Tender For Electrical Rewiring Work Including Supply Installation Testing and Commissioning of Ups, Battery & Cable Laying Work In Department Of Genetics & Plant Breeding, Institute Of Agricultural Science, Bhu
Tender Value
17.55 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
5 days left
EMD
35109
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Rewiring Work Including Supply Installation Testing and Commissioning of Ups, Battery & Cable Laying Work In Department Of Genetics & Plant Breeding, Institute Of Agricultural Science, Bhu
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Work |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sqmm + 1x1.5 sqmm earth wire |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x4.0 sqmm + 1x4.0 sqmm earth wire |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x6.0 sqmm + 1x6.0 sqmm earth wire |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x10 sqmm + 1x6 sqmm earth wire |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4x10 sqmm + 2x6 sq mm earth wire |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x1.5sqmm wire |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm |
| 10 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 13 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 14 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100A, 30 KA, FP MCCB |
| 15 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125A, 36 KA, FP MCCB |
| 16 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. SPDB 8 way , Double door |
| 17 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. TPNDB 6 way (4 + 18), Double door |
| 18 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. TPNDB (4 + 24), Double door |
| 19 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required 4 way (4 + 12), Double door |
| 20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole MCB (5-32A) |
| 21 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole MCB (5-32A) |
| 22 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triplpe Pole MCB(5-32A) |
| 23 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 24 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 25 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB |
| 26 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB |
| 27 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB |
| 28 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 29 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50.0 mm depth X 1.6 mm thickness |
| 30 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 31 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 32 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 33 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 34 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 35 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 36 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 ½ x 25 sq. mm (28 mm) Lugs |
| 37 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 ½ x 35 sq. mm (35 mm) Lugs |
| 38 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 ½ x 95 sq. mm (45 mm) Lugs |
| 39 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 40 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) -36W |
| 41 | Providing and fixing 400 mm sweep energy efficient wall mounted fan, suitable for 230 V, 50 Hz AC, speed not less than 900 RPM, complete with oscillating mechanism, speed control arrangement, aerodynamically designed blades, protective guard and all necessary wall mounting accessories, including connection, testing and commissioning, complete as required. |
| 42 | Providing and fixing 300 mm sweep energy efficient metal exhaust fan, suitable for 230 V, 50 Hz AC, speed not less than 900 RPM, with aerodynamically designed blades, corrosion-resistant body and automatic louvre/shutter arrangement, complete with all necessary mounting accessories, including connection, testing and commissioning, complete as required. |
| 43 | Supply of 1.1 kV grade XLPE insulated, PVC sheathed, armoured, aluminium conductor,conforming to relevent IS, complete as required. Cable 3 1/2 C x 35 sq mm, |
| 44 | Supply of 1.1 kV grade XLPE insulated, PVC sheathed, armoured, aluminium conductor,conforming to relevent IS, complete as required. Cable 3 1/2 C x 95 sq mm |
| 45 | Supply, installation, testing and commissioning of 10 kVA capacity, online double-conversion type, microprocessor-controlled UPS system, 1-phase AC input and 1-phase AC output, 240V AC, 50 Hz, with IGBT-based rectifier/inverter, static bypass and manual maintenance bypass facility, automatic voltage regulation, overload and short-circuit protection, input/output isolation and necessary indications, alarms and display, complete with all standard accessories, internal wiring, connectors, earthing arrangement and interconnections, suitable for operation with external 120V DC battery bank, complete in all respects. |
| 46 | Supply, installation, testing and commissioning of sealed maintenance-free (SMF) valve-regulated lead-acid (VRLA) battery, 12V, 100Ah capacity, suitable for 10 kVA online UPS system, complete with battery interconnecting links, terminal connectors, protective covers, necessary hardware and accessories, including interconnection with UPS through 10 sq.mm (minimum 10sqmm or higher as required) PVC insulated copper conductor cable of suitable grade, including lugs, ferrules, termination and all necessary connections, complete in all respects, as suitable to provide 1-hour backup at the specified UPS load. |
| 47 | Providing, supplying, installation and fixing of suitable size battery rack/cabinet for installation of SMF/VRLA batteries, fabricated from suitable gauge CRCA sheet steel/structural steel sections, duly powder coated with approved shade, complete with adequate load-bearing capacity, shelves/trays, ventilation openings for heat dissipation, anti-corrosive treatment, suitable supports, hardware, nuts, bolts and other necessary accessories, including proper arrangement for placement and maintenance of 10 no. of batteries, complete in all respects as required at site. |
| 48 | SITC 1 Phase, 2.0 Ton Referigeration( TR ) capacity split type wall mounted air conditioners having 5 star energy rating, energy efficient , Rotary compressor, LED panel display, LCD remote control, sleep mode, Anti Bacteria filter, Auto restart etc suitable for operation on 230 volts, 50 Hz, single phase A.C. Supply including fixing the 2.0 TR outdoor unit duly powder painted of sheet steel suitable for outdoor unit with suitable dash fastener etc as required. (Make:- Daikin /Hitachi / Bluestar / Carrier/Voltas ) |
| 49 | supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 50 | supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 51 | Supplying and fixing of 25 mm nominal dia U PVC pipe of rigid/flexible U PVC pipe with minimum 6 mm thick nitrile rubber insulation along with all essential accessories and suitable clamp for drain pipe including connection to the indoor units etc as required. |
| 52 | Providing and fixing suitable MS steel stand/frame for mounting of outdoor unit of split type AC, either wall or floor mounted, fabricated from adequately sized steel sections, duly epoxy coated/painted with anti-corrosive paint, including necessary supports, brackets, nuts, bolts, fasteners, rubber grommets/anti-vibration pads and grouting/anchoring arrangements, complete in all respects as directed by the Engineer-in-Charge. |
| 53 | Fabrication, supply, installation, testing and commissioning of 200A LT Distribution Panel, floor/wall-mounted, cubical type, having front area approximately 2.00 Sqm, fabricated out of 2 mm thick CRCA sheet, compartmentalised construction with hinged and lockable doors, dust and vermin proof, duly powder coated in approved shade after 7-tank treatment process, including cable alley, suitable-size copper conductor interconnections/solid aluminium busbars, switchgear mounting arrangements, internal wiring, earthing terminals, ferruling, numbering and all necessary accessories, complete in all respects, suitable for operation on 415V, 3-phase, 50Hz AC supply with enclosure protection class IP-42, comprising the following switchgears and accessories:1. MCCB incomer, 4-pole, 200A, 36kA breaking capacity – 1 No.2. Digital voltmeter, 0–500V with selector switch – 1 No.3. LED type R-Y-B phase indication lamps – 1 Set.4. Aluminium busbar set, 4 Nos., rated 200A – 1 Set.5. MCCB outgoing feeder, 4-pole, 100A, 30kA breaking capacity – 2 Nos.6. MCCB outgoing feeder, 4-pole, 63A, 30kA breaking capacity – 6 Nos.7. MCB outgoing feeder arrangement with 3 Nos. DP MCB, 32A – 1 Set.The item shall include complete internal power and control wiring, interconnections, busbar supports, cable termination arrangements, hardware, glands, lugs, insulators, earthing connections, identification labels and all other materials, labour, testing and commissioning required to make the panel fully functional. |
| 54 | Dismantling and removal of existing electrical wiring, cables, conduits, switches, sockets, switch boxes, boards, distribution boards (DBs), Kit-Kat fuse boxes and other associated electrical accessories, including disconnection, removal of clamps and supports, and placing the dismantled materials at the designated location or existing cable tray, as directed by the Engineer-in-Charge, complete in all respects. |
| 55 | Buyback of dismantled existing electrical materials, including old detoriated wiring, conduits, switches, sockets, switch boxes, wooden boards, Kit-Kat fuse boxes only, on an as-is-where-is basis, as available at site as directed by Engineer in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender