Public Administrative Department Government Departments Closing in 6 days TDR #58503206

Tender For Annual Plan-Electrification Of Center No 120 Karikunnu Anganwadi Building - Kuruva Gp-Proj No : S0187/27-General Electrical Work

Issued by Government Departments · Malappuram, Kerala
Tender Value
1.44 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
6 days left
EMD
3616
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Plan-Electrification Of Center No 120 Karikunnu Anganwadi Building - Kuruva Gp-Proj No : S0187/27-General Electrical Work

BOQ

Name of Work:- Annual Plan-Electrification of Center No 120 Karikunnu Anganwadi Building - Kuruva GP-Proj No : S0187/27-General Electrical Work
Sl. No. Item Description
1Electrical
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
31.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
41.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
51.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
61.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
71.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
81.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
91.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1090.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1190.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
121.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
131.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1490.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
151.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1690.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
17OD192771/2026-2027:Supply, Conveyance, Installation, testing and commissioning of 400mm sweep metal blade and metal body type wall mounting fan (Orient,Havells,Bajaj,Crompton)
181.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1990.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
201.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
21OD192770/2026-2027:Supply and fixing of 9W LED Bulb, as required
221.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
232.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door
242.10.2:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole and netural
252.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
262.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
272.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
28OD192775/2026-2027:Supply and installation of dust and vermin proof Three-phase Sintex Meter Board (GS MB6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required
29OD192767/2026-2027:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
30OD192774/2026-2027:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
315.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
325.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
33OD192768/2026-2027:Supply, providing and fixing 2 x 25 x 3mm GI strip test joint and providing 25x6mm brass nut and bolt etc. and connection as required for earthing system
34OD192773/2026-2027:Supply, providing and fixing 25 x 3mm GI Strip earth lead from the test joint to earth plate
351.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
36OD192772/2026-2027:Charges for preparation of KSEB or KSELB test Report, drawings and other related documents etc as required by the contractor as per the instruction from the Assistant Engineer and submit it to the concerned KSEB section office or KSELB including application fee. Copy of application fee and related documents are to be submitted to the concerned Assistant Engineer.
37OD192769/2026-2027:Supply, installation testing and commissioning of 1TR 3 star rated split Inverter type air- conditioner unit conforming to IS 1391(Part2/92) suitable for operation on 230V+/- 10% 50 Hz single phase AC supply fitted with hermetically sealed compressor operating on R22/ono CFC refringent with condensing and evaporating unit capable for cooling air circulation and filtering etc. Including refringent copper piping with insulation up to 5 Meter or required length microprocessor control with cordless remote control and providing wall mounting stand for the outdoor unit etc-Inverter AC (With extended two year warranty period). Blue star /LG. Along with Supply and Fixing of 4KVA Voltage stabilizer V Guard with input voltage of 170 -270V and Output Voltage range of 210 to 240V with Overload Protection time relay, Indicators and Chord Wire etc as required
38OD192778/2026-2027:Supply, Fixing, Installation and Commissioning of 32 Inch, LED Google TV. (Sony/Samsung/LG) with superior quality Stabilizer(V-Guard or Equivalent) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58503206
AUTHORITY Government Departments
TENDER VALUE 1.44 Lakhs
LAST DATE 23-11-2026
Authority
Authority Name Local Self Government Department
Work Description Tender for Annual Plan-Electrification Of Center No 120 Karikunnu Anganwadi Building - Kuruva Gp-Proj No : S0187/27-General Electrical Work
Basic Detail
Tender No AE/LIDEW/KUR/TER/ET/06/26-27
Bidding Type Tender
Location
City Malappuram
State Kerala
Key Dates
Publish Date 12 Nov 2026
Submission Date 23 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 1.44 Lakhs
Tender Fee 555
EMD 3616
Exemption Available
Document List
490473d8-c0d4-45be-aa27-35160df5aabc.html
BOQ_1515829.xls
E187.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

490473d8-c0d4-45be-aa27-35160df5aabc.html

xls

BOQ_1515829.xls

rar

E187.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender