Housing Urban and Rular Development Government Departments Closing in 1 days TDR #58490050

Tender For Renovation Of Pump House And Pipe Line At Dtw Scheme Braman Puskurini And Dtw Scheme Harinakhola Under Mohanpur Rd Block Within The Jurisdiction Of W.R. Sub-Division Mohanpur During The Year 2026-27. (Job No. Tr/43/Minor Works/Wrd-I/2025-2

Issued by Government Departments · tripura, Tripura
Tender Value
9.56 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
1 days left
EMD
19132
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Pump House And Pipe Line At Dtw Scheme Braman Puskurini And Dtw Scheme Harinakhola Under Mohanpur Rd Block Within The Jurisdiction Of W.R. Sub-Division Mohanpur During The Year 2026-27. (Job No. Tr/43/Minor Works/Wrd-I/2025-26)

BOQ

Name of Work:- Renovation of Pump house and pipe line at DTW scheme Braman Puskurini and DTW scheme Harinakhola under Mohanpur RD Block within the jurisdiction of W.R. Sub-Division Mohanpur during the year 2026-27. (Job No. TR/43/Minor Works/WRD-I/2025-26)
Sl. No. Item Description
1Dismantling GS sheet roofing including ridges, hips, valleys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m etc.complete as per direction of the Engineer-in-Charge.
2Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : i) Of area 3 sqm and below.
3Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials with all lifts and upto a lead of 50m etc.complete as per direction of the Engineer- in-charge:- i) In cement mortar
4Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level.i) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brick aggregate of 20 mm nominal size)
5First class brick work in foundation and plinth including cost of all materials as required complete:-i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).
6Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).
7Charges for fixing corrugated G.S. Sheet roofing fixed with polymer coated J or L hooks 8 mm diameter, bolts and nuts 6 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with lead and including a coat of approved steel primer and two coats of approved epoxy paint on overlapping of sheets complete ( upto a pitch of 60 degrees ) over a built structure including all types of necessary scaffoldings etc. but excluding the cost of the C.G.S. sheets, purlins, rafters and trusses etc.as per clauses of Chapter - 12 of CPWD specification. a) 0.63 mm thick with zinc coating not less than 275 gm / m2
8Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.i) 0.63 mm thick with zinc coating not less than 275 gm / m2
9Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:-Using flates 30 x6mm for diagonal braces and central cross piece.
10Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.i) Fixed to steel windows by welding.
11Steel work in built up tubular( round , square or ractangular hollow tubes etc) trusses etc. includng cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, in/c welding and bolted with special shaped washers etc.complete .i) Hot finished welded type tubes
1212 mm cement plaster of mixi) In Cement mortar 1:4 ( 1 cement : 4 fine sand )
13Neat cement punning .
14Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. all complete as per direction of Engineer in-charge.i) 40 mm thick with 20 mm well burnt brick aggregate
15Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
16Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:i) Two or more coats on new work
17Painting on G.S. sheet with synthetic enamel paint ( two or more coats ) of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : i) New work (two or more coats) including a coat of appropriate steel primer but excluding a coat of mordant solution
18Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge.
19Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineerin-charge.
20Providing and fixing G.I. Bend/elbow in the pipe line including testing of joints complete as perCPWD specification and direction of the EICi) 125 mm dia
21ii)150 mm dia
22Providing & fitting fixing MS tail piece with MS flange suitable forpipes complete as per CPWD Specification & direction of Engineer-in-charge.i) 125mm dia pvc pipe
23ii) 150 mm dia pvc pipe
24Providing and fixing CI sluice valve (with cap) complete with bolt , nuts ,rubber insertions etc. (the tail pieces if required will be paid separately) as per CPWD specification and direction of the Engineer-in -charge.(i) 100 mm dia. A. PN-1.6
25(ii) 125 mm dia A. PN-1.6
26(iii) 150 mm dia A. PN-1.6
27Providing & fitting fixing of M.S. flange (8mm thick wall thickness) by welding with G.I./ M.S. Pipe and placing position as per specification and the direction of the Engineer-in-charge.i) 150 mm dia
28ii) 125 mm dia
29Providing and fixing C.I. non-return valve of approved quality as per of CPWD specification and direction of the Engineer - in - charge.i)125 mm nominal bore
30Excavating trenches of required width for pipes cables etc in/c excavation for sockets & dressing side where required, ramming of bottom depth upto 1500mm (slope-1in 200) in/c getting out of the excavated soil and backfilling of soil as required after laying of pipe line, in layers not exceeding 200mm in depth in/c consolidating each deposited layers by ramming watering etc & disposing the surplus excavated soils with all required leads as per chapter-2 of CPWD specification and direction of the Engineer-in-charge.For UPVC pipes in new workA) All kinds of soil. a) For pipe not exceeding 90 mm dia .
31b) For pipes exceeding 90 mm dia but not exceeding 300mm dia .
32Providing and laying different dia rigid UPVC pipes of Working Pressure 4.0 kg/ sq.cm. complete with necessary coupler and solvent cement as per CPWD Specification & direction of Engineer-in-charge.i) 90 mm dia
33ii) 110 mm dia
34iii) 140 mm dia
35iv) 160 mm dia
36Providing and fixing GI. Pipes Medium class as per IS: 1239 with latest amendmentcomplete with GI. Fittings i/c trenching and refilling,cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer -in- charge.A. External work.i) 150mm dia nominal bore
37ii) 125mm dia nominal bore
38Providing and fitting fixing of G.I hydrant suitable for PVC pipes asper standard specification complete as per direction of Engineer-incharge (Rate excluding the cost of NTP control valve).i) 80X50 mm dia.
39Providing and fitting fixing of different dia rigid UPVC unequal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of Working pressure 4.0 kg/sq.cm confirming to IS: 10124 (Part-V) as per CPWD Specification & direction of Engineer-in-charge.i) 160x160x140 mm dia
40ii) 160x160x110 mm dia
41iii) 160x160x90 mm dia
42iv) 140x140x110 mm dia
43v) 140x140x90 mm dia
44vi) 110x110x90 mm dia
45Labour charge for repairing of leakage in existing UPVC distribution system including required earth cutting and fitting fixing of necessary coupler etc. complete and refilling the trench with available excavated earth as per direction of the Engineer-incharge. (Payment of couplers, tees, reducers etc will be made separately)i) 250 mm dia to 110 mm dia.
46ii) 90mm dia.
47Providing,fixing and laying fabricated UPVC socket/coupler conforming to IS:10124(Part 2) with solvent cement conforming to IS:14182 including testing of joints complete as per CPWD specification and direction of the Engineer in charge.i) 90 mm dia
48ii) 110 mm dia
49iii) 140 mm dia
50iv) 160 mm dia
51Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i) 160 x 140 mm dia
52ii) 140 x 110 mm dia
53iii) 110 x 90 mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58490050
AUTHORITY Government Departments
TENDER VALUE 9.56 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Renovation Of Pump House And Pipe Line At Dtw Scheme Braman Puskurini And Dtw Scheme Harinakhola Under Mohanpur Rd Block Within The Jurisdiction Of W.R. Sub-Division Mohanpur During The Year 2026-27. (Job No. Tr/43/Minor Works/Wrd-I/2025-26)
Basic Detail
Tender No 72_EE_WRD_I_DNIET_2026_27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 11 Nov 2026
Submission Date 18 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 9.56 Lakhs
Tender Fee 1000
EMD 19132
Exemption Not Available
Document List
bb5f99d4-df8f-47b1-a736-a9507ad515b7.html
BOQ_80384.xls
DNIeT_72_EE_2026_27.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

bb5f99d4-df8f-47b1-a736-a9507ad515b7.html

xls

BOQ_80384.xls

pdf

DNIeT_72_EE_2026_27.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender