250 Amps capacity copper bus bars of size 50 mm x 5 mm, one set of Ampere and Volt meters with selector switch, RYB indicating lights, including provision for 3-phase energy meter with necessary CTs, wiring, terminals and accessories as required, including wiring with 16 sq mm copper wire, thimbles, nut bolts, along with grouting in the wall, including connection, testing and commissioning, painting and providing locking arrangement along with 65 mm size lock, provision for ventilating air fins, handle for opening of door, fixing of danger plate, including masonry/white washing work etc., complete as required at site. (R1, R2 Zonal Service Centre, Tilak Marg and Atal Aadarsh Sangli Mess School). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender