Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58504538

Tender For Repair/Maint Of Internal Wiring Including Replacement Of Electrical Fitments In Rs, Arjan, Tipnis And 10 Afh Area, Comprehensive Maintenance Stp And Connected Works And Comprehensive Maintenance Of Swimming Pool And Mechanical Laundry At 1

Issued by Statutory Bodies & Commissions/Committees · Jalpaiguri, West Bengal
Tender Value
39 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
18 days left
EMD
78000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal Wiring Including Replacement Of Electrical Fitments In Rs, Arjan, Tipnis And 10 Afh Area, Comprehensive Maintenance Stp And Connected Works And Comprehensive Maintenance Of Swimming Pool And Mechanical Laundry At 10 Afh At Af Station Hasimara

BOQ

Name of Work:- REPAIR/MAINT OF INTERNAL WIRING INCLUDING REPLACEMENT OF ELECTRICAL FITMENTS IN RS, ARJAN, TIPNIS AND 10 AFH AREA, COMPREHENSIVE MAINTENANCE STP AND CONNECTED WORKS AND COMPREHENSIVE MAINTENANCE OF SWIMMING POOL AND MECHANICAL LAUNDRY AT 10 AFH AT AF STATION HASIMARA
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:GE (AF) HASIMARA Name of Work : REPAIR/MAINT OF INTERNAL WIRING INCLUDING REPLACEMENT OF ELECTRICAL FITMENTS IN RS, ARJAN, TIPNIS AND 10 AFH AREA, COMPREHENSIVE MAINTENANCE STP AND CONNECTED WORKS AND COMPREHENSIVE MAINTENANCE OF SWIMMING POOL AND MECHANICAL LAUNDRY AT 10 AFH AT AF STATION HASIMARA Contract No: GE/HAS/ /2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Taking down carefully copper/aluminium point wiring complete (light, fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting, regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc, complete all as specified and directed.
3M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including concealed, rigid PVC conduit (ISI marked) not less than 20mm dia, medium grade, including all conduit accessories with and including concealed modular box of suitable size for mounting modular switch, sockets, fan regulator etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole, complete all as specified and directed.Note: - (i) Rate quoted shall deemed to be included for cost of modular box (as per number of module of outer cover) and concealed in wall including cutting and sinking of boxes and making good to the walls. (ii) Provision of blank plates as per site requirement, shall deemed to be included in the unit quoted rate.
4All as per item No 2.00 here-in before but for 3 pin 5 Amp socket point on same board, complete all as specified and directed.
5All as per item No 2.00 here-in before but for 3 pin 5 Amp socket point on independent board, complete all as specified and directed.
6All as per ser item No. 2.00 here-in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent, complete all as specified and directed.
7All as per item No 2.00 here-in before but with 4.0 Sqmm PVC insulated unsheathed multi stranded cable FRLSH type for one 3 pin socket outlet 15 Amp, independent including PVC insulated 4.0 Sqmm FRLSH type copper multi stranded conductor as earth wire including steel box of required for modular switches/sockets for 3 pin socket outlet point, 15 Amp on independent board and industrial socket for geyser, complete all as specified and directed.
8S&F switch, modular type, single pole, one way, 6 Amp, one module, complete all as specified and directed.
9S&F switch, modular type, single pole, one way, 16 Amp, one module, complete all as specified and directed.
10S&F bell push, modular type, single pole, 6 Amp, one module, complete all as specified and directed.
11S&F socket outlet, modular type, multipurpose, having provision for 5 pin, 6 Amp, combined, two module, complete all as specified and directed.
12S&F socket outlet, modular type, multipurpose, having provision for 2/3 pin, 6Amp/16 Amp, combined, two module, complete all as specified and directed.
13S&F decorative modular cover plate with frame, 2 module, white, completes all as specified and directed.
14S&F decorative modular cover plate with frame, 3 module, white, completes all as specified and directed.
15S&F decorative modular cover plate with frame, 4 module, white, completes all as specified and directed.
16S&F decorative modular cover plate with frame, 6 module, white, completes all as specified and directed.
17S&F decorative modular cover plate with frame, 8 module, white, completes all as specified and directed.
18S&F modular surface mounting plastic box of size 3\\" x 3\\", 1 & 2 module, completes all as specified and directed.
19S&F modular surface mounting plastic box of size 4\\" x 3\\", 3 module, completes all as specified and directed.
20S&F modular surface mounting plastic box of size 5\\" x 3\\", 4 module, completes all as specified and directed.
21S&F modular surface mounting plastic box of size 6\\" x 3\\", 6 module, completes all as specified and directed.
22S&F modular surface mounting plastic box of size 8\\" x 3\\", 8 module, completes all as specified and directed.
23S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection, 240 volts, 4 way, with rated copper busbar (as per OEM), neutral link for fixing MCBs/Isolators and necessary lugs for incomming and outgoing connection including taking down old unserviceable MCB DB of any description, completes all as specified and directed.
24S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection, 240 volts, 8 way, with rated copper busbar (as per OEM), neutral link for fixing MCBs/Isolators and necessary lugs for incomming and outgoing connection including taking down old unserviceable MCB DB of any description, completes all as specified and directed.
25S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection, 240 volts, 12 way, with rated copper busbar (as per OEM), neutral link for fixing MCBs/Isolators and necessary lugs for incomming and outgoing connection including taking down old unserviceable MCB DB of any description, completes all as specified and directed.
26Re-fixing only MCB SP/SPN/TP of any capacity, fixed in proper position including connection, complete all as specified and directed.Note : Serviceable MCBs obtained from old DBs shall be reused.
27S&F in replacement recessed mounted LED light fittings 36/42 watt (size 2' x 2'), energy efficient, decorative type suitable for armstrong/grip ceiling, with its supper bright LED hight upto 18m, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and directed.
28S&F power unit suitable for load max up to 3.5 KW including 2 module box and cover plate for mounting of power unit, complete as specified and directed.
29S & F in replacement of 15 Watt down light fittings, LED with round profile (circular shape) extruded suitable for fixing in ceiling/receess mounted, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5m length, complete all as specified and directed.
30S & F 10 W LED bulk head light fitting, comprising of connector galvanised cast iron back plate, weather proof, IP 65 protection with electronic driver, (latest design), upper PVC body including one 10 W LED lamp pre-wired, connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and directed
31S&F in replacement decorative, wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with and including 9/10 Watt LED lamp, B22 base fittings, complete all as specified and directed
32M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor cable 6 Sqmm, 1100Volts grade, FRLSH type, drawn in and including heavy duty rigid PVC concealed conduit (ISI marked) not less than 20mm dia with fixing accessories including 6 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multistranded flexible copper conductor cable as continuous earth wire and connecting to common earth dolly including taking down old unserviceable sub-main wiring, complete all as specified and directed.Note:-(i) Two runs of single core cable with one run of earth continuity conductor including PVC conduit shall be measured and paid as one length.(ii) Cutting chases for conduit and sinking of boxes and making good to wall floors etc shall deemed to be including in the unit quoted rate.
33M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor cable 4 Sqmm, 1100Volts grade, FRLSH type, drawn in and including heavy duty rigid PVC concealed conduit (ISI marked) not less than 20mm dia with fixing accessories including 4 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multistranded flexible copper conductor cable as continuous earth wire and connecting to common earth dolly including taking down old unserviceable sub-main wiring, complete all as specified and directed.Note:-(i) Two runs of single core cable with one run of earth continuity conductor including PVC conduit shall be measured and paid as one length.(ii) Cutting chases for conduit and sinking of boxes and making good to wall floors etc shall deemed to be including in the unit quoted rate.
34M&L for point wiring with multistranded copper conductor cable, PVC insulated and unsheathed (FRLSH) size 1.5 sqmm drawn in and including PVC casing and caping (ISI marked) with fixing accessories, with surface mounted PVC box of sutable size, for one light /fan point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet / modular plate incl continous earth wire of PVC insulated unsheathed, (FRLSH) multi stranded copper conductor cable of size 1.5 Sqmm for earth wire connected to common earth dolly for one light/fan point/bell point controlled by one, one way switch single pole including taking down old unserviceable point wiring, complete all as specified and directed.
35All as per item No 33.00 here-in before but one 3 pin 5 Amps socket outlet on the independent board controlled by other swtich, complete all as specified and directed.
36All as per item No 33.00 here-in before but one 3 pin 5 Amps socket outlet on same board controlled by other switch, complete all as specified and directed.
37All as per ser item No. 33.00 here in above but for one 16 Amp 3/5 pin switch socket outlet independent point including PVC cable 4 Sqmm, FRLSH type, multistranded copper stranded conductor along with 4 Sqmm continious PVC insulated unsheathed multistranded copper conductor cable, FRLSH type, as earth wire, complete all as specified and directed.
38S&F in repair switch piano, flush type, single pole, one way, 6 amps 240 volts, complete all as specified and directed.
39S&F bell push, single pole, 6 Amp, complete all as specified and directed.
40S&F socket outlet 2 in 1, 3 pin, 6 Amp, flush type, complete all as specified and directed.
41S&F switch and socket combination 2 in 1, 3 pin, 6 Amp, flush type, complete all as specified and directed.
42S&F switch and socket combination 3 pin, 16 Amp, flush type, complete all as specified and directed.
43S&F fan regulator, deluxe rotary step type, complete all as specified and directed.
44S & F angle lamp holder, PVC/polycarbonate type, complete all as specified and directed.
45S&F bell push, flush type 5 Amp, complete all as specified and directed.
46S&F ceiling rose, surface bakelite PVC/ polycarbonate, isolated body with three terminals, complete all as specified and directed.
47M&L for sub main wiring with two run of 6 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable (FRLSH) 1100 Volt grade, drawn through and including PVC casing caping (ISI marked) including all accessories and one run of 6 Sqmm single core PVC insulated unsheathed (FRLSH) copper earth continuity conductor including taking down old unserviceable sub main wiring, complete all as specified and directed. (Note : Two runs of 6 Sqmm single core cable with one run of earth continuity conductor including PVC casing caping and its accessories shall be measured and paid as one length).
48M&L for sub main wiring with two run of 4 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable (FRLSH) 1100 Volt grade, drawn through and including PVC casing caping (ISI marked) including all accessories and one run of 4 Sqmm single core PVC insulated unsheathed (FRLSH) copper earth continuity conductor including taking down old unserviceable sub main wiring, complete all as specified and directed. (Note : Two runs of 4 Sqmm single core cable with one run of earth continuity conductor including PVC casing caping and its accessories shall be measured and paid as one length).
49S & F energy efficient 5 star rated 300mm PVC air ventilating fan, high speed, complete with louvers and connecting wire up to nearest ceiling rose including taking down old unserviceable fan of any sweep, complete all as specified and as directed.
50S & F energy efficient 5 star rated 250mm PVC air ventilating fan, high speed, complete with louvers and connecting wire up to nearest ceiling rose including taking down old unserviceable fan of any sweep, complete all as specified and as directed.
51S & F in repair 4mm dia GI wire earth continuity conductor or main earthing lead, ixed to wall on batten or recess or chase or buried in ground or drawn in conduit/pipe or fixed to pole or other indicated situation for loop earthing etc, complete all as specified and directed
52S&F in repair rigid non-metallic PVC conduit, medium grade, external dia 20mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bellmouth tube ends andfixing accessories such as couplers, lock nuts, saddles, pipe hoos etc, complete all as specified and directed.
53M &L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0cm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI earth strip 25 x 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part -1, including necessary excavation and earth work, P.C.C (1:3:6) type C-1 with 50mm thick Pre-cast R.C.C. (1:2:4) type B1 cover slab (reinforced with 8mm dia deformed bar 10cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 25mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, Gl earth wire protected by 40mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantling of old unserviceable earthing of any descriprtion, complete all as specified and as directed.Note : Proper earthing pit shall be provided with pit cover.
54All as per item No 52.00 here-in before but galvanised wire 4mm dia, complete all as specified and as directed.
55Disconnecting all electric and water supply connections and other related items and lifting the unserviceable non clog Submersible motor and pump of capacity 12 HP, 3 phase, 415 V, from sewage sump by mechanical/manual method and dismantling the column pipe line, shafts stage and keeping the same in safe custody for reuse including transportation of the defective pump set and motor from pump house to workshop for repair and back and lowering and re-installation the same on exisisting position after necessary repair including testing on completion, complete all as specified and directed. (Note : Cost of repair including testing shall also deemed to be included in the unit quoted rate.)
56Dismantling the unserviceable parts and burnt out copper winding from pump and motor of capacity 12 HP, 3 phase, 415V, and rewinding the motor with supper enamelled copper wire of suitable gauge including heating, varnishing, replacement of defective spare parts, re-assembling and painting the motor with two coats of supper enamelled paint and carrying out necessary tests in presence of Engr-in-Charge at site, complete all as specified and directed. (Note:- (i) Spare/parts, copper winding wire shall be measured & paid seperately as 'supply only' under respective items. (ii) Labour charge for fixing parts shall deemed to be included in the unit rate.)
57Supply only super enamelled copper winding wire of suitable gauge as per capacity/rating of motor, complete all as specified and directed.
58Taking down the unserviceable parts from the non clog submersible pump of capacity 12 HP, 3 phase, 415 V including over hauling, servicing/cleaning throughly discharge/suction cases, impellers, shaft and re-assembling pump carefully including servicing , cleaning and painting the parts with two coats water proofing supper enamelled paint after preperation of surfaces manualy including repair/replacement of unservicable parts as required at site etc and re-assembling/re-installing the pump, complete all as specified and directed. Note:- (i) Spare/parts shall be measured & paid seperately as 'supply only'.(ii) Labour charge for fixing parts shall deemed to be included in the unit quoted rate.
59M & L for machine work to the worn out portion of non clog submersible pump shaft of capacity 7.5 HP capacity including metalling, cutting, polishing and checking the accuracy on the lath machine, complete all as specified and directed.
60Supply only ball bearing for non clog submersible motor as per existing, complete all as specified and directed.
61Supply only mechanical seal for non clog submersible motor as per existing, complete all as specified and directed.
62Supply only hydraulic oil for non clog submersible motor as per existing, complete all as specified and directed.
63Supply only impeller as per existing, complete all as specified and directed.
64Supply only impeller key as per existing, complete all as specified and directed.
65Supply only gun metal bush for vertical non-clog pump sets upto 12 HP capacity, complete all as specified and directed.
66Supply only neck ring (bronze), complete all as specified and directed.
67Supply only guide ring, complete all as specified and directed.
68Supply only lock bolt for impeller , complete all as specified and directed.
69Supply only shaft sleeve, complete all as specified and directed.
70Supply only oil seal for L B H, complete all as specified and directed.
71Supply only oil seal for I B H, complete all as specified and directed.
72Supply only grease pot for ball bearing, complete all as specified and directed.
73Supply only shaft coupling (screwed), complete all as specified and directed.
74Supply only coupling pin & bush, complete all as specified and directed.
75Supply only ball bearing, complete all as specified and directed.
76Supply only engine oil, complete all as specified and directed.
77Supply only lock bolt for shaft coupling, complete all as specified and directed.
78Supply only top shaft, complete all as specified and directed.
79Supply only bearing ring for suction cover for horizontal pump sets upto 12.5HP capacity, complete all as specified and directed.
80Supply only gasket (asbestos), complete all as specified and directed.
81Supply only gland cover with stuffing box, complete all as specified and directed.
82Supply only gland packing (5 Nos in one set), complete all as specified and directed.
83Supply only ball bearing (N.D.E), complete all as specified and directed.
84Supply only thrust bearing (D.E), complete all as specified and directed.
85S&F in replacement rubber coupling/spider coupling, flexible type suitable for upto 10 HP pump set, complete all as specified and directed.
86S&F in repair fully automatic (FASD) star delta starter along with single phase preventor in powder coated enclosure with PU gasket suitable for 10 HP pump including all electric connection with ammeter and volt meter on/off & trip indicator including protection against phase failure, phase imbalance, phase reversal, complete all as specified and directed.
87Repair/servicing of existing sluice valve of 80/100mm bore after dismantling of upper cover, remove the spindle and make it leak proof by replace the gland packing ,nut bolt with washer and gasket of both side, complete all as specified and directed.
88Repair/servicing of existing sluice valve of 150mm bore after dismantling of upper cover, remove the spindle and make it leak proof by replace the gland packing ,nut bolt with washer and gasket of both side, complete all as specified and directed.
89M&L for taking out primary and secondary bio filters assembly complete for overhauling, dismantling its components, replacing of gaskets, applying of grease to the steel balls, replacing of U/S steel ball and re-assembling after completion of overhauling, complete all as specified and directed.
90Bailing out the sludge/containminated water (organic or inorganic) including other foreign materials from sewage sumps of various sizes and depths as required by pumping with suitable pumping machinery and removing the same within 50m distance and disinfecting the area with sufficient quantity of bleaching powder and including removing and refixing of manhole covers as required, complete all as specified and directed.Note: (i) Temporary barricade and providing sufficient bleaching powder shall deemed to be included in the unit quoted rate.(ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate.(iii) The operation shall be carried out once in every three months and every time shall be measured and paid saperately.
91Taking out/bailing out the sludge/semi solid materials including other foreign materials from sewage sumps of various sizes and depths as required by pumping with suitable pumping machinery and taking out sludge/semi solid materials/any other foreign materials from septic tanks etc and removing the sludge within 50m distance and deposited in a pit to be excavated and disinfecting the area with sufficeint quantity of bleaching powder over the earth fill and covered with earth filling upto 30cm depth of pit including removing and refixing of manhole covers as required, complete all as specified and directed.(Note: (i) Excavation and earth work for pit, bamboo matting, temporary barricade of the pit and providing sufficient bleaching powder shall deemed to be included in the unit quoted rate. (ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate. (iii) The operation shall be carried out once in every three months and every time shall be measured and paid saperately.
92Surface dressing n. exc. 15cm deep in soft/loose soil, removing shrubs, small trees of height upto 1m, removing the the grass and creepers from root and spraying grass killing chemical (GLYCEL 41% SL or similar chemical as approved by Eng-in-Charge) with spray gun, as per manufacturer's instructions for prevention of weeds and grass at surrounding of STP, removing of waste materials and grasses n. exc 50m distance from installations, depositing where directed at a level n. exc. 1.5m above the starting points, complete all as specified and directed.Note : (i) The cleaning can be carried out at an interval of not less than 4 months (on requirement basis) at same loction/installation and proper register should be maintained and to be produced alongwith RAR/Final bill.(ii) Removing of all waste materials and grass to a distance n. exc. 50m from the installation an dcleaning the yard shall deemed to be included in the unit quoted rate.
93Supply and spreading unslaked lime at surrounding of pump house to destroy the roots of grass and herbs (average 300 gm per Sqm), complete all as specified and directed.
94M&L for testing and submit raw sewage water and treated water and submit the following test results:- (a) Samples to be taken from sewage pumping station Near Bala Ji Mandir, Near DSC accn, Near R S Ground, Near FWC & treated water from Main STP .(b) Submit all samples at the nearest Govt Test lab. The test for the following parameters has to be carried out:-(i) BOD (ii) COD (iii) Oil & Grease (iv) PH Value (v) TSS (vi) Feacel Colliform (vii) Residule chlorine (c) Submit the test report duly signed by appropriate Govt authority in every three month, complete all as specified and directed.
95Taking out existing boulders (75 to 200mm size) complete from primary bio filter bed of dia 8.20m, depth of boulders bed 1.6m, cleaning the boulders using fresh water, cleaning bottom surface of the filter bed and re-filling the filter bed after cleaning boulders and removing the wastage/sediments out side defence land, complete all as specified and direccted.
96All as per item No 94.00 here-in- before but from secondary bio filter of dia 10.10m and depth of boulders 1.6m, complete all as specified and directed.
97Supply and lay boulders of size 75mm to 200mm in primary and secondary bio - filters, complete all as specified and directed.
98M&L for preparation of old painted steel surfaces of any description, over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint (1st grade quality), complete all as specified and directed.
99Complete servicing of electrically operated Washer Extractor Machine (make : STEFAB) 15 Kg capacity front loading type auto controlled with elect motor 3 PH 415 V, including maintenance of complete electrical control panel, seal, door locking arrangement, maint of shaft, pully, inner drum including minor repairs, adjustments, lubrication, descaling of stainless steel drum by proper descaling compound to remove scale from the perforated body for proper cleaning of cloth and economy of the usage of steam, complete all as specified and directed.
100Complete servicing of electrically operated Drying Tumbler Machine (make : STEFAB) 15 Kg capacity front loading type heating arrangement auto controlled with elect motor 3 PH 415 V, including maintenance of complete electrical control panel, seal, door locking arrangement, maint of shaft, pully, inner drum including minor repairs, adjustments, lubrication,complete all as specified and directed.
101Complete servicing of electrically operated dry work press air operated auto timed, bed press machine capacity front loading type steam arrangement auto controlled with elect motor 3 PH 415 V (make : STEFAB), including maintenance of complete electrical control panel, seal, door locking arrangement, maint of shaft, pully, inner drum including minor repairs, adjustments, lubrication except, complete all as specified and directed.
102Complete servicing of electrically operated reciprocating Air Compressor 10 Kg per cm 2 capacity complete include, topping up of Mobil oil, complete Mobil oil is to be replaced completely once in a year, complete all as specified and directed.
103Complete servicing of electrically operated steam generator 4 Kg per hour complete include, topping up of Mobil oil complete Mobil oil is to be replaced completely once in a year, complete all as specified and directed.
104Rewinding of elect motor induction 3 ph. 415 V, 50 C/S, 2 HP capacity with supper enamelled copper wire of suitable gauge and insulating materials, heat varnishing complete including changing of ball bearing 3 Nos, complete all as specified and directed.
105S & F in repair Air solenoid valve 4 way 5 point, 220 volt AC 1/4\\" BSP for hydralic bed press, complete all as specified and directed.
106S & F in repair steam hose pipe covered with galvanized metalic stripes (as per exixting) for hydralic bed press, complete all as specified and directed.
107S & F in repair steam rubber hose covered with galvanized metalic stripes (as per exixting) for hydralic bed press, complete all as specified and directed.
108S & F in repair contacter 0-25 Amp for hydralic bed press, complete all as specified and directed.
109S & F in repair safety valve for hydralic bed press, complete all as specified and directed.
110S & F in repair padding cloth for hydralic bed press, complete all as specified and directed.
111S & F in repair ball bearing for washing machine (as per sample) for washing machine, complete all as specified and directed.
112S & F in repair water solenoid valve for washing machine, complete all as specified and directed.
113S & F in repair contacter 0-25 Amp for washing machine, complete all as specified and directed.
114S & F in repair over load relay for washing machine, complete all as specified and directed.
115S & F in repair limit switch for washing machine, complete all as specified and directed.
116S & F in repair PLC for washing machine, complete all as specified and directed.
117S & F in repair VFD (variable frequency drive) for washing machine, complete all as specified and directed.
118S & F in repair door gasket for washing machine, complete all as specified and directed.
119S & F in repair V belt (as per sample) for washing machine, complete all as specified and directed.
120S & F in repair electrical heater 1 KW fin type suitable for drying tumbler (as per sample) for drying tumbler, complete all as specified and directed.
121S & F in repair limit switch for drying tumbler, complete all as specified and directed.
122S & F in repair contacter 0-25 Amp for drying tumbler, complete all as specified and directed.
123S & F in repair ball bearing for drying tumbler, complete all as specified and directed.
124S & F in repair temperature prob (as per sample) for drying tumbler, complete all as specified and directed.
125S & F of electrical heater 1 KW for steam generator (as per sample) after taking out of unserviceable parts for steam generato, complete all as specified and directed.
126S & F of V belt for Air compressor (as per sample) after taking out of unserviceable V - belt, complete all as specified and directed.
127S & F in replacement of compressor oil for Air compressor (as per sample), complete all as specified and directed.
128S&F in repair 25mm bore gun metal, globe or gate valve, ISI marked, with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.
129S&F in repair 20mm bore gun metal, globe or gate valve, ISI marked, with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.
130S&F in repair 15mm bore gun metal, globe or gate valve, ISI marked, with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.
131Preventive maintenance of swiming pool comprising of 02 Nos centrifugal pump of 10 HP (01 main pump & 01 stand by pump) and 01 No. of vacuum pump, sand filter (02 Nos), electric dosing pump (01 No), microprocessor based constant current technology water disinfector work is to be carried out, with prior intimation, in every month, complete all as specifiied and directed.
132S&F in replacement telescopic rode 5 - 10m with handle and adaptor, as per existing, complete all as specifiied and directed.
133S&F in replacement for leaf rakes net made in polypropelene and white polyester netting clip type connection, as per existing, complete all as specifiied and directed.
134S&F in replacement for curved brush made in polypropelene and white polyester netting clip type connection, as per existing, complete all as specifiied and directed.
135S&F in replacement pump impeller (plastic), as per existing, complete all as specifiied and directed.
136S&F in replacement pump fan with cover, as per existing, complete all as specifiied and directed.
137Supply, installation, testing & commissionig pre-filter basket, as per existing, including taking down old unserviceable one, complete all as specifiied and directed.
138Supply, installation, testing & commission 75mm bore PTMT ball valve, as per existing, including taking down old unserviceable one, complete all as specifiied and directed.
139Supply, installation, testing & commission 90mm bore PTMT ball valve, as per existing, including taking down old unserviceable one, complete all as specifiied and directed.
140Supply, installation, testing & commission 75mm bore CI non return valve with flanges and adaptor, as per existing, including taking down old one, complete all as specifiied and directed.
141Supply only testing kit for test of PH, PPM, complete all as specifiied and directed.
142Supply only TCCA 90 bag of 50 Kg, as per existing, complete all as specifiied and directed.
143Supply only algaecide bag of 12 ltr box, as per existing, complete all as specifiied and directed.
144S&F in replacement 30m spiral wound hose pipe, crush proof, polyethylene vinyl hose with a 360 degree swivel cuff, complete all as specifiied and directed.
145S&F in replacement metallic vacuum head made of anodized aluminium/stainless steel, weight range not below 3 kg fited with smooth rolling wheels to glide easily across surface without scratching and bristle/brushes, complete all as specifiied and directe
146S&F in repair under water light LED light 6 W, 12V including all necessary fitting, complete all as specifiied and directed.
147S&F in repair 300 VA transformer suitable for under water light, as per existing, complete all as specifiied and directed.
148Supply and filling in replacement sand 0.4 to 0.8mm in sand filter including getting out old sand from the filter, complete all as specifiied and directed.
149S&F in repair direct on line starter, powder coated enclosure with PU gasket suitable for 3 HP motor including all electric connection with ammeter and volt meter including testing, complete all as specifiied and directed.
150Note: An amount of Rs.69,936.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58504538
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39 Lakhs
LAST DATE 03-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Internal Wiring Including Replacement Of Electrical Fitments In Rs, Arjan, Tipnis And 10 Afh Area, Comprehensive Maintenance Stp And Connected Works And Comprehensive Maintenance Of Swimming Pool And Mechanical Laundry At 10 Afh At Af Station Hasimara
Basic Detail
Tender No C/8135/2026-27/E8
Bidding Type Tender
Location
City Jalpaiguri
State West Bengal
Key Dates
Publish Date 12 Nov 2026
Submission Date 03 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value 39 Lakhs
Tender Fee 500
EMD 78000
Exemption Available
Document List
b8d952ea-9346-4a83-bfe7-49dd9b4ad908.html
BOQ_895698.xls
Tender8135.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

b8d952ea-9346-4a83-bfe7-49dd9b4ad908.html

xls

BOQ_895698.xls

pdf

Tender8135.pdf

pdf

Tendernotice_1.pdf

Disclaimer