Tender For Repair/ Replacement/ Maintenance Of Rising Main Water Pipe Line, And Other Connected Works At Roorkee Under Ge (Mes) Roorkee.
Tender Value
44.69 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
20 days left
EMD
89380
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement/ Maintenance Of Rising Main Water Pipe Line, And Other Connected Works At Roorkee Under Ge (Mes) Roorkee.
BOQ
| Sl. No. | Item Description |
| 1 | Taking up Cast iron/Mild steel water mains 80 mm bore (including all fittings), with spigot and socket ends and tyton joints/lead joints including burning out joints and recovering lead complete all as specified and directed. |
| 2 | All as per item No 01 here-in-before but 100 mm bore |
| 3 | All as per item No 01 here-in-before but 150 mm bore |
| 4 | All as per item No 01 here-in-before but 150 mm bore flange type |
| 5 | Supply and lay in trenches of Ductile iron pipes 80 mm bore k-7 Spigot and Socketed ends, centrifugally cast suitable for tyton joint in different lengths including rubber tyton joint complete as per site condition all as specified and directed. |
| 6 | All as per item No 05 here-in-before but 100 mm bore k-7 |
| 7 | All as per item No 05 here-in-before but 150 mm Bore K-7 |
| 8 | All as per item No 05 here-in-before but 150 mm Bore K-9 |
| 9 | Supply and laying 150 mm dia Ductile Iron Double Flanged Pipe, Class K-9, complete with all fittings, rubber gaskets, nuts, bolts, jointing, testing and commissioning, complete in all as directed by the Engineer-in-Charge. |
| 10 | M&L for DI Fittings like bends (any type, radius, and angle) tapers any type straight bend, increasing, decreasing or double socket Etc) Tee pieces single branch, Y junction, double branch cross all socket or socket and spigot) collars, cops, upto 150 mm bore of pipe complete all as specified and directed. |
| 11 | M & L for \\"D\\" joints complete with nut bolt & washers etc suitable for sizes of water mains 80 mm bore complete all as specified and directed. |
| 12 | All as per item No 11 here-in-before but 100mm bore |
| 13 | All as per item No 11 here-in-before but 150mm bore |
| 14 | Labour only for cutting of cast iron water mains 80mm bore carefully in repairs for inserting fittings such as bend, tee, socket pieces, collar etc complete all as specified and as directed. |
| 15 | All as per item No 14 here-in-before but 100mm bore |
| 16 | All as per item No 14 here-in-before but 150mm bore |
| 17 | M&L for drilling / boring and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm complete all as specified and direted. |
| 18 | M&L for Straight plain brass ferrules (or connecting screws ) screwed both ends and fixed to CI pipes pipes of size 20 mm bore |
| 19 | Supply & Fix gun metal gate valve 15mm bore in replacement with iron wheel head screwed both end for iron pipe complete all as specified of the following sizes including dismantling the old unserviceable existing valve complete. As per IS-778 Make Lead valve Ltd |
| 20 | All as per item No 19 here-in-before but 20 mm bore |
| 21 | All as per item No 19 here-in-before but 25 mm bore |
| 22 | Taking out unserviceable sluice valve including S & F sluice valve 80 mm bore class PN-1.6, heavy duty, both ends flanged with gun metal spindle & check nut and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes (Note :- for these sluice valves which are fixed with pillar of over head tank work involve such as breaking of PCC/Lead flange joints will be deemed to include in the rate quoted & contractor will also repair the damaged floor etc,to match with existing. ( joints shall be measured & paid for seprately).As per IS-14846 and IS-780 Make- Kilosker, Pneucons, Zoloto. |
| 23 | All as per item No 22 here-in-before but 100 mm bore |
| 24 | All as per item No 22 here-in-before but 150 mm bore |
| 25 | Supply and fix Non return valve 80 mm bore in replaement connecting and testing non return valve horizental flow both and flanged class 'B' as per IS specification and conforming to IS -5312 including flange joints etc incl taking out old u/s valve |
| 26 | All as per item No 25 here-in-before but 100 mm bore |
| 27 | All as per item No 25 here-in-before but 150 mm bore |
| 28 | Excavation in trenches not exc. 1.5mtr wide and not exe 1.5 mtr in depth for laying GI pipe/ CI Pipe etc. and getting out in soft/loose soil complete all as specified and directed. |
| 29 | Returning fillingin soil from excavation including spreading, leveling, watering and well ramming in layers n.exe. 25 cm thick complete all as specified and directed. |
| 30 | Removing excavated (surplus soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 31 | M&L for construction of brick masonry valve chamber in repairs of internal size 1.05 x 1.05x 1.05 Mtr (Internal dimension) with sub class 'B' bricks in CM (1:6) with 3mm thick MS Sheet cover and angle iron frame made out of 40x40x6mm with 2 Nos MS hinges welded to angle iron frame including lifting hook & locking arrangement duly painted with one coat of black bituminous paint over a coat of red oxide primer complete with necessary earth work, brick work, PCC bed, cement plastering, finishing including dismantling and removal of old unserviceble valve pit remains from site complete all as specified and directed.by the Engineer-in-Charge |
| 32 | All as per item no 31 but for 900 mm x 900 mm x 900 mm (Internal dimension) |
| 33 | Cutting of road/dismantling of any interlocking paver blocks from pathways making good as existing disturbed surface for what material or note all rates are included complete all as specified and directed. |
| 34 | M&L for PCC 1:2:4 type B1 using 20 mm stone aggregate for providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string course lacing courses, parapets and railing upto 60cm in height copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as directed. |
| 35 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in complete all as specified and directed |
| 36 | M&L for rendering 10 mm thick on fair face of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 37 | S&F bib taps 15 mm bore, Bib taps, cast iron with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.Make-Huno bib cock, B K jagaran & Co |
| 38 | Taking out steel tubing from from trenches/or from any site all as directed by Engineer-in-Charge 15mm bore complete all as specified and directed (excavation & earth work shall be measured and paid separetly) |
| 39 | All as per item No 38 here-in-before but 20 mm bore |
| 40 | All as per item No 38 here-in-before but 25 mm bore |
| 41 | All as per item No 38 here-in-before but 40 mm bore |
| 42 | All as per item No 38 here-in-before but 50 mm bore |
| 43 | All as per item No 38 here-in-before but 80 mm bore |
| 44 | Supply and laying, jointing and testing GI Pipe medium grade 15mm bore including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches or wall/ceiling/floor as specified and as directed at site of the following sizes :- (Notes : (i) The laying and jointing of pipes are required to be carried out in short streches catering to specific requirements of a purticular quarter, building block or a group of blocks.) |
| 45 | All as per item No 44 here-in-before but 20 mm bore |
| 46 | All as per item No 44 here-in-before but 25 mm bore |
| 47 | All as per item No 44 here-in-before but 40 mm bore |
| 48 | All as per item No 44 here-in-before but 50 mm bore |
| 49 | All as per item No 44 here-in-before but 80 mm bore |
| 50 | Re-laying, jointing old steel tubing 15mm bore after cleaning and connections in new or old position including supply & Fix new fittings such as bends, elbows, union, tees, reducers etc; as required at site laid in trenches or on floors incl taking out complete all as specified and as directed |
| 51 | All as per item No 50 here-in-before but 20 mm bore |
| 52 | All as per item No 44 here-in-before but 25 mm bore |
| 53 | All as per item No 44 here-in-before but 40 mm bore |
| 54 | All as per item No 44 here-in-before but 50 mm bore |
| 55 | Taking out, sluice valve 80 mm dia bore top cover, spindle and broken / unsv check nut (gutka) carry to workshop & re-fixing of sluice valve after servicing / maintenance /grinding / cleaning / threading / greasing work to sluice valve parts, including replacement of gland packing, rubber sheet, nut, bolt, Spindle ,check nut and washer of existing size complete all as specified and directed. |
| 56 | All as per item No 55 here-in-before but 100mm dia bore |
| 57 | All as per item No 55 here-in-before but 150mm dia bore |
| 58 | All as per item No 55 here-in-before but 200 mm dia bore |
| 59 | M&L for repairing leakages of CI pipes 80 mm dia bore with spigot and socket ends, de-watering of pipe lines and trenches, burning out joints to recover lead and making new lead joint with retrieved material and any additional quantity of lead required as per site requirement complete including all other materials such as spun yarn, fire wood etc and testing complete all as specified (Excavation and earth work shall be measured and paid seperately):- |
| 60 | All as per item No 59 here-in-before but 100mm dia bore |
| 61 | All as per item No 59 here-in-before but 150mm dia bore |
| 62 | Day to day maintaince / repair / rectifiction of any type of water supply complaints like No water Supply or building mounted PVC OHT or any size and any type by digging along with the length upto 01 mter of water pipe line and in any type of soil upto the bottom of pipe to locate the exact pin point location of fault including rectification of fault with the help of plumber, returning filling of same by tightening and including replacing of GI union, elbows, sockets, tees, nipple, check nuts barrel nipple or cast iron special and fittings etc of any size and type as and when required complete all as specified and directed by Engineer-in-Charge. Note: (i) Exacavation shall measured & paid separately under relevant items of this schedule. (ii) The all fitings like GI union, elbows, sockets, tees, nipple, check nuts barrel nipple, reducer any type and any size required to replace up to 80 mm shall deemed to above coated rates not measured & paid seperately iii) Contractor is fully responsible to provide necessary, transportaion, T&P and safty equipment to his Plumber & helper to prevent any type of accidents and department will not responsible to provide any type of compensation to the contractor or his labour in case of any type of accidents / miss-happening or any type of casualty to his labour / plumber. |
| 63 | Supply only Water Testing Kit suitable for testing potable water quality parameters such as pH value and residual chlorine, complete with comparator, glass test tubes/vials, colour chart, 250 ml pH testing solution (Phenol Red), 250 ml chlorine testing solution (DPD/OTO), carrying case and all necessary accessories, complete all as specified and directed |
| 64 | Providing services for Inspection of bore well of any depth by deploying a geo-scanning borehole camera system for detailed examination of the bore well casing, housing pipe, joints, screen/strainer, water column and other down-hole conditions to identify defects, obstructions, damages, corrosion, collapse, misalignment, sand ingress or any other abnormalities affecting the performance of the bore well, including submission of inspection report, observations and recommendations for rectification/remedial measures, complete all as specified and directed. |
| 65 | Supply and Fix First Aid Box of approved quality, made of glazed glass front with wooden frame/backing board, suitable for wall mounting, complete with lock arrangement and containing the following items:(a) Dettol Antiseptic Liquid 100 ml – 01 No(b) Antiseptic Ointment – 01 No(c) Crocin Tablets – 02 Strips(d) Absorbent Cotton Roll – 02 Nos(e) Cotton Bandage Roll – 04 Nos(f) Sterile Gauze Pads – 04 Nos(g) Adhesive Bandages (Band-Aid) – 10 Nos(h) Burnol Burn Cream – 01 No(i) Stainless Steel Scissors(small) – 01 No(j) Disposable Examination Gloves – 02 Pairs(k) ORS Sachets – 02 Nos(l) Snake Bite First Aid Kit – 01 No |
| 66 | Supply, printing and fixing of Pump House Information Board of size 600 mm × 900 mm made of 15 mm × 15 mm MS square tube frame with one coat primer and two coats synthetic enamel paint, comprising approved quality flex/vinyl print fixed on suitable backing sheet displaying Pump House No., Bore Well Details, Pump/Motor Capacity, Year of Construction and other relevant technical particulars as approved by the Engineer-in-Charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender