New and Renewable Energy Government Departments Closing in 18 days TDR #58500595

Bids Are invited for Sitc Of Meteorological Equipment At Mbrapp Site

Issued by Government Departments · Banswara, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Dec 2026
18 days left
EMD
65694
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Banswara → Rajasthan
EMD Exemption
Not Available
Quantity
352

Project Description

Bids Are invited for Wind Speed And Wind Direction Sensors At 10M 20M And 30M Height From Ground Level - Refer Technical Specification Table-A Sn 1 And 2 , Temperature Sensors At 1.2M 10M 20M And 30M Height From Ground Level. - Refer Technical Specification Table-A Sn 3 , Solar Radiation At 1.2M Height - Refer Technical Specification Table-A Sn 4 , Net Radiation At 1.2M Height - Refer Technical Specification Table-A Sn 5 , Humidity At 1.2M Height - Refer Technical Specification Table-A Sn 6 , Atmospheric Pressure At 1.2M Height From Ground Level. - Refer Technical Specification Table-A Sn 7 , Rain Gauge Sensor At Ground Level - Refer Technical Specification Table-A Sn 8 , Datalogger - Refer Technical Specification Table-A Sn 9 , Wind Speed And Wind Direction Sensors At 10M And 30M Height From Ground Level. - Refer Technical Specification Table-B Sn 1 And 2 , Temperature At 1.2M,10M, 30M Height From Ground Level. - Refer Technical Specification Table-B Sn 3 , Solar Radiation At 1.2M Height - Refer Technical Specification Table-B Sn 4 , Net Radiation At 1.2M Height - Refer Technical Specification Table-B Sn 5 , Humidity Sensor At 1.2M Height - Refer Technical Specification Table-B Sn 6 , Atmospheric Pressure At 1.2M Height From Ground Level. - Refer Technical Specification Table-B Sn 7 , Rain Gauge Sensor At Ground Level - Refer Technical Specification Table-B Sn 8 , Evaporation Meter - Refer Technical Specification Table-B Sn 9 , Datalogger - Refer Technical Specification Table-B Sn 10 , Portable Manual Temperature And Relative Humidity Sensor - Refer Technical Specification Table-C , Server - Refer Technical Specification Sn 6 , Software - Refer Technical Specification Table-B Sn 15 , Cat6 Lan Cable Roll - Cat6 Lan Cable , Spd Type -2 - Surge Protection Device Type -2 , Ac To Dc Converter - 230 V Ac To Dc (9-32 Volt) , Installation ,Testing And Commisioning Of All Above Mentioned Equipments

BOQ

Sl. No. Item TitleItem Description
1Wind speed and Wind direction sensors at 10m 20m and 30m height from ground levelRefer technical specification TABLE-A SN 1 and 2
2Temperature sensors at 1.2m 10m 20m and 30m height from ground level.Refer technical specification TABLE-A SN 3
3Solar radiation at 1.2m heightRefer technical specification TABLE-A SN 4
4Net radiation at 1.2m heightRefer technical specification TABLE-A SN 5
5Humidity at 1.2m heightRefer technical specification TABLE-A SN 6
6Atmospheric Pressure at 1.2m height from ground level.Refer technical specification TABLE-A SN 7
7Rain gauge sensor at ground levelRefer technical specification TABLE-A SN 8
8DataloggerRefer technical specification TABLE-A SN 9
9Wind speed and Wind Direction sensors at 10m and 30m height from ground level.Refer technical specification TABLE-B SN 1 and 2
10Temperature at 1.2m,10m, 30m height from ground level.Refer technical specification TABLE-B SN 3
11Solar radiation at 1.2m heightRefer technical specification TABLE-B SN 4
12Net radiation at 1.2m heightRefer technical specification TABLE-B SN 5
13Humidity sensor at 1.2m heightRefer technical specification TABLE-B SN 6
14Atmospheric Pressure at 1.2m height from ground level.Refer technical specification TABLE-B SN 7
15Rain gauge sensor at ground levelRefer technical specification TABLE-B SN 8
16Evaporation meterRefer technical specification TABLE-B SN 9
17DataloggerRefer technical specification TABLE-B SN 10
18Portable manual temperature and relative humidity sensorRefer technical specification TABLE-C
19ServerRefer technical specification SN 6
20SoftwareRefer technical specification Table-B SN 15
21CAT6 LAN cable RollCAT6 LAN cable
22SPD Type -2Surge protection device type -2
23AC TO DC Converter230 V AC to DC (9-32 volt)
24Installation ,Testing and Commisioning of all above mentioned equipmentsInstallation ,Testing and Commisioning of all above mentioned equipments

AI Tender Summary

OUR REF NO 58500595
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 03-12-2026
Authority
Authority Name Department Of Atomic Energy
Work Description Bids Are invited for Wind Speed And Wind Direction Sensors At 10M 20M And 30M Height From Ground Level - Refer Technical Specification Table-A Sn 1 And 2 , Temperature Sensors At 1.2M 10M 20M And 30M Height From Ground Level. - Refer Technical Specification Table-A Sn 3 , Solar Radiation At 1.2M Height - Refer Technical Specification Table-A Sn 4 , Net Radiation At 1.2M Height - Refer Technical Specification Table-A Sn 5 , Humidity At 1.2M Height - Refer Technical Specification Table-A Sn 6 , Atmospheric Pressure At 1.2M Height From Ground Level. - Refer Technical Specification Table-A Sn 7 , Rain Gauge Sensor At Ground Level - Refer Technical Specification Table-A Sn 8 , Datalogger - Refer Technical Specification Table-A Sn 9 , Wind Speed And Wind Direction Sensors At 10M And 30M Height From Ground Level. - Refer Technical Specification Table-B Sn 1 And 2 , Temperature At 1.2M,10M, 30M Height From Ground Level. - Refer Technical Specification Table-B Sn 3 , Solar Radiation At 1.2M Height - Refer Technical Specification Table-B Sn 4 , Net Radiation At 1.2M Height - Refer Technical Specification Table-B Sn 5 , Humidity Sensor At 1.2M Height - Refer Technical Specification Table-B Sn 6 , Atmospheric Pressure At 1.2M Height From Ground Level. - Refer Technical Specification Table-B Sn 7 , Rain Gauge Sensor At Ground Level - Refer Technical Specification Table-B Sn 8 , Evaporation Meter - Refer Technical Specification Table-B Sn 9 , Datalogger - Refer Technical Specification Table-B Sn 10 , Portable Manual Temperature And Relative Humidity Sensor - Refer Technical Specification Table-C , Server - Refer Technical Specification Sn 6 , Software - Refer Technical Specification Table-B Sn 15 , Cat6 Lan Cable Roll - Cat6 Lan Cable , Spd Type -2 - Surge Protection Device Type -2 , Ac To Dc Converter - 230 V Ac To Dc (9-32 Volt) , Installation ,Testing And Commisioning Of All Above Mentioned Equipments
Basic Detail
Tender No GEM/2026/B/8263305
Bidding Type Tender
Location
City Banswara
State Rajasthan
Key Dates
Publish Date 12 Nov 2026
Submission Date 03 Dec 2026
Open Date 04 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 65694
Exemption Not Available
Document List
bce723b7-b07c-43cf-b639-ab197a54793c.pdf
technical_specification___meterological_instruments_2026-11-11-13-38-00_872ea22de5576a3766d5ecb1107ef75d.pdf
10153479_Boq_1.xlsx
ATC_MET38_81fc8ae5-3122-4de6-86181794481468881_MBBUYER01.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

bce723b7-b07c-43cf-b639-ab197a54793c.pdf

pdf

technical_specification___meterological_instruments_2026-11-11-13-38-00_872ea22de5576a3766d5ecb1107ef75d.pdf

xlsx

10153479_Boq_1.xlsx

pdf

ATC_MET38_81fc8ae5-3122-4de6-86181794481468881_MBBUYER01.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender