Educational and Research Institute Boards / Undertakings / PSU Closing in 5 days TDR #58498401

Tender For Electrical Rewiring Work Including Supply Installation Testing and Commissioning of Ups, Battery & Cable Laying Work In Department Of Genetics & Plant Breeding, Institute Of Agricultural Science, Bhu

Issued by Boards / Undertakings / PSU · Varanasi, Uttar Pradesh
Tender Value
17.55 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
5 days left
EMD
35109
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Rewiring Work Including Supply Installation Testing and Commissioning of Ups, Battery & Cable Laying Work In Department Of Genetics & Plant Breeding, Institute Of Agricultural Science, Bhu

BOQ

Name of Work:- Electrical rewiring work including SITC of UPS, battery & cable laying work in Department of Genetics & Plant Breeding, Institute of Agricultural Science, BHU
Sl. No. Item Description
1Electrical Work
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sqmm + 1x1.5 sqmm earth wire
4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x4.0 sqmm + 1x4.0 sqmm earth wire
5Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x6.0 sqmm + 1x6.0 sqmm earth wire
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x10 sqmm + 1x6 sqmm earth wire
7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4x10 sqmm + 2x6 sq mm earth wire
8Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x1.5sqmm wire
9Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm
10Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
12Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
13Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
14Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100A, 30 KA, FP MCCB
15Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125A, 36 KA, FP MCCB
16Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. SPDB 8 way , Double door
17Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. TPNDB 6 way (4 + 18), Double door
18Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. TPNDB (4 + 24), Double door
19Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required 4 way (4 + 12), Double door
20Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole MCB (5-32A)
21Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole MCB (5-32A)
22Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triplpe Pole MCB(5-32A)
23Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
24Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
25Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
26Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB
27Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB
28Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
29Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50.0 mm depth X 1.6 mm thickness
30Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 62.5 mm depth X 2.0 mm thickness
31Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
32Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
33Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
34Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
35Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
36Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 ½ x 25 sq. mm (28 mm) Lugs
37Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 ½ x 35 sq. mm (35 mm) Lugs
38Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 ½ x 95 sq. mm (45 mm) Lugs
39Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
40LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) -36W
41Providing and fixing 400 mm sweep energy efficient wall mounted fan, suitable for 230 V, 50 Hz AC, speed not less than 900 RPM, complete with oscillating mechanism, speed control arrangement, aerodynamically designed blades, protective guard and all necessary wall mounting accessories, including connection, testing and commissioning, complete as required.
42Providing and fixing 300 mm sweep energy efficient metal exhaust fan, suitable for 230 V, 50 Hz AC, speed not less than 900 RPM, with aerodynamically designed blades, corrosion-resistant body and automatic louvre/shutter arrangement, complete with all necessary mounting accessories, including connection, testing and commissioning, complete as required.
43Supply of 1.1 kV grade XLPE insulated, PVC sheathed, armoured, aluminium conductor,conforming to relevent IS, complete as required. Cable 3 1/2 C x 35 sq mm,
44Supply of 1.1 kV grade XLPE insulated, PVC sheathed, armoured, aluminium conductor,conforming to relevent IS, complete as required. Cable 3 1/2 C x 95 sq mm
45Supply, installation, testing and commissioning of 10 kVA capacity, online double-conversion type, microprocessor-controlled UPS system, 1-phase AC input and 1-phase AC output, 240V AC, 50 Hz, with IGBT-based rectifier/inverter, static bypass and manual maintenance bypass facility, automatic voltage regulation, overload and short-circuit protection, input/output isolation and necessary indications, alarms and display, complete with all standard accessories, internal wiring, connectors, earthing arrangement and interconnections, suitable for operation with external 120V DC battery bank, complete in all respects.
46Supply, installation, testing and commissioning of sealed maintenance-free (SMF) valve-regulated lead-acid (VRLA) battery, 12V, 100Ah capacity, suitable for 10 kVA online UPS system, complete with battery interconnecting links, terminal connectors, protective covers, necessary hardware and accessories, including interconnection with UPS through 10 sq.mm (minimum 10sqmm or higher as required) PVC insulated copper conductor cable of suitable grade, including lugs, ferrules, termination and all necessary connections, complete in all respects, as suitable to provide 1-hour backup at the specified UPS load.
47Providing, supplying, installation and fixing of suitable size battery rack/cabinet for installation of SMF/VRLA batteries, fabricated from suitable gauge CRCA sheet steel/structural steel sections, duly powder coated with approved shade, complete with adequate load-bearing capacity, shelves/trays, ventilation openings for heat dissipation, anti-corrosive treatment, suitable supports, hardware, nuts, bolts and other necessary accessories, including proper arrangement for placement and maintenance of 10 no. of batteries, complete in all respects as required at site.
48SITC 1 Phase, 2.0 Ton Referigeration( TR ) capacity split type wall mounted air conditioners having 5 star energy rating, energy efficient , Rotary compressor, LED panel display, LCD remote control, sleep mode, Anti Bacteria filter, Auto restart etc suitable for operation on 230 volts, 50 Hz, single phase A.C. Supply including fixing the 2.0 TR outdoor unit duly powder painted of sheet steel suitable for outdoor unit with suitable dash fastener etc as required. (Make:- Daikin /Hitachi / Bluestar / Carrier/Voltas )
49supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
50supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
51Supplying and fixing of 25 mm nominal dia U PVC pipe of rigid/flexible U PVC pipe with minimum 6 mm thick nitrile rubber insulation along with all essential accessories and suitable clamp for drain pipe including connection to the indoor units etc as required.
52Providing and fixing suitable MS steel stand/frame for mounting of outdoor unit of split type AC, either wall or floor mounted, fabricated from adequately sized steel sections, duly epoxy coated/painted with anti-corrosive paint, including necessary supports, brackets, nuts, bolts, fasteners, rubber grommets/anti-vibration pads and grouting/anchoring arrangements, complete in all respects as directed by the Engineer-in-Charge.
53Fabrication, supply, installation, testing and commissioning of 200A LT Distribution Panel, floor/wall-mounted, cubical type, having front area approximately 2.00 Sqm, fabricated out of 2 mm thick CRCA sheet, compartmentalised construction with hinged and lockable doors, dust and vermin proof, duly powder coated in approved shade after 7-tank treatment process, including cable alley, suitable-size copper conductor interconnections/solid aluminium busbars, switchgear mounting arrangements, internal wiring, earthing terminals, ferruling, numbering and all necessary accessories, complete in all respects, suitable for operation on 415V, 3-phase, 50Hz AC supply with enclosure protection class IP-42, comprising the following switchgears and accessories:1. MCCB incomer, 4-pole, 200A, 36kA breaking capacity – 1 No.2. Digital voltmeter, 0–500V with selector switch – 1 No.3. LED type R-Y-B phase indication lamps – 1 Set.4. Aluminium busbar set, 4 Nos., rated 200A – 1 Set.5. MCCB outgoing feeder, 4-pole, 100A, 30kA breaking capacity – 2 Nos.6. MCCB outgoing feeder, 4-pole, 63A, 30kA breaking capacity – 6 Nos.7. MCB outgoing feeder arrangement with 3 Nos. DP MCB, 32A – 1 Set.The item shall include complete internal power and control wiring, interconnections, busbar supports, cable termination arrangements, hardware, glands, lugs, insulators, earthing connections, identification labels and all other materials, labour, testing and commissioning required to make the panel fully functional.
54Dismantling and removal of existing electrical wiring, cables, conduits, switches, sockets, switch boxes, boards, distribution boards (DBs), Kit-Kat fuse boxes and other associated electrical accessories, including disconnection, removal of clamps and supports, and placing the dismantled materials at the designated location or existing cable tray, as directed by the Engineer-in-Charge, complete in all respects.
55Buyback of dismantled existing electrical materials, including old detoriated wiring, conduits, switches, sockets, switch boxes, wooden boards, Kit-Kat fuse boxes only, on an as-is-where-is basis, as available at site as directed by Engineer in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58498401
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 17.55 Lakhs
LAST DATE 19-11-2026
Authority
Authority Name Banaras Hindu University
Work Description Tender for Electrical Rewiring Work Including Supply Installation Testing and Commissioning of Ups, Battery & Cable Laying Work In Department Of Genetics & Plant Breeding, Institute Of Agricultural Science, Bhu
Basic Detail
Tender No UED/2026/07112026-1
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 12 Nov 2026
Submission Date 19 Nov 2026
Open Date 24 Nov 2026
Finance
Tender Value 17.55 Lakhs
Tender Fee 500
EMD 35109
Exemption Not Available
Document List
a508b511-4498-4b6f-9db4-c12c1790add1.html
Bid_Document03.pdf
BOQ_981588.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

a508b511-4498-4b6f-9db4-c12c1790add1.html

pdf

Bid_Document03.pdf

xls

BOQ_981588.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender