Educational and Research Institute Government Departments Closing in 9 days TDR #58498406

Tender For Supply Installation Testing and Commissioning of 2000 Cfm Ahu With Associated Work In Room No- 703, Esb- 2 Building, Iit Kanpur.

Issued by Government Departments · Kanpur Nagar, Uttar Pradesh
Tender Value
4.26 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
9 days left
EMD
8531
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of 2000 Cfm Ahu With Associated Work In Room No- 703, Esb- 2 Building, Iit Kanpur.

BOQ

Name of Work:- SITC of 2000 CFM AHU with associated work in Room no- 703, ESB- 2 Building, IIT Kanpur.
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of AHRI certified, double skin sheet metal construction, thermal break profile, with direct coupled EC fan and Ceiling suspended air handling units without mixing box, with supply air damper air (AL) damper, with injected PUF of density not less than 40Kg/CuM and .The air handling units shall be complete with 50mm thick synthetic type pre- filters with Aluminium wire mess, cooling coil (minimum thickness 0.5mm ) section with 6/8 RD seamless solid drawn copper tubes and aluminium fins construction, fan section shall be AMCA certified centrifugal type plug fan complete with direct driven package, limits switch, marine light & stainless steel drain pan ( minimum thickness 1.25 mm and 13 mm close nitrile insulation ) and vibration isolation spring/cushy-foot mount. AHUs shall be selected for a maximum face velocity of 500 FPM (2.5 MPS). Maximum outlet air velocity shall not exceed 2000 FPM (10.1 MPS). With speed controller of EC Fan as per specifications, with 2-way motorised valve and thermostat for temperature and speed control.
22000 CFM, 35 mmwc static, with 50 mm thick PUF injected. Min 6TR cooling capacity, Ceiling suspended type.
3CHILLED WATER PIPING
4Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled/condenser water piping plumbing i/c fabrication of bends / elbows, tees, reducers etc) inside the building (with necessary clamps, wooden/puf support, vibration isolators, primer/ enamel paint, fittings but excluding valves, strainers, gauges etc.) as per specifications and as required complete in all respect.Note:- The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
525 mm
632 mm
740 mm
850 mm
965 mm
1080 mm
11Supplying & fixing insulation on existing MS 'C' class pipe over exposed surface/underground of following sizes with 50 mm thick fire retardant thermocole ( polystyrene) molded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessian cloth, wire mesh, sand-cement plaster & enamel painting two or more coat to give even shade after applying one coat of ordinary paint etc complete as required.
1225 mm
1332 mm
1440 mm
1550 mm
1665 mm
1780 mm
18Supplying, fixing, testing and commissioning of following BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating size 200 mm to 400 mm gear type with removable wheel and below 200 mm with hand lever operated for chilled water/hot water circulation in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications as specified.
1940 mm
2050 mm
21Supply and fixing industrial type thermometer of proportioning length with adjustable angle, direct reading including thermo well socket. Thermometer shall be suitable to read water temperature of range 0°C to 50°C completed as required.
22Providing and fixing 0-150 PSIG industrial type pressure gauge in position of 65/100 mm dia with petcock valves (gun metal / brass) complete with pressure snubber, nipple etc complete as required.
23Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required
24Thickness 0.63 mm sheet
25Thickness 0.80 mm sheet
26Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required.
27Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required.
28Providing & fixing of thermal insulation with aluminium foil faced XLPE Class 'O' insulation sheet of following thickness on existing surface of pipe/duct with dentrite/adhesive etc.The joints shall be sealed with 50 mm wide and self adhesive PVC/Aluminum tape complete as required.
2919 mm
30P & F of acoustic insulation with open cell Nitrile rubber sheet(Accosound) super silence of following thickness, on existing surface with adhesive i/c nut, bolt washer as req on duct.etc. complete as required.
3110 mm
32Providing & fixing of SS ball valve of following size with compatible to proportioning Copper/MS pipe i/c all necessary accessories, support /hangers, including old dismantling if any complete as reqd.
3325 mm
3432 mm
35Providing & fixing of three phase DOL starter Suitable for following size motor, 415 Volts, Auto manual selector switch, single phase preventer, wideband coil, ammeter, ON-OFF Push button etc. complete as required.
36Upto 5 H.P
37Providing, laying, testing, and commissioning of following size Un-armoured XLPE insulated Copper conductor power/control cable of following size on surface/recessed complete as required.
383 Core x 1.5 Sq mm
394 Core x 2.5 Sq mm
40Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58498406
AUTHORITY Government Departments
TENDER VALUE 4.26 Lakhs
LAST DATE 23-11-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Supply Installation Testing and Commissioning of 2000 Cfm Ahu With Associated Work In Room No- 703, Esb- 2 Building, Iit Kanpur.
Basic Detail
Tender No 22/AC/SE/2026/254
Bidding Type Tender
Location
City Kanpur Nagar
State Uttar Pradesh
Key Dates
Publish Date 12 Nov 2026
Submission Date 23 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 4.26 Lakhs
Tender Fee Ref. Documents
EMD 8531
Exemption Not Available
Document List
BOQ_981635.xls
cca76ae3-2c49-44db-a54b-7d7a97764bf0.html
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_981635.xls

html

cca76ae3-2c49-44db-a54b-7d7a97764bf0.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender