Tender For Electrical Connection For New Icp-Oes In Room No.E-201, Minerals Processing Division At Amd Complex, Begumpet, Hyderabad
Tender Value
1.18 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
10 days left
EMD
2367
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Connection For New Icp-Oes In Room No.E-201, Minerals Processing Division At Amd Complex, Begumpet, Hyderabad
BOQ
| Sl. No. | Item Description |
| 1 | Notes:1. Before quoting, the bidder shall visit the site and make himself familiar with the site, nature, conditions and quantum / scope of work involved. You may contact Head, Construction & Engineering Services Group (Contact No: 040-27776 224/333) for site visit.2. The rates quoted shall include cost of all materials, labour, loading charges, unloading charges of feeder pillars, transportation, hoisting, tools, tackles & installation including all taxes (except EPF &ESI) and other charges if any. No extra payment over and above the rate quoted shall be made to the contractor in this respect. 3. The workers employed for the work shall strictly follow all safety measures as stated in safety code of this tender and also as per DAE safety code.4.The Contractor shall adhere to the provisions of applicable labour laws such as Contract Labour (Regulation & Abolition) Act, 1970, Minimum Wages Act, 1948, Employees State Insurance Act, Equal Remuneration Act, 1970 and rules made there under. 5.Contractor has to pay minimum wages, EPF & ESI to the manpower deployed for the work as per state/ central government orders issued from time to time. The actual amount paid towards EPF & ESI shall be reimbursed to him by the Department after satisfying that it has been actually and genuinely paid by the contractor. The bidder should not consider EPF & ESIC in his rates.6. The contractor shall ensure that all the persons executing the electricalwork have valid electrical license. 7. As the work required to be executed in functional office areas, there should be minimum inconvenience to the Officials. The work shall be programmed in consultation with the Engineer-in-charge. If so required, the work may have to be done even before and after office hours. No compensation shall be paid for loss of labour due to unavailability of site in any circumstances. |
| 2 | Removal of existing wiring in Lab including removal of incoming cable from Main DB to ICTP and wiring form ICTP to swicth board , Switch boards, socket outlets, circuit wiring etc after disconnection of mains and earth connections etc complete. The recess area of DB/ electrical boxes/ switch boards if any available after installing new DB/ switch boards is to be filled with cement concrete, necessary plastering & painting is to be done so as to match with the adjoining areas of wall on all sides, making the good, segregating and stacking the old removed items, including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C. |
| 3 | Supplying and fixing Distribution Boards (sheet steel, powder painted, complete with bus bars, neutral bar, earth bar, din bar & interconnections but without MCB/RCCB/Isolator unless stated) |
| 4 | 4 way (4+12), Double door, Vertical type, 415V TPN MCB Distribution Board |
| 5 | 8 way, Double door, single pole & neutral (SPN), 240V MCB Distribution Board |
| 6 | Supply and fixing DP sheet steel enclosure on surface/ recess along with 25/32A, 240V \\"C\\" curve DP MCB, complete with connections, testing & commissioning |
| 7 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 8 | Supplying and fixing 32 A, 240 V, SPN Industrial type socket outlet with 2 pole and earth, metal enclosed plug top along with 32 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 9 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 10 | Single Pole |
| 11 | Triple Pole |
| 12 | Supplying and fixing 40 A, Single Pole MCB, 10kA \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | Supplying and fixing 63 A, Four Pole MCB, 10kA \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 14 | Supplying and fixing 40 A, Double Pole (Single Phase & Neutral), 240V, Residual Current Circuit Breaker (RCCB), sensitivity 30 mA, complete with connections, testing & commissioning etc. as required |
| 15 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC medium class conduit as required |
| 16 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 17 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 18 | Supply and fixing of heavy duty long barrel copper lug, ISI/IS specification, up to 16 sq.mm cable, complete with nuts, bolts & washers, for cable end termination |
| 19 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV garde of up to 35 sq.mm( clamping with 1 mm thick saddles) on service duct/ wall surface complete as required. |
| 21 | Supply and fixing of heavy duty type single compression brass cable glands duly nickel plated complete with brass checknut, outer sheath sealing rubber ring and washers suitable for Up to 16.0 Sq.mm 4 Core XLPE insulated armoured cable, including all labour charges and miscellaneous items etc complete. |
| 22 | Supply of 3 Core × 10 sq.mm Copper Multi-Core FRLS Flexible Cable, 1100 V grade, with stranded bright annealed copper conductors, PVC insulation and FRLS PVC outer sheath, conforming to IS 694:2010, suitable for power distribution, complete as required. |
| 23 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C. |
| 24 | 5/6 A switch |
| 25 | 15/16 A switch |
| 26 | 3 pin 5/6 A socket outlet |
| 27 | 6 pin 15/16 A socket outlet |
| 28 | Supplying and fixing 12 Module (200mmX150mm), GI box along with modular base & cover plate for modular switches in recess etc. asrequired. including cost of materials, labour, tool &plants, taxes etc as per the instructions and directions of E-I-C. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender