Tender For Repair / Replacement Of Building Security Light Of Otm Accn And Md Accn Under Ge (W) Jrc
Tender Value
20 Lakhs
Estimated cost
Bid Submission
01 Dec 2026
9 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Replacement Of Building Security Light Of Otm Accn And Md Accn Under Ge (W) Jrc
BOQ
| Sl. No. | Item Description |
| 1 | M&L in repair for point wiring with PVC insulated, unsheathed cable single core multistranded copper conductor FRLSH cable 1.5 sqmm size, 1100V grade, drawn into and including PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLSH conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specifiedand directed.(a)One light / fan / call bell point controlled by one, one way switch. |
| 2 | Supply & fixing in repair switch piano flush button type single pole one way 6 Amps all as specified. |
| 3 | Supply & fixing in repair ceiling roses surfaces bakelite two three terminals 65 x 50 mm all as specified. |
| 4 | S&F SITC of high-quality integrated LED Street Light with a minimum system lumen of4750 Lm and system wattage not exceeding 45W with a nominal efficiency 105 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/ULaccredited lab to verify above parameters including bracket and fixing clamps etc and connecting electricalconnections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed. |
| 5 | S&F of SITC of high-quality integrated LED Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 60W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including bracket and fixing clamps etc & and connecting electrical connections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed. |
| 6 | S&F SITC of high-quality LED Flood Light with a minimum system lumen of 6000 Lm and system wattage not exceeding 50 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with CRI >70. The housing should be of pure polyester powder coated die-cast aluminum with high efficiency LEDs as lighting source. The fitting should have PC reflector for maximum output and PC Lens for symmetric distribution & tempered protective Toughened Glass with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 6 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and connecting electricalconnections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete as directed. |
| 7 | S&F SITC of high-quality LED Flood Light with a minimum system lumen of 12000 Lm and system wattage not exceeding 100 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with CRI >70. The housing should be of pure polyester powder coated die-cast aluminum with high efficiency LEDs as lighting source. The fitting should have PC reflector for maximum output and PC Lens for symmetric distribution & tempered protective Toughened Glass with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 6 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and connecting electricalconnections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete as directed. |
| 8 | Supply and fixing of new generation, post top, energy saving spun aluminium landscape luminaries with high power 40W LED , IP65 protection suitable for Pole dia 76mm pole complete with all accessories. Luminaire shall be made of pressure die cast/spun aluminium housing with high transmission clear diffuser, corrosion resistant powder coated finish, high efficiency LED driver with surge protection, minimum system efficacy 100 lm.W, CCT 3000K/4000K/6500k, CRI > 80, operating voltage 140-270 V AC complete all as directed. |
| 9 | M & L for LED TURIN BOLLARD gardern light fitting with post 10 Watt WHITE/WARM Luminaire ,Unique concept LED Bollard in IP 66 rating and connecting electrical from cable using PVC insulated and overall sheathed flexible copper conductor of size 0.75 mm 3 core including making of suitable size of platform PCC as per manufacturer design with nuts, bolts & washers ,incl provn on incoming and outgoing supply for light fitting in platform with PVC med grage pipe/bend and all necessary connection complete all as specified and directed. |
| 10 | Supply and laying XLPE insulated , armoured electric cable heavy duty with aluminium conductor , 1100 volts UG cable of size 3 Core 10 Sqmmm. |
| 11 | Supply and laying XLPE insulated , armoured electric cable heavy duty with aluminium conductor , 1100 volts UG cable of size 3 Core 16 Sqmmm. |
| 12 | Excavation in trenches in soft/lose soil not exceeding 1.5 Mtr wide and not exc 1.5M depth for laying of UG cables and getting out all as specified and directed. |
| 13 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms thick of soil complete all as specified and directed. |
| 14 | M&L river sand in trenches as cable cushioning 8 cm below the cables and 15cm above the cable which is to be punned down to 10m all as specified and directed only punned thickness will be measured. |
| 15 | Removing the surplus excavated material/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed. |
| 16 | Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed. |
| 17 | Supply and fixing /laying PVC conduit pipe 50 mm bore heavy grade fixed to pole with clamps nuts, Bend/Tee/Junction box , bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. |
| 18 | Supply and fix Sheet metal DB,double door, SPN 4 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc for outdoor/indoor operation. Distribution boards should be Double Door design with IP-43 and IK-08 rating as per IEC 61439-3 with 100 Amp fully insulated copper busbars, insulated neutral bar, earth bar and cable ties for cable management. Distribution board should be supplied with door earthing, prefitted masking sheet, reversible doors and pan assembly for easy installation. Must have possibility of converting lock to panel lock complete all as specified and directed. |
| 19 | Supply and fix Sheet metal DB,double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc for outdoor/indoor operation. Distribution boards should be Double Door design with IP-43 and IK-08 rating as per IEC 61439-3 with 100 Amp fully insulated copper busbars, insulated neutral bar, earth bar and cable ties for cable management. Distribution board should be supplied with door earthing, prefitted masking sheet, reversible doors and pan assembly for easy installation. Must have possibility of converting lock to panel lock complete all as specified and directed. |
| 20 | S&F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “B” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting. complete all as specified and directed. |
| 21 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type ,MCB should be having the Breaking Capacity of 10 kA and should be ISI marked as per IS/IEC 60898-1 2002 with “B” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting,complete all as specified and directed. |
| 22 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 foot apart including 4mm suspension wire, one twin core cable flat or circulat of size 6 Sqmm 2 Core complete. |
| 23 | M&L for earthing complete with GI steel earth plate electrod 60x60cmx6.00mm thick bouried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4 mm as earthing lead soldering/revated to earth plate at one end and connected DB by means of nut, bolts etc complete with PCC pit (1:3:6) type GI cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead all complete as specified and as per electric plate No.5 of SSR Part I. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysDec 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender