Tender For Repair / Renovation Of Group Of Ancient Temples Vix, Shiv Temple , Shree Kalki Temple , Shree Ganesh Temple And Shree Nand Kishora Asthapan Village Vanpoh Anantnag[Adv. Cost ₹196.60 Lacs (₹ 166.61 Lacs Exclusive Of Gst + Gst@18% ₹ 29.99 La
Tender Overview
Project Description
Tender for Repair / Renovation Of Group Of Ancient Temples Vix, Shiv Temple , Shree Kalki Temple , Shree Ganesh Temple And Shree Nand Kishora Asthapan Village Vanpoh Anantnag[Adv. Cost ₹196.60 Lacs (₹ 166.61 Lacs Exclusive Of Gst + Gst@18% ₹ 29.99 Lacs)]
BOQ
| Sl. No. | Item Description |
| 1 | Adjacent Dharmshala rooms at Shiv Temple |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.(All kinds of soil) |
| 3 | Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete. |
| 4 | Providing and laying in position cement concrete of specified grade M-10 including curing but excluding the cost of centering and shuttering - All work upto plinth level with 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Supply and filling G.S.B. under floors including watering, ramming and consolidating with hand rammer with aggregate size not exceeding 90 mm including cost and carriage of all materials involved upto site of work complete. |
| 7 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works upto plinth level |
| 8 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works above plinth level |
| 9 | Reiforcement for R.C.C work including straightening, cutting, bending, placing in position & binding with binding wire all complete, Thermo Mechanically Treated Bars (500 D) (All work at all levels complete). |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: — Foundations, footings, bases of columns etc for mass concrete. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: — Lintels, beams, plinth beams, griders, bressumers and cantilevers |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: — Stairs, (excluding landings) except spiral staircases : |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: — Suspended floors, roofs, landings, balconies and access plateform |
| 14 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in in superstructure above plinth level upto floor five levelplinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 15 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Imported Wood |
| 16 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : imported wood |
| 17 | Providing and fixing Glazed shutters for doors windows and clerestory windows using 4mm thick float glass panes incl ISI marked Ms pressed butt hings bright finished of reqd size with necessary screws imported wood 35 mm thick |
| 18 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. imported wood |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. Incl primer of approved brand |
| 20 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). — 250 |
| 21 | Providing/Fixing of door window stard wire fittings — i) 100 mm — T.Bolts |
| 22 | Providing/Fixing of door window stard wire fittings — ii) 150 mm — T.Bolts |
| 23 | Providing/Fixing of door window stard wire fittings — i) 125 mm — Handles |
| 24 | Providing/Fixing of door window stard wire fittings — ii) 150 mm — Handles |
| 25 | Providing/Fixing of door window stard wire fittings — i) 200 mm — L-drops (Link) |
| 26 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand) — L-drops (Link) |
| 27 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in fine sand — L-drops (Link) |
| 28 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete — L-drops (Link) |
| 29 | 6mm cement plaster to ceilings of mix 1:3 (1 cement : 3 fine sand) — L-drops (Link) |
| 30 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. — L-drops (Link) |
| 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. — L-drops (Link) |
| 32 | Providing and laying Polished Granite stone flooring in required design and patterns, In linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent including moulding complete job — L-drops (Link) |
| 33 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). — 20 Rm @4kg/m — L-drops (Link) |
| 34 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm — L-drops (Link) |
| 35 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer — 2 — L-drops (Link) |
| 36 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 37 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 — 62X1.5 — L-drops (Link) |
| 38 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 39 | Providing valleys of 90cm wide overall in plain G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 1 mm thick with zinc coating not less than 275 gram/m2 |
| 40 | Providing and fixing plained eaves boarding including emulsion paint, priming coat 2nd KAIL WOOD 250x32 mm (nominal size) |
| 41 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base included) with M.S. screws including enamel paint and priming coat 1st class budloo wood |
| 42 | Plumbing |
| 43 | Providing and fixing white vitreous china pedestal type water closet (Indian type W.C. pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (Hand lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 44 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps (01 Nos), 32 mm C.P. brass waste of standard pattern(01 Nos), including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap ) |
| 45 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. — |
| 46 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 47 | Providing and fixing PTMT Soap Dish holder |
| 48 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms . |
| 49 | Providing and fixing brass bib cock of approved quality 15mm nominal bore — |
| 50 | Providing and fixing 15 mm nomonal bore C.P brass angle value for basin mixer and geyser of approved make confirming to IS: 8931 |
| 51 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 52 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 53 | Providing and fixing C.P. brass 32 mm size bottle trap of approved quality and make and as per the directions of engineer in charge. — |
| 54 | P/F Cholorinated Polyvinyl Choloride ( cpvc ) pipes , havring thermal stablity for hot and cold water supply, incl all cpvc plain and brass threaded fittings . This includes joining of pipes and fittings with one step cpvc solvent coment and testing of joints all complete as per directions of Eic |
| 55 | 15mm nominal outer dia pipes. |
| 56 | 20mm nominal outer dia pipes. |
| 57 | 25mm nominal outer dia pipes. |
| 58 | 32mm nominal outer dia pipes. |
| 59 | 40mm nominal outer dia pipes. |
| 60 | 50mm nominal outer dia pipes. |
| 61 | Centrifugal monoset self priming pump 1.5KW/ 2HP (CROMPTON) |
| 62 | Drainage |
| 63 | Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required. |
| 64 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 110 mm dia |
| 65 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 150 mm dia |
| 66 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 75 mm dia |
| 67 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 50 mm dia |
| 68 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 40 mm dia |
| 69 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 70 | Earth work in excavation in mechanical means in trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(For All Kinds of Soil) |
| 71 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m |
| 72 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 73 | SEPTIC TANK AND SOAKAGE PIT |
| 74 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.(All kinds of soil) |
| 75 | Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete. |
| 76 | Providing and laying in position cement concrete of specified grade M-7.5 including curing but excluding the cost of centering and shuttering - All work upto plinth level with 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 77 | Brick work with F.P.S (non modular) bricks of class designation 75 in superstructure above plinth level upto Floor V level in 1:6 mix (1 cement: 6 coarse sand) including carriage of all materials from approved sources upto site of work complete. |
| 78 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in fine sand |
| 79 | P/l in position RCC 1:1.5:3 20mm nominal size aggregates including carriages complete job |
| 80 | Reinforcement for rcc work incl. cutting bending complete job — @ |
| 81 | Centering shuttering incl. removal of formwork for suspended floors — Soakage pit |
| 82 | Pvc pipe 100mm dia |
| 83 | Repair Renovation Of Group Of Ancient Temples At Village Vanpoh Anantnag Construction Of Guard Rooms At Shiv Temple |
| 84 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.(All kinds of soil) |
| 85 | Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete. |
| 86 | Providing and laying in position cement concrete of specified grade M-10 including curing but excluding the cost of centering and shuttering - All work upto plinth level with 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 87 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 88 | Supply and filling G.S.B. under floors including watering, ramming and consolidating with hand rammer with aggregate size not exceeding 90 mm including cost and carriage of all materials involved upto site of work complete. — @ 85 % |
| 89 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works upto plinth level |
| 90 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works upto plinth level |
| 91 | Reiforcement for R.C.C work including straightening, cutting, bending, placing in position & binding with binding wire all complete, Thermo Mechanically Treated Bars (500 D) (All work at all levels complete). |
| 92 | Centering and shuttering including strutting, propping etc. and removal of form for: — Foundations, footings, bases of columns etc for mass concrete. |
| 93 | Centering and shuttering including strutting, propping etc. and removal of form for: — Lintels, beams, plinth beams, griders, bressumers and cantilevers |
| 94 | Centering and shuttering including strutting, propping etc. and removal of form for: — Stairs, (excluding landings) except spiral staircases : |
| 95 | Centering and shuttering including strutting, propping etc. and removal of form for: — Suspended floors, roofs, landings, balconies and access plateform |
| 96 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in in superstructure above plinth level upto floor five levelplinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 97 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Imported Wood |
| 98 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : imported wood |
| 99 | Providing and fixing Glazed shutters for doors windows and clerestory windows using 4mm thick float glass panes incl ISI marked Ms pressed butt hings bright finished of reqd size with necessary screws imported wood 35 mm thick |
| 100 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. imported wood |
| 101 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 102 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). — 120 |
| 103 | Providing/Fixing of door window stard wire fittings — i) 100 mm — T.Bolts |
| 104 | Providing/Fixing of door window stard wire fittings — ii) 150 mm — T.Bolts |
| 105 | Providing/Fixing of door window stard wire fittings — i) 125 mm — Handles |
| 106 | Providing/Fixing of door window stard wire fittings — ii) 150 mm — Handles |
| 107 | Providing/Fixing of door window stard wire fittings — i) 200 mm — L-drops (Link) |
| 108 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand) |
| 109 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in fine sand |
| 110 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 111 | 6mm cement plaster to ceilings of mix 1:3 (1 cement : 3 fine sand) |
| 112 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 113 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 114 | Providing and laying Polished Granite stone flooring in required design and patterns, In linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent including moulding complete job |
| 115 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 116 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm — L-drops (Link) |
| 117 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 118 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded @ 50kg/sqm 36 sqm x 50 kg = 1800 kg |
| 119 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 — 36X1.5 — |
| 120 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 121 | Providing valleys of 90cm wide overall in plain G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 1 mm thick with zinc coating not less than 275 gram/m2 |
| 122 | Providing and fixing plained eaves boarding including emulsion paint, priming coat 2nd KAIL WOOD 250x32 mm (nominal size) |
| 123 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base included) with M.S. screws including enamel paint and priming coat 1st class budloo wood |
| 124 | Plumbing |
| 125 | Providing and fixing white vitreous china pedestal type water closet (Indian type W.C. pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (Hand lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 126 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps (01 Nos), 32 mm C.P. brass waste of standard pattern(01 Nos), including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap) |
| 127 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 128 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 129 | Providing and fixing PTMT Soap Dish holder |
| 130 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms . |
| 131 | Providing and fixing brass bib cock of approved quality 15mm nominal bore |
| 132 | Providing and fixing 15 mm nomonal bore C.P brass angle value for basin mixer and geyser of approved make confirming to IS: 8931 |
| 133 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 134 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 135 | Providing and fixing C.P. brass 32 mm size bottle trap of approved quality and make and as per the directions of engineer in charge. |
| 136 | P/F Cholorinated Polyvinyl Choloride ( cpvc ) pipes , havring thermal stablity for hot and cold water supply, incl all cpvc plain and brass threaded fittings . This includes joining of pipes and fittings with one step cpvc solvent coment and testing of joints all complete as per directions of Eic |
| 137 | 15mm nominal outer dia pipes. |
| 138 | 20mm nominal outer dia pipes. |
| 139 | 25mm nominal outer dia pipes. |
| 140 | 32mm nominal outer dia pipes. |
| 141 | 40mm nominal outer dia pipes. |
| 142 | 50mm nominal outer dia pipes. |
| 143 | Centrifugal monoset self priming pump 1.5KW/ 2HP (CROMPTON) |
| 144 | Drainage |
| 145 | Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required. |
| 146 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 110 mm dia |
| 147 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 150 mm dia |
| 148 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 75 mm dia |
| 149 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 50 mm dia |
| 150 | Providing, Fixing, Testing & Commissioning PVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) — 40 mm dia |
| 151 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 152 | Earth work in excavation by mechanical means using hydrallic excavator in trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(For All Kinds of Soil) |
| 153 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m |
| 154 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 155 | SEPTIC TANK AND SOAKAGE PIT |
| 156 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.(All kinds of soil) |
| 157 | Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete. |
| 158 | Providing and laying in position cement concrete of specified grade M-7.5 including curing but excluding the cost of centering and shuttering - All work upto plinth level with 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 159 | Brick work with F.P.S (non modular) bricks of class designation 75 in superstructure above plinth level upto Floor V level in 1:6 mix (1 cement: 6 coarse sand) including carriage of all materials from approved sources upto site of work complete. |
| 160 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in fine sand |
| 161 | P/l in position RCC 1:1.5:3 20mm nominal size aggregates including carriages complete job |
| 162 | Reinforcement for rcc work incl. cutting bending complete job — @ |
| 163 | Centering shuttering incl. removal of formwork for suspended floors — Soakage pit |
| 164 | Pvc pipe 100mm dia |
| 165 | Repair Renovation Of Group Of Ancient Temples And Construction Of Boundary Wall At Shree Nand Kishora At Village Vanpoh Anantnag |
| 166 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 167 | P/l dry stone soling duly hand packed & consolidated with hand rammers inc. all carriage complete job. |
| 168 | Providing and laying in position cement concrete of (1:4:8) ratio excluding the cost of centring, shuttering and carraige of all work in foundation using coarse sand and 40mm nominial size aggregate include carraige of materials complete job. |
| 169 | Centering and shuttering including strutting, propping etc. and removal of form for: — FOOTING |
| 170 | Centering and shuttering including strutting, propping etc. and removal of form for: — beams lintels |
| 171 | Centering and shuttering including strutting, propping etc. and removal of form for: — COLOUMNS |
| 172 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 173 | Steel reinforcement for R.CC work incl straightening , cutting , bending , placing in position and binding all complete above plinth level TMT bars of grade FE 500D or more |
| 174 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 175 | Brick work with F.P.S (non modular) bricks of class designation 75 in superstructure above plinth level upto Floor V level in 1:6 mix (1 cement: 6 coarse sand) including carriage of all materials from approved sources upto site of work complete. |
| 176 | Providing and laying Polished Granite stone flooring in required design and patterns, In linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent including moulding complete job |
| 177 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 178 | Repair Renovation Of Group Of Ancient Temples Ganpat Temple At Village Vanpoh Anantnag |
| 179 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead Of sectional area below 40 sqcm. |
| 180 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet |
| 181 | Centering and shuttering including strutting, propping etc. and removal of form for: — beams lintels |
| 182 | Centering and shuttering including strutting, propping etc. and removal of form for: — Suspended floors, roofs, landings, balconies and access platforms |
| 183 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 184 | Steel reinforcement for R.CC work incl straightening , cutting , bending , placing in position and binding all complete above plinth level TMT bars of grade FE 500D or more |
| 185 | Cast Iron Work in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using CI etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.ORNAMENTAL WORK |
| 186 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood including the cost of frame work & false ceeling ply 12mm Mouj Pattern Dseign & including a coat of touchwood Complete Job |
| 187 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete =20X33=660 SFT=61.39SQMX55KG/SQM=3376 KG |
| 188 | Providing corrugated G. S Clour Caoted (RED Colour). sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 189 | Providing and laying Polished Granite stone flooring in required design and patterns, In linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent including moulding complete job |
| 190 | Providing and fixing Ist quality ceramic Glazed Wall Tiles conforming to IS : 13753 of miniumum thickness 6 mm of approved make in all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sample to be approved by Engineer-in-charge. Size of Tile 450 x 300 mm. (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 191 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 192 | Repair Renovation Of Group Of Ancient Temples And Construction Of Boundary Wall At Ganpat Temple At Village Vanpoh Anantnag |
| 193 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 194 | P/l dry stone soling duly hand packed & consolidated with hand rammers inc. all carriage complete job. |
| 195 | Providing and laying in position cement concrete of (1:4:8) ratio excluding the cost of centring, shuttering and carraige of all work in foundation using coarse sand and 40mm nominial size aggregate include carraige of materials complete job. |
| 196 | Centering and shuttering including strutting, propping etc. and removal of form for: — FOOTING |
| 197 | Centering and shuttering including strutting, propping etc. and removal of form for: — beams lintels |
| 198 | Centering and shuttering including strutting, propping etc. and removal of form for: — COLOUMNS |
| 199 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 200 | Steel reinforcement for R.CC work incl straightening , cutting , bending , placing in position and binding all complete above plinth level TMT bars of grade FE 500D or more |
| 201 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 202 | Brick work with F.P.S (non modular) bricks of class designation 75 in superstructure above plinth level upto Floor V level in 1:6 mix (1 cement: 6 coarse sand) including carriage of all materials from approved sources upto site of work complete. |
| 203 | CUTTING OF TREES 600-1200 mm |
| 204 | Repair Renovation Of Group Of Ancient Temples Shiv Temple At Village Vanpoh Anantnag |
| 205 | Dismantling of Existing site by way of Engagement of Men & Machinery and stacking of servicable Disposing off malba as directed by EIC |
| 206 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. — @45 kg /sqm |
| 207 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet |
| 208 | Centering and shuttering including strutting, propping etc. and removal of form for: — beams lintels |
| 209 | Centering and shuttering including strutting, propping etc. and removal of form for: — Suspended floors, roofs, landings, balconies and access platforms |
| 210 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 211 | Steel reinforcement for R.CC work incl straightening , cutting , bending , placing in position and binding all complete above plinth level TMT bars of grade FE 500D or more |
| 212 | Cast Iron Work in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using CI etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.ORNAMENTAL WORK |
| 213 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood including the cost of frame work & false ceeling ply 12mm Mouj Pattern Dseign & including a coat of touchwood Complete Job |
| 214 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete =20x18=360SFT=33.48SQMX55KG/SQM=1841.86 KG |
| 215 | Providing corrugated G. S Clour Caoted (RED Colour). sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 216 | Providing and laying Polished Granite stone flooring in required design and patterns, In linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent including moulding complete job |
| 217 | Engagement of JCB |
| 218 | Engagement of Tractor |
| 219 | Repair Renovation Of Group Of Ancient Temples Kalki Temple At Village Vanpoh Anantnag |
| 220 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. — @45 kg /sqm |
| 221 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet |
| 222 | Centering and shuttering including strutting, propping etc. and removal of form for: — beams lintels |
| 223 | Centering and shuttering including strutting, propping etc. and removal of form for: — Suspended floors, roofs, landings, balconies and access platforms |
| 224 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upt plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 225 | Steel reinforcement for R.CC work incl straightening , cutting , bending , placing in position and binding all complete above plinth level TMT bars of grade FE 500D or more |
| 226 | Cast Iron Work in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using CI etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.ORNAMENTAL WORK |
| 227 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood including the cost of frame work & false ceeling ply 12mm Mouj Pattern Dseign & including a coat of touchwood Complete Job |
| 228 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete =21X16.5=346.50SFT=32.69SQMX55KG/SQM=1797.95 KG |
| 229 | Providing corrugated G. S Clour Caoted (RED Colour). sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 230 | Providing and laying Polished Granite stone flooring in required design and patterns, In linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent including moulding complete job |
| 231 | Providing and fixing Ist quality ceramic Glazed Wall Tiles conforming to IS : 13753 of miniumum thickness 6 mm of approved make in all colours, shades except begundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sample to be approved by Engineer-in-charge. Size of Tile 450 x 300 mm. (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 232 | CUTTING OF TREES 600-1200 mm |
| 233 | Electric part ( Renovation of Group of ancient Temples at Village Vanpoh anantnag) |
| 234 | 01 Shiv Temple- C/O Adjacent Rooms( Electric part) |
| 235 | Wiring for light point/fan point/exhaust fan point/call bell point with 2 x 1.5 sq.mm PVC insulated, FRLS copper conductor, 1100 V grade wires, complete with all accessories (Havells/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK or eq.) single core cable in surface/recessed medium class PVC conduit (including cost of conduit), with modular switch (Legrand/SSK/Schneider/Crabtree/Athena/ABB make), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 236 | Group-A |
| 237 | Wiring for light/power plug with 2X4 sq.mm + 1X4 sq.mm earth wire, FRLS PVC insulated copper conductor (Havells/Polycab/Fenolex/Anchor/SSK equivalent as directed by Engineer-in-charge) single core cable in surface/recessed medium class PVC conduit (including cost of conduit). |
| 238 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable GI box, connections etc. as required (Legrand/SSK/Schneider/Crabtree/Athena/ABB make). |
| 239 | Wiring for lighting circuits/inverter circuits/6-10 amp power plug with 2X2.5 sq.mm FRLS PVC insulated copper conductor (Havells/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK make) single core cable in surface/recessed medium class PVC conduit (including cost of conduit) along with 1 No. 2.5 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 240 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5-10 A modular socket outlet and 2 nos. 5-10 A modular switch, connections etc. as required (Legrand/SSK/Schneider/Crabtree/Athena/ABB make). |
| 241 | Supplying and fixing of following modular switch/socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required: i. 3 pin 5/6A socket outlet. |
| 242 | Supplying and fixing of following modular switch/socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required: i. Indicator. |
| 243 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor (Havells/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor make) as described in item no. 1, single core cable in surface/recessed medium class PVC conduit as required, including cost of conduit. |
| 244 | 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire (Inverter Circuit) |
| 245 | 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire (Lighting Circuit) |
| 246 | 2 X 6 sq.mm + 1 X 6 sq.mm earth wire (Lighting submain) |
| 247 | 2 X 10 sq.mm + 1 X 6 sq.mm earth wire (Heating submain) |
| 248 | S/F, testing and commissioning of MCBs 10 kA of the below mentioned capacities in sub main controls, Legrand C curve, Schneider/Legrand/ABB/Havells/Siemens/L&T/Hager/BCH make OR OEMs/firms holding ISO 9001 certification (Quality Management System) as directed by Engineer-in-charge. |
| 249 | 6-32 Amp SP MCB |
| 250 | 32 Amp DP MCB |
| 251 | 63 Amp DP MCB |
| 252 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates. |
| 253 | Supplying and fixing following way, Horizontal type, Single pole and neutral, sheet steel MCB distribution board (Legrand/Schneider/Hager/ABB/SSK/GM make), 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, DIN bar, interconnections, powder painted including earthing etc. as required (but without MCB/RCCB/Isolator). |
| 254 | 16 way, Double door |
| 255 | Supply, installation, testing and commissioning of 12 W LED surface/recess, square or round mounted light luminaire with minimum system lumen efficacy of 100 lm/W. Input voltage range 150V to 270V. Fixture shall have in-built surge protection of 2kV. Certification: LM79 & LM80 test report from govt. approved in-house NABL lab/Government of India. The job includes AMC (from date of successful commissioning) of lighting fixtures for a period of two years, including replacement of fixtures (Philips/Havells/Wipro or eq. make; sample to be approved before installation). |
| 256 | Supply, installation, testing and commissioning of exhaust fan of 200-250 mm sweep suitable for wall/window mounting, complete with necessary frame, mounting arrangement, louvers/shutter and all accessories as required; robust construction with high-grade engineering plastic/metal body, aerodynamically designed blades and heavy-duty copper motor suitable for continuous operation, conforming to relevant Indian Standards and safety requirements (Havells/Bajaj/Crompton/Usha/Orient OR OEMs/firms holding ISO 9001 certification) as directed by Engineer-in-charge as per site requirement, with necessary connections. |
| 257 | Supply, installation, testing and commissioning of 1200 mm sweep, one star ceiling fan suitable for 230 V, 50 Hz, single phase AC supply, incl. necessary connections etc. complete as required (Atomberg/Orient/Usha/Havells/Crompton/Anchor). |
| 258 | Supply and fixing of 6 amp/250 V A.C. fan dimmer step type, two module with cover plate (Anchor Roma Plus/SSK/ABB/Schneider/Legrand or equivalent make). |
| 259 | S/Laying (partly overhead/partly underground), testing and commissioning of XLPE aluminium armoured cable 650 V/1100 V grade as per IS 7098 (Part 1) 1988 with up-to-date amendments (Havells/eq. standard make as directed by Engineer-in-charge) and making end termination with brass compression gland and aluminium lugs of required size. |
| 260 | 35 sq.mm 2 core (armoured) |
| 261 | PANEL: Design, fabrication, supplying, installation, testing and commissioning of following panel, manufactured from CPRI approved manufacturer, made out of 2 mm thick M.S. sheet steel, floor mounted, vermin and dust proof, outdoor type with suitable size angle iron legs for grouting in the ground, with lockable hinged doors, duly painted, with provision for fixing of following switch gear, aluminium bus bar of various ratings after taking derating factor into account, and other allied accessories etc. as required. Scope also includes securely installing the panel into the ground with concrete encasing its legs (as per approved design; size may vary as per site requirement). |
| 262 | INCOMING |
| 263 | 125 amp DP MCB 10 kA, Legrand/Schneider/L&T/ABB make. |
| 264 | 2 Nos. of Aluminium Bus Bar of 200 Amp. |
| 265 | Change over switch 63 Amp, front operated |
| 266 | 2 Nos. of Aluminium Bus Bar of 200 Amp. |
| 267 | Digital meters and phase indicators - 1 set. |
| 268 | OUTGOING |
| 269 | 63 amp DP 10 kA MCB |
| 270 | 40 amp DP 10 kA MCB |
| 271 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit then embedding 2.5 mtr. long GI earthing electrode, 60 mm dia. Connecting the electrode with main control board by 10 SWG copper wire with 1/2\\" dia. full thread brass nut and bolts and washers, refilling the pit with chemical compound. |
| 272 | Supply, installation, testing and commissioning of flood light 50 W (warm white), epoxy powder coated die-cast aluminium housing (LM24) with heat sink, PG9 gland for cable entry and provision for loop-in loop-out, class 1, IP66, IK07, high power LEDs, built-in potted IP67 electronic LED driver with APFC, low THD, toughened glass and secondary lens, open circuit protection, over voltage protection, surge protection up to 10 kV with built-in SPD & other safety tests as per IS 15885 Part-2/Sec 13, IEC 60598-1 (Philips/Havells/Wipro/Crompton). Includes angle iron stand of suitable size grouted in cement concrete with hold fasteners, complete job. |
| 273 | Supply and installation of 32A modular plug/socket with 32A DP MCB for ACs. |
| 274 | Supply, installation, testing and commissioning of minimum 2KVA Power Inverter (Pure Sine Wave type) having generator compatible & provided and fitted with 2 no. 12V, 200 Ah, tall tubular batteries of Exide make and PVC trolley for resting/ housing of batteries. The job also includes terminal connections of batteries, Input/output leads of required size and length, carriage and applicable taxes. |
| 275 | Supply, Installation, testing and commissioning of 3 star rating 1.5 Ton Inverter type split Air Conditioners suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed Inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector Internal Junit with one Indoor and one outdoor unit. The Indoor unit fitted on wall by employing sultable clamps and the outdoor unit will be placed on angle Iron stand fitted with nut/bolts outside the room to avoid noise, Including standard length of suitable size copper tubing covered with nitrile foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC Insulated copper cable and a battery operated wireless remote unit. The job Includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. (Dalkin/ Blue Star/LG/IFB/ Hitachi). |
| 276 | Installation, Testing & commissioning of 2TR/1.8TR & 1.5 TR Capacity Wall mounted Split Air conditioners Including all necessary accessorles, fixing of Indoor Unit, fixing of Outdoor Unit on Dully painted sultable size MS Stand Including grouting/mounting of stand, including first charging of refrigerant with laying of Insulated copper pipe lines liquld and suction lines and Installation of Drain pipe etc. complete for above Item as per site requirement |
| 277 | Supply, Installation, testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from Input voltage 90-260Volt thereby producing output voltage of 230volts +_3%. (4 KVA) |
| 278 | 02 C/O Hall and Guard Room ( Electric part) |
| 279 | Wiring for light point/fan point/exhaust fan point/call bell point with 2x1.5 sq.mm FRLS PVC insulated copper conductor, 1100 V grade wires, complete with all accessories (Havells/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK or eq.), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit), with modular switch (Legrand/SSK/Schneider/Crabtree/Athena/ABB), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC copper conductor, as required. - Group-A |
| 280 | Same as item 1 above - Group-C |
| 281 | Wiring for light/power plug with 2x4 sq.mm + 1x4 sq.mm earth wire, FRLS PVC insulated copper conductor (Havell/Polycab/Fenolex/Anchor/SSK or equivalent as directed by Engineer In-charge), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit) |
| 282 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incl. providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable GI box, connections etc. as required (Legrand/SSK/Schneider/Crabtree/Athena/ABB make) |
| 283 | Wiring for lighting circuits/inverter circuits/6-10 amp power plug with 2x2.5 sq.mm FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK make), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit) along with 1 No. 2.5 sq.mm FRLS PVC insulated copper conductor for loop earthing as required |
| 284 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incl. providing and fixing 3 pin 5-10 A modular socket outlet and 5-10 A modular switch, connections etc. as required (for light plugs in non-residential buildings) (Legrand Mylinc/SSK NV/Schneider Livia/Crabtree/ABB/Athena make) |
| 285 | Supplying and fixing of modular switch/socket/indicator on the existing modular plate and switch box incl. connections but excluding modular plate etc. as required: i. 3 pin 5/6A socket outlet |
| 286 | Supplying and fixing of modular switch/socket/indicator on the existing modular plate and switch box incl. connections but excluding modular plate etc. as required: i. Indicator |
| 287 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor make) as described in item no. 1, single core cable in surface/recessed medium class PVC conduit as required, incl. cost of conduit: |
| 288 | 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire (Inverter Circuit) |
| 289 | 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire (Lighting Circuit) |
| 290 | 2 X 6 sq.mm + 1 X 6 sq.mm earth wire (Lighting submain) |
| 291 | 2 X 10 sq.mm + 1 X 6 sq.mm earth wire (Heating submain) |
| 292 | S/F testing and commissioning of MCBs 10 kA of the below mentioned capacities in sub main controls, C curve (Schneider/Legrand/ABB/Havells/Siemens/L&T/Hager/BCH/SSK make or OEMs/firms holding ISO 9001 certification) as directed by Engineer In-charge: |
| 293 | 6-32 Amp SP MCB |
| 294 | 32 Amp DP MCB |
| 295 | 63 Amp DP MCB |
| 296 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates |
| 297 | Supplying and fixing Horizontal type, SPN/TPN, sheet steel MCB distribution board (Legrand/Schneider/Hager/ABB/SSK/Havells make) 240/415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted incl. earthing etc. as required (but without MCB/RCCB/Isolator): |
| 298 | 4 way (4+12), Double door |
| 299 | Supply, installation, testing and commissioning of 5/6 W LED surface/recess, square or round mounted light luminary, min. system lumen efficacy 100 lm/W, useful life 50000 hrs at L70, separate driver, heat sink, earthing provision, input 150V-270V, in-built surge protection 2kV, LM79 & LM80 test report from govt. approved NABL lab. Includes AMC of lighting fixtures for two years incl. replacement (Philips/Havells/Wipro/Crompton make) |
| 300 | Supply, installation, testing and commissioning of 12 W LED surface/recess, square or round mounted light luminary, min. system lumen efficacy 100 lm/W, useful life 50000 hrs at L70, separate driver, heat sink, earthing provision, input 150V-270V, in-built surge protection 2kV, LM79 & LM80 test report from govt. approved NABL lab. Includes AMC of lighting fixtures for two years incl. replacement (Philips/Havells/Wipro/Crompton make / sample to be approved before installation) |
| 301 | Supply, installation, testing and commissioning of exhaust fan of 200-250 mm sweep suitable for wall/window mounting, complete with frame, mounting arrangement, louvers/shutter and all accessories; robust construction, heavy-duty copper motor, conforming to relevant IS (Havell/Bajaj/Crompton/USHA/Orient/Anchor or OEMs holding ISO 9001) as directed by Engineer In-charge |
| 302 | Supply, installation, testing and commissioning of 1200 mm sweep, one star, ceiling fan suitable for 230 V, 50 Hz, single phase AC supply, incl. necessary connections etc. complete as required (Atomberg/Orient/USHA/Havells/Crompton/Anchor) |
| 303 | Supply, installation, testing and commissioning of flood light 50 W (warm white), epoxy powder coated die-cast aluminium housing (LM24), heat sink, PG9 gland, loop-in/loop-out, class 1, IP66, IK07, high power LEDs, built-in potted IP67 LED driver with APFC, low THD, toughened glass, secondary lens, OCP, OVP, surge protection up to 10 kV with built-in SPD, test as per IS 15885 Part-2/Sec 13, IEC60598-1 (Philips/Havells/Wipro/Crompton make). Includes angle iron stand of suitable size grouted in cement concrete with hold fasteners, complete |
| 304 | Supply and fixing of 6 amp/250 V A.C. fan dimmer, step type, 2 module, with cover plate (Anchor Roma Plus/SSK NV/ABB/Schneider/Legrand or equivalent make) |
| 305 | Supply and fixing of LED ambient strip light 40-45 Watt, system wattage 6W/M (Philips/Panasonic/Havells/Agroculture) |
| 306 | S/Laying (partly overhead/partly underground), testing and commissioning of XLPE aluminium armoured cable 650 V/1100 V grade as per IS 7098 (Part 1) 1988 with upto date amendments (Havells/Eq. standard make) as directed by Engineer In-charge and making end termination with brass compression gland and aluminium lugs of required size: |
| 307 | 50 sq.mm 2 core (armoured) |
| 308 | PANEL: Design, fabrication, supplying, installation, testing and commissioning of following panel, manufactured from CPRI approved manufacturer, made of 2 mm thick M.S. sheet steel, floor mounted, vermin and dust proof, outdoor type with suitable size angle iron legs for grouting in the ground, lockable hinged doors, duly painted with provision for fixing of following switch gears, aluminium bus bar of various ratings after taking derating factor into account, and other allied accessories etc. as required. Includes securely installing the panel into the ground with concrete encasing its legs (as per approved design, size may vary as per site requirement) |
| 309 | INCOMING |
| 310 | 100 amp DP MCB 10 kA Legrand/Schneider/L&T/ABB make |
| 311 | 2 No. of Aluminium Bus Bar of 200 Amp |
| 312 | Change over switch 63 Amp, front operated |
| 313 | 2 No. of Aluminium Bus Bar of 200 Amp |
| 314 | Digital meters and phase indicators |
| 315 | OUTGOING |
| 316 | 63 amp DP 10 kA MCB |
| 317 | 40 amp DP 10 kA MCB |
| 318 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit, then embedding 2.5 mtr. long GI earthing electrode, 60 mm dia., connecting the electrode with main control board by 10 SWG copper wire with 1/2\\" dia. full thread brass nut and bolts and washers, refilling the pit with chemical compound |
| 319 | Supply and installation of 32A modular plug/socket with 32A DP MCB for ACs |
| 320 | Supply, installation, testing and commissioning of 3 star rating 1.5 Ton inverter type split air conditioner suitable for 1-phase 50Hz 230V, hermetically sealed inverter compressor, air cooled condenser, latest R410A/R-32 refrigerant, one indoor and one outdoor unit; indoor unit on wall with suitable clamps, outdoor unit on angle iron stand with nut/bolts, standard length of copper tubing covered with nitrile foam, PVC flexible drain pipe, 3 core sheathed/PVC insulated copper cable, wireless remote. Includes repairs to walls where cut and AMC of AC for one and a half years from commissioning (Daikin/Blue Star/LG/IFB/Hitachi) |
| 321 | Installation, testing & commissioning of 2TR/1.8TR & 1.5 TR capacity wall mounted split air conditioners incl. all necessary accessories, fixing of indoor unit, fixing of outdoor unit on duly painted suitable size MS stand incl. grouting/mounting of stand, first charging of refrigerant with laying of insulated copper pipe lines (liquid and suction), installation of drain pipe etc. complete as per site requirement |
| 322 | Supply, installation, testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90-260 Volt producing output voltage of 230 volts +/-3% (4 KVA) |
| 323 | Supply, installation, testing and commissioning of minimum 2 KVA power inverter (pure sine wave type) having generator compatible & provided and fitted with 2 no. 12V, 200 Ah tall tubular batteries of Exide make and PVC trolley for resting/housing of batteries. Includes terminal connections of batteries, input/output leads of required size and length, carriage and applicable taxes |
| 324 | (Ganpat Temple) (Electric part) |
| 325 | Wiring for light point/fan point/exhaust fan point/call bell point with 2x1.5 sq.mm FRLS PVC insulated copper conductor, 1100 V grade wires, complete with all accessories (Havells/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK or eq.), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit), with modular switch (Legrand/SSK/Schneider/Crabtree/Athena/ABB), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC copper conductor, as required. - Group-A |
| 326 | Wiring for light/power plug with 2x4 sq.mm + 1x4 sq.mm earth wire, FRLS PVC insulated copper conductor (Havell/Polycab/Fenolex/Anchor/SSK or equivalent as directed by Engineer In-charge), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit) |
| 327 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incl. providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable GI box, connections etc. as required (Legrand/SSK/Schneider/Crabtree/Athena/ABB make) |
| 328 | Wiring for lighting circuits/inverter circuits/6-10 amp power plug with 2x2.5 sq.mm FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK make), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit) along with 1 No. 2.5 sq.mm FRLS PVC insulated copper conductor for loop earthing as required |
| 329 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incl. providing and fixing 3 pin 5-10 A modular socket outlet and 5-10 A modular switch, connections etc. as required (for light plugs in non-residential buildings) (Legrand Mylinc/SSK NV/Schneider Livia/Crabtree/ABB/Athena make) |
| 330 | Supplying and fixing of modular switch/socket/indicator on the existing modular plate and switch box incl. connections but excluding modular plate etc. as required: i. 3 pin 5/6A socket outlet |
| 331 | Supplying and fixing of modular switch/socket/indicator on the existing modular plate and switch box incl. connections but excluding modular plate etc. as required: i. Indicator |
| 332 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor make) as described in item no. 1, single core cable in surface/recessed medium class PVC conduit as required, incl. cost of conduit: |
| 333 | 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire (Inverter Circuit) |
| 334 | 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire (Lighting Circuit) |
| 335 | 2 X 6 sq.mm + 1 X 6 sq.mm earth wire (Lighting submain) |
| 336 | 2 X 10 sq.mm + 1 X 6 sq.mm earth wire (Heating submain) |
| 337 | S/F testing and commissioning of MCBs 10 kA of the below mentioned capacities in sub main controls, C curve (Schneider/Legrand/ABB/Havells/Siemens/L&T/Hager/BCH/SSK make or OEMs/firms holding ISO 9001 certification) as directed by Engineer In-charge: |
| 338 | 6-32 Amp SP MCB |
| 339 | 32 Amp DP MCB |
| 340 | 63 Amp DP MCB |
| 341 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates |
| 342 | Supplying and fixing Horizontal type, SPN/TPN, sheet steel MCB distribution board (Legrand/Schneider/Hager/ABB/SSK/Havells make) 240/415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted incl. earthing etc. as required (but without MCB/RCCB/Isolator): |
| 343 | 12 way, Double door |
| 344 | Supply, installation, testing and commissioning of 12 W LED surface/recess, square or round mounted light luminary, min. system lumen efficacy 100 lm/W, useful life 50000 hrs at L70, separate driver, heat sink, earthing provision, input 150V-270V, in-built surge protection 2kV, LM79 & LM80 test report from govt. approved NABL lab. Includes AMC of lighting fixtures for two years incl. replacement (Philips/Havells/Wipro/Crompton make / sample to be approved before installation) |
| 345 | Supply, installation, testing and commissioning of exhaust fan of 200-250 mm sweep suitable for wall/window mounting, complete with frame, mounting arrangement, louvers/shutter and all accessories; robust construction, heavy-duty copper motor, conforming to relevant IS (Havell/Bajaj/Crompton/USHA/Orient/Anchor or OEMs holding ISO 9001) as directed by Engineer In-charge |
| 346 | Supply, installation, testing and commissioning of 1200 mm sweep, one star, ceiling fan suitable for 230 V, 50 Hz, single phase AC supply, incl. necessary connections etc. complete as required (Atomberg/Orient/USHA/Havells/Crompton/Anchor) |
| 347 | Supply, installation, testing and commissioning of flood light 50 W (warm white), epoxy powder coated die-cast aluminium housing (LM24), heat sink, PG9 gland, loop-in/loop-out, class 1, IP66, IK07, high power LEDs, built-in potted IP67 LED driver with APFC, low THD, toughened glass, secondary lens, OCP, OVP, surge protection up to 10 kV with built-in SPD, test as per IS 15885 Part-2/Sec 13, IEC60598-1 (Philips/Havells/Wipro/Crompton make). Includes angle iron stand of suitable size grouted in cement concrete with hold fasteners, complete |
| 348 | Supply and fixing of 6 amp/250 V A.C. fan dimmer, step type, 2 module, with cover plate (Anchor Roma Plus/SSK NV/ABB/Schneider/Legrand or equivalent make) |
| 349 | S/Laying (partly overhead/partly underground), testing and commissioning of XLPE aluminium armoured cable 650 V/1100 V grade as per IS 7098 (Part 1) 1988 with upto date amendments (Havells/Eq. standard make) as directed by Engineer In-charge and making end termination with brass compression gland and aluminium lugs of required size: |
| 350 | 25 sq.mm 2 core (armoured) |
| 351 | Supply, fixing, testing and commissioning of suitable size 63A/100A connector |
| 352 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit, then embedding 2.5 mtr. long GI earthing electrode, 60 mm dia., connecting the electrode with main control board by 10 SWG copper wire with 1/2\\" dia. full thread brass nut and bolts and washers, refilling the pit with chemical compound |
| 353 | Supply, installation, testing and commissioning of minimum 1625 VA power inverter (pure sine wave type) having generator compatible & provided and fitted with 2 no. 12V, 180 Ah tall tubular batteries of Exide/Microtech/Luminous make and PVC trolley for resting/housing of batteries. Includes terminal connections of batteries, input/output leads of required size and length, carriage and applicable taxes |
| 354 | (Shiv Temple) (Electric part) |
| 355 | Wiring for light point/fan point/exhaust fan point/call bell point with 2x1.5 sq.mm FRLS PVC insulated copper conductor, 1100 V grade wires, complete with all accessories (Havells/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK or eq.), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit), with modular switch (Legrand/SSK/Schneider/Crabtree/Athena/ABB), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC copper conductor, as required. - Group-A |
| 356 | Wiring for light/power plug with 2x4 sq.mm + 1x4 sq.mm earth wire, FRLS PVC insulated copper conductor (Havell/Polycab/Fenolex/Anchor/SSK or equivalent as directed by Engineer In-charge), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit) |
| 357 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incl. providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable GI box, connections etc. as required (Legrand/SSK/Schneider/Crabtree/Athena/ABB make) |
| 358 | Wiring for lighting circuits/inverter circuits/6-10 amp power plug with 2x2.5 sq.mm FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK make), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit) along with 1 No. 2.5 sq.mm FRLS PVC insulated copper conductor for loop earthing as required |
| 359 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incl. providing and fixing 3 pin 5-10 A modular socket outlet and 5-10 A modular switch, connections etc. as required (for light plugs in non-residential buildings) (Legrand Mylinc/SSK NV/Schneider Livia/Crabtree/ABB/Athena make) |
| 360 | Supplying and fixing of modular switch/socket/indicator on the existing modular plate and switch box incl. connections but excluding modular plate etc. as required: i. 3 pin 5/6A socket outlet |
| 361 | Supplying and fixing of modular switch/socket/indicator on the existing modular plate and switch box incl. connections but excluding modular plate etc. as required: i. Indicator |
| 362 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor make) as described in item no. 1, single core cable in surface/recessed medium class PVC conduit as required, incl. cost of conduit: |
| 363 | 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire (Inverter Circuit) |
| 364 | 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire (Lighting Circuit) |
| 365 | 2 X 6 sq.mm + 1 X 6 sq.mm earth wire (Lighting submain) |
| 366 | 2 X 10 sq.mm + 1 X 6 sq.mm earth wire (Heating submain) |
| 367 | S/F testing and commissioning of MCBs 10 kA of the below mentioned capacities in sub main controls, C curve (Schneider/Legrand/ABB/Havells/Siemens/L&T/Hager/BCH/SSK make or OEMs/firms holding ISO 9001 certification) as directed by Engineer In-charge: |
| 368 | 6-32 Amp SP MCB |
| 369 | 32 Amp DP MCB |
| 370 | 63 Amp DP MCB |
| 371 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates |
| 372 | Supplying and fixing Horizontal type, SPN/TPN, sheet steel MCB distribution board (Legrand/Schneider/Hager/ABB/SSK/Havells make) 240/415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted incl. earthing etc. as required (but without MCB/RCCB/Isolator): |
| 373 | 12 way, Double door |
| 374 | Supply, installation, testing and commissioning of 12 W LED surface/recess, square or round mounted light luminary, min. system lumen efficacy 100 lm/W, useful life 50000 hrs at L70, separate driver, heat sink, earthing provision, input 150V-270V, in-built surge protection 2kV, LM79 & LM80 test report from govt. approved NABL lab. Includes AMC of lighting fixtures for two years incl. replacement (Philips/Havells/Wipro/Crompton make / sample to be approved before installation) |
| 375 | Supply, installation, testing and commissioning of exhaust fan of 200-250 mm sweep suitable for wall/window mounting, complete with frame, mounting arrangement, louvers/shutter and all accessories; robust construction, heavy-duty copper motor, conforming to relevant IS (Havell/Bajaj/Crompton/USHA/Orient/Anchor or OEMs holding ISO 9001) as directed by Engineer In-charge |
| 376 | Supply, installation, testing and commissioning of 1200 mm sweep, one star, ceiling fan suitable for 230 V, 50 Hz, single phase AC supply, incl. necessary connections etc. complete as required (Atomberg/Orient/USHA/Havells/Crompton/Anchor) |
| 377 | Supply, installation, testing and commissioning of flood light 50 W (warm white), epoxy powder coated die-cast aluminium housing (LM24), heat sink, PG9 gland, loop-in/loop-out, class 1, IP66, IK07, high power LEDs, built-in potted IP67 LED driver with APFC, low THD, toughened glass, secondary lens, OCP, OVP, surge protection up to 10 kV with built-in SPD, test as per IS 15885 Part-2/Sec 13, IEC60598-1 (Philips/Havells/Wipro/Crompton make). Includes angle iron stand of suitable size grouted in cement concrete with hold fasteners, complete |
| 378 | Supply and fixing of 6 amp/250 V A.C. fan dimmer, step type, 2 module, with cover plate (Anchor Roma Plus/SSK NV/ABB/Schneider/Legrand or equivalent make) |
| 379 | S/Laying (partly overhead/partly underground), testing and commissioning of XLPE aluminium armoured cable 650 V/1100 V grade as per IS 7098 (Part 1) 1988 with upto date amendments (Havells/Eq. standard make) as directed by Engineer In-charge and making end termination with brass compression gland and aluminium lugs of required size: |
| 380 | 25 sq.mm 2 core (armoured) |
| 381 | Supply, fixing, testing and commissioning of suitable size 63A/100A connector |
| 382 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit, then embedding 2.5 mtr. long GI earthing electrode, 60 mm dia., connecting the electrode with main control board by 10 SWG copper wire with 1/2\\" dia. full thread brass nut and bolts and washers, refilling the pit with chemical compound |
| 383 | Supply, installation, testing and commissioning of minimum 1625 VA power inverter (pure sine wave type) having generator compatible & provided and fitted with 2 no. 12V, 180 Ah tall tubular batteries of Exide/Microtech/Luminous make and PVC trolley for resting/housing of batteries. Includes terminal connections of batteries, input/output leads of required size and length, carriage and applicable taxes |
| 384 | (Kalki Temple) (Electric part) |
| 385 | Wiring for light point/fan point/exhaust fan point/call bell point with 2x1.5 sq.mm FRLS PVC insulated copper conductor, 1100 V grade wires, complete with all accessories (Havells/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK or eq.), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit), with modular switch (Legrand/SSK/Schneider/Crabtree/Athena/ABB), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC copper conductor, as required. - Group-A |
| 386 | Wiring for light/power plug with 2x4 sq.mm + 1x4 sq.mm earth wire, FRLS PVC insulated copper conductor (Havell/Polycab/Fenolex/Anchor/SSK or equivalent as directed by Engineer In-charge), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit) |
| 387 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incl. providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable GI box, connections etc. as required (Legrand/SSK/Schneider/Crabtree/Athena/ABB make) |
| 388 | Wiring for lighting circuits/inverter circuits/6-10 amp power plug with 2x2.5 sq.mm FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor/SSK make), single core cable in surface/recessed medium class PVC conduit (incl. cost of conduit) along with 1 No. 2.5 sq.mm FRLS PVC insulated copper conductor for loop earthing as required |
| 389 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, incl. providing and fixing 3 pin 5-10 A modular socket outlet and 5-10 A modular switch, connections etc. as required (for light plugs in non-residential buildings) (Legrand Mylinc/SSK NV/Schneider Livia/Crabtree/ABB/Athena make) |
| 390 | Supplying and fixing of modular switch/socket/indicator on the existing modular plate and switch box incl. connections but excluding modular plate etc. as required: i. 3 pin 5/6A socket outlet |
| 391 | Supplying and fixing of modular switch/socket/indicator on the existing modular plate and switch box incl. connections but excluding modular plate etc. as required: i. Indicator |
| 392 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR Kabel/Anchor make) as described in item no. 1, single core cable in surface/recessed medium class PVC conduit as required, incl. cost of conduit: |
| 393 | 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire (Inverter Circuit) |
| 394 | 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire (Lighting Circuit) |
| 395 | 2 X 6 sq.mm + 1 X 6 sq.mm earth wire (Lighting submain) |
| 396 | 2 X 10 sq.mm + 1 X 6 sq.mm earth wire (Heating submain) |
| 397 | S/F testing and commissioning of MCBs 10 kA of the below mentioned capacities in sub main controls, C curve (Schneider/Legrand/ABB/Havells/Siemens/L&T/Hager/BCH/SSK make or OEMs/firms holding ISO 9001 certification) as directed by Engineer In-charge: |
| 398 | 6-32 Amp SP MCB |
| 399 | 32 Amp DP MCB |
| 400 | 63 Amp DP MCB |
| 401 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates |
| 402 | Supplying and fixing Horizontal type, SPN/TPN, sheet steel MCB distribution board (Legrand/Schneider/Hager/ABB/SSK/Havells make) 240/415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted incl. earthing etc. as required (but without MCB/RCCB/Isolator): |
| 403 | 12 way, Double door |
| 404 | Supply, installation, testing and commissioning of 12 W LED surface/recess, square or round mounted light luminary, min. system lumen efficacy 100 lm/W, useful life 50000 hrs at L70, separate driver, heat sink, earthing provision, input 150V-270V, in-built surge protection 2kV, LM79 & LM80 test report from govt. approved NABL lab. Includes AMC of lighting fixtures for two years incl. replacement (Philips/Havells/Wipro/Crompton make / sample to be approved before installation) |
| 405 | Supply, installation, testing and commissioning of exhaust fan of 200-250 mm sweep suitable for wall/window mounting, complete with frame, mounting arrangement, louvers/shutter and all accessories; robust construction, heavy-duty copper motor, conforming to relevant IS (Havell/Bajaj/Crompton/USHA/Orient/Anchor or OEMs holding ISO 9001) as directed by Engineer In-charge |
| 406 | Supply, installation, testing and commissioning of 1200 mm sweep, one star, ceiling fan suitable for 230 V, 50 Hz, single phase AC supply, incl. necessary connections etc. complete as required (Atomberg/Orient/USHA/Havells/Crompton/Anchor) |
| 407 | Supply, installation, testing and commissioning of flood light 50 W (warm white), epoxy powder coated die-cast aluminium housing (LM24), heat sink, PG9 gland, loop-in/loop-out, class 1, IP66, IK07, high power LEDs, built-in potted IP67 LED driver with APFC, low THD, toughened glass, secondary lens, OCP, OVP, surge protection up to 10 kV with built-in SPD, test as per IS 15885 Part-2/Sec 13, IEC60598-1 (Philips/Havells/Wipro/Crompton make). Includes angle iron stand of suitable size grouted in cement concrete with hold fasteners, complete |
| 408 | Supply and fixing of 6 amp/250 V A.C. fan dimmer, step type, 2 module, with cover plate (Anchor Roma Plus/SSK NV/ABB/Schneider/Legrand or equivalent make) |
| 409 | S/Laying (partly overhead/partly underground), testing and commissioning of XLPE aluminium armoured cable 650 V/1100 V grade as per IS 7098 (Part 1) 1988 with upto date amendments (Havells/Eq. standard make) as directed by Engineer In-charge and making end termination with brass compression gland and aluminium lugs of required size: |
| 410 | 25 sq.mm 2 core (armoured) |
| 411 | Supply, fixing, testing and commissioning of suitable size 63A/100A connector |
| 412 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit, then embedding 2.5 mtr. long GI earthing electrode, 60 mm dia., connecting the electrode with main control board by 10 SWG copper wire with 1/2\\" dia. full thread brass nut and bolts and washers, refilling the pit with chemical compound |
| 413 | Supply, installation, testing and commissioning of minimum 1625 VA power inverter (pure sine wave type) having generator compatible & provided and fitted with 2 no. 12V, 180 Ah tall tubular batteries of Exide/Microtech/Luminous make and PVC trolley for resting/housing of batteries. Includes terminal connections of batteries, input/output leads of required size and length, carriage and applicable taxes Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender