Housing Urban and Rular Development Government Departments Closing in 0 days TDR #58495453

Tender For Special Repair & Maintenance Work Of School Building At Kendriya Vidyalaya, Pachmarhi, (M.P) (Notice No. -06 /Uppcl/Gm-5/E-Tender/2026-27 Dated: 30.10.2026)

Issued by Government Departments · Indore, Madhya Pradesh
Tender Value
3.07 Crore
Estimated cost
Bid Submission
21 Nov 2026
0 days left
EMD
6.15 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair & Maintenance Work Of School Building At Kendriya Vidyalaya, Pachmarhi, (M.P) (Notice No. -06 /Uppcl/Gm-5/E-Tender/2026-27 Dated: 30.10.2026)

BOQ

Name of Work:- SPECIAL REPAIR & MAINTENANCE WORK OF SCHOOL BUILDING AT KENDRIYA VIDYALAYA, PACHMARHI, (M.P) (Notice No. -06 /UPPCL/GM-5/E-TENDER/2026-27 Dated: 30.10.2026)
Sl. No. Item Description
1SPECIAL REPAIR & MAINTENANCE WORK OF SCHOOL BUILDING AT KENDRIYA VIDYALAYA, PACHMARHI, (M.P)
2STRUCTURE REPAIR & RETROFITTINGS
3Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
450mm average thickness
525 mm average thickness
6Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
7Bars upto 12 mm diameter
8Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge.
9Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer-in-Charge
10Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument.
1125mm thick in Grade M 25 with cement content not less than 330 kg per cum
1250mm thick in Grade M 25 with cement content not less than 330 kg per cum
13Re-Baring of MS bar 10 mm dia with Fisher Chemical including drilling of hole, cleaning, and fixing of bar complete as per direction of Engineer-in-Charge.
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
15Thermo-Mechanically Treated bars of grade Fe-500D or more.
16Repairs to plaster with Dr. fixit micro-Concrete for (column/beam/slab). The procedure to operate this item is as follows :- i.) Remove all loose particle as per required ii.) Apply Dr. fixit Rust Remover 1st layer after 30-60 minutes again apply 2nd coat iii.) Apply dr. fixit zinc primer 1 layer iv.) Apply Dr. fixit micro-Concrete 5-25 mm
17Expansion Joint Treatment
18Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).
19Floor Joint of 100 mm gap
20Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).
21Wall Joint of 100 mm gap
22Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.)
23Roof Joint of 100 mm gap
24REPAIRS TO ROOF
25Scraping, stripping, and removing existing old/damaged bituminized treatment, APP membrane, tar felt, or loose mortar screed down to the bare, sound RCC roof slab surface by mechanical/manual means; wire brushing, high-pressure water washing to clean dust, algae, and loose particles; routing out cracks in V-groove (15X15) and filling with polymer-modified mortar; including disposal of all dismantled unserviceable debris/malba to designated municipal dumping ground with all lifts and lead up to 50 m complete as per direction of Engineer-in-Charge.
26Repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy based dampgaurd (Dr. Fixit Make), including cutting the area of plaster in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)
27Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
28Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
29Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
30Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
31Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
32G.S. Sheet
33Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
34In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
35Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
360.80 mm thick with zinc coating not less than 275 gm/m2
37Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
38Providing and fixing of 40 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 (1 cement : 3 coarse sand).
391.00 mm thick with zinc coating not less than 275 gm/m2
40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
41Two or more coats on new work
42REPAIRS TO TOILETS
43Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
44For thickness of tiles 10 mm to 25 mm
45Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
46Granite Stone of approved shade
47Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, tile levelling clips and wedges.
48Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Minimum Size 300x450)
49Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
50Providing and filling of AAC Lightweight Broken Blocks in sunken portions.
51REPAIR TO PLASTER & PLINTH PROTECTION
52Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
53Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
54Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
55Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
56Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
57Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
58Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.
59With cement mortar 1:4 (1cement: 4 coarse sand)
6012mm cement plaster of mix :
611:6 (1 cement : 6 course sand)
6215mm cement plaster on rough side of single or half brick wall of mix :
631:6 (1 cement : 6 course sand)
646mm cement plaster to ceiling of mix :
651:3 (1 cement : 3 fine sand)
66Cement Plaster 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6720 mm cement plaster
68Extra for providing and mixing water proofing material in cement per bag of plaster work in proportion recommended by the manufacturers.
69Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
70Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
71New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
72Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete, as per manufacturer's specification.
73Old work (one or more coats)
74Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
75New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
76Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
77Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cement paint surface
78REPAIRS TO DOOR/WINDOWS
79Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
80Of area 3 sq. metres and below
81Of area 3 sq. metres and above
82Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
83Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
84Renewal of old putty of glass panes (length)
85Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
8635 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
87Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)
88Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square
89Providing and fixing decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS:2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
90Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete
91Fixed to steel windows by welding
92Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete
93300 mm weighing not less than 200gms.
94250 mm weighing not less than 150gms.
95Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
96Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
97Twin rubber stopper
98Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm
99Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete
100300 x 10mm
101200 x 10mm
102Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm.
103125 mm
104WPC DOORS FOR TOILETS
105Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.(M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
106Frame size 55 x 125 mm
107Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
10835 mm thick
109Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
110Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 125x64x2.50 mm
111FACTORY MADE ALUMINIUM WINDOWS
112System Aluminium Factory made Double Rebate Windows with Grill and Mesh. Providing and fixing of Double rebate openable windows & ventilators made of High-performance factory-made system Aluminium windows with Akzonobel powder coating of 60-70 microns (Any RAL Colour). The Extruded Aluminum section should be made from aluminium of grade - 6063 T6. Section for Outer frame should be of 114.5mm x 40mm, Glass shutter frame shall be of 70mm x 40mm, Mesh shutter frame shall be of 70mm x 40mm, 24mm thick Double Glazed Glass beading shall be of 15mm x 18mm x 32mm. Stainless Steel Wire Mesh shall be used in Wire mesh Shutters. 10mm Sq bar M.S. Grill/Guard bar with 150mm c/c shall be fixed in between glass & mesh shutter. All frame corners shall be joined/assembled using self-locating corner cleats (No screwing at corners shall be allowed). System should qualify Wind load resistance as per BSEN 12210 - 2kpa, water tightness as per BSEN 12208 - 200 pa & Air tightness as per BSEN 12207 - Class 2. All Hardware shall be used from a reputed brand, weather silicon shall be used for filling the gap between window opening & window Frame complete in all respect including all taxes. [Client correction: MR item (599.34 Sqm @ Rs 25,320.00 = 1,51,75,288.80 Non-DSR) replaced by DSR items 9.147A1.3 Window and 9.147C2 Ventilator below]
113Window
114Ventilator
115Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
116Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
117Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size
118Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
119Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
120Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
121In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
122Providing and fixing 18 SWG (approx. 1.20-1.22 mm dia) GI wire mesh / mosquito-type wire mesh having approximately 12 mm x 12 mm clear opening, woven from galvanised iron wire, fixed tautly within MS hollow-section frame using suitable MS/GI flat, clips, screws, welding/fasteners and necessary accessories, including cutting, fitting, fixing and making good complete as per approved drawing and direction of Engineer-in-Charge.
123Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with
1244.0 mm thick glass panes
125Applying priming coat :
126With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
127With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
128Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
129Two or more coats on new work
130Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
131One or more coats on old work
132REPAIRS TO FLOORING
133Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil.
134Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
135Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
136Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
137Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1381:4:8 (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size).
139Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
140Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
141Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
142For thickness of tiles 10 mm to 25 mm
143Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
14452 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc complete.
145Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile.
146Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile.
147Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
14825 mm thick
149Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
150Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size. (a) Size of Tile 600x600 mm
151Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
152Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-incharge. Size of Tile 600x600 mm
153MISCELLANEOUS
154Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead :
155Of sectional area below 40 square centimetres
156Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :s lead :
157Thickness above 10 mm up to 25 mm
158Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
159Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
160In cement mortar
161Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.
162Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
163Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
164Cement mortar 1:6 (1 cement : 6 coarse sand)
165Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 75 in superstructure above plinth level up to floor V level.
166Cement mortar 1:4 (1 cement :4 coarse sand
167Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.
168Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%.
169Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):
170Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
171SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
172Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
173W.C. pan with ISI marked white solid plastic seat and lid
174Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
175White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
176Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge
177Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required
178Range of three squatting plates with 10 litre P.V.C. automatic flushing cistern
179Range of four squatting plates with 10 litre P.V.C. automatic flushing cistern
180Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS 8931
18115 mm nominal bore
182Providing & fixing wash basin with C.I. brackets, C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required.
183White Vitreous China Wash basin size 630x450mm with a single 15 mm C.P.brass pillar taps
184Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge
185Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
186Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required
187Kitchen sink with drain board
188510X1040mm bowl depth 200mm
189Sink without drain board
190610X510 mm bowl depth 200mm
191Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete
192Flexible pipe
19332 mm dia
19440 mm dia
195Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
196Providing and fixing toilet paper holder :
197C.P. brass
198Providing and fixing G.I. soil / waste pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc
19932 mm dia. nominal bore
20040 mm dia. nominal bore
20150 mm dia. nominal bore
202Providing and fixing 125 mm dia S/S grating (with or without hole)for floor or Nahani trap
203Providing & fixing towel Ring Round from wall face with concealed fittings arrangement of approved quality with all complete with all necessary accessories
204Providing & Fixing water cooler with stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the engineer in charge
205Providing & fixing 692 mm long stanless steel Grab bar fixed from wall face with concealed fittings arrangement of approved quality with all complete
206Providing and fixing urinal partition of size 90x320x720 mm deep, including cutting and making good the wall wherever required
207Providing and Fixing CP brass bib cock of approved quality conforming to IS 8931
20815 mm nominal bore
209Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms
21015 mm nominal bore
211Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge
212a) 15 mm nominal dia
213Providing and fixing CP Brass shower rose with 15 or 20 mm inlet
214100 mm diameter
215Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
21615 mm nominal bore
217Providing and fixing unplasticised PVC connection pipe with brass unions
21845 cm length
21915 mm nominal bore
220Providing & Fixing wall mounted round shape stainless steel soap dish holder with 2 nos cp brass wall flanges & CP brass screws complete in all respect as per direction of engineer - in - charge
221SUB HEAD - II : DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
222Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design
223180x150 mm size P type
224With fly ash bricks (non modular) bricks of class designation 7.5
225Providing and Fixing on wall face Unplasticised rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion
226Soil, Waste and Rain Water Pipes
227Single Socketed Pipes
22875 mm diameter
229110 mm diameter
230Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
231150 mm dia. R.C.C. pipe
232250 mm dia. R.C.C. pipe
233Supplying and laying of following size DWC HDPE (SN-8) pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16098, Part II complete with fitting and cutting, jointing etc direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc ,complete as required
234150mm Internal Diameter
235200 mm Internal Diameter
236Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) with RCC top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size ), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size ) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm norminal size),and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm norminal size) finished with a floating coat of neat cement complete as per standard design
237inside size 90x80 cms and 45 cms deep including CI cover with frame ( light duty ) 455x610 mm internal dimensions total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg & weight of frame 15 kg )
238with common brunt clay FPS ( non modular ) bricks of class designation 7.5
239Extra depth for manhole 90x80 cm
240With FPS bricks class designation 7.5
241Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand),in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded staone aggregate 40 mm norminal size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal size) finished with a floating coat of neat cement all complete as per standard design.
242Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top (as above) - depth 0.91 m
243With Common Burnt clay FPS ( non modular ) bricks of class designation 7.5
244Extra depth for Circular Type manhole 0.91 m internal dia ( at bottom ) beyond 0.91 m to 1.67 m
245With common burnt clay FPS ( non modular ) bricks of class designation 7.5
246Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing,including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design
247Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design
248With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
249Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
250Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams
251Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
252Stone ware Spout
253Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion
254Coupler
25575 mm diameter
256110 mm diameter
257Single Push Fit Coupler
25875 mm diameter
259110 mm diameter
260Single Tee with door
26175x75x75 mm
262110x110x110 mm
263Single Tee without door
26475x75x75 mm
265110x110x110 mm
266Bend 87.5 degree
26775 mm bend
268110 mm bend
269Shoe ( Plain )
27075 mm Shoe
271110 mm Shoe
272Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to PP trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge
273Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge
274100 mm diameter Pipe
275SUB HEAD - III : WATER SUPPLY
276Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge
277Internal work - Exposed on wall.
27815 mm dia pipes
27920 mm dia pipes
28025 mm dia pipes
28132 mm dia pipes
28240 mm dia pipes
28350 mm dia pipes
284Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
28515 mm dia pipes
28620 mm dia pipes
28725 mm dia Pipes
288Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge
28965 mm nominal dia Pipes
29080 mm nominal dia Pipes
291Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
29220 mm dia. nominal bore
29325 mm dia. nominal bore
29432 mm dia. nominal bore
29540 mm dia. nominal bore
296Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
297Supply ,Erection , Testing & Commissioning of Automatic water level control panel & related accessories for pumping automation with consisting of automatic water level controller , level sensor with stainless steel probe, motorized butterfly valve, motorized valve controller with complete in all respect
298upto 50 mm dia. nominal bore
299Providing and fixing Air realease valve of quality & make as approved by Engineer in charge
300upto 50 mm dia. nominal bore
301Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design
302With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
303Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
30465 mm dia
30580 mm dia
306Cutting holes up to 30x30 cm in walls including making good the same:
307With common burnt clay F.P.S. (non modular) bricks
308Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof
309Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc
310Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately)
311Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5
312Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
313SUB HEAD - IV : DISMANTLING WORK
314Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead
31575 to 80 mm dia pipe
316Dismanling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge
31715 mm to 40 mm nominal bore
318Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge
319Up to 150 mm diameter
320Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge
321Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap
322Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge
323Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead
324Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres
325Up to 150 mm diameter
326Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge :
327Rectangular manhole 90x80 cm and 45 cm deep
328SUB HEAD - I - CIRCUIT CUM POINT WIRING
329SWITCH CONTROL LIGHT POINTS
330Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
331Group A
332Group B
333Group C
334Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
335Group A
336Group B
337Group C
338MCB CONTROL LIGHT POINTS
339Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed steel 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points).
340Primary point controlled by one MCB.
341Same as item above but Secondary point, i.e. Points to be looped with Primary point with 1.5 sqmm FRLS/HFFR wire and Point wiring.
342Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
343Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
3442 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3452 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3462 X 6 sq. mm + 1 X 6 sq. mm earth wire
3472 x 10 sq. mm + 1 x 6 sq.mm earth wire
3484 X 10 sq. mm + 2 X 6 sq. mm earth wire
3494 X 16 sq. mm + 2 X 6 sq. mm earth wire
350Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
351Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
352Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
353Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
354Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
355Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
356Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
357Telephone socket outlet
358TV antenna socket outlet
359Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3601 or 2 Module (75mmX75mm)
3616 module (78mm X 205 mm X 50 mm)
362Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
36325 mm
36432 mm
365SUBHEAD - II - FITTINGS & FIXTURES
366Supply, Installation, Testing and Commissioning of LED Bulkhead Light
367Supply, Installation, Testing and Commissioning of LED Mirror Light
368Supply, Installation, Testing and Commissioning of Wall Mounted LED Bracket Lights.
369Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, internal surge protection of 2.5 KV, THD < 10%, P.F. >0.95, IP20, CRI >80, UGR < 19, flicker free, life time minimum 50000 burning hours with 70% lumen maintained, CCT 3000/4000/5700/6500 K, BIS standard & T.C., OEM NABL lab, complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficacy >=120 <135 lm/Watt, LM79 & LM80 test report. Powder coated die cast /Extruded aluminium body including trim with aluminium reflector. LED Down lighter (COB Type) following wattage. [Full specification as per original PDF page 58]
3708-10 Watt
37112-15 Watt
37218 Watt
373Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq. 50/60 hz, internal surge protection of 2.5 KV, THD < 10%, P.F. >0.95, IP20, CRI >80, flicker free, minimum 50000 burning hours with 70% lumen maintained, CCT 3000/4000/5700/6500 K, BIS standard & T.C., complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt. Powder coated die cast /Extruded aluminium body (Thickness > 1.20 mm) Batten light. [Full specification as per original PDF page 58]
37418-22 Watt
375Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, internal surge protection of 2.5 KV, THD < 10%, P.F. >0.95, IP20, CRI >80, UGR < 19, flicker free, minimum 50000 burning hours with 70% lumen maintained, CCT 3000/4000/5700/6500 K, BIS standard & T.C., complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt. Powder coated die cast /Extruded aluminium body (Thickness > 1.20 mm). LED Panel light 2x2 ft. [Full specification as per original PDF page 59]
37636 Watt
377Brush Less Direct Current (BLDC) Fan with Remote: Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
378900mm, service value >= 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum)
3791200mm, service value >= 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
3801400mm, service value >= 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
381Supply, Installation, Testing and Commissioning of 250 mm dia Domestic Exhaust Fan.
382SUBHEAD - III - DISTRIBUTION BOARDS
383Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
3846 way, Double door
3858 way, Double door
38612 way, Double door
387Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
3884 way (4 + 12), Double door
3896 way (4 + 18), Double door
3908 way (4 + 24), Double door
391Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required).
39212 way (4 + 36), Double door
393Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
394Single Pole
395Single Pole and Neutral
396Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
397Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
398Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
399Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
400SUBHEAD - IV- UPS SYSTEM
401UPS SYSTEM:- Online UPS- Input supply: Three Phase, Output supply: Three Phase
402Supplying, installation, Testing & Commissioning of of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swappable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of moduels requird for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc.
403UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect (ITHD) on the input grid shall be < 5% at 50 %load.
404(The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output, Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for IOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED ) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED). h) Statistical Data. i) Modes of operation. j) Audible Alarms. The UPS should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc.
40520KVA (Each Power module shall be < 10 KVA)
406SUBHEAD -VIII -LIGHTNING CONDUCTOR
407Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
408Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
409Jointing copper / G.I. tape (with another copper/ G.I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
410Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
411Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
412Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
413Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
414Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set
415Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
416Dismantling of Existing all Lights wiring,fixtures, 15/16, 5/6 A modular socket outlet , connections etc. Distribution D.B & Conduit Pipes, other ELV Work including CCTV, Data Structure, telephone system etc. as per site required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58495453
AUTHORITY Government Departments
TENDER VALUE 3.07 Crore
LAST DATE 21-11-2026
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Tender for Special Repair & Maintenance Work Of School Building At Kendriya Vidyalaya, Pachmarhi, (M.P) (Notice No. -06 /Uppcl/Gm-5/E-Tender/2026-27 Dated: 30.10.2026)
Basic Detail
Tender No 06/UPPCL/GM-5/E-TENDER/2026-27 Dated-30.10.2026
Bidding Type Tender
Location
City Indore
State Madhya Pradesh
Key Dates
Publish Date 12 Nov 2026
Submission Date 21 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 3.07 Crore
Tender Fee 17700
EMD 6.15 Lakhs
Exemption Not Available
Document List
009b923a-1e71-420f-ae80-ae3fb7b1ee56.html
BIDDOC06.pdf
BOQ_2291478.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
html

009b923a-1e71-420f-ae80-ae3fb7b1ee56.html

pdf

BIDDOC06.pdf

xls

BOQ_2291478.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender