Tender for Providing Electrical Rewiring In Microbial Lab At Botany, Dept Of Botany, installation Of Science, Bhu, Electrical Wiring Along With Light Fittings In Student Advisor Room, Administrative Building,Inst. Of Agriculture Science,Bhu, Power Wiring In Biochemistry Lab In Soil Science & Agriculture Chemistry, Bhu, Wiring In Store Room At Agriculture Field ,Dept Of Genetics & Plant Breeding, installation Of Agriculture Science ,Bhu, Electrical Wiring In Toilet, Office Of Controller Of Examination,Bhu, Providing Street Light & Light Points In Pump House ,Near Tubewell, Agricultural Research Farm ,Bhu, Replacement Of Short Circuited Wiring In Garage Of G-7,Jodhpur Colony,Bhu, Providing Electrical Wiring At Roof Of Fc-02,Hydrabad Colony,Bhu And Refilling Of Fire Extinguishers Installed At Various Floors In Sb,Bhu.
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Work |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sqmm + 1x1.5 sqmm earth wire |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x4.0 sqmm + 1x4.0 sqmm earth wire |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x10 sqmm + 1x6 sqmm earth wire |
| 6 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x1.5sqmm |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x4.0sqmm |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6x4.0sqmm |
| 9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x6.0sqmm |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 20mm |
| 11 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 25mm |
| 12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 32mm |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet |
| 16 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 17 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 18 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm) |
| 19 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module |
| 20 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 4 Module |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 22 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 23 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 24 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 25 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100A, 36 KA, FP MCCB |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. SPDB 6 way Double DOor |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 8 way , Double door |
| 28 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . VTPNDB 4 way (4 + 12), Double door |
| 29 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPMCB (5-32A) |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DP MCB (5-32A) |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. TP MCB(5-32A) |
| 32 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. TPN MCB(5-32A) |
| 33 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 34 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 6 way, Double door SPN MCBDB |
| 35 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 36 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 37 | Providing, supplying, installation, testing and commissioning of 20W LED batten light fitting (integrated type) suitable for wall/ceiling mounting, having extruded aluminium housing with opal polycarbonate diffuser, complete with inbuilt driver, mounting accessories etc., operating on 90–300V AC, 50 Hz supply, with power factor ≥0.95, CRI ≥80 and minimum efficacy 100 lm/W, ensuring uniform glare-free illumination, conforming to BIS standards, as required. Make-Phillips/Wipro/Crompton |
| 38 | Providing, supplying, installation, testing and commissioning of 1200 mm sweep ceiling fan, complete with down rod, canopy, shackle kit, blades, and all accessories, suitable for operation on 230V, 50 Hz AC supply, including connection with suitable copper conductor wire, earthing, and fixing to ceiling, conforming to IS standards and as required. Make-Bjaj/Usha/Crompton |
| 39 | Providing and fixing 300 mm sweep energy efficient metal exhaust fan, suitable for 230 V, 50 Hz AC, speed not less than 900 RPM, with aerodynamically designed blades, corrosion-resistant body and automatic louvre/shutter arrangement, complete with all necessary mounting accessories, including connection, testing and commissioning, complete as required. Make- Crompton/Bajaj/Usha |
| 40 | Providing and fixing 450 mm sweep energy efficient metal exhaust fan, suitable for 230 V, 50 Hz AC, speed not less than 900 RPM, with aerodynamically designed blades, corrosion-resistant body and automatic louvre/shutter arrangement, complete with all necessary mounting accessories, including connection, testing and commissioning, complete as required. Make- Crompton/Bajaj/Usha |
| 41 | Providing and fixing 400 mm sweep energy efficient wall mounted fan, suitable for 230 V, 50 Hz AC, speed not less than 900 RPM, complete with oscillating mechanism, speed control arrangement, aerodynamically designed blades, protective guard and all necessary wall mounting accessories, including connection, testing and commissioning, complete as required. Make- Crompton/Bajaj/Usha |
| 42 | Supply, installation, testing & Commissioning of 10W LED Bulkhead Light, pressure die-cast aluminium body, IP66, complete with LED driver, mounting accessories, testing and commissioning, with 3 years warranty, Make: Crompton/Phillips/Wipro |
| 43 | Providing and fixing 72W LED Street Light Fitting, high-power LED luminaire with die-cast aluminium housing, high-efficiency LED driver, minimum 100 lm/W luminous efficacy, IP66 protection, IK08 impact resistance, 4000K/5700K colour temperature, PF ≥ 0.95, THD ≤ 10%, operating voltage 140–270V AC, surge protection 4kV, suitable for pole mounting, complete with all accessories, connections and commissioning. |
| 44 | Providing and fixing 2' × 2' LED light fittings, suitable for recessed / surface mounted / suspended installation, complete with aluminium housing, high efficiency LEDs, glare-free diffuser/optical system, constant current electronic LED driver, suitable for operation on 230 V, 50 Hz AC supply, power factor ≥ 0.90, CRI ≥ 80, colour temperature 4000K–6500K, system efficacy not less than 100 lm/W, complete with all mounting accessories, suspension arrangement wherever required, connections, testing and commissioning, as required, Watt-36W Make- Crompton/Wipro/Phillips |
| 45 | Refilling of ABC Type (MAP 90) Fire Extinguisher, 6 kg Capacity, Make: Ceasefire, including inspection, servicing, replacement of seals and O-rings, loading, unloading, transportation to and fro, testing and commissioning, complete. |
| 46 | Refilling of CO₂ Type Fire Extinguisher, 4.5 kg Capacity, including inspection, servicing, replacement of necessary seals, loading, unloading, transportation to and fro, testing and commissioning, complete. |
| 47 | Refilling of Water Type Fire Extinguisher, 50 Litre Capacity, including inspection, servicing, replacement of necessary seals, loading, unloading, transportation to and fro, testing and commissioning, complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender