Bids Are invited for Supply And Filling Of Joint At Af Station Utarlai
Tender Overview
Project Description
Bids Are invited for M And L For Racking Out Old Existing Sealant Compound Backup Rod And Filler Board Of The Existing Joints Any Description 30Mm To 40Mm Wide By Special Tools Like Racker Cutting Blades As Per Atc , M And L For Racking Out Old Existing Sealant Compound Backup Rod Of The Existing Joints Any Description 20Mm To 30Mm Wide By Special Tools Like Racker Cutting Blades Machines As Per Atc , M And L Cutting For Existing Runway Taxi Track At Cracks And Spelled Edges Upto A Minimum Depth 30Mm By Mechanicals Tools Making Grooves At Cleaning Through Air Blower Air Blasting As Per Atc , M And L For Cleaning Existing Holes Cavities With Broom And Compressed Air Surfaces Area Not Exceeding 3 Sq Cm Each Of Any Shape Filling With Epoxy Resin Mortar Of Make Fosroc As Per Atc , Demolition Scarifying Or Picking Gravelled Macadam Or Bituminous Macadam Surface In Area Exc 400 Sqm And Depth Exc 100 Mm And Not Exc 150 Mm Thick Complete All As Specified And Directed , Earthwork In Excavation In Any Kind Of Soil By Mechanical Means Hydraulic Excavator Means Over Areas Exceeding 30 Cm In Depth 1 Point 50M In Width As Well As 10 Sqm On Plan Incl As Per Atc , M And L For 600 Mm Bore Reinforced Concrete Pipes Class Np 2 With One Collar Per Length Of Pipe Including , M And L For Cement Concrete 1 Ratio 3 Ratio 6 Type C 2 Concrete Bed To Drain Pipes Incl Packing Under And Haunching Against The Sides Of Pipes Of 600Mm Dia After They Are Laid As Per Atc , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 25 Cm Complete All As Specified And Directed , Demolition Of Un Reinforced Cement Concrete In Ground Floor And Paving Not Exceeding 15 Cm Thick Below Or Above Ground Level Complete All As Specified And Directed , M And L 75 Mm Thick Cement Concrete 1 Ratio 4 Ratio 8 Type D2 Using 40Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Or In Sub Base Of Floors Complete All As Directed , M And L For 100 Mm Thick Cement Concrete 1 Ratio 3 Ratio 6 Type C 2 Using 40Mm Graded Stone Aggregate Surfaces Finished Even And Smooth Without Using Extra Cement As In Path Incl As Per Atc , Demolition Of Pcc Block Masonry Built In Cement Mortar Of Any Specification And In Any Position Complete All As Directed , M And L Precast Cement Concrete Block Masonry With Solid Blocks Made Of Pcc 1 Ratio 3 Ratio 6 Type C1 Using 20Mm Graded Stone Aggregate Exc 10Cm In Width And Set In Cm 1 Ratio 6 Complete , M And L For 15Mm Thick Rendering In Cement Mortar 1 Ratio 6 On Stone Pcc Block Masonry Surfaces Finished Even And Smooth Without Using Extra Cement Complete All As Directed , M And L For Rendering 15Mm Thick In Cement Mortar 1 Ratio 4 On Stone Walls Or Concrete Surface Finished Even And Smooth Without Using Extra Cement Mixed With Water Proofing Liquid As Per Atc , Supply Only Integral Water Proofing Compound Complete All As Specified , M And L For Preparation Of Newly Plastered Surfaces Of Walls And Applying Three Coats Of White Wash Complete All As Specified , M And L For Racking Out Old Existing Sealant Compound Backup Rod And Filler Board Of The Existing Joints Any Description 30 Mm To 40Mm Wide By Special Tools Like Racker Cutting Blades As Per Atc , M And L For Racking Out Old Existing Sealant Compound Backup Rod Of The Existing Joints Any Description 20 To 30Mm Wide By Special Tools Like Racker Cutting Blades Machines Widening As Per Atc , M And L Cutting For Existing Runway Taxi Track At Cracks And Spelled Edges Upto A Minimum Depth 30Mm By Mechanicals Tools Making Grooves At Cleaning Through Air Blowerair Blasting As Per Atc , M And L For Cleaning Existing Holes Cavities With Broom And Compressed Air Surfaces Area Not Exceeding 3 Sq Cm Each Of Any Shape And Filling With Epoxy Resin Mortar Of Make Fosroc As Per Atc
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | M and L for racking out old existing sealant compound backup rod and filler board of the existing joints any description 30mm to 40mm wide by special tools like racker cutting blades as per ATC | M and L for racking out old existing sealant compound backup rod and filler board of the existing joints any description 30mm to 40mm wide by special tools like racker cutting blades as per ATC |
| 2 | M and L for racking out old existing sealant compound backup rod of the existing joints any description 20mm to 30mm wide by special tools like racker cutting blades machines as per ATC | M and L for racking out old existing sealant compound backup rod of the existing joints any description 20mm to 30mm wide by special tools like racker cutting blades machines as per ATC |
| 3 | M and L cutting for existing runway taxi track at cracks and spelled edges upto a minimum depth 30mm by mechanicals tools making grooves at cleaning through air blower air blasting as per ATC | M and L cutting for existing runway taxi track at cracks and spelled edges upto a minimum depth 30mm by mechanicals tools making grooves at cleaning through air blower air blasting as per ATC |
| 4 | M and L for cleaning existing holes cavities with broom and compressed air surfaces area not exceeding 3 Sq Cm each of any shape filling with epoxy resin mortar of make Fosroc as per ATC | M and L for cleaning existing holes cavities with broom and compressed air surfaces area not exceeding 3 Sq Cm each of any shape filling with epoxy resin mortar of make Fosroc as per ATC |
| 5 | Demolition Scarifying or picking gravelled macadam or bituminous macadam surface in area exc 400 Sqm and depth exc 100 mm and not exc 150 mm thick complete all as specified and directed | Demolition Scarifying or picking gravelled macadam or bituminous macadam surface in area exc 400 Sqm and depth exc 100 mm and not exc 150 mm thick complete all as specified and directed |
| 6 | Earthwork in excavation in any kind of soil by mechanical means Hydraulic excavator means over areas exceeding 30 cm in depth 1 point 50m in width as well as 10 sqm on plan incl as per ATC | Earthwork in excavation in any kind of soil by mechanical means Hydraulic excavator means over areas exceeding 30 cm in depth 1 point 50m in width as well as 10 sqm on plan incl as per ATC |
| 7 | M and L for 600 mm bore reinforced concrete pipes class NP 2 with one collar per length of pipe including | M and L for 600 mm bore reinforced concrete pipes class NP 2 with one collar per length of pipe including |
| 8 | M and L for Cement concrete 1 ratio 3 ratio 6 Type C 2 Concrete bed to drain pipes incl packing under and haunching against the sides of pipes of 600mm dia after they are laid as per ATC | M and L for Cement concrete 1 ratio 3 ratio 6 Type C 2 Concrete bed to drain pipes incl packing under and haunching against the sides of pipes of 600mm dia after they are laid as per ATC |
| 9 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed |
| 10 | Demolition of un reinforced cement concrete in ground floor and paving not exceeding 15 cm thick below or above ground level complete all as specified and directed | Demolition of un reinforced cement concrete in ground floor and paving not exceeding 15 cm thick below or above ground level complete all as specified and directed |
| 11 | M and L 75 mm thick cement concrete 1 ratio 4 ratio 8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete or in sub base of floors complete all as directed | M and L 75 mm thick cement concrete 1 ratio 4 ratio 8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete or in sub base of floors complete all as directed |
| 12 | M and L for 100 mm thick Cement concrete 1 ratio 3 ratio 6 type C 2 using 40mm graded stone aggregate surfaces finished even and smooth without using extra cement as in path incl as per ATC | M and L for 100 mm thick Cement concrete 1 ratio 3 ratio 6 type C 2 using 40mm graded stone aggregate surfaces finished even and smooth without using extra cement as in path incl as per ATC |
| 13 | Demolition of PCC block masonry built in cement mortar of any specification and in any position complete all as directed | Demolition of PCC block masonry built in cement mortar of any specification and in any position complete all as directed |
| 14 | M and L precast cement concrete block masonry with solid blocks made of PCC 1 ratio 3 ratio 6 type C1 using 20mm graded stone aggregate exc 10cm in width and set in CM 1 ratio 6 complete | M and L precast cement concrete block masonry with solid blocks made of PCC 1 ratio 3 ratio 6 type C1 using 20mm graded stone aggregate exc 10cm in width and set in CM 1 ratio 6 complete |
| 15 | M and L for 15mm thick rendering in cement mortar 1 ratio 6 on stone PCC block masonry surfaces finished even and smooth without using extra cement complete all as directed | M and L for 15mm thick rendering in cement mortar 1 ratio 6 on stone PCC block masonry surfaces finished even and smooth without using extra cement complete all as directed |
| 16 | M and L for Rendering 15mm thick in cement mortar 1 ratio 4 on stone walls or concrete surface finished even and smooth without using extra cement mixed with water proofing liquid as per ATC | M and L for Rendering 15mm thick in cement mortar 1 ratio 4 on stone walls or concrete surface finished even and smooth without using extra cement mixed with water proofing liquid as per ATC |
| 17 | Supply only integral water proofing compound complete all as specified | Supply only integral water proofing compound complete all as specified |
| 18 | M and L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified | M and L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified |
| 19 | M and L for racking out old existing sealant compound backup rod and filler board of the existing joints any description 30 mm to 40mm wide by special tools like racker cutting blades as per ATC | M and L for racking out old existing sealant compound backup rod and filler board of the existing joints any description 30 mm to 40mm wide by special tools like racker cutting blades as per ATC |
| 20 | M and L for racking out old existing sealant compound backup rod of the existing joints any description 20 to 30mm wide by special tools like racker cutting blades machines widening as per ATC | M and L for racking out old existing sealant compound backup rod of the existing joints any description 20 to 30mm wide by special tools like racker cutting blades machines widening as per ATC |
| 21 | M and L cutting for existing runway taxi track at cracks and spelled edges upto a minimum depth 30mm by mechanicals tools making grooves at cleaning through air blowerair blasting as per ATC | M and L cutting for existing runway taxi track at cracks and spelled edges upto a minimum depth 30mm by mechanicals tools making grooves at cleaning through air blowerair blasting as per ATC |
| 22 | M and L for cleaning existing holes cavities with broom and compressed air surfaces area not exceeding 3 Sq Cm each of any shape and filling with epoxy resin mortar of make Fosroc as per ATC | M and L for cleaning existing holes cavities with broom and compressed air surfaces area not exceeding 3 Sq Cm each of any shape and filling with epoxy resin mortar of make Fosroc as per ATC |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender