Tender For Repair/ Maintenance To Air Cooled Ductable Acs Of Different Capacities And Walk In Coolers/ Cold Storage Including Replacement Of Spares With Misc E/M Works At Chaf Banglaore
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Dec 2026
17 days left
EMD
34000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance To Air Cooled Ductable Acs Of Different Capacities And Walk In Coolers/ Cold Storage Including Replacement Of Spares With Misc E/M Works At Chaf Banglaore
BOQ
| Sl. No. | Item Description |
| 1 | Periodical maintenance to ductable split type AC of any make including servicing of cooling coil, expansion valve, outdoor unit etc., as and when ordered as in preventive maintenance including cleaning, removing the dust particles of air filters replacement of all worn out parts, greasing of fan motors, checking of gas pressure, charging of refrigerant etc., all as required for the smooth and satisfactory functioning complete all as specified and as directed by Engr-in-charge for the following capacity:Notes for Item Nos.1.01 to 1.14:(i) Replacement of spares /parts shall be measured and paid separately under relevant items of this schedule.(ii) Contractor will be responsible for maintaining a Record /Register of servicing /Repairing of each unit. |
| 2 | 8.5 TR capacity incl 01 x air handling unit with belt driven motor, blower air filters, shaft assembly, cooling coil, expansion valve, 02 x outdoor units and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: CTVS OT |
| 3 | 5.5 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: CTVS Corridor |
| 4 | 7.5 TR capacity incl cooling coil, expansion valve, 02 x outdoor units and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: Nuclear Medicine-1 |
| 5 | 7.5 TR capacity incl cooling coil, expansion valve, 02 x outdoor units and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: Nuclear Medicine-2 |
| 6 | 5 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: Nuclear Medicine-3 |
| 7 | 11 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: ICCU |
| 8 | 8.5 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: PET Centre, G/F-1 |
| 9 | 8.5 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: PET Centre, G/F-2 |
| 10 | 8.5 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: PET Centre, F/F |
| 11 | 5.5 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: PET Centre, G/F |
| 12 | 5.5 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: PET Centre, F/F |
| 13 | 3 TR capacity incl cooling coil, expansion valve, 01 x outdoor unit and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: PET Centre, First Floor |
| 14 | Air Handling Unit with 5.5 TR capacity outdoor unit (Make-Blue Star) - 02 Nos incl motor, blower air filters, shaft assembly, cooling coil, expansion valve and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: ART Centre Family wing |
| 15 | Air Handling Unit with 5.5 TR capacity outdoor unit (Make-Voltas) - 01 No incl motor, blower air filters, shaft assembly, cooling coil, expansion valve and other accessories/ parts complete all as specified and as directed by Engr-in-charge.Location: BMT Centre Family wing |
| 16 | Material and labour for pressure testing and rectifying the leakages found in the system of ductable type ACs of 5/ 5.5/ 7.5/ 8.5/ 11 Ton capacity including vacuuming and charging the refrigerant gas to the desired pressure complete for satisfactory functioning complete all as specified and as directed by Engr-in-charge.Note: Refrigerant gas will be measured and paid seperately under respective item. |
| 17 | Supply and fix in replacement hermatically sealed scroll compressor suitable for ductable type split type AC complete all as specified and as directed by Engr-in-charge for the following capacity:Notes for item Nos. 3.01 to 3.04:(a) Make - Kirloskar / Tecum Seh / Shri Ram / Copeland / Danfoss.(b) Refrigerant charging will be measured and paid seperately in respective item.(c) Old/unsv compressor shall be replaced with the same make.(d) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer as one to one replacement. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase. Supporting documents for replacement from manufacturer/ dealer alongwith warranty certificate and paid vouchers shall be furnished by the Contractor. |
| 18 | 5 / 5.5 TR |
| 19 | 7.5 TR |
| 20 | 8.5 TR |
| 21 | 11 TR |
| 22 | Supply and fix in replacement remote sensing unit /assembly suitable for ductable type AC corded/ cordless with PCB board as per existing complete suitable for ductable AC complete all as specified and as directed by Engr-in-charge for the following capacity: |
| 23 | 5 / 5.5 TR |
| 24 | 7.5 TR |
| 25 | 8.5 TR |
| 26 | 11 TR |
| 27 | Supply and fix in replacement contactor 3 phase, 440 V, coil voltage 230 V, 32 amp rating suitable for ductable type ACs/ walk in cooler of any capacity complete all as specified and as directed by Engr-in-charge. |
| 28 | Material and labour for refrigerant gas for ductable AC of capacity 5 / 5.5 / 7.5 / 8.5 / 11 TR and walk in coolers 3 TR, as required of following type complete all as specified and as directed by Engr-in-charge. |
| 29 | R-407 |
| 30 | R-404 |
| 31 | Supply and fix in replacement running capacitor for blower motor/ condenser fan motor of ductable AC / walk in cooler complete all as specified and as directed by Engr-in-charge for the following capacity. |
| 32 | 8 mfd |
| 33 | 10 mfd |
| 34 | Supply and fix in replacement heat insulation superior quality nitrile rubber 19mm for copper tubing any size of refrigerant line including necessary clamps, PVC tape, knots etc., complete all as specified and as directed by Engr-in-charge. |
| 35 | Supply and fix in replacement fan blade suitable for condenser fan motor of any make for the following capacity of ductable type AC complete all as specified and as directed by Engr-in-charge. |
| 36 | 5 / 5.5 / 7.5 Ton capacity |
| 37 | 8.5 / 11 Ton capacity |
| 38 | Supply and fix in replacement electric blower motor, 230 Volt for indoor complete suitable of following capacity of ductable type AC complete all as specified and as directed by Engr-in-charge. |
| 39 | 5 / 5.5 / 7.5 Ton |
| 40 | 8.5 / 11 Ton |
| 41 | Supply and fix in replacement electric condensor fan motor, 230 V, outdoor suitable for following capacity of ductable type AC complete all as specified and as directed by Engr-in-charge. |
| 42 | 5 / 5.5 Ton |
| 43 | 7.5 / 8.5 / 11 Ton |
| 44 | Supply and fix in replacement expansion valve suitable for following capacity of ductable type AC complete all as specified and as directed by Engr-in-charge.Note: Refrigerant charging will be measured and paid seperately in respective item. |
| 45 | 5 / 5.5 Ton |
| 46 | 7.5 Ton |
| 47 | 8.5 / 11 Ton |
| 48 | Supply and fix in replacement copper tube of superior quality suitable for refrigeration and suction lines of ductable type ACs /walk in cooler of follwing sizes complete all as specified and as directed by Engr-in-charge.Note: Refrigerant gas charging will be measured and paid seperately in respective item. |
| 49 | 9mm dia |
| 50 | 18mm dia |
| 51 | 29mm dia |
| 52 | Supply and fix in replacement single phase preventor, 3 phase, 415 V, as per existing suitable for any capacity of ductable AC complete all as specified and as directed by Engr-in-charge. |
| 53 | Supply and fix in replacement blower motor assembly with blade for any capacity of ductable AC as per existing complete all as specified and as directed by Engr-in-charge. |
| 54 | Supply and fix in replacement drier filter complete all as specified and as directed by Engr-in-charge.Note: Refrigerant charging will be measured and paid seperately in respective item. |
| 55 | Material and labour for rewinding of electric blower motor 5 HP with copper wire super enameled for AHU and fixing complete all as specified and as directed by Engr-in-charge. |
| 56 | Material and labour for bearing for AHU blower motor assembly with rubber bush as per existing /as required complete all as specified and as directed by Engr-in-charge. |
| 57 | Supply and fix in replacement electric blower motor 5 HP for AHU as per existing complete all as specified and as directed by Engr-in-charge. |
| 58 | Supply and fix in replacement electric exhaust fan motor, 1 HP, 230 V for AHU as per existing complete all as specified and as directed by Engr-in-charge. |
| 59 | Supply and fix for fan belt for AHUs of size /model B/50 suitable as per existing complete all as specified and as directed by Engr-in-charge. |
| 60 | Supply and fix pre filter, 5 micron of suitable size for indoor unit /filter coil unit at different locations /capacities complete all as specified and as directed by Engr-in-charge. |
| 61 | Material and labour for AC drain hose outlet CPVC pipe of standard size 1\\" (25mm) complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 62 | Material and labour for AC drain hose outlet CPVC pipe of standard size 1\\" (25mm) complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender