Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 20 days TDR #58495065

Tender For Composite Works Cng Stations At Dakshin Kannada & Bastar Gas - Electrical, Mechanical, Structural & Civil Works (Dakshin Kannada)

Issued by Boards / Undertakings / PSU · Ghaziabad, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Dec 2026
20 days left
EMD
18.40 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Composite Works Cng Stations At Dakshin Kannada & Bastar Gas - Electrical, Mechanical, Structural & Civil Works (Dakshin Kannada)

BOQ

Name of Work:- COMPOSITE WORKS CNG STATIONS AT DAKSHIN KANNADA & BASTAR GAs - ELECTRICAL, MECHANICAL, STRUCTURAL & CIVIL WORKS (DAKSHIN KANNADA)
Sl. No. Item Description
1DAKSHIN KANNADA
2PART - I : Electrical Works
3Electrical Works Supply
4Supply including packing and forwarding, transportation, delivery at storage to site 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
5Supply including packing and forwarding, transportation, delivery at storage to site 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
6Supply of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make.
7Supply of Switchboards
8Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :
9415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification.
10Single In-comer of 125 Amp (with Single phase preventer) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.
11Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.
12Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel.
13Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C, S/C & E/F RELASE) for UPS and Static Bypass.
14Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
15Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
16415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. & as per standard Specification.
17Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
18Outgoing with 3 nos. 63 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etc ii) Air Compressor iii) APFC Panel
19Outgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.
20Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
21Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
22415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification .
23Single In-comer 63A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
24Outgoing with 2 nos. 32 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)Spare
25Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
26Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
27Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification
28Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
29Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
30Supply including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
31Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent)
32Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent)
33Supply of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.
34Design, engineering, supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
35Earth Pits- GI PIPE Electrode (size 3.0 m long, 65NB Class-B) with 6 mm thick chequered plate cover
36Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
37GI Strip (50X6) mm
38GI Strip (25X3) mm
39Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.
40GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
41Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
42Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
433.5x 120 mm2 A2XFY
443.5x 95 mm2 A2XFY
453.5x 50 mm2 A2XFY
463.5x 35 mm2 A2XFY
474x 25 mm2 A2XFY
484x10 mm2 2XWY
494x 6 mm2 2XWY
504x 2.5 mm2 2XWY
51Supply of following sizes of HDPE Pipe as per approved drawings and directions of Engineer-In-Charge.
5250 mm NB
5380 mm NB
54100 mm NB
55150 mm NB
56Supply of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
57Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent).
58Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent).
59Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
60Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
6120 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
62Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
63Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
64SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
65Design, manufacture, testing at works, supply, storage, transportation to site of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
66Supply of following including necessary clamp, bolts, rawl plugs etc.
67Shock hazard charts
68First Aid Boxes
69Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate.
70Caution boards
71Single Line Diagram in teak wood wall cabinet with glass door
72Wooden key box with glass cover
73Supply of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652 and Indian Electricity Rules.
74Supply of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
75150mm wide
76300mm wide
77Supply of 2 Coats of Primer Painted & Fabricated support structure.
78UPS SYSTEM
79Design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage ,inspection, packing, forwarding, delivery including commissioning spares as required of UPS systems as per specification, block diagram and following rating:
803KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel.
81230 V, 36 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories.
82Erection Material
83Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
84For COCO/RO/OLS/MS/DBS/DCU
85Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
86For COCO/RO/OLS/MS/DBS/DCU
87Supply of required material for construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
88500X500(of inside clearance)X 600(Depth)
89750X750(of inside clearance)X800(Depth)
901000X1000(of inside clearance)X1000(Depth)
91ELECTRICAL WORKS - ERECTION
92Installation, Testing and Commissioning of 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
93Installation, Testing and Commissioning of 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
94Installation, Testing and Commissioning of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make.
95STATUTORY APPROVALS, PERMISSIONS : Coordination & Liasioning with statutory authorities for obtaining Licence/NOC/ Approval /Permission with statutory authorities for GAIL Gas as required for setting of CNG stations .However, all the statutory payment required for such Licence/NOC/ Approval /Permission shall be reimbursed by GGL at actuals against production of documentary evidence and this statutory payment at actuals shall be over and above the coordination and liasioning charges in the items below. The bidder shall note that the rates for the items are inclusive of all expenses (except for statutory payments which shall be reimbursed on actuals) for carrying out the liasioning and coordination work till obtaining the final Licence/NOC/ Approval /Permission.To submit application on behalf of Gail gas to SEB for the incoming power Installation, Testing and Commissioning along with all the required documents, obtaining NOC from SEB for final charging, obtaining drawing approval from CEIG before commencemnt of work and obtaining safety & comissionming approval of Transformer by CEIG and SEB.The price shall be inclusive of Application Fee,liaisioning, Local Transport, Incidental travelling etc, and all other expenses.
96Installation, Testing and Commissioning of Switchboards
97Design, engineering, manufacture, shop testing, Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :
98415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification.
99Single In-comer of 125 Amp(with Single phase preventer ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.
100Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.
101Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel.
102Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C, S/C & E/F RELASE) for UPS and Static Bypass.
103Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
104Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
105415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification .
106Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
107Outgoing with 3 nos. 63 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etc ii) Air Compressor iii) APFC Panel
108Outgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.
109Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
110Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
111415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/23VF/05/E9/E/1081D & as per standard Specification .
112Single In-comer 63A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
113Outgoing with 2 nos. 32 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)Spare
114Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
115Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
116Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification
117Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
118Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
119Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
120Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent)
121Installation, Testing and Commissioning of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent)
122Installation, Testing and Commissioning of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.
123Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
124Earth Pits- GI PIPE Electrode (size 3.0 m long, 65NB Class-B) with 6 mm thick chequered plate cover
125Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
126GI Strip (50X6) mm
127GI Strip (25X3) mm
128Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.
129Installation of GI lightning rod 25 mm dia. 1800 mm long including all labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
130Installation of Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
131Installation, Testing and Commissioning, Laying including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
1323.5x 120 mm2 A2XFY
1333.5x 95 mm2 A2XFY
1343.5x 35 mm2 A2XFY
1353.5x 50 mm2 A2XFY
1364x 25 mm2 A2XFY
1374x10 mm2 2XWY
1384x 6 mm2 2XWY
1394x 2.5 mm2 2XWY
140Installation, Testing and Commissioning of following sizes of HDPE Pipe
14150 mm NB
14280 mm NB
143100 mm NB
144150 mm NB
145Installation, Testing and Commissioning of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
146Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent).
147Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent).
148Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
149Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
15020 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
151Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
152Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
153SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
154Erection,testing and commissioning of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
155Installation, Testing and Commissioning of following including necessary clamp, bolts, rawl plugs etc.
156Shock hazard charts
157First Aid Boxes
158Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate.
159Caution boards
160Single Line Diagram in teak wood wall cabinet with glass door
161Wooden key box with glass cover
162Installation and laying of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652 and Indian Electricity Rules.
163Erection testing and commissioning of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
164150mm wide
165300mm wide
166Painting work of 2 Coats of Primer Painted & Fabricated support structure.
167UPS SYSTEM
168Installation, Testing and Commissioning, packing, forwarding, delivery by equipment supplier at site including commissioning spares as required of UPS systems as per specification, datasheet, block diagram of the following rating :
1693KVA, 50 Hz, Industrial Type,single UPS system suitable for input Power Installation, Testing and Commissioning voltage of 320V-460V- TPN (184-265V/Ph) , output 230 V +/- 1%, AC with Bypass Installation, Testing and Commissioning, Battery Bank , and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 14 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). Charger rating shall not be less than 6.5 kW. All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system).
170230V, 36 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories.
171Erection Material
172Installation,welding and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, Installation, Testing and Commissioning of necessary anchor bolts and grouting etc Installation, Testing and Commissioning of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including Installation, Testing and Commissioning of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
173For COCO/RO/OLS/MS/DBS/DCU
174Installation, Termination and Commissioning of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
175For COCO/RO/OLS/MS/DBS/DCU
176Civil Construction of required material for the construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
177500X500(of inside clearance)X 600(Depth)
178750X750(of inside clearance)X800(Depth)
1791000X1000(of inside clearance)X1000(Depth)
180MECHANICAL & TUBING WORKS
181SS TUBE LAYING & TESTING
182Laying of SS Tubes with PVC tube clamp, Hydro testing at 375 bar and commissioning of SS tubes along with fittings, hose, mass flow meter and valves as given below and as per Technical Specification and scope of work including handling, lifting, transportation from stores to location of CNG stations.
1831”OD X 0.120” min Wall thk. SS Tube
184¾”OD X 0.095” min Wall thk. SS Tube
185½”OD X 0.083” min Wall thk. SS Tube
186Supply of SS Tubes as per Technical Specification
1871”OD X 0.095” min Wall thk.,Material SS316 SS Tube (Refer TS)
188¾”OD X 0.095” min Wall thk.,Material SS316 SS Tube (Refer TS)
189½”OD X 0.083” min Wall thk.,Material SS316 SS Tube (Refer TS)
190Note: Quantities beyond mentioned quantities may be provided as free issue.
191Supply of SS Fittings
192Union
193Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
194Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
195Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
196Reducing Union
197Tube OD 3/4\\" x Tube OD 1/2\\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
198Tube OD 1\\" x Tube OD ¾\\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
199Equal Tee
200Size:1\\" OD x 1\\" OD x 1\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
201Size:3/4\\" OD x 3/4\\" OD x 3/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
202Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
203¾ \\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
204½\\" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
2051\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
206Front Ferrule
2073/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
208½\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
2091\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
210Back Ferrule
2113/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
212½\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
2131\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
214Size : ¾\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
215Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
216Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
217Size : ¾\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
218Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
219Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
220Cross
2213/4\\" OD X 3/4” OD X 3/4\\" OD X 3/4\\" OD Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
222Quick Connect Body & Stem
223End connection:½\\" Tube OD, for stem & ½”NPT (F) for body Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F
224Reducing Union Tee
225¾\\" OD x ½\\" OD x ¾\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
226Tube End Connection
227½” Tube End & ¾” OD with Ferrule Fitting, SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
228Male Connector
229Size ¼” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
230Size 1/2” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
2311/2\\" NPT male to 3/4\\" OD Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
232Supply of SS Ball Valves conforming to Technical Specification for SS Ball Valves of following sizes, specifications as indicated below :
2332-Way Floating Normal Bore Ball Valve ¾\\"
2343-Way Trunnion Mounted, Reducer Bore Ball Valve ½\\" OD end Connection and ¼” NPT (F) bottom end connection
2352-Way Floating Normal Bore Ball Valve 1/2\\"
236SUPPLY OF HIGH PRESSURE CNG HOSE ASSEMBLY (CONDUCTIVE CORE THERMOPLASTIC HOSE ASSEMBLY)
237Design, Manufacture, testing, Loading , Supply,Transportation & Unloading at GGL stores of 1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away coupling along with Quick connect body & stem (End connection:½\\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\\" NPT(M) and other end of the hose shall be 3/4\\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.
238ERECTION OF MECH. EQUIPMENT
239Handling (including lifting and transportation from Client's store within GA to CNG stations) and erecting in position, the following equipment either on the foundation or on roof at ~ 3 to 4 m above ground level. Contractor's scope includes supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc.. Scope also includes supply of all lifting tools / necessary accessories and hiring of cranes for same.
240Type-I; Cascade 4500/3000 L water capacity. Erection at + 3.0 to 4.0 M level
241Type-I; Cascade 4500/3000 L water capacity, Erection at + Ground level
242Type-IV; Cascade 8800 Water capapcity, Erection at 0.0 level
243Decompression unit-The item also includes supervision of OEM required for installation and commissioning of the equipment at station.
244DISMANTLING, SHIFTING, RE-INSTALLATION & COMMISSIONING OF CNG Decompression unit and Conversion of DBS to Online
245Dismantling,disconnecting cables,earthing, SS tube,pipe, removal of Decompression unit/Daughter Booster Compressor along with related accessories from one Station within GA and shifting/transportation including loading, unloading and then installation, erection, testing and commissioning of same equipment along with accessories, cables at other station within GANote: The above item also includes breaking/dismantling of foundation if required, supply of pipes/cables ,pipe fittings, foundation bolts, supervision of OEM required for installation and commissioning of the equipment at other station.
246Handling including lifting and transportation of dispenser frame from Client's store within city to CNG stations and Erection at + Ground Level
247The quantities given above against individual items are indicative and shall not be considered to be binding. The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge. The unit rate shall be operated to work out the final payment due to Contractor.
248ERECTION OF MECH. EQUIPMENT
249Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC
250Fire fighting Equipments
251Stored Pressure Type DCP -9 Kg confirming to IS 15683 and as per TS
252DCP -75 Kg confirming to IS 10658 and as per TS
253CO2 – 4.5 Kg confirming to IS 15683 and as per TS
254Sand Bucket Stand with 4 Nos. Bucket and as per TS
255Design, manufacture, assembly, testing & supply as well as installation, testing and commissioning of LCV Filling post consisting of the following.-4” Pressure Gauge for pressure monitoring of CNG,-1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away coupling along with Quick connect body & stem (End connection:½\\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\\" NPT(M) and other end of the hose shall be 3/4\\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.-3-Way Trunnion Mounted, Reducer Bore Ball Valve ½\\" OD end Connection and ¼” NPT (F) bottom end connection-2-Way Floating Normal Bore Ball Valve ¾\\"-Necessary SS tubing of sizes 3/4\\"OD and 1/2\\"OD, tube fittings-Vent tube-Required Structural frame and tube supports shall be payable through Structural SOR
256STEEL STRUCTURAL WORKS
257Structure Steel Works for Miscellaneous Structures like Grating , Handrails , Hoardings etc
258Supplying, Fabricating & Erecting in position steel structures fabricated out of MS Girders, channels, Tees, angle, flats, plate, square hollow sections pipes etc. conforming to IS:2062 and/or from pipes conforming to IS:1161 for structural purpose for cascade supporting structure, loading/unloading platform, Gratings for platform, catladder,handrails, hoardings for sinages,Lcv stand, etc. of any size/dia for required design including cutting, welding, bolting, hoisting, fixing in position, including application of one coat of primer at shop and second coat of primer at site after erection and two coats of finishing paint at site .The work is to be completed in all respect as per specification ,scope of work, detailed construction drawings and directions of the Engineer-in-charge.
259[ Rate to include cost of all labour, nut, bolts, tools, tackles, hire charges royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
260Providing and fixing Fencing Gates
261Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge.
2624m Wide x 2.1m High
2632m Wide x 2.1m High
264Providing and Fixing 6 O/P Chequered Plate Covers
265Providing and fixing chequered plate in approved panel or over steel structure including cutting, welding, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved steel primer etc complete as per scope detailed drawings , technical specifications and directions of the Engineer-In-Charge.
266[Rate to include cost of all labour, nut, bolts, stiffening sections, bars tools, tackles, hire charges, royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
267Providing and fixing Fencing Structure
268Supplying, fabricating & fixing steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including applying two coats of approved quality of synthetic enamel paint over a priming coat of in approved shade including supply of all raw materials, bolts, electrodes, transportation, including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per enclosed drawing, technical specifications,scope of works and directions of the Engineer-In-Charge.
269Fencing height 2.1m
270CIVIL WORKS
271Site clerance and earth Work
272Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the Engineer In Charge outside the premises to any place within GA designated by the local authority from site by mechanical transport.Item also include cutting and removing of bushes /tress upto 30cm girth (to be measured at 1.0m above ground) etc. (Approval of location of disposal from local authority is in scope of contractor.)
273All kinds of soil
274Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.)
275All kinds of soil
276Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.)
277Ordinary rock
278Felling of trees of the girth (measured at a height 1 m above ground level ) including cutting of trunks and branches , removing the roots and stacking of serviceable materials and disposal unserviceable material.
279a) beyond 30 cm Girth upto and including 60 cm girth
280b) Beyond 60 cm girth upto and including 120 cm girth
281c) Beyond 120 cm girth upto and including 240 cm girth
282d) Beyond 240 cm girth
283Earthwork in excavation and backfilling in layer of 200mm for foundations of buildings, basements, pipe supports, equipments as well as for manholes, plinth, tunnels, trenches for pipes & sewers & storm water drains, culverts etc., in ordinary and hard soils in both dry and wet conditions including pumping and bailing out surface and subsoil water (dewatering), shoring, strutting, slush removal at all heights and depths as per drawing and specifications wherever required , and backfilling in foundation pits and other places with excavated suitable surplus earth, including reclaiming from other soil heaps kept elsewhere and dressing and levelling,watering and mechanical compaction etc.,transporting surplus unserviceable soil to a place within GA and spreading in layers as per specifications or heaping up to any heights and as per the direction of Engineer Incharge. The Measurement for payment shall be for the theoretical volume only i.e., the volume of the block of the excavation having maximum bottom dimension of the foundation as per drawing.(Approval of location of disposal from local authority is in scope of contractor.)
284(The Contractor shall take into account in his rate the provision for excess excavation for necessary working space, slope etc., required for excavation and other allied works and refilling the side slopes and working space as mentioned in the specification).
285For depth upto & including 1.50 m
286For depth beyond 1.50 m and upto & including 3.00 m
287Extra FOR disposal of surplus earth beyond initial lead of 50m upto 10 KM
288Earth filling from available earth (excluding rock) under floors and other places with special compaction to achieve dry density of 95% standard proctor density including cost of excavation, reclaiming from soil heaps within work premises as per instruction of the EIC at all heights/depths, transporting, depositing, compacting and dressing, trimming complete as desired in layers not exceeding 15 cms including watering, consolidating by mechanical means as per specifications and instructions of the EIC.
289a) With available good quality earth
290Earth work in filling with good quality imported earth from approved source in the layers of 150 mm and compacted up to 95% to its MDD and any plan dimension including all testing, watering, rolling each layer with roller or wooden or steel rammers, and every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing / filling up ground depressions etc. complete in all respect as per scope of work, detailed construction drawings , as per technical specifications and directions of the Engineer-in-charge.
291CEMENT CONCRETE
292Supplying and laying plain cement concrete of the following proportions at all leads and lifts in all levelling courses under foundations, floors, pipelines, trenches, pits etc. using graded stone aggregate 20 mm max. size and down including mechanical mixing, transporting,shuttering (if required) consolidation, finishing, curing etc. complete,as per specifications, drawings and instructions of the Engineer Incharge.
293M-15 1:2:4
294M-10 1:3:6
295STEEL REINFORCEMENT
296Supplying, fabricating and fixing in position TMT steel reinforcements of grade Fe 500 at all levels and positions, all leads and lifts including the cost of transport, straightening, cutting, bending, cranking, binding, fixing, tying in position with annealed binding wire, welding provision of necessary chairs and spacers, including tying and bending dowel bars and their straightening upon deshuttering (wherever necessary) as per drawings and specifications and including cost of binding wire, labour, cover blocks in CM 1:2 etc., all complete for reinforced concrete as per specifications, drawings and instructions of the Engineer Incharge.
297a) Reinforcement conforming to Grade Fe-500 of IS : 1786-2008 ( TMT bars from SAIL /RINL/TATA STEEL/JSW )
2981. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as steel Reinforcement, binding wire and other minor construction materials, testing etc. all bye works and sundry works. 2. Chairs, Laps, Spacers, Wastage etc. shall be to contractor's account.
299Supplying and Laying of design mix,Reinforced Cement Concrete of following Grades at all depths and heights in all types of Foundations, Footings, equipment foundations,columns, pedestal,wall, lintels, ducts, beams, brackets, slabs of all shapes, sills, parapets,bands and any other works both in sub and Superstructures all complete with all bye works as per Drawings, Specification and instruction of Engineer. (The rates shall include the cost of necessary shuttering but excluding the cost of steel reinforcement)
300M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) UPTO PLINTH LEVEL
301M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) ABOVE PLINTH LEVEL
3021. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, other minor construction materials, shuttering , staging, removal of form work, testing of concrete, curing etc. except reinforcement steel with all bye works and sundry works complete. 2. Mix deisgn shall be prepared confirming to relevant IS Codes ( IS 10262, SP.23 & IS 456 Latest Codes) from NABL approved lab and the same shall be approved by EIC.
303Providing, constructing and finishing of compound wall in RCC frame structure with precast RCC wall panels of 100mm thickness mounted on in-situ RCC columns of 400mmx450mm size at an interval of 3.0 m or as specified in construction drawing and height 2m as specified as per scope of work , including plastering, coping, painting, whitewash,concertina coil, embossing of logo of the client, on all columns, finishes all complete as per technical specifications, tender drawing and direction of the Engineer-In-Charge.
3041. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, pre cast wall panels ,ISMC channel section,hard drawn steel wire fabric as per IS 1566 ,RCC M25, concertina coil, RBT , finishes, bitumen, Y angle, other minor construction materials, shuttering, staging, coping, expansion gap filling with \\"Capcell\\" armoured board of \\"Supreme\\" make or equivalent and white sealant material, plastering,painting and all other sundry works.
3052. Foundation/ sub-structure to be paid separately in respective SOR items.
3063.Reinforcement for columns and beam for superstructure shall be paid separately in respective SOR Item.
307Supplying & grouting for Foundations bolt holes/pockets for Equipments, Base plates, Anchoring etc, with cement based non shrink compound such as Shrinkomp of ACC or approved make of FOSROC/SIKA/ROFF including shuttering at all levels and as per drawings, specification and direction of Engineer in charge.
308Providing and laying roof screed with M-15 grade concrete (12 mm down graded coarse aggregate) at all leads and lifts with wooden trowel finish and required slope including mixing of water proofing compound as per manufacturer's specification, curing etc. , as per drawings and direction of Engineer Incharge.
309CC BLOCK work
310Providing and laying cement blocks (solid blocks) masonry mix ratio of 1 :1.5:3 with 200 mm thick blocks upto plinth level and super structure above plinth level up to top level of building in cement mortar 1:3 (1 cement : 3 coarse sand ).
311Upto Plinth level
312Above plinth level
313Brick work with bricks of class designation M 7.5 Grade with Mortar 1:6 (1 Cement: 6 Coarse sand) in all levels.
314Providing and fixing 100mm thick M-25 factory made RCC drain/trench cover including cost of shuttering and minimum reinforement@ 10mm dia TMT Fe-500 bars @100mm c/c bothway in two layers as per direction of Engineer In Charge.The RCC cover shall have edge protection with 100mm wide 1.6mm thick MS sheet all around alongwith 2 nos 12 mm dia bar for hook etc complete including painting of MS sheet.
315Providing and fixing 150mm thick M-25 Pre cast RCC drain/trench cover including cost of shuttering as per drawing and direction of Engineer In Charge. The RCC cover shall have edge protection with 150mm wide 1.6mm thick MS sheet all around alongwith 2 nos 16 mm dia bar for hook etc complete including painting of MS sheet. Reinforcement shall be paid in respective SOR Item.
316Providing and laying R.C.C.(M25 Grade concrete) vacuum dewatering concrete flooring with floor hardener of approved make to be sprinkeled at the rate of 5 kg/sqm before mechanical troweeling as per manufacturer's specifications including mixing, tamping mechanically, consolidating, leveling cement concrete of grade M25 in grade slab, 200/150 thick including suction drying, mechanical trowelling (power float) and finishing, curing, cutting expansion grooves and filling expansion grooves with polysulphide joint fillers complete as specified and directed including shuttering but excluding reinforcement, including doweled construction joints as per drawings.
317FINISHING
31812 mm cement internal plaster on walls of all heights at all levels in perfect line and level
31918 mm external cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:5 (1 cement : 5 fine sand) for all heights and levels in perfect line and level
320Painting with APEX/Wheathershield make exterior paint with one coat of primer and two or more coat of approved paint on new work wherever required to achieve even shade and colour for all heights and levels.
321Providing and laying paving of pre cast concrete interlocking pavers made of M30 grade concrete of 80 mm thickness of approved colour combination, pattern make, size, of compressive strength 300KG /sq cm. Paver blocks should be laid on sand cushion as required with a gap of 1.5mm between the blocks filled with sand including paving and curb gap to be filled with concrete of same grade of concrete pavers
322DISMANTLING/DEMOLISHING
323Demolishing of Cement Concrete (PCC) of all grades manually/mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead.
324Demolishing of RCC of all grades manually/ mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead.
325BASTAR
326PART - I : Electrical Works
327Electrical Works Supply
328Supply including packing and forwarding, transportation, delivery at storage to site 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
329Supply including packing and forwarding, transportation, delivery at storage to site 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
330Supply of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make.
331Supply of Switchboards
332Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :
333415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification.
334Single In-comer of 125 Amp (with Single phase preventer) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.
335Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.
336Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel.
337Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C, S/C & E/F RELASE) for UPS and Static Bypass.
338Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
339Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
340415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. & as per standard Specification.
341Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
342Outgoing with 3 nos. 63 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etc ii) Air Compressor iii) APFC Panel
343Outgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.
344Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
345Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
346415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification .
347Single In-comer 63A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
348Outgoing with 2 nos. 32 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)Spare
349Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
350Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
351Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification
352Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
353Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
354Supply including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
355Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent)
356Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent)
357Supply of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.
358Design, engineering, supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
359Earth Pits- GI PIPE Electrode (size 3.0 m long, 65NB Class-B) with 6 mm thick chequered plate cover
360Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
361GI Strip (50X6) mm
362GI Strip (25X3) mm
363Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.
364GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
365Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
366Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
3673.5x 120 mm2 A2XFY
3683.5x 95 mm2 A2XFY
3693.5x 50 mm2 A2XFY
3703.5x 35 mm2 A2XFY
3714x 25 mm2 A2XFY
3724x10 mm2 2XWY
3734x 6 mm2 2XWY
3744x 2.5 mm2 2XWY
375Supply of following sizes of HDPE Pipe as per approved drawings and directions of Engineer-In-Charge.
37650 mm NB
37780 mm NB
378100 mm NB
379150 mm NB
380Supply of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
381Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent).
382Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent).
383Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
384Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
38520 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
386Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
387Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
388SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
389Design, manufacture, testing at works, supply, storage, transportation to site of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
390Supply of following including necessary clamp, bolts, rawl plugs etc.
391Shock hazard charts
392First Aid Boxes
393Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate.
394Caution boards
395Single Line Diagram in teak wood wall cabinet with glass door
396Wooden key box with glass cover
397Supply of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652 and Indian Electricity Rules.
398Supply of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
399150mm wide
400300mm wide
401Supply of 2 Coats of Primer Painted & Fabricated support structure.
402UPS SYSTEM
403Design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage ,inspection, packing, forwarding, delivery including commissioning spares as required of UPS systems as per specification, block diagram and following rating:
4043KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel.
405230 V, 36 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories.
406Erection Material
407Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
408For COCO/RO/OLS/MS/DBS/DCU
409Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
410For COCO/RO/OLS/MS/DBS/DCU
411Supply of required material for construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
412500X500(of inside clearance)X 600(Depth)
413750X750(of inside clearance)X800(Depth)
4141000X1000(of inside clearance)X1000(Depth)
415ELECTRICAL WORKS - ERECTION
416Installation, Testing and Commissioning of 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
417Installation, Testing and Commissioning of 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
418Installation, Testing and Commissioning of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make.
419STATUTORY APPROVALS, PERMISSIONS : Coordination & Liasioning with statutory authorities for obtaining Licence/NOC/ Approval /Permission with statutory authorities for GAIL Gas as required for setting of CNG stations .However, all the statutory payment required for such Licence/NOC/ Approval /Permission shall be reimbursed by GGL at actuals against production of documentary evidence and this statutory payment at actuals shall be over and above the coordination and liasioning charges in the items below. The bidder shall note that the rates for the items are inclusive of all expenses (except for statutory payments which shall be reimbursed on actuals) for carrying out the liasioning and coordination work till obtaining the final Licence/NOC/ Approval /Permission.To submit application on behalf of Gail gas to SEB for the incoming power Installation, Testing and Commissioning along with all the required documents, obtaining NOC from SEB for final charging, obtaining drawing approval from CEIG before commencemnt of work and obtaining safety & comissionming approval of Transformer by CEIG and SEB.The price shall be inclusive of Application Fee,liaisioning, Local Transport, Incidental travelling etc, and all other expenses.
420Installation, Testing and Commissioning of Switchboards
421Design, engineering, manufacture, shop testing, Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :
422415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification.
423Single In-comer of 125 Amp(with Single phase preventer ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.
424Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.
425Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel.
426Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C, S/C & E/F RELASE) for UPS and Static Bypass.
427Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
428Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
429415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification .
430Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
431Outgoing with 3 nos. 63 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etc ii) Air Compressor iii) APFC Panel
432Outgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.
433Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
434Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
435415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/23VF/05/E9/E/1081D & as per standard Specification .
436Single In-comer 63A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
437Outgoing with 2 nos. 32 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)Spare
438Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
439Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
440Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification
441Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
442Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
443Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
444Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent)
445Installation, Testing and Commissioning of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent)
446Installation, Testing and Commissioning of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.
447Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
448Earth Pits- GI PIPE Electrode (size 3.0 m long, 65NB Class-B) with 6 mm thick chequered plate cover
449Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
450GI Strip (50X6) mm
451GI Strip (25X3) mm
452Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.
453Installation of GI lightning rod 25 mm dia. 1800 mm long including all labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
454Installation of Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
455Installation, Testing and Commissioning, Laying including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
4563.5x 120 mm2 A2XFY
4573.5x 95 mm2 A2XFY
4583.5x 35 mm2 A2XFY
4593.5x 50 mm2 A2XFY
4604x 25 mm2 A2XFY
4614x10 mm2 2XWY
4624x 6 mm2 2XWY
4634x 2.5 mm2 2XWY
464Installation, Testing and Commissioning of following sizes of HDPE Pipe
46550 mm NB
46680 mm NB
467100 mm NB
468150 mm NB
469Installation, Testing and Commissioning of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
470Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent).
471Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent).
472Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
473Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
47420 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
475Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
476Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
477SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
478Erection,testing and commissioning of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
479Installation, Testing and Commissioning of following including necessary clamp, bolts, rawl plugs etc.
480Shock hazard charts
481First Aid Boxes
482Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate.
483Caution boards
484Single Line Diagram in teak wood wall cabinet with glass door
485Wooden key box with glass cover
486Installation and laying of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652 and Indian Electricity Rules.
487Erection testing and commissioning of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
488150mm wide
489300mm wide
490Painting work of 2 Coats of Primer Painted & Fabricated support structure.
491UPS SYSTEM
492Installation, Testing and Commissioning, packing, forwarding, delivery by equipment supplier at site including commissioning spares as required of UPS systems as per specification, datasheet, block diagram of the following rating :
4933KVA, 50 Hz, Industrial Type,single UPS system suitable for input Power Installation, Testing and Commissioning voltage of 320V-460V- TPN (184-265V/Ph) , output 230 V +/- 1%, AC with Bypass Installation, Testing and Commissioning, Battery Bank , and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 14 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). Charger rating shall not be less than 6.5 kW. All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system).
494230V, 36 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories.
495Erection Material
496Installation,welding and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, Installation, Testing and Commissioning of necessary anchor bolts and grouting etc Installation, Testing and Commissioning of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including Installation, Testing and Commissioning of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
497For COCO/RO/OLS/MS/DBS/DCU
498Installation, Termination and Commissioning of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
499For COCO/RO/OLS/MS/DBS/DCU
500Civil Construction of required material for the construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
501500X500(of inside clearance)X 600(Depth)
502750X750(of inside clearance)X800(Depth)
5031000X1000(of inside clearance)X1000(Depth)
504MECHANICAL & TUBING WORKS
505SS TUBE LAYING & TESTING
506Laying of SS Tubes with PVC tube clamp, Hydro testing at 375 bar and commissioning of SS tubes along with fittings, hose, mass flow meter and valves as given below and as per Technical Specification and scope of work including handling, lifting, transportation from stores to location of CNG stations.
5071”OD X 0.120” min Wall thk. SS Tube
508¾”OD X 0.095” min Wall thk. SS Tube
509½”OD X 0.083” min Wall thk. SS Tube
510Supply of SS Tubes as per Technical Specification
5111”OD X 0.095” min Wall thk.,Material SS316 SS Tube (Refer TS)
512¾”OD X 0.095” min Wall thk.,Material SS316 SS Tube (Refer TS)
513½”OD X 0.083” min Wall thk.,Material SS316 SS Tube (Refer TS)
514Note: Quantities beyond mentioned quantities may be provided as free issue.
515Supply of SS Fittings
516Union
517Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
518Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
519Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
520Reducing Union
521Tube OD 3/4\\" x Tube OD 1/2\\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
522Tube OD 1\\" x Tube OD ¾\\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
523Equal Tee
524Size:1\\" OD x 1\\" OD x 1\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
525Size:3/4\\" OD x 3/4\\" OD x 3/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
526Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
527¾ \\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
528½\\" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
5291\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
530Front Ferrule
5313/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
532½\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
5331\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
534Back Ferrule
5353/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
536½\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
5371\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
538Size : ¾\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
539Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
540Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
541Size : ¾\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
542Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
543Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
544Cross
5453/4\\" OD X 3/4” OD X 3/4\\" OD X 3/4\\" OD Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
546Quick Connect Body & Stem
547End connection:½\\" Tube OD, for stem & ½”NPT (F) for body Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F
548Reducing Union Tee
549¾\\" OD x ½\\" OD x ¾\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
550Tube End Connection
551½” Tube End & ¾” OD with Ferrule Fitting, SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
552Male Connector
553Size ¼” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
554Size 1/2” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
5551/2\\" NPT male to 3/4\\" OD Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
556Supply of SS Ball Valves conforming to Technical Specification for SS Ball Valves of following sizes, specifications as indicated below :
5572-Way Floating Normal Bore Ball Valve ¾\\"
5583-Way Trunnion Mounted, Reducer Bore Ball Valve ½\\" OD end Connection and ¼” NPT (F) bottom end connection
5592-Way Floating Normal Bore Ball Valve 1/2\\"
560SUPPLY OF HIGH PRESSURE CNG HOSE ASSEMBLY (CONDUCTIVE CORE THERMOPLASTIC HOSE ASSEMBLY)
561Design, Manufacture, testing, Loading , Supply,Transportation & Unloading at GGL stores of 1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away coupling along with Quick connect body & stem (End connection:½\\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\\" NPT(M) and other end of the hose shall be 3/4\\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.
562ERECTION OF MECH. EQUIPMENT
563Handling (including lifting and transportation from Client's store within GA to CNG stations) and erecting in position, the following equipment either on the foundation or on roof at ~ 3 to 4 m above ground level. Contractor's scope includes supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc.. Scope also includes supply of all lifting tools / necessary accessories and hiring of cranes for same.
564Type-I; Cascade 4500/3000 L water capacity. Erection at + 3.0 to 4.0 M level
565Type-I; Cascade 4500/3000 L water capacity, Erection at + Ground level
566Type-IV; Cascade 8800 Water capapcity, Erection at 0.0 level
567Decompression unit-The item also includes supervision of OEM required for installation and commissioning of the equipment at station.
568DISMANTLING, SHIFTING, RE-INSTALLATION & COMMISSIONING OF CNG Decompression unit and Conversion of DBS to Online
569Dismantling,disconnecting cables,earthing, SS tube,pipe, removal of Decompression unit/Daughter Booster Compressor along with related accessories from one Station within GA and shifting/transportation including loading, unloading and then installation, erection, testing and commissioning of same equipment along with accessories, cables at other station within GANote: The above item also includes breaking/dismantling of foundation if required, supply of pipes/cables ,pipe fittings, foundation bolts, supervision of OEM required for installation and commissioning of the equipment at other station.
570Handling including lifting and transportation of dispenser frame from Client's store within city to CNG stations and Erection at + Ground Level
571The quantities given above against individual items are indicative and shall not be considered to be binding. The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge. The unit rate shall be operated to work out the final payment due to Contractor.
572ERECTION OF MECH. EQUIPMENT
573Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC
574Fire fighting Equipments
575Stored Pressure Type DCP -9 Kg confirming to IS 15683 and as per TS
576DCP -75 Kg confirming to IS 10658 and as per TS
577CO2 – 4.5 Kg confirming to IS 15683 and as per TS
578Sand Bucket Stand with 4 Nos. Bucket and as per TS
579Design, manufacture, assembly, testing & supply as well as installation, testing and commissioning of LCV Filling post consisting of the following.-4” Pressure Gauge for pressure monitoring of CNG,-1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away coupling along with Quick connect body & stem (End connection:½\\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\\" NPT(M) and other end of the hose shall be 3/4\\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.-3-Way Trunnion Mounted, Reducer Bore Ball Valve ½\\" OD end Connection and ¼” NPT (F) bottom end connection-2-Way Floating Normal Bore Ball Valve ¾\\"-Necessary SS tubing of sizes 3/4\\"OD and 1/2\\"OD, tube fittings-Vent tube-Required Structural frame and tube supports shall be payable through Structural SOR
580STEEL STRUCTURAL WORKS
581Structure Steel Works for Miscellaneous Structures like Grating , Handrails , Hoardings etc
582Supplying, Fabricating & Erecting in position steel structures fabricated out of MS Girders, channels, Tees, angle, flats, plate, square hollow sections pipes etc. conforming to IS:2062 and/or from pipes conforming to IS:1161 for structural purpose for cascade supporting structure, loading/unloading platform, Gratings for platform, catladder,handrails, hoardings for sinages,Lcv stand, etc. of any size/dia for required design including cutting, welding, bolting, hoisting, fixing in position, including application of one coat of primer at shop and second coat of primer at site after erection and two coats of finishing paint at site .The work is to be completed in all respect as per specification ,scope of work, detailed construction drawings and directions of the Engineer-in-charge.
583[ Rate to include cost of all labour, nut, bolts, tools, tackles, hire charges royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
584Providing and fixing Fencing Gates
585Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge.
5864m Wide x 2.1m High
5872m Wide x 2.1m High
588Providing and Fixing 6 O/P Chequered Plate Covers
589Providing and fixing chequered plate in approved panel or over steel structure including cutting, welding, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved steel primer etc complete as per scope detailed drawings , technical specifications and directions of the Engineer-In-Charge.
590[Rate to include cost of all labour, nut, bolts, stiffening sections, bars tools, tackles, hire charges, royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
591Providing and fixing Fencing Structure
592Supplying, fabricating & fixing steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including applying two coats of approved quality of synthetic enamel paint over a priming coat of in approved shade including supply of all raw materials, bolts, electrodes, transportation, including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per enclosed drawing, technical specifications,scope of works and directions of the Engineer-In-Charge.
593Fencing height 2.1m
594CIVIL WORKS
595Site clerance and earth Work
596Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the Engineer In Charge outside the premises to any place within GA designated by the local authority from site by mechanical transport.Item also include cutting and removing of bushes /tress upto 30cm girth (to be measured at 1.0m above ground) etc. (Approval of location of disposal from local authority is in scope of contractor.)
597All kinds of soil
598Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.)
599All kinds of soil
600Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.)
601Ordinary rock
602Felling of trees of the girth (measured at a height 1 m above ground level ) including cutting of trunks and branches , removing the roots and stacking of serviceable materials and disposal unserviceable material.
603a) beyond 30 cm Girth upto and including 60 cm girth
604b) Beyond 60 cm girth upto and including 120 cm girth
605c) Beyond 120 cm girth upto and including 240 cm girth
606d) Beyond 240 cm girth
607Earthwork in excavation and backfilling in layer of 200mm for foundations of buildings, basements, pipe supports, equipments as well as for manholes, plinth, tunnels, trenches for pipes & sewers & storm water drains, culverts etc., in ordinary and hard soils in both dry and wet conditions including pumping and bailing out surface and subsoil water (dewatering), shoring, strutting, slush removal at all heights and depths as per drawing and specifications wherever required , and backfilling in foundation pits and other places with excavated suitable surplus earth, including reclaiming from other soil heaps kept elsewhere and dressing and levelling,watering and mechanical compaction etc.,transporting surplus unserviceable soil to a place within GA and spreading in layers as per specifications or heaping up to any heights and as per the direction of Engineer Incharge. The Measurement for payment shall be for the theoretical volume only i.e., the volume of the block of the excavation having maximum bottom dimension of the foundation as per drawing.(Approval of location of disposal from local authority is in scope of contractor.)
608(The Contractor shall take into account in his rate the provision for excess excavation for necessary working space, slope etc., required for excavation and other allied works and refilling the side slopes and working space as mentioned in the specification).
609For depth upto & including 1.50 m
610For depth beyond 1.50 m and upto & including 3.00 m
611Extra FOR disposal of surplus earth beyond initial lead of 50m upto 10 KM
612Earth filling from available earth (excluding rock) under floors and other places with special compaction to achieve dry density of 95% standard proctor density including cost of excavation, reclaiming from soil heaps within work premises as per instruction of the EIC at all heights/depths, transporting, depositing, compacting and dressing, trimming complete as desired in layers not exceeding 15 cms including watering, consolidating by mechanical means as per specifications and instructions of the EIC.
613a) With available good quality earth
614Earth work in filling with good quality imported earth from approved source in the layers of 150 mm and compacted up to 95% to its MDD and any plan dimension including all testing, watering, rolling each layer with roller or wooden or steel rammers, and every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing / filling up ground depressions etc. complete in all respect as per scope of work, detailed construction drawings , as per technical specifications and directions of the Engineer-in-charge.
615CEMENT CONCRETE
616Supplying and laying plain cement concrete of the following proportions at all leads and lifts in all levelling courses under foundations, floors, pipelines, trenches, pits etc. using graded stone aggregate 20 mm max. size and down including mechanical mixing, transporting,shuttering (if required) consolidation, finishing, curing etc. complete,as per specifications, drawings and instructions of the Engineer Incharge.
617M-15 1:2:4
618M-10 1:3:6
619STEEL REINFORCEMENT
620Supplying, fabricating and fixing in position TMT steel reinforcements of grade Fe 500 at all levels and positions, all leads and lifts including the cost of transport, straightening, cutting, bending, cranking, binding, fixing, tying in position with annealed binding wire, welding provision of necessary chairs and spacers, including tying and bending dowel bars and their straightening upon deshuttering (wherever necessary) as per drawings and specifications and including cost of binding wire, labour, cover blocks in CM 1:2 etc., all complete for reinforced concrete as per specifications, drawings and instructions of the Engineer Incharge.
621a) Reinforcement conforming to Grade Fe-500 of IS : 1786-2008 ( TMT bars from SAIL /RINL/TATA STEEL/JSW )
6221. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as steel Reinforcement, binding wire and other minor construction materials, testing etc. all bye works and sundry works. 2. Chairs, Laps, Spacers, Wastage etc. shall be to contractor's account.
623Supplying and Laying of design mix,Reinforced Cement Concrete of following Grades at all depths and heights in all types of Foundations, Footings, equipment foundations,columns, pedestal,wall, lintels, ducts, beams, brackets, slabs of all shapes, sills, parapets,bands and any other works both in sub and Superstructures all complete with all bye works as per Drawings, Specification and instruction of Engineer. (The rates shall include the cost of necessary shuttering but excluding the cost of steel reinforcement)
624M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) UPTO PLINTH LEVEL
625M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) ABOVE PLINTH LEVEL
6261. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, other minor construction materials, shuttering , staging, removal of form work, testing of concrete, curing etc. except reinforcement steel with all bye works and sundry works complete. 2. Mix deisgn shall be prepared confirming to relevant IS Codes ( IS 10262, SP.23 & IS 456 Latest Codes) from NABL approved lab and the same shall be approved by EIC.
627Providing, constructing and finishing of compound wall in RCC frame structure with precast RCC wall panels of 100mm thickness mounted on in-situ RCC columns of 400mmx450mm size at an interval of 3.0 m or as specified in construction drawing and height 2m as specified as per scope of work , including plastering, coping, painting, whitewash,concertina coil, embossing of logo of the client, on all columns, finishes all complete as per technical specifications, tender drawing and direction of the Engineer-In-Charge.
6281. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, pre cast wall panels ,ISMC channel section,hard drawn steel wire fabric as per IS 1566 ,RCC M25, concertina coil, RBT , finishes, bitumen, Y angle, other minor construction materials, shuttering, staging, coping, expansion gap filling with \\"Capcell\\" armoured board of \\"Supreme\\" make or equivalent and white sealant material, plastering,painting and all other sundry works.
6292. Foundation/ sub-structure to be paid separately in respective SOR items.
6303.Reinforcement for columns and beam for superstructure shall be paid separately in respective SOR Item.
631Supplying & grouting for Foundations bolt holes/pockets for Equipments, Base plates, Anchoring etc, with cement based non shrink compound such as Shrinkomp of ACC or approved make of FOSROC/SIKA/ROFF including shuttering at all levels and as per drawings, specification and direction of Engineer in charge.
632Providing and laying roof screed with M-15 grade concrete (12 mm down graded coarse aggregate) at all leads and lifts with wooden trowel finish and required slope including mixing of water proofing compound as per manufacturer's specification, curing etc. , as per drawings and direction of Engineer Incharge.
633CC BLOCK work
634Providing and laying cement blocks (solid blocks) masonry mix ratio of 1 :1.5:3 with 200 mm thick blocks upto plinth level and super structure above plinth level up to top level of building in cement mortar 1:3 (1 cement : 3 coarse sand ).
635Upto Plinth level
636Above plinth level
637Brick work with bricks of class designation M 7.5 Grade with Mortar 1:6 (1 Cement: 6 Coarse sand) in all levels.
638Providing and fixing 100mm thick M-25 factory made RCC drain/trench cover including cost of shuttering and minimum reinforement@ 10mm dia TMT Fe-500 bars @100mm c/c bothway in two layers as per direction of Engineer In Charge.The RCC cover shall have edge protection with 100mm wide 1.6mm thick MS sheet all around alongwith 2 nos 12 mm dia bar for hook etc complete including painting of MS sheet.
639Providing and fixing 150mm thick M-25 Pre cast RCC drain/trench cover including cost of shuttering as per drawing and direction of Engineer In Charge. The RCC cover shall have edge protection with 150mm wide 1.6mm thick MS sheet all around alongwith 2 nos 16 mm dia bar for hook etc complete including painting of MS sheet. Reinforcement shall be paid in respective SOR Item.
640Providing and laying R.C.C.(M25 Grade concrete) vacuum dewatering concrete flooring with floor hardener of approved make to be sprinkeled at the rate of 5 kg/sqm before mechanical troweeling as per manufacturer's specifications including mixing, tamping mechanically, consolidating, leveling cement concrete of grade M25 in grade slab, 200/150 thick including suction drying, mechanical trowelling (power float) and finishing, curing, cutting expansion grooves and filling expansion grooves with polysulphide joint fillers complete as specified and directed including shuttering but excluding reinforcement, including doweled construction joints as per drawings.
641FINISHING
64212 mm cement internal plaster on walls of all heights at all levels in perfect line and level
64318 mm external cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:5 (1 cement : 5 fine sand) for all heights and levels in perfect line and level
644Painting with APEX/Wheathershield make exterior paint with one coat of primer and two or more coat of approved paint on new work wherever required to achieve even shade and colour for all heights and levels.
645Providing and laying paving of pre cast concrete interlocking pavers made of M30 grade concrete of 80 mm thickness of approved colour combination, pattern make, size, of compressive strength 300KG /sq cm. Paver blocks should be laid on sand cushion as required with a gap of 1.5mm between the blocks filled with sand including paving and curb gap to be filled with concrete of same grade of concrete pavers
646DISMANTLING/DEMOLISHING
647Demolishing of Cement Concrete (PCC) of all grades manually/mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead.
648Demolishing of RCC of all grades manually/ mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58495065
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 03-12-2026
Authority
Authority Name Gas Authority Of India Limited
Work Description Tender for Composite Works Cng Stations At Dakshin Kannada & Bastar Gas - Electrical, Mechanical, Structural & Civil Works (Dakshin Kannada)
Basic Detail
Tender No GAIL GAS/NOIDA/PK/4213/26-27/99
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 12 Nov 2026
Submission Date 03 Dec 2026
Open Date 04 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 18.40 Lakhs
Exemption Available
Document List
4c9db238-534b-4645-b2a3-0f732cce7f73.html
BOQ_346692.xls
TECHSPEC1.pdf
TECHSPEC2.pdf
TECHSPEC3.pdf
TECHSPEC4.pdf
TECHSPEC5.pdf
Tenderdoc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

4c9db238-534b-4645-b2a3-0f732cce7f73.html

xls

BOQ_346692.xls

pdf

TECHSPEC1.pdf

pdf

TECHSPEC2.pdf

pdf

TECHSPEC3.pdf

pdf

TECHSPEC4.pdf

pdf

TECHSPEC5.pdf

pdf

Tenderdoc.pdf

pdf

Tendernotice_1.pdf