Project Description
Tender for Repair Maintenance Of External Lights Associated Wk And Repair Maintenance Of Misc Em Assets At Af Stn Samana Under Ge(Af) Jamnagar No.1
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Fixing in replacement of automatic street light switch using automatic switching of street light based on lux level of natural light the sensor along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take: THREE phase load of 12 KW and control unit having Auto Over / Low Voltage trip & Reset levels, Override facility for continuous ‘ON’ and continuous ‘OFF’ for maintenance and Duration based selection from 4 to 8 hours with half and hour resolution for night switch OFF etc., complete all as specified and directed by Engr-in charge. Make:- Nature Switch -Kakatiya Energy systems/Bajaj/Siemens |
| 2 | Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 16 Sqmm 4 Core, complete all as specified and directed by Engr-in charge. Note :- Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately. |
| 3 | Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 25 Sqmm 4 Core, complete all as specified and directed by Engr-in charge. Note :- Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately. |
| 4 | Supply & fixing in replacement of LED decorative aluminium housing top mounting LED lantern 50 Watt warm white IP65 protection resistant to impact and corrosion, glare free with all necessary acessories required, complete all as specified and directed by Engr-in charge. |
| 5 | Supply, Laying and Testing in replacement of PVC insulated multi stranded unarmoured copper cable 4 Sqmm 3 Core passing through 25mm PVC conduit including necessary excavation for laying of cable & conduit, complete all as specified and directed by Engr-in charge. |
| 6 | Supply, Laying and Testing in replacement of PVC insulated multi stranded unarmoured copper cable 1.5 Sqmm 3 Core passing through 25mm PVC conduit including necessary excavation for laying of cable & conduit, complete all as specified and directed by Engr-in charge. |
| 7 | Supply & fixing in replacement of LED flood light fitting 50 Watt of R/Y/B/G colour with IP 65/66 protection and impact resistance of IK-08, 230 Volts, made up of pressure die cast aluminium housing, potted driver & all accessories, complete all as specified and directed by Engr-in charge. |
| 8 | Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, foundation of poles/struts etc including necessary form work, complete all as specified and directed by Engr-in charge. |
| 9 | Material and labour for making the hole under road and hard standing for laying Galvanised steel light grade pipe upto 40mm dia including all fittings as required at site by mechanical drill system or Auger system and making the surface good as per existing surface, complete all as specified and directed by Engr-in charge. Note : The rate of Galvanised steel light grade pipe of size up to 40mm dia is included in this item and shall not be paid extra. |
| 10 | Supply & fixing in replacement 80mm bore light grade GI pipe for cable protection fixed on walls including all required fittings and fixtures, complete all as specified and directed by Engr-in charge. |
| 11 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, laying of cables or pipes (where provided) for protection of cable or fixing poles and stays and struts and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels, complete all as specified and directed by Engr-in charge. |
| 12 | Returning, filling in, approved soft/loose soil, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed by Engr-in charge. |
| 13 | Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed by Engr-in charge. |
| 14 | Supply and filling Local sand cushioning, with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable, complete all as specified and directed by Engr-in charge. |
| 15 | Supply and laying un- reinforced precast concrete cable cover Class LV type 1 Flat size 250mm x 150mm x 40mm, complete all as specified and directed by Engr-in charge. |
| 16 | Supply & fixing in replacement of PVC insulated and sheathed un-armoured two core aluminium conductor service cable 2 core 4 sqmm, 220 volt to be replaced in existing fittings including dismantling and taking out old burt electric cable, complete all as specified and directed by Engr-in charge. Please Enable Macros to View BoQ information |
| 17 | Supply & fixing in replacement of PVC insulated and sheathed un-armoured two core aluminium conductor service cable 2 core 4 sqmm, 220 volt to be replaced in existing fittings including dismantling and taking out old burt electric cable, complete all as specified and directed by Engr-in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender