Power Boards / Undertakings / PSU Closing in 3 days TDR #58493686

Tender For Construction Of Outdoor Control Room Building, Electrification ,Plumbing Works, Reinforced Cement Concrete Road, Gate Pillar & Wing Wall Etc., For The Upgradation Of Existing 33/11Kv Into 110/33/11Kv Ss At Thellar With 2X25 Mva, 110/33Kv P

Issued by Boards / Undertakings / PSU · Chennai, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Nov 2026
3 days left
EMD
1.07 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Outdoor Control Room Building, Electrification ,Plumbing Works, Reinforced Cement Concrete Road, Gate Pillar & Wing Wall Etc., For The Upgradation Of Existing 33/11Kv Into 110/33/11Kv Ss At Thellar With 2X25 Mva, 110/33Kv Power Transformers.

BOQ

Name of Work:- Construction of Outdoor Control Room Building, electrification ,Plumbing works, RCC Road, Gate pillar & Wing wall etc., for the Upgradation of existing 33/11kV into 110/33/11kV SS at Thellar with 2x25 MVA, 110/33kV Power Transformers.
Sl. No. Item Description
1Clearing heavy jungle including all cost of labour ,lead, lift etc., complete, and as directed by the Engineer at site.
2Earth work excavation for foundation in ordinary soil with lead of 10 to 100 m and lift of 3m in sand, silt or other loose soil, wet sand, or silt not under water, light black cotton soil, sandy loom and ordinary soil including excavated earth. Soft disintegrated rock not requirng blasting
3Earth work excavation for foundation in ordinary soil with lead of 10 to 100 m and lift of 3m in sand, silt or other loose soil, wet sand, or silt not under water, light black cotton soil, sandy loom and ordinary soil including excavated earth. In Medium rock and dense medium rock not requiring blasting
4Earth work excavation for foundation in ordinary soil with lead of 10 to 100 m and lift of 3m in sand, silt or other loose soil, wet sand, or silt not under water, light black cotton soil, sandy loom and ordinary soil including excavated earth. Removal of hard rock by wedging and chiselling and trimming to proper shape
5Supplying and filling in foundation and basement with filling sand in layers not more than 15 cm thick well rammed and watered consolidated etc complete as per standard specification
6Transporting the surplus excavated earth, debris etc away from the site to a lead of 2km including cost of all lead, lift, conveyance , loading, unloading etc. complete
7Re filling in foundation with excavated earth in layers not more than 15 cm thick well rammed and watered consolidated etc complete as per standard specification
8Providing anti termite treatment in 4 stages I) immediate after earth work excavation and before laying foundation concrete II) after refilling for sides of foundation III) Before laying of flooring concrete IV) outside of basement upto 1.0m alround the building using BIFLEX-C termite 250ml for 10lit of water etc. complete.
9Plain cement concrete 1:3:6, using 20 mm HBG metal for foundation without formwork including cost of cement, all materials, labour, lead, lift, etc. complete.
10R:C:C 1:1.5:3 using 12 to 20mm metal without form work including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.
11P:C:C 1:2:4 using 12 to 20mm HBG metal without form work including cost of all materials, curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.
12R:C:C 1:1.5:3 using 12 to 20mm metal with form work including cost of all materials,curing, labour, lead, lift etc. complete. as per standard specification as directed by the dept. Engineer at site.
13Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. For Grade Beam
14Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site . For Plinth beam concrete.
15Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. - Column up to basement
16Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. - RCC wall
17Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. For Coloumn.
18Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. For cast in situ cover slab.
19Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. For Percast slab.
20Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. For Roof Beams in stilt floor
21Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. For Roof slab
22Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. For Lintel
23Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade with a minimum cement content of 360 kg per cu.m for reinforced concrete structural elements under controlled water cement ratio with plasticiser using 20mm and downgraded metal including form work, but excluding cost of steel reinforcement. (up to basement level) including cost of all lead lift labour,etc complete ans as directed by the Engineer at site. For sunshade and loft
24Providing steel reinforcement for RCC works including cost of steel rod binding wire and placing in postion of the steel reinforcement all materials, lead and lift etc., complete.
25Brick work in CM 1:5 using all II class Ground Moulded chamber Burnt bricks for basement including cost of all materials, all labour charges, lead, lift, etc. complete. - Foundation and Basement
26Brick work in CM 1:3 using fly ash bricks for partition wall, 115mm thick, using II class ground moulder chamber burnt brikcs including cost of all materials, all labour charges, lead, lift, etc. complete.
27Brick work in CM 1:6 using all II class Ground Moulded chamber Burnt bricks for Superstructure including cost of all materials, all labour charges, lead, lift, etc. complete. - Ground Floor
28Plastering with cm 1:3, 12mm thick for bottom roof slab, bottom and side of sunshades partition walls including cost of cement, all materials,curing, labour, lead and lift etc., complete.
29Plastering with cm 1:5, 20mm thick for outside walls including cost of cement, all materials,curing, labour, lead and lift etc., complete.
30Plastering with cm 1:3, 20mm thick with water proofing chemical for car park plinth protection, water tank etc, including cost of cement, all materials,curing, labour, lead and lift etc., complete.
31Supplying and fixing MS grill , MS grills gate , name board, hand rail, ladder etc. at various levels as per approved drawing using channel, square rods, ornamental grill parts and flats including fixing in position with suitable hold-fast locking arrangements etc. complete as per standard specification. for windows
32Supplying and fixing UPVC (Un-Plasticized Polyviny Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
33Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Fixed & Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The ventilators have provisions for fixing exhaust fan of suitable size. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
34Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lamInstallation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
35Supplying and fixing in position of Sun control film in glazed windows of approved quality and brand including cost of all materials, lead, labour etc.complete.
36Paving the control room floor with rectified vitrified core endura grey coated floor tiles (Industrial type floor of johnson endura make , quality, colour and shade as directed by the engineer at site) of size 600 mm x 600mmx12mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand) 20mm thick laid in-situ and pointed with same coloured cement mortar neatly finished as per standard specification, including cost of all materials, Water Resistant Tile Epoxy Grout lead, labour etc.complete.
37Paving the floor with acid resistant tiles (quality, colour and shade as directed by the engineer at site) of size 305 mm x 305mm x 6 mm in battery room over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement including cost of all materials, Water Resistant Tile Epoxy Grout lead, labour etc.complete.
38Dadooing walls with glazed tiles of best approved quality of make Johnson, Nitco, Euro of size 300x200 mm over cm 1:2, 12mm thick including cost of all materials, labour, lead, lift etc., complete (Dadooing with printed design colour glazed tiles of size 300mm x 200mm x 6mm)
39Flooring with approved spartec ceramic non-slippery tiles 300x300mm size of approved Quality, design & colour (Johnson or equivalent make)laid in cement mortar 1:3 -20mm thick including pointing with same coloured cement using 0.4kg/M2, finishing the joints, including cost of all materials, labour, lead, lift, etc. complete
40Finishing the top of floor with Granolithic Finish with CC 1: 2: 3 (one cement Two sand & three HBS jelly) 50 mm thick using chips of grade 10 mm and below and rubbed smoothly
41Paving the Top of roof with Solar refelective ceramic tiles of approved quality and colour laid in Cement mortar bed in 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with water resistant tile epoxy grout for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works) inclusive cost of all materials, transport, curing, etc., complete as per standard specification including cost of all materials ,labour, lead ,lift etc complete.
42Supplying and erection of 2.0HP Texmo/ Kirloskar/ Sharp/ Suguna make jet pump with all accessories, suitable L&T/ Siemens starter, L&T main switch, fuse, foot valve, etc. including cost of all materials as directed by the Engineer at site, commissioning etc. complete. for Borewell.
43Supplying and erection of 3.0 HP Texmo/ Kirloskar / Sharp/ Suguna make Monoblock pump with all accessories, suitable L&T/ Siemens starter, L&T main switch, fuse, foot valve, etc. including cost of all materials as directed by the Engineer at site, commissioning etc. complete. (For Sump water)
44Supplying and fixing of wash basin of size 550*400mm with all accessories of approved quality Parryware / Hindware including cost of wash basin with 15mm CP Pillar cock fixing using rag bolt and nut 15mm dia nylon connection hose and outlet using 32mm dia pipe waste coupling waste pipe water pipe for outlet including 15mm control wheel valve, 15mm dia brass nipple etc. complete as per standard specification.
45Supply and fixing in position of Indian make white/ Colour glazed earthen ware lipped mouth flat back urinal basin of best approved quality of size 450mm with GI pipe connection to suitable length ,32mm bell mouthed PVC connection ,20mm dia GM wheel valve fixing the urinal to the wall including cost of all material,labour etc.complete.
46Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
47Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \\"P\\" or \\"S\\" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
48Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \\"P\\" or \\"S\\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges and good quality CP Health faucets including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings..... such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
49Supplying and fixing white marble stone of size 600*1200mm, 20mm thick for partition to urinals including cost of all materials , lead lift,etc complete.
50Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
51Supplying and fixing in position RCC Pre-fabricated Manhole covers 450X450 of best approved quality and as per standard specification etc. complete
52Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
53Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
54Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
55Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works).
56Supplying and fixing in position CP bib cock of size 15mm dia with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP bib cock should be got approved by the Executive Engineer before use on works).
57Providing and fixing testing and commissioning of PVC pipe for internal soil, waste & vent to IS:13592 of SWR quality, 4kg /sq.cm, including all fittings like tees, elbows, bends, collars, coupling, etc jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. Dia 4\\"
58Providing & fixing of UPVC pipe with fittngs like tees, elbows, bends, unions, coupling, reducer tees, collars etc. The work shall include cutting jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc. making holes, including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors. UPVC pipe 40mm dia
59Providing & fixing of UPVC pipe with fittngs like tees, elbows, bends, unions, coupling, reducer tees, collars etc. The work shall include cutting jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc. making holes, including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors. UPVC pipe 32mm dia
60Providing & fixing of UPVC pipe with fittngs like tees, elbows, bends, unions, coupling, reducer tees, collars etc. The work shall include cutting jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc. making holes, including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors. UPVC pipe 25mm dia
61Providing & fixing of UPVC pipe with fittngs like tees, elbows, bends, unions, coupling, reducer tees, collars etc. The work shall include cutting jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc. making holes, including chasing in solid block masonry walls with groove cutting machine to required width and depth, making bores in walls, foundations and RCC slabs, making good the walls and bores in CM 1:3 as applicable clearing the debris, grouting of concealed pipes, MS hooks for fixing pipes and making good the walls and floors. UPVC pipe 20mm dia
62Supply and fixing of HDPE pipe 32mm dia 10 Kg/Sq.cm for Borewell , including cost of all labour, lead lift etc,complete and as directed by the Engineer at site
63Supply and fixing of HDPE pipe 25mm dia 10 Kg/Sq.cm for Borewell including cost of all labour, lead lift etc,complete and as directed by the Engineer at site
64Supply and fixing of GI pipe 25mm dia B class for motor connection including cost of all labour, lead lift etc,complete and as directed by the Engineer at site
65Levelling the ups and downs of the location by engaging JCB for marking of foundations, etc., with all hire charges etc complete.
66Supply and fixing of PVC Pipe 140mm dia. 6kg/ sq.cm for bore well including cost of all labour, lead lift etc,complete and as directed by the Engineer at site
67Supply and fixing PVC Pipe 140mm dia. 6kg/ sq.cm for bore well strainer pipe with slotted holesincluding cost of all labour, lead lift etc,complete and as directed by the Engineer at site
68Drilling borewell in all kinds of soil 150 mm dia using rotary drilling power driven/ hand driven equipments including hire charges for equipment, bentonite solution, labour etc. complete
69Supplying and filling with pebbles for annular space between strainer pipe and earth surface including cost of all materials, lead, lift etc. complete.
70Flushing the borewell with power rotary flushing equipement including mobilisation and demobilisation etc. complete, including cost of all labour, lead lift etc,complete and as directed by the Engineer at site
71Supplying and fixing of SINTEX pvc water tank of 1000 litres capasity with necessary specials and fittings including cost of all materials , lead lift etc complete
72Painting 2 coats with approved Plastic Emulsion paint over one priming coat of plastic emulsion paint over cement plastered wall surface, ceiling and other new surface and including cleaning ,preparing the surface and curing etc.complete.
73Colour washing 2 coats with approved Emulsion paint over one priming coat over cement plastered wall surface applying wall putty, cleaning with sand paper , including cleaning ,preparing the surface cost of all labours to work at all levels, all materials, Scaffolding etc.complete.
74Painting new iron works with two coats synthetic enamel paint over one coat of primer including cost of all materials, lead, lift, etc complete and as directed by the Engineer at site.
75Dismantling PCC met with below ground level during execution including labour, tools etc. complete and as directed by the Engineer at site.
76Dismantling RCC met with below ground level during execution including labour, tools etc.complete and as directed by the Engineer at site.
77Dismantling brick/ stone masonry in cement mortar met with below ground level during execution including labour, tools etc. complete and as directed by the Engineer at site.
78Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.
79Supplying and fixing MS angle, channel,, MS rail, MS chequered plate, etc wherever required as directed by the Engineer as per standard specifcation, including cost of all lead,lift labour and as directed by the Engineer at site
80Supplying and fixing MS Chequred plate 6 mm thick including cost of all materials, lead,lift,labour etc., complete and as directed by the engineer site .
81Filling with good quality gravel including cost of material, labour all lead and lift etc . Complete complete and as directed by the Engineer at site.
82Supply and fixing 1 no 4 way Three phase and natural distribution board with insulator and 1 No.MCB of 6 amps each of standard company as approved by the engineer including cost of all materials, lead, lift, etc., complete.
83Supply & run of 3 1/2 core 70 sq.mm. PVC Armoured UG Cable with all accessories from Main EB pillar box to EB meter.
84Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 5A 3 pin non inter locking flush type CS plug with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open plug point (SD136)
85Supplying of switch board and wiring 2 runs of 4sq.mm PVC insulated copper wire and for earthing and connection with 15Amps switch and socket combined with 15 Amps plug and MS switch box size 6\\"x4\\"x3\\" for Battery point . This includes cost of materials and labour charges - SD 139
86Supplying and fixing box type 4'-40w single flouresent fitting complete with copper choke and condenser 1 no 4'-40w tube with T.W. round block on wall or ceiling with pvc unsheated leads from terminals to the fittings
87Supply and fixing of 1400 mm sweep (56\\") AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod including fan clamp with side plates and cross arm of size 450 mm.
88Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry .
89Supplying and fixing of water tight Bulk head fitting with guard and approved suitable make for incondescent lamp with guard and 100 w bulb.
90Supplying and fixing of 40mm dia. GI B class pipe for road crossing including cost of materials, labour lead, lift etc
91Supplying and fixing,testing & comissioning of Surface Mounted LED fittings for 100W LED with necessary connections etc.,of suitable for control room
92Providing expansion joint for road concrete as per specification in both direction using prevalid aspheltics pad 20 mm thick to full width and depth of 150mm thick plastering with CM 1:3, 20 mm thick including cost of cement, all materials, labour, curing, all leads, and lifts, etc., complete.as per standard specification.
93Wet Mix Macadam (Table 400-13) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, Complete as per clause 406 of MORTH Specification. MORTH No. 111,112, 406, 900.
94Forming berms on either sides of the road to a width of 0.60m to an average thickness 22.5 cm well consolidation by Power roller including packing and bringing the surface to camber etc.complete.
95Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead and lift etc., complete. sample to be approved by department Engineer S Type chair (Local rate)
96Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead and lift etc., complete. sample to be approved by department Engineer Three drawer steel table
97Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead and lift etc., complete. sample to be approved by department Engineer Steel side rack open type 4 shelf
98Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead and lift etc., complete. sample to be approved by department Engineer Steel half bench
99Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead and lift etc., complete. sample to be approved by department Engineer steel stool
100Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead and lift etc., complete. sample to be approved by department Engineer First Aid box set
101Supplying and fixing Digital wall clock ISI mark including cost of all materials, labour, lead and lift etc., complete. sample to be approved by department Engineer
102CGST in % (For Bidders inside TamilNadu)
103SGST in % (For Bidders inside TamilNadu)
104IGST in % (For Bidders outside TamilNadu) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58493686
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 26-11-2026
Authority
Authority Name Tamil Nadu Transmission Corporation Limited
Work Description Tender for Construction Of Outdoor Control Room Building, Electrification ,Plumbing Works, Reinforced Cement Concrete Road, Gate Pillar & Wing Wall Etc., For The Upgradation Of Existing 33/11Kv Into 110/33/11Kv Ss At Thellar With 2X25 Mva, 110/33Kv Power Transformers.
Basic Detail
Tender No CETP1-29/2026-27
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 12 Nov 2026
Submission Date 26 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.07 Lakhs
Exemption Available
Document List
62623ca8-62c2-4ee1-a390-1a49caf988c6.html
BOQ_870759.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

62623ca8-62c2-4ee1-a390-1a49caf988c6.html

xls

BOQ_870759.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender