Housing Urban and Rular Development Government Departments Closing in 14 days TDR #58491123

Tender For Special Repairs To electrical installation Fittings Fan And Power Main Arrangements Works To The Health Sub Centre Building At Karuvazhimadhapur, Sulur Block In Coimbatore District.

Issued by Government Departments · Coimbatore, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Dec 2026
14 days left
EMD
2960
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To electrical installation Fittings Fan And Power Main Arrangements Works To The Health Sub Centre Building At Karuvazhimadhapur, Sulur Block In Coimbatore District.

BOQ

Name of Work:- Special Repairs to EI Fittings Fan and Power Main arrangements works to the Health Sub Centre Building at Karuvazhimadhapur, Sulur Block in Coimbatore District.
Sl. No. Item Description
1Rewiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box on wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire withpainting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Higher End
2Renewal by supply and fixing of 9W LED Lamp for BH Point.
3Renewal by supply and fixing of 4 Feet LED 20 W Fitting with LED 20 W tube (Higher End)complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting
4Renewal by supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod with fan clamp with side plates and cross arm of size 450mm (18\\")
5Renewal by supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting .
6Renewal by supply and fixing of 3 nos.6A two module 3 pin socket , 3 nos. 6A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End
7Renewal by supply & Fixing of AC / DC 76mm Buzzer /call bell suitable for 230 Volts 50 c/s single phase AC supply on suitable TW Board with push switch.
8Renewal by supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End
9Renewal by supply and fixing of 20Amps DP plug and socket in sheet steel enclosure with 32A DP MCB in flush with wall with earth connection.[For AC Plug]
10Renewal by supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End
11Renewal by supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 32A 4P MCB as incoming and 12 Nos 6A to 32A SP MCB as outgoing on wall with Earth connection only. Higher End
12Renewal by supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour
13Renewal by supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4sq.mm copper wire with painting of suitable colour
14Renewal by supply and run of 4 of 4 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVCrigid pipe on wall and ceiling with continuous earth wire connection of 4s q.mm copper wire with painting of suitablecolour
15Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link(1\\"x1/8\\"copper flat) on TW plank of size 375mm x 300mmx 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earthconnection and interconnection with 7/20 PVC insulated copper wire from EB meter to fuse unit with1No 40 Amp 30MA Double Pole RCD / RCCB (Higher End) with suitable necessary connection
16Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3Nos.32A fuse unit (500V) 32A neutral link and earth link(1\\"x1/8\\"copperflat)on TW plank of size 600mmx450mmx19mm with supporting TWreepersof1\\" thickaneither side with painting with suitable bolt and nuts for fixing the TW plank on wall with earthconnection and interconnection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1No 40Amp 30MA Four Pole RCD / RCCB (Higher End) with suitable necessary connection
17Supply and fixing of 1000W automatic electric water heater of 25 litres capacity suitable for 230V 50c/s AC supply on suitable MS clamps with 3 core flex wire,but without plumbing work
18Renewal by supply and fixing of 1000VA UPS with 1 No 12V 150AH tubular battery [Exide IT 500] with 1hour backup and 48months warranty for mentioned capacity on full load operation and the following features. [V- Guard/ APC/ equivalent]a) Inverter shall be free from workmanship defects, sharp edges, nicks, scratches, burs etc, all fasteners shall be fixed properly. The equipments shall be complete with all parts and all parts shall be functional. b) Enclosure shall conform to protection requirement of IRL to IS 13947 (part 1) 1993. c) Switching device shall be MOSFET (or) IGBT.d) Switching frequency shall be about 50HZ.II. Input ; 120V to 260V 50 HZ single phase ACIII. Output : The variation in output voltage from NO- load to full load expressed as a percentage of no load voltage shall not exceed +1.5% over + 10 % and 20 % variation of the rated DC input voltage. The frequency of the output voltage shall be 50 HZ ± 1.3%.IV). Inverter efficiency minimum 85% as per CI.T.93 of ISS.v) Over load: inverter shall withstand 10% overload for at least 10 minutes.V).Protections. VI). a) When the Input voltage goes outside the range 120 volts and 260 volts the system shall switch over to inverter mode.b). Against over voltage, short circuit and over load at inverter output terminals.C). Battery reverses polarity.d). Protection against over discharge,load shall be cut off as soon as the voltage of the battery terminal falls below.i) 10.5V for 12V and ii) 21V for 24V battery system. e). The inverter shall incorporate an arrangement for automatic change-over of load from main supply to the inverter AC output in case of failure of mains supply with correct pending indication as per CL; 5.6 of IS 13314/ 1992 f). inverter should have surge protection also VII indicators.a) Following indicators shall be provided.i) Mains presenceii) Mains mode.iii) Battery charging.iv) INVERTER MODE v) Battery low.4 battery bank; 12 Volts lead battery to IS 7372(1995 ) with amdts.No1,2&3 shall be reputed makes with ISI.9) Battery stand with wheel angle iron frame arranged.
19Renewal by supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains
20Renewal by supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade on 7/20GI bearer wire for service connection mains
21Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 25 mm dia GIpipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains
22Renewal by Supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 25 mm dia GIpipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains
23Renewal by Supply and fixing of 32A DP sheet steel Enclosure complete set in flush with wall with earth connection (For Motor )
24Renewal by supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
25Re-Earthing as per PWD standard with an earth electrode of 2metre Class 'B 'GI pipe of dia not less than 32mm complete with necessary masonry work
26GST@18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58491123
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 01-12-2026
Authority
Authority Name Public Works Department
Work Description Tender for Special Repairs To electrical installation Fittings Fan And Power Main Arrangements Works To The Health Sub Centre Building At Karuvazhimadhapur, Sulur Block In Coimbatore District.
Basic Detail
Tender No 135/07N/CBE/ELE-DVN/2026-27
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 12 Nov 2026
Submission Date 01 Dec 2026
Open Date 02 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 2960
Exemption Not Available
Document List
227d08be-8df2-4541-a939-8dc52004554f.html
BOQ_870378.xls
HSCkaruvazhimadhapuratCoimbatore.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

227d08be-8df2-4541-a939-8dc52004554f.html

xls

BOQ_870378.xls

pdf

HSCkaruvazhimadhapuratCoimbatore.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender