Tender For State Plan-State Plan 2026-27-Optimisation Of Production And Transmission -Rwss To Kareepra-Supplying And Fixing Of 1 No 75 Hp And 2Nos 60 Hp Soft Starters With All Accessories And Connected Works At Kareepra Wtp-Supplying And Fixing Of 1
Tender Overview
Project Description
Tender for State Plan-State Plan 2026-27-Optimisation Of Production And Transmission -Rwss To Kareepra-Supplying And Fixing Of 1 No 75 Hp And 2Nos 60 Hp Soft Starters With All Accessories And Connected Works At Kareepra Wtp-Supplying And Fixing Of 1 No 75 Hp And 2Nos 60Hp Soft Starters With Accessorres And Connected Work Such As Cable Laying, Wiring, Fixing Etc.-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Automation Soft Starter |
| 2 | OD340187/2025-2026:Supply, erection, testing and commissioning of Three phase, 415 Volt and 50 Hz electronic fully automatic soft starter suitable for 75HP CF motor with over voltage and under voltage protection main conductor and by pass conductor as per IE rules, controller base with protection against Overload, Single Phasing, Phase reversal, phase imbalance capable for use up to 75 HP CF motor pump set Conforms to lSllEC 60947-4-1 & IEC 60947-4-1 with features of Auto Restart, Vibration proof enclosure with lP54 protection class, ON/OFF, Voltage and Ampere indication etc. complete. Disamtling the existing oil immersed starter and stacking the material as per the direction of the Engineer - in- Charge. |
| 3 | OD340188/2025-2026:Supply, erection, testing and commissioning of Three phase, 415 Volt and 50 Hz electronic fully automatic soft starter suitable for 60HP CF motor with over voltage and under voltage protection main conductor and by pass conductor as per IE rules, controller base with protection against Overload, Single Phasing, Phase reversal, phase imbalance capable for use up to 60 HP VT motor pump set Conforms to lSllEC 60947-4-1 & IEC 60947-4-1 with features of Auto Restart, Vibration proof enclosure with lP54 protection class, ON/OFF, Voltage and Ampere indication etc. complete. Disamtling the existing oil immersed starter and stacking the material as per the direction of the Engineer - in- Charge. |
| 4 | OD340189/2025-2026:Dismantling charges for 1 No. 75HP starter and 2 Nos. 60HP starter and connected works |
| 5 | OD340190/2025-2026:Supply and Laying of one number PVC insulated and PVC sheathed / XLPE powercable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipeas required 3.5 core 70sqmm |
| 6 | OD340191/2025-2026:Supply and Laying of one number PVC insulated and PVC sheathed / XLPE powercable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipeas required 3.5 core 75sqmm |
| 7 | OD340192/2025-2026:Rewiring for Kareepra Water Treatment Plant with switch board, switches, PVC insulated copper wires, switchboard, Boxes etc, and Fans, LED lights etc. including Hire and Conveyance charge of tools.RCCB,Removingthe existing damaged wiring with switch board in each room disposalof unserviceable surplus material and stacking of serviceablematerial as directed by officials,8 Nos, MCB,Supplying and fixing 100amps/suitable rating, 240/415 volt, 16 way Distribution Box,Supplyand wiring points according to IS 732-1989 using rigid PVC conduit ofminimum size20 mm withspecials conforming to IS 9537 part III 1983 and with suitable sizespecials conforming to IS 3419-1988, fixing the conduit using metalsaddles spacing not exceeding 50 cm or concealed suitably and with1.00 sq mm FRLS PVC insulated stranded single core copper conductorcable 650V grade, including providing switch board main andcontinuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etccomplete with suitable size modular type metal switch boxes, modulartype front plates (white)etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc.complete. All the terminations in the switch boards and DB-17Nos, Supply and wiring points according to IS 732-1989 using rigid PVCconduit of minimum size 20 mm with specials conforming to IS 9537part III 1983 and with suitable size specials conforming to IS3419-1988, fixing the conduit using metal saddles spacing notexceeding 50 cm or concealed suitably and with 2.5 sq mm FRLS PVCinsulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing withNo.14 SWG bare copper, required quantity of copper earth socket,brass bolt and nut crimping/ soldering etc complete with suitablesize modular type metal switch boxes, modular type front plates(white) etc. up to and including 16A modular type SP switches andmaking good the surface of wall, colour washing etc. complete. Allthe terminations in the switch boards and DB-2Nos,Supplyingand fixing 150 mm X 75 mm X 60 mm metal box on surface or in recesswith suitable size of phenolic laminated sheet cover in frontincluding painting etc -3nos.Supplying and fixing 180 mm X 100 mm X60 mm metal box on surface or in recess with suitable size ofphenolic laminated sheet cover in front including painting etc asrequired.- 2Nos,Supplying and fixing 200 mm X 150 mm X 60 mm metalbox on surface or in recess with suitable size of phenolic laminatedsheet cover in front including painting etc asrequired.-2nos,Supplyingand fixing 200mm X 300mmx 60 metal box on surface or in recess withsuitable size of phenolic laminated sheet cover in front includingpainting etc as required.-1Nos.Supply and Fixing of KWA approved makeoutdoor type 40W LED light having Waterproof IP65 Full PolycarbonateBody-2 nos,Supply conveyance, installation, testing and commissioningthe light fittings of following types made from CRCA sheet 0.5mmthickness with all accessories and lamps directly on wall and givingconnections with 16/0.20 mm 3 core PVC insulated and sheathed roundcopper conductor flex wire or extending the original wiring andgiving connections as required 1200 mm 1X20W LED Lamp with box typefixture Supply, conveyance, installation, testing and commissioningof ceiling fans of the following sizes using standard accessoriesexcluding resistance type regulator, wiring the down rod with16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core roundcopper conductor flex wire or with extended original wiring etc. asrequired. 90.4.5.2 1200mm sweep -5star rated ceiling fan completewith 300mm down rod , canopies, shackeles and blades and resistancetype regulator working on 230V/240V single phase A/C-1Nos,Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with1.5 sq. mm FRLS PVC insulated, copper conductor, single core cableetc. as required.- 1Nos,Supply and fixing 9 W LED bulb on wall /ceiling including giving connections with required length of16/0.20mm PVC insulated and PVC sheathed 3 core round copperconductor flex wire conforming to relevant ISS or extending theoriginal wiring and making good the surface as required.-10Nos,Supply and Fixing of KWA approved make outdoor type 40WLED light having Waterproof IP65 Full Polycarbonate Body-5nos,Supplying and fixing stepped type electronic fan regulator onthe existing modular plate switch box including connections butexcluding modular plate etc. as required.- 2 Nos,Supplying and fixingbrass batten/ angle holder including connection etc. as required.-10Nos,Tools & Plants Hire and Conveyance charge. And connectedwork for the satisfactory completion of work as per the direction ofdepartmental officers |
| 8 | OD29992/2026-2027:Supplying CI Sluice valve including IR sheets , nuts and bolts conforming to BIS specification for 150 mm size quality as per IS 14846/2000 as amendment from time to time. |
| 9 | OD341494/2025-2026:Supplying and fixing of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.0, Size 150mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline