Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - In The Area Of Eutd-1 2 Aligarh; Electrical System Or Installation; On Semi Turnkey Basis - Shifting Of 11 Kv & L.T. Lines , Safe Carriage Of Follow
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - In The Area Of Eutd-1 2 Aligarh; Electrical System Or Installation; On Semi Turnkey Basis - Shifting Of 11 Kv & L.T. Lines , Safe Carriage Of Following Materials From Store Centre Or Any Other Place To The Respective Site Of Work Through The Kachha/Pacca Road Including Loading, Unloading At The Respective Ends And Erection Of Same Including The Work Of Dragging As Per Site Requirement, Jumphering Of Transformer With 11 Kv Line Through Lt Abc Cable, Weasal Conductor Etc. Cost Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work As Per Respo Norms Is Included In The Work. , 11Kv Xlpe Cable 3X185 Mm2 (For Road Crossing) , Lt Abc (3X120+1X70+1X16) Sqmm , St Pole 11 Meter (For Make Double Pole) , St Pole 9 Meter , 11Kv Disk Insulator With Fitting , Earthing Complete , Acsr Dog Conductor , Lt Xlpe Cable 3.5X400mm2 , Lt Xlpe Cable 3.5X240mm2 , Lt Xlpe Cable 1X120mm2 , V-Type Cross Arm , Stay Set , Lt Distribution Box 3 Phase With Clamp , Cable Jointing Kit 3X185sq.Mm. Outdoor Type , 11Kv Pin Insulator With Pin , 11Kv Tpmo Set , 11Kv Do Fuse Set , Supply, Fixing And Erection Of Following Materials As Per Site Requirement As Per Respo Norms:- , Stone Pad , Cross Braccing Angle , Nut Bolt & Washer , Barbed Wire , Danger Board , Pg Clamp , Number Plate , Aluminium Paint , Rex Oxide Paint , Top Channel , Dropper Channel , Dp Holding Clamp , T/F Base Channel , Alumunium Lug 400Mmsq , Alumunium Lug 240Mmsq , Alumunium Lug 120Mmsq , T-Off Channel , Pg Clamp , F-Bracket , Winding Wire 6 Swg , Suspension Clamp With Eye Hook , Lt Piercing Connector For 120/50Mm , Dead End Clamp With Eye Hook , Concreting Of Support , Concreting Of Stay , Neutral & Body Earthing Of Distribution Transformer By Digging Of Pit Upto Water Level And Then Inserting 1-¼ Dia Gi Pipe Of ‘A Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Transformer Body Through Gi Strip Of Size 40X6 Mm With The Help Of Nut And Bolt Or Through Gas Welding, As Per Direction Of Supervising Engineer. It Includes The Cost Of All Material Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. The Aforesaid Work Shall Be Carried Out As Per Resspo Norms. , Construction Of Plinth At Various 11/0.4 Kv Sub-Station Suitable For Distribution Transformer Having Size 2X2x1.5 Mtr. Work Will Include Digging Of Foundation 2 Deep & Brick Work With Ist Class Bricks Having Cement And Sand Mortar Of Ratio 1:6 On All The Walls, Each Of 9 Thickness. The Area Inside The Wall Shall Be Duly Filled By Mud Up To The Height Of Appropriate Level From Ground Level And Shall Be Duly Watered & Rammed. Above The Filling C.C. Of Ration 1:6:12 (Cement Sand And Brick Ballast) Giving 4 Layer Shall Be Provided. Above C.C. Layer Rcc Layer Having 4 Thickness And With Ratio 1:2:4 Of Cement Sand And Stone Ballast Shall Be Provided Re-Enforcement Shall Be Provided By Providing Net Of (8 Nos. + 8 Nos.) M.S. Rods Of Size 10 Mm Dia And Each Of 2M Length In The Middle Of The Top Of C.C. Layer. The Plinth Shall Be Plastered With 12Mm Thick Plaster In Ratio 1:4 At All Sides. This Work Will Include Cost Of Labour, T&P And All Material Required For Construction Of Plinth Which Shall Be Provided By The Contractor As Per Resspo Norms. , Providing And Fixing Of Welded Wire Mesh Fencing Around Transformer Plinth With M.S. Angle Of Size 35X35x6 Mm. Length And 1.20 Meters Height, Such Panels Shall Be Supported On M.S. Angle From Of Size 40X40x6 Mm. Having 04 Nos. Corner Supports Of Height 1.65 Meters Including Extended Legs For Grouting Which Will Be Used As A Door For Entry Of The Personnel Or Removal/Shifting Of Transformer With Welded Hinges, Sliding Belt Etc. For Locking The Arrangement As Per Drawing And Specifications The Fencing Will Be Painted One Coat Of Red Oxide Primer And Then Two Coats Of Bus Green Synthetic Enamel Paint. The Rates Should Be Inclusive Of All Materials Required For Proper Completion Of Above Work (Length Of Each Fencing Approx. 11 Meters) , Supply, Fixing And Erection Of Following Materials As Per Site Requirement As Per Respo Norms:- , 11Mtr S.T. Pole (Scrap) (17+13 = 30 X175kg/Pole) , Weasel Conductor (Scrap) (540Mtr. X 0.109Kg/Meter) , Dog Conductor (Scrap) (2000Mtr. X 0.335Kg/Meter) , Other Line Material Scrap Such As Cross Arm, Clamp, Angle, Channel, Pin Etc. (17+13=30No. /8Kg/Pole) , 9Mtr. S.T. Pole Scrap (10No. X 123Kg/Pole) , L.T. Ab Cable Scrap (440+50 = 490 X 1.17X 0.8 = 459Kg) , Shifting Of 33 Kv Lines , Safe Carriage Of Following Materials From Store Centre Or Any Other Place To The Respective Site Of Work Through The Kachha/Pacca Road Including Loading, Unloading At The Respective Ends And Erection Of Same Including The Work Of Dragging As Per Site Requirement, Jumphering Through Xlpecable, Weasal Conductor Etc. Cost Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work As Per Respo Norms Is Included In The Work. , St Pole 13 Meter (For Make Single Support / Double Pole) , 33Kv Disc Insulator 70Kn , 33Kv Disc Fitting , 33Kv Pin Insulator , 33Kv Pin With Nut , Earthing Complete , 33Kv V-Type Steel Cross Arm , Stay Set , Acsr Dog Conductor , Supply, Fixing And Erection Of Following Materials As Per Site Requirement As Per Respo Norms:- , G.I. Angle Iron 65X65x6mm. 4300Mm Long Bracing With 04 No. Clamps , G.I. Top Channel (125X65x6mm. 3200Mm Long) , Stone Pad 300X300x75mm. , Clmap With Bolt, Nut & Washer , Number Plate , Danger Board , Gi Barbed Wire , Aluminum Tape , Aluminum Paint , Nut , Bolt & Washer , Red Oxide Paint , Guarding Angle (For Guarding Of 33 Kv Lines) , Guarding Clamp , Gi Wire 8Swg , Gi Wire 6Swg , Concreting Of Support , Concreting Of Stay , Supply, Fixing And Erection Of Following Materials As Per Site Requirement As Per Respo Norms:- , Dog Conductor Scrap (8500 Mtr.) , 13 Mtr. S.T. Pole Scrap (40 No.) , Iron Scrap 102 No.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | SHIFTING OF 11 KV & L.T. LINES | SHIFTING OF 11 KV & L.T. LINES |
| 2 | Safe carriage of following materials from Store centre or any other place to the respective site of work through the Kachha/Pacca road including loading, unloading at the respective ends and erection of same including the work of dragging as per site requirement, jumphering of Transformer with 11 KV line through LT ABC cable, Weasal conductor etc. Cost of labour, T&P carrier etc. required for proper completion of work as per RESPO Norms is included in the work. | Safe carriage of following materials from Store centre or any other place to the respective site of work through the Kachha/Pacca road including loading, unloading at the respective ends and erection of same including the work of dragging as per site requirement, jumphering of Transformer with 11 KV line through LT ABC cable, Weasal conductor etc. Cost of labour, T&P carrier etc. required for proper completion of work as per RESPO Norms is included in the work. |
| 3 | 11KV XLPE cable 3x185 mm2 (For Road Crossing) | 11KV XLPE cable 3x185 mm2 (For Road Crossing) |
| 4 | LT ABC (3X120+1X70+1X16) SQMM | LT ABC (3X120+1X70+1X16) SQMM |
| 5 | ST Pole 11 Meter (For Make Double Pole) | ST Pole 11 Meter (For Make Double Pole) |
| 6 | ST Pole 9 METER | ST Pole 9 METER |
| 7 | 11KV DISK INSULATOR WITH FITTING | 11KV DISK INSULATOR WITH FITTING |
| 8 | Earthing Complete | Earthing Complete |
| 9 | ACSR Dog Conductor | ACSR Dog Conductor |
| 10 | LT XLPE Cable 3.5x400mm2 | LT XLPE Cable 3.5x400mm2 |
| 11 | LT XLPE Cable 3.5x240mm2 | LT XLPE Cable 3.5x240mm2 |
| 12 | LT XLPE Cable 1x120mm2 | LT XLPE Cable 1x120mm2 |
| 13 | V-TYPE CROSS ARM | V-TYPE CROSS ARM |
| 14 | Stay Set | Stay Set |
| 15 | LT DISTRIBUTION BOX 3 PHASE WITH CLAMP | LT DISTRIBUTION BOX 3 PHASE WITH CLAMP |
| 16 | Cable Jointing Kit 3x185sq.mm. Outdoor type | Cable Jointing Kit 3x185sq.mm. Outdoor type |
| 17 | 11KV PIN INSULATOR WITH PIN | 11KV PIN INSULATOR WITH PIN |
| 18 | 11KV TPMO SET | 11KV TPMO SET |
| 19 | 11KV DO FUSE SET | 11KV DO FUSE SET |
| 20 | Supply, fixing and erection of following materials as per site requirement as per RESPO Norms:- | Supply, fixing and erection of following materials as per site requirement as per RESPO Norms:- |
| 21 | STONE PAD | STONE PAD |
| 22 | Cross Braccing Angle | Cross Braccing Angle |
| 23 | Nut Bolt & Washer | Nut Bolt & Washer |
| 24 | Barbed wire | Barbed wire |
| 25 | Danger Board | Danger Board |
| 26 | PG Clamp | PG Clamp |
| 27 | Number Plate | Number Plate |
| 28 | Aluminium Paint | Aluminium Paint |
| 29 | Rex Oxide Paint | Rex Oxide Paint |
| 30 | Top Channel | Top Channel |
| 31 | Dropper Channel | Dropper Channel |
| 32 | DP HOLDING CLAMP | DP HOLDING CLAMP |
| 33 | T/F BASE CHANNEL | T/F BASE CHANNEL |
| 34 | Alumunium Lug 400MMSQ | Alumunium Lug 400MMSQ |
| 35 | Alumunium Lug 240MMSQ | Alumunium Lug 240MMSQ |
| 36 | Alumunium Lug 120MMSQ | Alumunium Lug 120MMSQ |
| 37 | T-OFF CHANNEL | T-OFF CHANNEL |
| 38 | PG CLAMP | PG CLAMP |
| 39 | F-BRACKET | F-BRACKET |
| 40 | WINDING WIRE 6 SWG | WINDING WIRE 6 SWG |
| 41 | SUSPENSION CLAMP WITH EYE HOOK | SUSPENSION CLAMP WITH EYE HOOK |
| 42 | LT PIERCING CONNECTOR FOR 120/50MM | LT PIERCING CONNECTOR FOR 120/50MM |
| 43 | DEAD END CLAMP WITH EYE HOOK | DEAD END CLAMP WITH EYE HOOK |
| 44 | Concreting of Support | Concreting of Support |
| 45 | Concreting of Stay | Concreting of Stay |
| 46 | Neutral & body earthing of Distribution Transformer by digging of pit upto water level and then inserting 1-¼” dia GI pipe of ‘A’ grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 40x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer. It includes the cost of all material labour, T&P, carrier etc. required for proper completion of work. The aforesaid work shall be carried out as per RESSPO norms. | Neutral & body earthing of Distribution Transformer by digging of pit upto water level and then inserting 1-¼” dia GI pipe of ‘A’ grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 40x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer. It includes the cost of all material labour, T&P, carrier etc. required for proper completion of work. The aforesaid work shall be carried out as per RESSPO norms. |
| 47 | Construction of plinth at various 11/0.4 KV Sub-station suitable for distribution transformer having size 2x2x1.5 Mtr. Work will include digging of foundation 2’ deep & brick work with Ist class bricks having cement and sand mortar of ratio 1:6 on all the walls, each of 9” thickness. The area inside the wall shall be duly filled by mud up to the height of appropriate level from ground level and shall be duly watered & rammed. Above the filling C.C. of ration 1:6:12 (Cement sand and brick ballast) giving 4” layer shall be provided. Above C.C. layer RCC layer having 4” thickness and with ratio 1:2:4 of cement sand and stone ballast shall be provided Re-enforcement shall be provided by providing net of (8 Nos. + 8 Nos.) M.S. rods of size 10 mm dia and each of 2M length in the middle of the top of C.C. layer. The plinth shall be plastered with 12mm thick plaster in ratio 1:4 at all sides. This work will include cost of labour, T&P and all material required for construction of plinth which shall be provided by the contractor as per RESSPO Norms. | Construction of plinth at various 11/0.4 KV Sub-station suitable for distribution transformer having size 2x2x1.5 Mtr. Work will include digging of foundation 2’ deep & brick work with Ist class bricks having cement and sand mortar of ratio 1:6 on all the walls, each of 9” thickness. The area inside the wall shall be duly filled by mud up to the height of appropriate level from ground level and shall be duly watered & rammed. Above the filling C.C. of ration 1:6:12 (Cement sand and brick ballast) giving 4” layer shall be provided. Above C.C. layer RCC layer having 4” thickness and with ratio 1:2:4 of cement sand and stone ballast shall be provided Re-enforcement shall be provided by providing net of (8 Nos. + 8 Nos.) M.S. rods of size 10 mm dia and each of 2M length in the middle of the top of C.C. layer. The plinth shall be plastered with 12mm thick plaster in ratio 1:4 at all sides. This work will include cost of labour, T&P and all material required for construction of plinth which shall be provided by the contractor as per RESSPO Norms. |
| 48 | Providing and fixing of welded wire mesh fencing around transformer plinth with M.S. Angle of size 35X35X6 mm. length and 1.20 Meters height, such panels shall be supported on M.S. Angle from of size 40X40X6 mm. having 04 Nos. corner supports of height 1.65 Meters including extended legs for grouting which will be used as a door for entry of the personnel or removal/shifting of transformer with welded hinges, sliding belt etc. for locking the arrangement as per drawing and specifications the fencing will be painted one coat of red oxide primer and then two coats of bus green synthetic enamel paint. The rates should be inclusive of all materials required for proper completion of above work (length of each fencing approx. 11 Meters) | Providing and fixing of welded wire mesh fencing around transformer plinth with M.S. Angle of size 35X35X6 mm. length and 1.20 Meters height, such panels shall be supported on M.S. Angle from of size 40X40X6 mm. having 04 Nos. corner supports of height 1.65 Meters including extended legs for grouting which will be used as a door for entry of the personnel or removal/shifting of transformer with welded hinges, sliding belt etc. for locking the arrangement as per drawing and specifications the fencing will be painted one coat of red oxide primer and then two coats of bus green synthetic enamel paint. The rates should be inclusive of all materials required for proper completion of above work (length of each fencing approx. 11 Meters) |
| 49 | Supply, fixing and erection of following materials as per site requirement as per RESPO Norms:- | Supply, fixing and erection of following materials as per site requirement as per RESPO Norms:- |
| 50 | 11Mtr S.T. Pole (Scrap) (17+13 = 30 x175KG/Pole) | 11Mtr S.T. Pole (Scrap) (17+13 = 30 x175KG/Pole) |
| 51 | Weasel Conductor (Scrap) (540Mtr. X 0.109KG/Meter) | Weasel Conductor (Scrap) (540Mtr. X 0.109KG/Meter) |
| 52 | Dog Conductor (Scrap) (2000Mtr. X 0.335KG/Meter) | Dog Conductor (Scrap) (2000Mtr. X 0.335KG/Meter) |
| 53 | Other Line Material scrap such as Cross Arm, Clamp, Angle, Channel, Pin etc. (17+13=30No. /8KG/Pole) | Other Line Material scrap such as Cross Arm, Clamp, Angle, Channel, Pin etc. (17+13=30No. /8KG/Pole) |
| 54 | 9Mtr. S.T. Pole Scrap (10No. X 123KG/Pole) | 9Mtr. S.T. Pole Scrap (10No. X 123KG/Pole) |
| 55 | L.T. AB Cable scrap (440+50 = 490 x 1.17x 0.8 = 459KG) | L.T. AB Cable scrap (440+50 = 490 x 1.17x 0.8 = 459KG) |
| 56 | SHIFTING OF 33 kV LINES | SHIFTING OF 33 kV LINES |
| 57 | Safe carriage of following materials from Store centre or any other place to the respective site of work through the Kachha/Pacca road including loading, unloading at the respective ends and erection of same including the work of dragging as per site requirement, jumphering through XLPEcable, Weasal conductor etc. Cost of labour, T&P carrier etc. required for proper completion of work as per RESPO Norms is included in the work. | Safe carriage of following materials from Store centre or any other place to the respective site of work through the Kachha/Pacca road including loading, unloading at the respective ends and erection of same including the work of dragging as per site requirement, jumphering through XLPEcable, Weasal conductor etc. Cost of labour, T&P carrier etc. required for proper completion of work as per RESPO Norms is included in the work. |
| 58 | ST Pole 13 Meter (For Make Single Support / Double Pole) | ST Pole 13 Meter (For Make Single Support / Double Pole) |
| 59 | 33KV Disc Insulator 70KN | 33KV Disc Insulator 70KN |
| 60 | 33KV Disc Fitting | 33KV Disc Fitting |
| 61 | 33KV Pin Insulator | 33KV Pin Insulator |
| 62 | 33KV Pin with Nut | 33KV Pin with Nut |
| 63 | Earthing Complete | Earthing Complete |
| 64 | 33KV V-type Steel Cross Arm | 33KV V-type Steel Cross Arm |
| 65 | Stay Set | Stay Set |
| 66 | ACSR Dog Conductor | ACSR Dog Conductor |
| 67 | Supply, fixing and erection of following materials as per site requirement as per RESPO Norms:- | Supply, fixing and erection of following materials as per site requirement as per RESPO Norms:- |
| 68 | G.I. Angle Iron 65x65x6mm. 4300mm Long Bracing with 04 No. Clamps | G.I. Angle Iron 65x65x6mm. 4300mm Long Bracing with 04 No. Clamps |
| 69 | G.I. Top Channel (125x65x6mm. 3200mm Long) | G.I. Top Channel (125x65x6mm. 3200mm Long) |
| 70 | Stone Pad 300x300x75mm. | Stone Pad 300x300x75mm. |
| 71 | Clmap with bolt, nut & washer | Clmap with bolt, nut & washer |
| 72 | Number Plate | Number Plate |
| 73 | Danger Board | Danger Board |
| 74 | GI Barbed Wire | GI Barbed Wire |
| 75 | Aluminum Tape | Aluminum Tape |
| 76 | Aluminum Paint | Aluminum Paint |
| 77 | Nut , Bolt & Washer | Nut , Bolt & Washer |
| 78 | Red Oxide Paint | Red Oxide Paint |
| 79 | Guarding Angle (for Guarding of 33 Kv Lines) | Guarding Angle (for Guarding of 33 Kv Lines) |
| 80 | Guarding Clamp | Guarding Clamp |
| 81 | GI Wire 8SWG | GI Wire 8SWG |
| 82 | GI Wire 6SWG | GI Wire 6SWG |
| 83 | Concreting of Support | Concreting of Support |
| 84 | Concreting of Stay | Concreting of Stay |
| 85 | Supply, fixing and erection of following materials as per site requirement as per RESPO Norms:- | Supply, fixing and erection of following materials as per site requirement as per RESPO Norms:- |
| 86 | Dog Conductor Scrap (8500 Mtr.) | Dog Conductor Scrap (8500 Mtr.) |
| 87 | 13 Mtr. S.T. Pole Scrap (40 No.) | 13 Mtr. S.T. Pole Scrap (40 No.) |
| 88 | Iron Scrap 102 No. | Iron Scrap 102 No. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender