Tender For Day To Day Maintenance Of E/M Works In Md & Otm Accn And Repair/ Replacement Of Lt Panels, Apfc Panels And Other Connected Works At Af Stn Samana Under Ge (Af) Jamnagar No. 1
Tender Value
40 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
12 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Day To Day Maintenance Of E/M Works In Md & Otm Accn And Repair/ Replacement Of Lt Panels, Apfc Panels And Other Connected Works At Af Stn Samana Under Ge (Af) Jamnagar No. 1
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Fixing in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type, 240 V fixed flush to wall, complete all as specified and directed by Engineer-in-Charge. |
| 2 | Supply & Fixing in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type, 240 V fixed flush to wall, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply & Fixing in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, double door type, fixed flush to wall, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Supply & Fixing in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way, vertical type with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, double door type 415 volts, fixed flush to wall, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply and fixing in repair MCB’s single pole 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and fixing in repair MCB’s single pole & neutral, 40-63 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and fixing in repair MCB’s single pole & neutral, 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and fixing MCB’s triple pole & neutral, 40-63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply and fixing in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 amps, 240 V, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply & Fixing in replacement of LED inverter tube light fitting 4 feet 20W charging time upto 8hrs, backup time atleast 4 hrs, having lithium ion battery capacity 2600mah, lumen efficacy 100l/watt, complete all as specified and directed by Engineer-in-Charge.Make:- Philips or equivalent make mentioned in Appendix 'B'. |
| 11 | Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC conduit not less than 25mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete all as specified and directed by Engineer-in-Charge.Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 12 | Material & Labour ion repair for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete all as specified and directed by Engineer-in-Charge.Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 13 | Material & Labour in repair for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC capping & casing or existing concealed conduit not less than 25mm wide, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC surface type terminal box of suitable size with PVC cover, complete all as specified and directed by Engineer-in-Charge. |
| 14 | All as per item No 13 above but point wiring for One light point controlled by two Nos 2-way switch, complete all as specified and directed by Engineer-in-Charge. |
| 15 | All as per item No 13 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch, complete all as specified and directed by Engineer-in-Charge. |
| 16 | All as per item No 13 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch, complete all as specified and directed by Engineer-in-Charge. |
| 17 | All as per item No 13 above but One bell /Buzzer point controlled by one push button on the same board with other switch, complete all as specified and directed by Engineer-in-Charge. |
| 18 | All as per item No 13 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply & Fixing in repair Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & Fixing in repair Switch Piano type, white polycarbonate body, single pole, two way 6 amp, 230 V, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply & Fixing in repair for Bell push, white polycarbonate body, 6 Amp, 230 V, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply & Fixing in repair for Switch socket combination white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply & Fixing in repair for Switch socket combination white polycarbonate body, 6A / 16A- 230 V, Multipurpose, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply & Fixing in repair for cassing capping of size 25-32 mm with its necessary accessories screw and bolt etc., complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply & Fixing in repair for PVC conduit of size 20-25 mm with its necessary accessories screw and bolt etc., complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply & Fixing in repair for Ceiling rose, 3 terminal polycarbonate body 6 Amps, 250 volts AC, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fixing in repair stepped type electronic fan regulator flush type, 230 V, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply & Fixing Bell ding dong AC 230 Volts, single pole, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply & Fixing in repair Recessed/ceiling mounted LED COB panel light of 12-16 watt, including all fitting, fixture, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply & Fixing in replacement of four way LED 6 watt lens type outdoor light dust and water resistance IP65 rating, warm white colour, aluminium body including all its mounting acessories required, complete all as specified and directed by Engineer-in-Charge.Make:- Philips, Wipro, Havells or equivalent make mentioned in Appendix 'B'. |
| 31 | Taking down carefully unserviceable ceiling fan of any size and type by disconnecting electric connection and deposit to MES store and supply and fixing of BLDC ceiling fan 1200mm, 5star energy rating, operating voltage 120-280V and connecting, complete all as specified and directed by Engineer-in-Charge. |
| 32 | Taking down carefully unserviceable exhaust fan of any size and type by disconnecting electric connection and deposit to MES store and supply and fixing high speed 2000 RPM, plastic body exhaust fan of size 200mm, operating voltage 170-280V and connecting accessories, complete all as specified and directed by Engineer-in-Charge. |
| 33 | supply and fixing in replacement for plastic body exhaust fan of capacity 200-225mm exhaust fan, complete all as specified and directed by Engineer-in-Charge. |
| 34 | supply and fixing in replacement for plastic body exhaust fan of capacity 300mm exhaust fan, complete all as specified and directed by Engineer-in-Charge. |
| 35 | supply and fixing in repair suicide fan downrod of 15'' with taking down and refixing the fan, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply & Fixing in repair air conditioner indoor unit single phase as per existing brand complete with all connection and taking out old unsv of cap 1.5 ton of air conditioner, complete all as specified and directed by Engineer-in-Charge. Make : Samsung / Voltas/ Carrier/ LG/ O General/ Hitachi/Bluestar |
| 37 | Supply & Fixing in repair air conditioner indoor unit single phase as per existing brand complete with all connection and taking out old unsv of cap 2,0 ton of air conditioner, complete all as specified and directed by Engineer-in-Charge. Make : Samsung / Voltas/ Carrier/ LG/ O General/ Hitachi/Bluestar |
| 38 | Supply & Fixing in repair air conditioner outdoor unit single phase as per existing brand complete with all connection and taking out old unsv of cap 1.5 ton of air conditioner, complete all as specified and directed by Engineer-in-Charge. Make : Samsung/Voltas /Carrier/ LG/ O General /Hitachi/Bluestar |
| 39 | Supply & Fixing in repair air conditioner outdoor unit single phase as per existing brand complete with all connection and taking out old unsv of cap 2.0 ton of air conditioner, complete all as specified and directed by Engineer-in-Charge.Make : Samsung/Voltas /Carrier/ LG/ O General /Hitachi/Bluestar |
| 40 | Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location (with AF station Samana), refixing of same AC at new location, complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer.(c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface.(d) Extension of copper pipe due to site condition if required shall be measured and paid separately under respective items taken before. |
| 41 | Supply and fixing in replacement of LED decorative suspended light 20 watt white/ warm white tone including all accessories, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply and fixing in repair cupromet copper tube ASTM B68 of size 1/4 inch x 0.48 mm including insulation on copper pipe of thickness 6mm, complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply and fixing in repair cupromet copper tube ASTM B68 of size 1/2 inch x 0.48 mm including insulation on copper pipe of thickness 6mm, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Material & Labour for replacement of 5 KVA Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with out put voltage stabilized at 230V with accuracy of ±2.5%, complete all as specified and directed by Engineer-in-Charge. |
| 45 | Material & Labour for replacement of 3 KVA Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with out put voltage stabilized at 230V with accuracy of ±2.5%, complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply & Fixing in repair energy efficient recessed mounted LED 36W luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3600 lumens colour temprature 3300K to 5300K having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required, complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply and fixing in replacement LED building security light 35 Watt LED street light made up of pressure die cast aluminium housing with LED as lighting source having IP66 protection and impact resistance of IK07, with potted driver 230 Volt with all connected acessories including GI pipe bracket, made out of 35mm dia light grade GI pipe required, complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply, fixing, connecting and testing in replacement of APFC Panel of capacity 125 KVAR (Output) @ 440Vac. The stage ratings shall be 1x2 KVAR + 1x3 KVAR + 2X 5KVAR + 1X10KVAR+ 2x25kvar + 1 x50 KVAR .The degree of protection of enclosures system of the APFC Panel shall be min. IP54. The APFC Panel shall be OEM made , machine pressed , dust and vermin proof , indoor type , Panel internally and externally shall be painted with expoxy powder coating paint & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading.The panel mounted on angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer , As equipment shall be comprising of the following:-Make:- Havells, Legrand, L&T (A) Insulated bus bar pan assembly made from Copper suitably rated capacity. ( B) The incomer of the APFC Panel shall be a suitable rated, MCCB. (C) Capacitor Units: The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of: 2.5 In, operating losses less than 0.5W/KVAR and peak inrush current shall be <200x In. (D) Short-circuit and Overload Protection: Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 36kA. (E) PF Regulator/ APFC Relay: Advanced Range PF Regulator / micro-processor based APFC relay having 12 steps with a LCD Display, Voltage Range: 90V - 550V, 50 / 60Hz, CT Input: 1A/5A with a built in RS 485 communication port. (F) Stage Contactor: The capacitor duty contactors shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. (G) Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, contactors, breakers etc. (H) Indication Lamp, Push button (Start and Stop) and Auto/Manual switch to be install for each stage of capacitor on Panel. |
| 49 | As per item no. 48 above but for rating 75 KVAR of stage 1 x 2 KVAR + 1 x 3 KVAR + 2 x 5 KVAR + 2 x 10 KVAR + 2 x 20 KVAR |
| 50 | As per item no. 48 above but for rating 50 KVAR of stage 1 x 2 KVAR + 1 x 3 KVAR + 1 x 7.5 KVAR + 3 x 12.5 KVAR |
| 51 | As per item no. 48 above but for rating 30 KVAR of stage 1 x 2 KVAR + 1 x 3 KVAR + 3 x 5KVAR + 1 x 10 KVAR |
| 52 | Supply, fabricating, installation, testing, commissioning and electrically connecting in repair LT panel Board 415 volts, factory made, machine pressed, dust and vermin proof, out door type made with CRCA sheet 3.15 mm thick, LT Panel internally and externally shall be painted with expoxy powder coating paint & two coats primer, before being given the stove epoxy finish, both side opening in two halves with rubber beading, bus bar of 400 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber and shall be provided with inspection covers, Each MCCB / Cubical switch shall have the independent opening panel and shall be mounted on angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer, embeding and grouting in PCC (1:2:4) type B:1 using 20mm graded crushed stone aggregate in foundation including necessay earth work complete, including all connections to MCCBs incoming/outgoing with suitable size of AL bus bar comprising of following accessories including testing complete all as directed. (a) MCCB 4 pole 415 volts 250 Amp rating with breaking capacity 25 KA, 01 No. (incoming) (b) MCCB 4 pole 415 volts 125 Amp rating with breaking capacity 25 KA, = 01 Nos. (outgoing).(c) MCCB 4 pole 415 volts 100 Amp rating with breaking capacity 16 KA, = 04 Nos (outgoing). (d) MCCB 4 pole 415 volts 63 Amp rating with breaking capacity 16 KA, = 02 Nos (outgoing). (e) Multifunction meter for measuring ampere,voltage, frequency & CTs of suitable ratio etc complete - 1 No(f) Indicator lamp R,Y,B = 01 Set of three. |
| 53 | Supply, fabricating, installation, testing, commissioning and electrically connecting in repair LT panel Board 415 volts, factory made, machine pressed, dust and vermin proof, out door type made with CRCA sheet 3.15 mm thick, LT Panel internally and externally shall be painted with epoxy powder coating paint & two coats primer, before being given the stove epoxy finish, both side opening in two halves with rubber beading, bus bar of 400 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber and shall be provided with inspection covers, Each MCCB / Cubical switch shall have the independent opening panel and shall be mounted on angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer, embeding and grouting in PCC (1:2:4) type B:1 using 20mm graded crushed stone aggregate in foundation including necessay earth work complete, including all connections to MCCBs incoming/outgoing with suitable size of AL bus bar comprising of following accessories including testing complete all as directed. (a) MCCB 4 pole 415 volts 200 Amp rating with breaking capacity 25 KA, 01 No. (incoming) (b) MCCB 4 pole 415 volts 63 Amp rating with breaking capacity 16 KA, = 08 Nos (outgoing). (e) Multifunction meter for measuring ampere,voltage, frequency & CTs of suitable ratio etc complete - 1 No(f) Indicator lamp R,Y,B = 01 Set of three. |
| 54 | Supply, fabricating, installation, testing, commissioning and electrically connecting in repair LT panel Board 415 volts, factory made, machine pressed, dust and vermin proof, out door type made with CRCA sheet 3.15 mm thick, LT Panel internally and externally shall be painted with expoxy powder coating paint & two coats primer, before being given the stove epoxy finish, both side opening in two halves with rubber beading, bus bar of 640 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber and shall be provided with inspection covers, Each MCCB / Cubical switch shall have the independent opening panel and shall be mounted on angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer, embeding and grouting in PCC (1:2:4) type B:1 using 20mm graded crushed stone aggregate in foundation including necessay earth work complete, including all connections to MCCBs incoming/outgoing with suitable size of AL bus bar comprising of following accessories including testing complete all as directed. (a) MCCB 4 pole 415 volts 400 Amp rating with breaking capacity 36 KA, 01 No. (incoming) (b) MCCB 4 pole 415 volts 100 Amp rating with breaking capacity 25 KA, = 08 Nos (outgoing). (c) Onload changeover switch 415 Volt 200Amp 4Pole -01Nos (d) Multifunction meter for measuring ampere,voltage, frequency & CTs of suitable ratio etc complete - 1 No(e) Indicator lamp R,Y,B = 01 Set of three. Please Enable Macros to View BoQ information |
| 55 | Supply, fabricating, installation, testing, commissioning and electrically connecting in repair LT panel Board 415 volts, factory made, machine pressed, dust and vermin proof, out door type made with CRCA sheet 3.15 mm thick, LT Panel internally and externally shall be painted with expoxy powder coating paint & two coats primer, before being given the stove epoxy finish, both side opening in two halves with rubber beading, bus bar of 640 Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber and shall be provided with inspection covers, Each MCCB / Cubical switch shall have the independent opening panel and shall be mounted on angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer, embeding and grouting in PCC (1:2:4) type B:1 using 20mm graded crushed stone aggregate in foundation including necessay earth work complete, including all connections to MCCBs incoming/outgoing with suitable size of AL bus bar comprising of following accessories including testing complete all as directed. (a) MCCB 4 pole 415 volts 400 Amp rating with breaking capacity 36 KA, 01 No. (incoming) (b) MCCB 4 pole 415 volts 100 Amp rating with breaking capacity 25 KA, = 08 Nos (outgoing). (c) Onload changeover switch 415 Volt 200Amp 4Pole -01Nos (d) Multifunction meter for measuring ampere,voltage, frequency & CTs of suitable ratio etc complete - 1 No(e) Indicator lamp R,Y,B = 01 Set of three. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender