Tender For Construction Of Odisha Blue Economy Hub At Matsya Sadan Cuttack Road, Bhubaneswar Khurda.
Tender Value
34.85 Crore
Estimated cost
Bid Submission
01 Dec 2026
10 days left
EMD
34.85 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Odisha Blue Economy Hub At Matsya Sadan Cuttack Road, Bhubaneswar Khurda.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Nov-2026 | CHANGE IN DTCN CLAUSES | Technical Bid | 01-Dec-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | 10000556Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories,tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).(Icluding both LABOUR FOR DRILLING 200MM DIA UPTO 30 MTR. & LABOUR FOR DRILLING 150MM DIA FROM 30 MTR TO 150 MTR including all.) CONSIDER FOR 150 MTR DEPTH.Ground Floor |
| 2 | 10000564Lowering 200mm dia. PVC pipes with or without slotted pipes as per the necessity from ground level with fitting and fixing the same in a perfectly vertical position. This includes cutting, threading pipes/slotted pipes with providing and fixing of required jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells so as to prevent entry of foreign materials from above. (FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG).(Make-Oriplast, Hariplast ,Supreme, Finolex)Ground Floor |
| 3 | 10000570Cleaning and developing 200mm dia. tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour .(FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG).Ground Floor |
| 4 | 10000583Supplying and fixing of control panel board with all accessories. (UPTO 3HP SINGLE PHASE) Make: KSBGround Floor |
| 5 | 10000588Supplying and fixing of HDPE Pipes 32/40 mm (High Density Polyethylene pipes having inner dia. 32mm and outer dia. 40mm) 6Kg/Sq. cm With IS specification.(32MM NOMINAL BORE SIZE). Make Finolex/Oriplast/Supreme/Hariplast.Ground Floor |
| 6 | 10000594Supplying and fixing of PVC coated steel rope including cost of material, labour etc. complete. Make-Mahdev/AerolexGround Floor |
| 7 | 10000596Supplying and fixing of Finolex/L&T/Cable 4 Sq. mm (3core copper wire flat cable with PVC insulation).Ground Floor |
| 8 | 10000600Supplying and fixing of accessories like Nipple, Bore cover, MS clamp, Nut Bolt, Stainless steel nipple, Short piece, GI bend, Socket etc. complete.Ground Floor |
| 9 | 10000602Installation charges pump set with all accessories including transportation etc.Ground Floor |
| 10 | 10001184Supplying of 200mm inner dia. PVC casing pipe for deep bore well CD (deep well casing) type basing on IS-12818-2010, wall thick ness 13mm to 14.8mm with One end of the pipe is male-threaded whereas the other end is a female-threaded socket. Threads are either V-type or trapezoid-type, and protection caps are provided on the threads to protect the threads in transit. With pressure ratings ranging from 7.5 to 20 bar (PN). Make: ORIPLAST/SUPREME/FINOLEX/HARIPLASTGround Floor |
| 11 | 10001190Supplying Submersible Pump Set with the cost of Motor of following model including cost of transportation charges.1.5HP, Single phase,32D,19 Stage (head 50-129m). Make: KSB(2C/21).Ground Floor |
| 12 | 40000952Recessed wiring to Calling Bell Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular bell push ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-bell push switch-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 13 | 40000955Recessed wiring to Bulk Head Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 14 | 40000958Recessed wiring to Television Point (Modular)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/TV socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK).Ground Floor |
| 15 | 40000961Recessed wiring to Telephone Point (socket)with 2 pair 0.5sqmm telephone cable with 20 mm dia non metalic PVC flexible conduit with socket ISI marked MS Box including all accessories and connection.( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-s witch-Telephone socket -Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK).Ground Floor |
| 16 | 40000982Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 17 | 40000985Point wiring for 5/ 6 amp socket outlet ( Separate) ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 18 | 40000988Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 19 | 40000991Point wiring for Computer Point ( MODULAR) with 2.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with3 Nos of 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 20 | 40001000Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI/RR/POLYCAB) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 21 | 40001003Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI/RR/POLYCAB) CSR SL .No- 1.8.3)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 22 | 40001012Recessed wiring to submain in 4 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI/RR/POLYCAB) CSR SL .No- 1.8.10)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 23 | 40001033Supply and laying of 25 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/Polycab/KEI/Gloster)Ground Floor |
| 24 | 40001045Supply and laying of 95 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI/Gloster)Ground Floor |
| 25 | 40001051Supply and laying of 150 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI/Gloster)Ground Floor |
| 26 | 40001129Supplying and fixing of 6\\"X4\\" 16/18 swg,2 \\" deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam)Ground Floor |
| 27 | 40001132Supplying and fixing of 8\\"X6\\" 16/18 swg,2 \\" deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-(National / Royalam)Ground Floor |
| 28 | 40001135Supplying and fixing of 8\\"X10\\" 16/18 swg,2 \\" deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5)(Make-(National / Royalam)Ground Floor |
| 29 | 40001141Supplying and fixing of two modular GI Box 18 swg with Modular base & cover for 2 module (Sl. No- 1301,1421)(Make-switch/Socke t-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 30 | 40001145Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 31 | 40001148Supplying and fixing of 6 modular GI Box 18 swg with Modular base & cover for 6 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 32 | 40001151Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 33 | 40001154Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells)Ground Floor |
| 34 | 40001190Supplying and fixing of Call Bell/buzzer ISI marked suitable for DC/AC single phase 230 volts complete as required (CSR sl no-1.30)Ground Floor |
| 35 | 40001193Blanking Plate(Make-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells)Ground Floor |
| 36 | 40001258SUPPLY & FIXING OF POWER DISTRIBUTION BOX,MAKE-NET RACK/VAL RACKGround Floor |
| 37 | 40001708Wiring to Loudspeaker with 2x1.5 sqmm stranded copper conductor unarmoured cable for loud speakers clamped with PVC pipe saddles,base etc.on ceiling/wall complete including termination,testing etc as required (Make-Finolex/Anchor/Havells/V-guard)Ground Floor |
| 38 | 40001709Installation,testing,commissioning charges of audio system.Ground Floor |
| 39 | 40001876Supply and fixing of 16 Amp top(for inverter installation) with all accessories and conncetion(Make-Legrand/wipro/Anchor-Panasonic)Ground Floor |
| 40 | 40001879Recessed wiring in 1X1.5sqmm (For inverter)/DG wiring )FR PVC insulated single core multistrand copper conducter of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick as per direction of Engineer in charge(Make of wire Finolex/Anchor/Havells/V guard)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 41 | 40002035Point wiring for Instrument Point ( MODULAR) with 4.0 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 2 Nos of 5 Amp, and 1 no of 15 amp modular type 250 V modular switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc as required as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)Ground Floor |
| 42 | 40002095Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL/VTR All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor |
| 43 | 40002146Supply and laying of 10 sq.mm 4 core copper flexible cable from Panel to AC out door Unit.Ground Floor |
| 44 | 40002185Supply and laying of 300 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(Make Cable- Finolex/ Havells/Polycab/KEI/Gloster)Ground Floor |
| 45 | 40002564Recessed wiring to Secondary Ceiling Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L <(><<)>(>&<(><<)>)>T / Anchor / Havels/ V guard)Ground Floor |
| 46 | 40002791Supply and fixing of Cable Tray 12 inch including all accessories and connections as per instruction of Electrical Engineer-in- ChargeGround Floor |
| 47 | 40003240Supply and fixing of LED Strip light OUT DOOR TYPE complete set including casing & all accessories refer to catalouge MAKE – WIPRO MODEL – LS27-005-120-WW-50/ SIMILAR TO HAVELLS/PHILIPS including fixing and connections as per instruction of Electrical E ngineer-in-charge .Ground Floor |
| 48 | 40004779Supply and laying of 50 x 6 mm GI flatGround Floor |
| 49 | 40004781Supply and laying of 25 x 6 mm GI flatGround Floor |
| 50 | 40006334Supply & fixing of 6 Way VTPNDB IP 43-Metal Door Incoming: 1 No of 125 A Four Pole MCCB with stud connector Outgoing: 6nos 63 A TPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.6,2.7, )[Make-(a)MCB /MCCB -Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC )Ground Floor |
| 51 | 40006336Supply & fixing of 6 Way VTPNDB IP 43-Metal Door Incoming: 1 No of 100 A Four Pole MCCB with stud connector Outgoing: 6nos 40 A TPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.6,2.7, )[Make-(a)MCB /MCCB -Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC )Ground Floor |
| 52 | 40006387Supply & fixing of 4Way VTPNDB IP 43-Metal Door Incoming: 1 No of 63 A Four Pole MCCB with stud connector Outgoing: 3 nos 32 A TPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.6,2.7, )[Make-(a)MCB /MCCB -Legrand/L <(><<)>(>&<(><<)>)>T/ABB/SCHNIDER/ANCHOR-PANASONIC )Ground Floor |
| 53 | 40006865Supply and laying of 300 sq.mm 3.5 core End termination for Cableof 1.1 KV grade ISI MarkedGround Floor |
| 54 | 40008124Supply & fixing of 400mm (16\\") wall mounted fan with complete accessories[brown/white].including hanging and connections [MAKE- USHA MODEL-MIST AIR DUOS/ CROMPTON MODEL-TROPEDO HI SPEED//HAVELLS/V-GURAD MODEL-PETAL WF 17/ANCHOR)Ground Floor |
| 55 | 40008126Supply and fixing of 250 mm sweep air ventilating fan with Louvers (PVC BODY) fan with connecting wire and all accessories including fixing and connections . [MAKE- USHA MODEL-CRISP AIR VX/CROMPTON MODEL-VENTILUS/HAVELLS/ANCHOR)Ground Floor |
| 56 | 40008136Supply and fixing of 450 mm sweep exhaust fan Heavy duty with connecting wire and all accessories including fixing and connections as per instruction of Electrical Engineer-in-charge. [MAKE- USHA MODEL-TURBO HD 1400 RPM/ CROMPTON MODEL-EXHD450-4-1 NEO/V-GUARD MODEL-SHOVAIR S18(HEAVY DUTY)/HAVELLS/ANCHOR-PANASONIC)Ground Floor |
| 57 | 40008142Supply and fixing of 6 way mcb Box ( 8+18)(BDB) with I/C- 32 AMP 4PMCB & O/G-25AMP DP RCCB (100MA)-3 NOS&10 AMP SP MCB -12NOS with sheet steel encloser ,distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection ,phosphate and power painted including earthing etc as required.Make-MCB-(Legrand/L &T/ABB/SCHNIDER)Ground Floor |
| 58 | 40008150Supply and fixing of 6 way mcb Box ( 8+18)(PDB) with I/C- 63 AMP 4PMCB + 63 AMP 4P RCCB (300MA) & O/G- 20 AMP SP MCB -09 NOS&16 AMP SP MCB -09NOS with sheet steel encloser ,distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection ,phosphate and power painted including earthing etc as required.[Make-(a) MCB/MCCB-Legrand/L&T/ABB/SCHNIDERGround Floor |
| 59 | 40008158Supply and fixing of 1200 mm BLDC (ISI mark 5 star rated)(28wt with aluminium blade)ceiling fan (without remote) with connecting wire and all accessories including hanging and connections .- [MAKE- USHA MODEL-TECHNIX/ CROMPTON MODEL-ENERGIA GROOVE /V-GUARD /HAVELLS MODEL-EFFICIENCIA NEO/ANCHOR-PANASONIC MODEL-PENTA TURBO)Ground Floor |
| 60 | 40008481Supply of wall mounted speaker make- Ahuja (ASX-312bt) including all accessories.Ground Floor |
| 61 | 40008485Supply of Central amplifier Make-Ahuja(CMA-5400) including all accessoriesGround Floor |
| 62 | 40008487Supply of Audio amplifier Make-Ahuja(SSA-250DP) including all accessoriesGround Floor |
| 63 | 40008495Supply of 6U wall mounted rack including all accessories and connection(make-D-link(Model no-NWR-6U-5545-GR)/MOLEX/DIGISOL)Ground Floor |
| 64 | 40008505Supply & fixing of cat-6 UTP cable,4 pair,23AWG,FRPVC CM for LAN wiring with conduit pipe / PVC casing caping / under floor G.I. Tunk line. MAKE- D-LINK(MODEL NO-NCB-C6UGRYR)/DIGISOL/MOLEX)Ground Floor |
| 65 | 40008507Supply & fixing of patch cord,cat-6,utp,24awg,grey,lszg ,1mtr(Make-D-LINK(MODEL NO-NCB-C6UGRYR1-1-LS)/DIGISOL/MOLEX)Ground Floor |
| 66 | 40008509Supply & fixing of patch cord,cat-6,utp,24awg,grey,lszh ,2mtr(Make-D-LINK(MODEL NO-NCB-C6UGRYR1-3-LS)/DIGISOL/MOLEX)Ground Floor |
| 67 | 40008511Supply & fixing of information outlet with faceplate,single port ,modular straight shu and keystone,cat-6 utp,white,toolless type(MAKE-D-LINK/MOLEX/DIGISOL)Ground Floor |
| 68 | 40008513Supplying & fixing of patch panel ,24 PORT,CAT-6 UTP 180 Degree including all accessories and connections(Make-D-Link(Model N o-NPP-C61BLK241)/MOLEX/DIGISOL)Ground Floor |
| 69 | 40008586Supply and fixing of 24 Port Gigabit Smart Managed Switch with 4 Gigabit SFP Ports including all accessories and connection(Make-D-LINK(MODEL NO-DGS-1210-28)/DIGISOL (MODEL NO-DG-GS1528)/MOLEX)Ground Floor |
| 70 | 40009223Supply and fixing of 6Wt Spot light connecting wire, and all accessories and connections .( Make- CROMPTON(MODEL NO-CDR-210-06-30/40-SL-NWH/ PHILIPS(MODEL NO-7W COB PRO / WIPRO(MODEL NO-LD98-900-024-40-G1)Ground Floor |
| 71 | 40010259Supply of Recess Linear 17mm Linear : 25W-30W, Colour:3000K, Protection Rating : IP65, Beam Angle : 120˚. Body : Extruded aluminium, Power Loopin and Loop out for easy of connections, Power Input : DC 24V (without DC Driver & Decoder)((Make- CROMPTON/PHILIPS/ WIPRO/JAQUAR/HAVELLS/PANASONIC)Ground Floor |
| 72 | 40010758Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections (Make- PANASONIC(MODEL NO-PBTM012 07)/HAVELLS(MODEL NO-PHOTON ULTRA)/CROMPTON(MODEL NO-CCS-102-20-65-SL-DP-NWH/ PHILIPS(MODEL NO-SLIMLINE NEXT 4'/ WIPRO(MODEL NO-LL20-221-XXX-65NE3)Ground Floor |
| 73 | 40010880Supply & installation of 60KVA (3Ph-3Ph) online UPS aith SMF battery back up upto 30 minutes with battery bank and rack (Make -APC/Numeric)Ground Floor |
| 74 | 40011146Supply and fixing of Bulk Head fitting with 10/12 wt. LED Bulb including all accessories and connections . (Make- PANASONIC(PMHM01107 / HAVELLS-RUGB4GENX10W960)Ground Floor |
| 75 | 40011679Providing & fixing Smart LED TV ( Sony Bravia 4K - 65 '' ) Model No KD-65X 82L inclusive of all necessary hardwares, T&P etc. complete including all accessories and connections.(Make-Sony/LG/SAMSUNG)Ground Floor |
| 76 | 40011787Supply and fixing of on 15 watt round/square shape slim recessed mounted led panel with dia cast housing finished in white powder coating False ceiling with comprises of aluminium die cast housing finished in white powder coated & ABS white ring . The downlighter is pre-wired with high efficiency electronic driver. High traslucent frosted diffuser is used to get glare free, smooth light distribution. Operating Voltage Range : 150V~ - 270V, PF : > 0.9, 100 Lum/Watt with lamp , choke, connecting wire, and all accessories and connections .( Make- CROMPTON(MODEL NO-LSCRM-15W-CDL/LSCSM-15W-CDL)/ PHILIPS(MODEL NO-15W DURASLIM ROUND/SQUARE 165MM/WIPRO(MODEL NO-LD80-131-XXX-60-XX)/PANASONIC MODEL NO-PPAM12156BS/HAVELLS MODEL NO-OCTANE)Ground Floor |
| 77 | 40011789Supply and fixing of on 34/36watt square (2'x2')shape slim recessed mounted led panel with dia cast housing finished in white powder coating False ceiling with comprises of aluminium die cast housing finished in white powder coated & ABS white ring . The downlighter is pre-wired with high efficiency electronic driver. High traslucent frosted diffuser is used to get glare free, smooth light distribution. Operating Voltage Range : 150V~ - 270V, PF : > 0.9, 100 Lum/Watt with lamp , choke, connecting wire, and all accessories and connections .( Make- CROMPTON(MODEL NO-TCR-145-36-65-SL-NWH (36 WATT)/PHILIPS(MODEL NO-RC360B LED36S 36W 3600)/WIPRO(MODEL NO-CRCO10R038HP57G3)/PANASONIC MODEL NO-PBLM22367/HAVELLS MODEL NO-PLANO2X2PLR34/36W)Ground Floor |
| 78 | 40012080Recessed wiring to (GROUP-A) Light Point/fan point/exhaust fan point/call bell point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 79 | 40012082Recessed wiring to (GROUP-B)Light Point/fan point/exhaust fan point/call bell point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 80 | 40012084Recessed wiring to (GROUP-C)Light Point/fan point/exhaust fan point/call bell point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 81 | 40012194Main Distribution Board -Incoming power Distribution panel/ board suitable for flush mounted type made of 14 SWG sheet with MS angles channels suitable sizes, gasket, powder coated, top & bottom terminals and properly painted with anticorrosive primer and paints, comprising the following: [Make-(a) MCB/MCCB- Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC(b)-Voltmeter, Ammeter-AE/CAPPA (d) all other acessories ISI mark] Incoming- 1 No 200 Amp FP MCCB [35 kA] Busbar : 4 Nos 400A, 500V Electrolytic copper strips Outgoing - 8 nos 63Amp 4PMCCB ,Instrument-Multifunction meter,Indicator-1. Multi-function meters showing voltage, current, pf, frequency, MD and THD with required 500/5A CTs 03 Nos : LED type phase indicating lamps with control fusesGround Floor |
| 82 | 40012918Supply and installation of AC Terrace panel for flush mounted type made of 14 SWG sheet with MS angles channels suitable sizes, gasket, powder coated, top & bottom terminals and properly painted with anticorrosive primer and paints,comprising the following: [Make-(a) MCB/MCCB- Legrand/L&T/ABB/SCHNIDER/(b)-Voltmeter, Ammeter-AE/CAPPA (d) all other acessories ISI mark] Incoming- 400 A 4P MCCB, MP Based/OL/SC/U/STRelease(36KA)- 1 No, with FP spreader and Extended ROM ,indicator(R,Y,B),2A SPMCB C-Curve,Digital Voltmeter,Digital Ammeter,400/5A CT,auxillary for MCCB wit meterspace and wiring Digital Amperemeter-1 Set,Indicator- 3 Nos,6A Glass fuse-3 Nos,400/5 CT-3 Nos, Outgoing- 63A 4PMCB- 9 Nos. ,63A 4P RCCB(300ma)-9 Nos, 25A DP RCCB-1 No & 10A SPMCB-3 Nos & Acessories-Panel Duly fabricated & wired with BusbarGround Floor |
| 83 | 40013358Providing and fixing of 18 wt. LED COB Light fitting with lamp , choke, connecting wire, and all accessories and connections .( Make-CROMPTON)MODEL NO-CDR-210-18-30/40-SL-NWH/WIPRO(MODELNO-LD98-271-024-40-G1)/PHILIPS(MODEL NO-18W COB PRO)/PANASONIC(MODEL NO-PDLM33187)/HAVELLS(MODEL NO-UNECO ADJUSTABLE)Ground Floor |
| 84 | 40013382Supply, Installation, Testing, & Commissioning of PANEL: Screen Size (Inch):110\\", Panel Technology: ADS, Back Light Type:Direct, Aspect Ratio:16:9, Native Resolution:3840 x 2160 (UHD),Refresh Rate:60Hz, Brightness:500ni t (Typ.), Contrast Ratio:1,200:1, Dynamic CR:100,000:1, Color. Make-LG(Model-110UM5K)/SAMSUNG(Model-QHFX-115\\")Ground Floor |
| 85 | 40013460Main Distribution Board-Incoming power Distribution Panel/board suitable for flush mounted type made of 14 SWG sheet with MS angles channels suitable sizes,gasket,powder coated,top & bottom terminals and properly painted with anticorrosive primer and paints,comprising the following [Make-(a)MCB/MCB Box-LEGRAND/ L &T/ HAVELLS/ SCHNIDER /C & S/HPL/ANCHOR-PANASONIC (b) meter,Ammeter-AE/CAPPA(c)all other acessories ISI mark] Incoming- 1 No 1000Amp FP ACB,65KA,EDO,TYPE-H Busbar:4 Nos 1000A,500V Electrolytic copper strips(25kg), Indicator(R,Y,B)-3 Nos,SPD-100KA,Type-1+2 with MCB ,01 No Multifunction meters showing voltage,current,pf ,frequency ,MD and THD required CTs Outgoing: 12 Nos 100A FPMCCB (25 KA) 6 Nos 125A FP MCCB(25KA) 5 Nos 400A FPMCCB(25KA) 3 Nos 200A FP MCCB with stud connector(UPS,FIRE & SPARE) 5 Nos 400 A 4P MCCB, MP Based/OL/SC/U/STRelease(36KA)- 1 No, (AC terrace panel-2,capacitor bank-1 No,Spare-2) 4 Nos of 63A 4PMCB with panel duly fabricated & wired with busbarGround Floor |
| 86 | 40013464Supply and fixing of 20WT Pendent light including alll accessories and connection.MAKE-PHILIPS(MODEL-5820201/WIPRO(MODEL-LM86-D400- BLGD)/PANASONIC(MODEL-PDLM20254 /HAVELLS(UNECOPENDDLP20WLED857S36BLK-G2)/CROMPTON (MODEL-TCP-145-20-57-HL2-DP-12-NWH)Ground Floor |
| 87 | 40013470APFC PANEL Supply,installation, testing & commissioning of Auto Power Factor Correction Relay (APFCR-170KVAr) suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, gland plates at top/bottom for control cables, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Make-L&T/Schneider/ABB/LegrandGround Floor |
| 88 | 40013473Supply and installation of 1 No 1000Amp FP onload changeover switch with accessories.Main for flush mounted type made of 14 SWG sheet with MS angles channels suitable sizes,gasket,powder coated,top <(><<)>(>& <(><<)>)> bottom terminals and properly painted with anticorrosive primer and paints,comprising the following [Make-(a)MCB/MCB Box-LEGRAND/ L <(><<)>(>&<(><<)>)>T/ HAVELLS/ SCHNIDER /C& S/HPL/ANCHOR-PANASONIC (b) meter,Ammeter-AE/CAPPA(c)all otheracessories ISI mark] with panel duly fabricated <(><<)>(>&<(><<)>)> wired with busbarGround Floor |
| 89 | 10000294Laying in trenches OD PVC pipes and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by non-heat application method including testing as per specification complete. 110mm dia OD P.V.C SWR double socket pipes (ISI TYPE-A),Analysis is done as per AR-2013,SL NO-2.3.2 .Ground Floor |
| 90 | 10000378Supplying , fitting & fixing of CP Toilet paper holder fixed to plugs with Chromium plated brass screw all complete as per specification.Toilet Paper Holder(AEC-CHR-1151N)(Weight- 0.28 kg)Plating: Nickel-8.0 micron, Chromium-0.20 micron,In ESSCO Nitrile rubber O-rings are used and these are long lasting.,Warranty 10 years for all commercials and domestic uses .or equivalent product of Parryware / CeraGround Floor |
| 91 | 10000618Supplying, Fitting & Fixing of Liquid Soap Dispenser with all complete, Ready to use or Ready made by approved brands of Jaquar, Parryware, Cera, Hindware etc as per the instruction of EIC.Ground Floor |
| 92 | 10001046Providing & Fixing MANHOLE COVER SIZE 1'0\\"X1'0\\" all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Architect / Engineer-in-charge. [NEW-NSWI]Ground Floor |
| 93 | 10001056Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 mtr. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 20 mm outer dia CPVC pipes.Ground Floor |
| 94 | 10001058Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 25 mm outer dia CPVC pipes.Ground Floor |
| 95 | 10001060Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 40 mm outer dia CPVC pipes.Ground Floor |
| 96 | 10001062Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 50 mm outer dia CPVC pipes.Ground Floor |
| 97 | 10001064Laying in trenches/fixing on walls UPVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by push fit method; water tightness joint test 0.5Kg/sq.cm/15min as per specification complete. (Earth work in trenches to be measured and paid for separately). 110mm dia. SWR pipe of Single Socket Push fit of class-3 (6Kg/Sq.cm). Make:- ORIPLAST/SUPREME/FINOLEX. 110mm dia. UPVC pipe, Class-3 (6Kg/Sq.cm).Ground Floor |
| 98 | 10001066Laying in trenches/fixing on walls UPVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by push fit method with water tightness joint test 0.5Kg/sq.cm/15min as per specification complete. (Earth work in trenches to be measured and paid separately). 160mm dia. rigid UPVC SWR pipe Class- 3 (6Kg/Sq.cm). Make: ORIPLAST/SUPREME/FINOLEX. 160mm dia. UPVC pipe, Class-3 (6Kg/Sq.cm).Ground Floor |
| 99 | 10001068Providing and fixing on wall face PVC 110 mm dia. offset SWR moulded fittings / accessories for PVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. offset PVC SWR type.Ground Floor |
| 100 | 10001070Providing and fixing on wall face 110mm dia. single junction with door PVC SWR type moulded fittings, accessories for Rigid UPVC SWR pipes conforming to IS : 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion . Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Single Junction with door PVC SWR type.Ground Floor |
| 101 | 10001072Providing and fixing on wall face 110mm dia. plain bend PVC SWR type moulded fittings / accessories for Rigid UPVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Plain Bend PVC SWR type.Ground Floor |
| 102 | 10001074Providing and fixing on wall face 110mm dia. bend with door PVC SWR type moulded fittings / accessories for rigid UPVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Bend with door PVC SWR type.Ground Floor |
| 103 | 10001076Providing and fixing on wall face 110 mm dia. cowel PVC SWR moulded fittings / accessories for PVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. cowel PVC SWR type.Ground Floor |
| 104 | 10001078\\"Fixing 110mm dia GULLY Trap P.V.C SWR TYPE of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification. make: ORIPLAST/SUPREME/FINOLEX. 110mm Dia Gully trap PVC SWR typeGround Floor |
| 105 | 10001080Providing and fixing 110mm dia. PVC Nahani Trap without jally of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls/ floors all complete as per specification. Make: ORIPLAST/SUPREME/FINOLEX. 110mm dia. PVC Nahani trap without jallyGround Floor |
| 106 | 10001084Providing and fixing 110 mm dia. PVC SWR P-Trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. P - trap PVC SWR type.Ground Floor |
| 107 | 10001088Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc. all complete as per specification with 1:4 brick work in cement mortar (1:4) and 12mm thick cement plaster. For 250mm thick wall.Ground Floor |
| 108 | 10001094Cutting holes in R.C.C floor and roofs up to 19cm thick for passing G.I/PVC pipes and fittings etc. and repairing the hole after insertion of pipes etc. with cement concrete (1:2:4) including finishing complete so as to make it leak proof. Details cost of 1 hole of average size 15cm X 15cm X 25cm.Ground Floor |
| 109 | 10001096Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete, with cement concrete (1:3:6) and 12mm cement plaster (1:3) along with Cement punning.Ground Floor |
| 110 | 10001098\\"Fixing floor traps of the following nominal diameter of outlet of self cleaning design with serewed down or hinged grating with or without vent arm complete includingcost of cutting and making good the walls and floors all complete as per specification. 110mm INLET & OUTLET FLOOR TRAP.make: ORIPLAST/SUPREME/FINOLEX \\"110mm Dia Inlet & Outlet floor trap PVC SWR type.Ground Floor |
| 111 | 10001102Fixing of Back to wall WC with UF soft close seat cover, hinges, accessories set with rack bolt 12mm dia stainless steel Size(360x51 5x410mm) (FOR DISABLED) Floor Mounted to the floor fixed to head less socket caps/wall plugs and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification WITHOUT CISTERN. make: JAQUAR (DIS-WHT-9 3955P180UF)/ KOHLER(K-2983IN-S-O) DISABLED PERSON COMMODEGround Floor |
| 112 | 10001116Providing and Fixing PVC LOW LEVEL CYSTERN conforming to IS 2556 : Part 3- 2004 SIZE 415X130X305mm.Make: Hindware SUPERB (CAT NO-50 8829)/Parryware SLIMLINE ECONOMY (E-8090).White Vitreous china 10 litre (full flush) capacity manually controlled low level flushing cistern with all fittings and fixtures.Ground Floor |
| 113 | 10001118Providing and fixing stainless steel kitchen sink with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Size 600X450X225mm Steel Sink Matt single bowl. Make: (Parry ware(C857272)/Hindware(KS FLAMINGO)). Stainless steel kitchen sink - 600X450X225mm Single bowl.Ground Floor |
| 114 | 10001120Providing and fixing wash basins full pedestal with hole for pillar taps with 10mm dia. M.S. rack bolt painted white including cutting holes in walls and making good the damages etc. all complete, with fixing of 15mm dia. pillar cock,32mm dia. CP waste,15mm dia. PVC Reinforced heavy duty connection pipe, 32mm dia. PVC connection pipe, complete as per specification. Vitreous china flat back wash basin size 550x400x200 mm). Make: JAQUAR(CODE for Basin- CNS-WHT-801, for Full Pedestal -CNS-WHT-301, for Pillar cock-CON-021, for 32mm full/half thread CP wast e-ALD-705/709, for Rack bolt-ZPS-MST-RB03). Vitreous china flat back wash basin 550x400x200mm.Ground Floor |
| 115 | 10001124Providing and fixing of 25mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 25 mm dia. CPVC Full Way Valve / Ball Valve.Ground Floor |
| 116 | 10001126Providing and fixing of 40mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 40 mm dia. CPVC Full Way Valve / Ball Valve.Ground Floor |
| 117 | 10001128Providing and fixing of 50mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 50 mm dia. CPVC Full Way Valve / Ball Valve.Ground Floor |
| 118 | 10001132Providing and fixing of 15mm dia. CP Screw-down two way Bib Cocks (Taps)polished bright with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux headand high quality). Make: JAQUAR( CON-041KN)/ KOHLER (K-25432IN-4-CP). 15mm dia. Two-way Short body bib cock.Ground Floor |
| 119 | 10001136Providing and fixing of 15mm dia. CP Screw-down angle Stop Cocks with flange of the following nominal sizes as per specification complete. (Deluxe Head and high quality). Make: JAQUAR (CON-059KN))/ KOHLER (K-11568IN-7B-CP). 15mm diameter Angle Stop Cock.Ground Floor |
| 120 | 10001146Providing and fixing of health faucet with 1.2m long PVC tube and wall hook. Make: JAQUAR (ALD-563) including all complete as per specification. 1.2m long PVC tube CP health Faucet.Ground Floor |
| 121 | 10001148Providing and fixing Stainless Steel soap dish holder fixed to head less socket caps, wall plugs with CP brass screws as per specification. Make: JAQUAR (ACN-1131N))/KOHLER (K-10712D-CP). Stainless Steel Soap Dish Holder.Ground Floor |
| 122 | 10001150Providing and fixing of 600x120 mm glass Shelf with anodised aluminium angle frame with chromium plated brassbrackets and guard rails of required size complete, fixed to head less socket caps, wall plugs with chromium plated brass screws as per specification. Size 600x120 mm glass shelf. Make: AQUAR-(ACN-1171N)/ KOHLER(K5636IN-CP). 600mmX120mm Glass Self.Ground Floor |
| 123 | 10001152Providing and fixing standard sized stainless steel towel rail of 600mm long complete with Chromium Plated brass brackets; fixed to head less socket caps, wall plugs with Chromium Plated brass screws, complete as per specification. (Make: JAQUAR (ACN-1111SM)/ KOHLER (K-5630IN-CP),(Heavy quality). 25 x 600 mm long SS Towel Rail.Ground Floor |
| 124 | 10001154Providing and fixing standard sized stainless steel towel ring with round flange complete with Chromium Plated brass brackets; fixed to head less socket caps/wall plugs with Chromium Plated brass screws, complete as per specification. Make: JAQUAR (ACN-1121BN) /KOHLER (K-5631IN-CP). SS Towel ring with round flange.Ground Floor |
| 125 | 10001158Providing and fixing 600 mm x 450 mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to head less socket caps, wall plugs and washers complete as per specification.(AR-2013,SL. NO.-3.4.26). Make: Mirror Glass (SAINT GOBIN/AIS(ASAHI)). 600mm x450mm Bevelled Edge Mirror (Heavy quality).Ground Floor |
| 126 | 10001160Providing & Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing cpvc tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification .(MAKE:- SUPREME/SINTEX /ORIPLAST BRANDS) Triple Layer Cylindrical Vertical water storage tanks.Ground Floor |
| 127 | 10001162Extra over (item No 3.1.8 as per A.R 2013) for hoisting Rotational moulded polyethylene cylindrical vertical water storage tanks of the following size for every additional height of 5 metres or part there of installation on roof as per the requirement and site condition.Ground Floor |
| 128 | 10001172Providing and fixing of 692mm long stainless steel grab bar handle (FOR DISABLED)fixed to head less socket caps, wall plugs and chromium plated screws as per specification . Make: JAQUAR (WAC-WHT-BR0600N) 692mm long stainless steel grab bar handle.Ground Floor |
| 129 | 10001174Providing and fixing of stainless steel vertical swing grab bar (FOR DISABLED) fixed to head less socket caps, wall plugs and chromium plated screws as per specification. Make: JAQUAR (WAC-WHT-BG0800N) Stainless steel vertical swing grab bar.Ground Floor |
| 130 | 10001209Providing and fixing curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish size H:900XW:450mm with stainless Steel brackets including cutting holes in wall and making good the damages etc. complete as per specification. Make: JAQUAR (JSE-CHR-110UC450X/110US450X). Curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish.Ground Floor |
| 131 | 10001292Providing and fixing circular type stainless steel grating with hole for floor /nahani trap etc complete as per PH specification and direction of the engineer in charge.Ground Floor |
| 132 | 10001332Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Man hole chamber Inside size 910mmx910mmx910mmGround Floor |
| 133 | 10001342Fixing of standing urinal including connecting the urinal with waste pipe by means of white chopped hemp etc all complete as per spe cification.(White vitreous china clay half stall urinal flat back 476x316x715 mm Make:-JAQUAR(URS-WHT-13259).Ground Floor |
| 134 | 10001350Fixing EWC Commode floor mount(P trap-180mm), UF soft close slim seat cover, hinges, accessories set with rack bolt 12mm dia stainless steel fixed to the floor head less socket caps/wall plugs and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification with DUAL FLUSH CISTERN and all fitting accessories complete. SIZE: 360x655x765 mm. Make: JAQUAR LYS-WHT-38851P180UFSM.Ground Floor |
| 135 | 50014165Supplying and fixing of urinal sensor concealed type flushing valve for urinal complete set with installation box with control cock(battery operated) Make: Jaquar SNR-STL-51087.Ground Floor |
| 136 | 50014167Supplying and fixing of SS double coat hook for bath and dressing room Make: Jaquar- ACN-1161N.Ground Floor |
| 137 | MIS-CVL-BOUNDARYWA |
| 138 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 139 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 140 | 50000008\\"Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. \\"Ground Floor |
| 141 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 142 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 143 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 144 | 50000023Providing and applying priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc. complete.(Exterior Primer, Brand :- Dulux Sealer E800(Product code 9061393) or Equivalent product of Asian Paints or Berger)Ground Floor |
| 145 | 50000488Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and PlinthGround Floor |
| 146 | 50000490Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Ground Floor |
| 147 | 50000742Painting two coats of Anti-fugal weather coat water proofing paint including scaffolding and cleaning the surface before application .including cost of all materials ,labour T& P etc complete.(Weather coat, Brand :- Dulux Weathershield Project(Product code IN45100081)(5 Years warranty) or Equivalent product of Asian Paints or Berger)Ground Floor |
| 148 | 50001780Supplying,fitting & fixing of GI 3ply barbed wire made out of 18gsm GI wire including cost of all labour,material,T & P etc. completed as per the direction of E.I.C. Make-TATAGround Floor |
| 149 | 50010372Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS)Ground Floor |
| 150 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 151 | 50010444Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM)Ground Floor |
| 152 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 153 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 154 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 155 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 156 | 50011526Supplying, fitting & fixing of 2.6mm dia galvanised concentina wire embeded 0.50mm thick sharp edged GI sheet to make coil of 26\\" dia and after stretched to 6mtr with have 50 nos spiral; change to 24\\" dia fixed with minimum 125 RBT (Reinforced barbed tape) per coil. The coil will sustain on 3nos of 2.6mm dia GI wire runner including cost of all labour, material, transportation and fixing charges, T & P etc. complete. Make:TATAGround Floor |
| 157 | MIS-CVL-DEMOLISION |
| 158 | 50000082\\"Dismentalling of brick/stone masonary in cement motar including stacking the useful materials for reuse and removing the debries with in 50 mtr lead. \\"Ground Floor |
| 159 | 50000084\\"Dismentaling of R.C.C.columns,beams,slab,staircase,landing and lintels including stacking the useful materials for reuse within 50 mtr.lead. \\"Ground Floor |
| 160 | 50000870Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris with in 50m lead.Ground Floor |
| 161 | 50010514Cutting, Spreading, and Cleaning work by Dozer D-50 -A 15, etc. complete as per the instruction & direction of the E.I.C .Ground Floor |
| 162 | MIS-CVL-DRAIN |
| 163 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 164 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 165 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 166 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 167 | 50000043Filling with excavated earth .Ground Floor |
| 168 | 50010360Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB)Ground Floor |
| 169 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 170 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 171 | MIS-CVL-DRIPIRIGAT |
| 172 | 50018165Providing, laying & jointing in position PVC pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction, PVC pipe 63mm-6 kg/cm2Ground Floor |
| 173 | 50018167Providing, laying & jointing in position PVC pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction, PVC pipe 50mm-6 kg/cm2Ground Floor |
| 174 | 50018169Providing, laying & jointing in position PVC pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction, PVC pipe 40mm-6 kg/cm2Ground Floor |
| 175 | 50018171Providing, laying & jointing in position PVC pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction, Earth work excavation and refilling 300x450mmGround Floor |
| 176 | 50018173Providing & fixing of PS- Ultra, Pop up spray head bodies, having features an encased plastic 'cage' to provide unmatched resistance to grit,with high efficiency ADJUSTABLE nozzle capable of covering 1.2M -5.2m at 1.0 - 2.1 Bars, pressur. Additionally Two-piece ratchet mechanism, Features is Precision controlled flush at pop-down clears debris from unit, Construction of time-proven UV_resitant plastic.Ground Floor |
| 177 | 50018175Providing & Fixing of SJ- 512, 1/2\\" Pop up Connecting Four Elbow Swing joint Assembly. The fittings shall be made of UV resistant thermo plastic.Ground Floor |
| 178 | 50018177Providing and fixing of PP service saddle of varying size.1/2'Ground Floor |
| 179 | 50018179Providing & fixing of Isolation Valve in mainline for bypass and flow diversion of approved quality 63 MMGround Floor |
| 180 | 50018181Providing and fixing of Isolation Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve of size 63mm.Ground Floor |
| 181 | 50018183Providing & fixing of a double acting 1\\" Air release valve, The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Including service saddle and riser assembly.Ground Floor |
| 182 | 50018185Providing & fixing of 12\\" Rectangular Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockoutGround Floor |
| 183 | 50018187Providing & fixing of 6\\"Round box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockoutGround Floor |
| 184 | 50018189Providing & fixing of Brass Quick coupling valve made up of solid brass with locking cover corrosion resistant and stainless steel spring. Including service saddle and riser assembly.Ground Floor |
| 185 | 50018191Providing & fixing of Brass Key threads into top of QCV to provide water access And Brass Swivel ElbowGround Floor |
| 186 | 50018193Providing & Fixing of Filter filtration with capacity matching pump design flow having an suitable inlet connections , to create a helical effect in the incoming water ,spinning particulate in suspension away from the filtering element and so minimizing cleanings frequency ,3/4\\" outlet for flushing at bottom of filter & maximum working presure of 10 Bars. with pressure gauge (20M3).Ground Floor |
| 187 | 50018195Providing & Fixing of VFD pumpset of having discharge of 3.56 lps@ 52 to 55 mtr head with NRV, control valve, control panel mounted on a common base skid with required size of pressure vessel etc complete.Ground Floor |
| 188 | 50018197Providing & Fixing of GI Suction ,Delivery & Header PipeGround Floor |
| 189 | 50018199Providing & fixing of Butterfly Valve in mainline for bypass and flow diversion of approved qualityGround Floor |
| 190 | 50018201Providing and fixing of Pressure Release ValveGround Floor |
| 191 | 50018203Supply of Direct burial 14 AWG x 1C cable Live WireGround Floor |
| 192 | 50018205PVC conduit Pipe complete 32 mmGround Floor |
| 193 | 50018207Supply of X-Core: RESIDENTIAL/LIGHT COMMERCIAL CONTROLLERS 230 VAC outdoor mount with 230/240 VAC internal transformer control system , Built in Solar Sync, Easy Retrive Memory QuickChekTM Seasonal Adjustment ,Sensor Programability (8Station)Ground Floor |
| 194 | 50018209Supply of 2\\" Solenoid globe Valves with fabric reinforced diaphram and rugged PVC construction ,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar with 24AC solenoid, with provision to attach Pressure RegulatorGround Floor |
| 195 | 50018211Supply and fixing of direct bury -on wire connector with strain relief , with waterproof silicon sealant.Ground Floor |
| 196 | 50018213Supply and fixing of SOLARSYNC COMPATIBLE WITH PRO-C, ICC AND I-CORE CONTROLLERS, COMES COMPLETE WITH SENSOR PLATFORM AND CONTROLLER INTERFACE, AUTOMATICALLY RESPONDS TO LOCAL WEATHER CHANGES .Ground Floor |
| 197 | MIS-CVL-ENTRYEXITG |
| 198 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 199 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 200 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 201 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 202 | 50010360Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB)Ground Floor |
| 203 | 50010372Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS)Ground Floor |
| 204 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 205 | 50010446Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS)Ground Floor |
| 206 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 207 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 208 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 209 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 210 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 211 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 212 | MIS-CVL-EXTERNALWA |
| 213 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 214 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 215 | 50000019\\"25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. \\"Ground Floor |
| 216 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 217 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 218 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 219 | 50000488Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and PlinthGround Floor |
| 220 | 50000490Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Ground Floor |
| 221 | 50000738Providing and laying plain cement concrete 1:3:6 (1 cement: 3 sand: 6 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 222 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 223 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 224 | 50010572Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500)Ground Floor |
| 225 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 226 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 227 | 50010608Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean).Ground Floor |
| 228 | 50010620Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY)Ground Floor |
| 229 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 230 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 231 | 50010668Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/GreenGround Floor |
| 232 | 50010680Providing and fixing of ISI marked 30 mm thick Flush door Shutters (Single leaf) finished with 1mm thick lamination both side total thickness of 32mm flush door Shutter with 4 Nos SS butt Hinges (125 mm x 85 mm x 5.5 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 1 No SS Aldrop (400mm X 300mm x 16mm dia rod), 1 No Floor type double door stopper, 2 Nos SS Handle of size 150mm, Teak wood Leaping around the edges, 1 No. Back Buffer with all materials,adhesives etc complete. (Excluding door closure, ornamental handle and Mortise Lock). [NSWI] Make:- BWP Flush door (Century Sainik 710 / Green marine gold 710), Laminate (Greenlam/ Centurylam,Marino),Hard ware fittings (Godrej).Ground Floor |
| 233 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 234 | 500108152.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete.Ground Floor |
| 235 | 50010827Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 900mm C/C, stainless steel square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification and the entrance newel post will be 100mm dia. of 750mm height with top bulb, buffing, polishing etc. with cost, conveyance, labour, T and P etc. required to complete in all respect. [NSWI] Stainless steel Brand:- JINDAL/NIPPON STEEL.Ground Floor |
| 236 | 50011579Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB)Ground Floor |
| 237 | 50011592Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC COLUMNS)Ground Floor |
| 238 | 50011616Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING)Ground Floor |
| 239 | 50011628Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR LINTEL BEAM).Ground Floor |
| 240 | 50011664Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR TIE BEAM).Ground Floor |
| 241 | 50011676Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC FLOOR BEAMS).Ground Floor |
| 242 | 50011926Providing & applying water proofing treatment on SITC of Sunken floor treatment Stage1:Cleaning of concrete surface to remove dust,oil ,grease including removal of laitance and cleaning with compressed air.Repairing surface irregularities,damaged concrete,if any ,with Sika Latest modified repair mortar including a coat of bonding agent. Stage2:supply and application of 1:3 cement-sand mortar ,mixed with sika top 77-the polymer modified high quality emulsion,as a coving at the corners of floor and the vertical surface in the sunken area,and between floor and walls in the remaining area. Stage3:Supply and application of Sika Top Seal 107-the cementitious ,flexible waterproof coating onto the prepared surface in a continuous film on the floor of the sunken area,taking the coating over the vertical surfaces on the floor and over the coving on to the wall (before tilling) to at least 300mm above the final finished floor level.The coating shall also be continued on to the inner surfaces of the pipe penetration holes .Two coats shall be applied. Chemical Base Part A:liquid polymer and additive Part B:portland cement with selected aggregate and additive,Density fresh slurry density~2.00kg/I at +270C ,Layer Thicknes 1.5mm -2.00 average,water Vapour Resistance 3g/m2/day.Mechanical/Physical properties 3 days~2N/mm2,28 days~20N/mm2.Compressive Strength Above values at +270C,tensile Strength~4.56N/mm2 after 14 days exposure(According to ASTM D 2370),Bond Strength 2.0N/mm2 at +270C (failure in substrate),Elongation at Break With sika@ Fab-1,8-10% (Make:- MYK or Sika or BASF)Ground Floor |
| 243 | 50012056System Aluminum Sliding Windows – Single Glazed (With MESH): Providing and fixing System Aluminum works for Sliding windows with sash 65x27mm, mesh sash 65x27mm, made of non-euro groove architectural aluminium profile. The extruded aluminums sections should be T6 tempered made from Grade 6063 alloy, approved shade of pure-polyster/ hybrid surface coating Anodized (50-60-micron powder coat), silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. All Slider windows will be center locking of aluminium/zamark. Integrated Anti-lift in slider panel, Frame width shall be 80 mmx45 for 3 track (2 Glazed panels and 1 Mesh panel track provision) with +/- 2mm maximum tolerance. Provision of mesh track must be inbuilt in the offered system. The drainage slots provided at the bottom part of the frame/sash on the outerside, single wheel nylon fixed rollers, nylon anti-rattlers, nylon wing angles & weather strip siliconased brush gasket will be provided. 6mm Clear Toughend Glass (Saint-Gobain / AIS) / Fibre-glass Mesh (Charcoal) infill fitted unto Sash/Frame using micro-wave treated siliconised EPDM gasket. * Wall Thickness - Aluminium: 1.5mm.The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. This cost includes labour, materials, wastage, transportation at site, fixing, fittings, etc. all complete. (Make :- FENESTA/ REKLAD)Ground Floor |
| 244 | 50014133Supply, fitting & fixing of AT S Control panel(25 HP) (page-239 ,item no.9.(iii) of SOR 2022)Ground Floor |
| 245 | 50014135Submersible/Centrifugal PumpSets without Control Panel(25 HP)(page-238 ,item no.3.(ii) of SOR 2022)Ground Floor |
| 246 | 50018063Providing and supplying Shock, Seismic (C1 & C2), Fatigue and Fire approved, ETA approved HIT-RE500V3 with HIT-V Threaded Rod to use in cracked/uncracked concrete, tested for service temperature of -40 deg. C to +80 deg. C. The product should be approved by ETA, ICC, CSTB, COLA, BZS. Anchoring with HIT-V with RE500V3 to be designed as per guidelines of TR 029. Drilling hole with double flute type drill bits/ hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery operated dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate embedment depth & number of anchors to be calculated as per PROFIS Anchor Software & the report to be submitted to the project manager, design engineer for approval. Scanning with PS250 Scanning Tool before drilling to be done to avoid hitting existing rebars. For zones with high seismicity, seismic designs are mandatory. For shear loads, base plate designed by SOFA, filling sets are mandatory. The rate mentioned includes cost of all labours, materials, conveyance, loading and unloading and T&P etc. HIT-RE 500 V3 with Anchor rod HIT-V- 5.8 M12X150Ground Floor |
| 247 | 50018065Supplying of all Labour,material and equipment for core drilling work of following size and specification as per the direction of En gineer-in-work. Diamond Core Drilling 152 dia and depth of 150 mm on slab.Ground Floor |
| 248 | 50018067Design,supplying ,fixing, installation and Testing and commissioning of WTP of 10m3 /hour incluidng of chemical dosing system, filter feed pump with starter ,Multi garde filter,Activated carbon filter with inter connecting pipe work etc all completer as per the direction of Engineer-in-charge.Ground Floor |
| 249 | 50018269Providing and fixing Chlorinated polyvinyl chloride (cpvc) pipes 100mm nominal outdoor dia pipesGround Floor |
| 250 | 5001827165mm nominal outdoor dia pipes MATERIALS Chlorinated polyvinyl-chloride (cpvc) pipe 65mm outdoor diaGround Floor |
| 251 | 50018275\\"Fixing Cast Iron Sluice Valve with double flanged ends for water works purposes conforming to IS 14846 - 2000 for the following rating and nominal diameters as per specification complete.100 mm diameter \\"Ground Floor |
| 252 | 50018277Fixing swing check type Reflux Valves (Non-return valves) with double flanged ends conforming to IS: 5312 (Part-I)- 2004 for water works purposes for the following rating and nominal diameters as per specification complete PH ANALYSIS OF RATE 2013 CL NO 2.6.2 (B) (ii) 150 mm diameterGround Floor |
| 253 | 50018279Fixing of Brass or Gun Metal Full Way Valve conforming to IS:781-1995 of the following nominal sizes with wheel as per specification complete. 100 mm diameterGround Floor |
| 254 | MIS-CVL-INSPECTION |
| 255 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 256 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 257 | 50000008\\"Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. \\"Ground Floor |
| 258 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 259 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 260 | 50000488Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and PlinthGround Floor |
| 261 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 262 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 263 | MIS-CVL-INTERIORWO |
| 264 | 50002480Providing and fixing of Hydraulic Door Closers Heavy Duty (C680 EM rated- 40 to 80 kg) (Product code no. 8156) of Godrej/Dorma/ Hettich or any other equivalent approved make/quality including all fittings etc. all complete.Ground Floor |
| 265 | 50010074Providing & Fixing of Workstation Chair. Model:Geeken- GA 502 C. [NEW NSWI]Ground Floor |
| 266 | 50010915Providing, fitting and fixing of Gypsum false ceiling with Aluminium anodised T section no. 3215 with 2feet center to center, L section no. 1705 up to 15 microns on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2 feet x 2 feet suspended from ceiling etc. complete including cost of 12.5mm thick Gypsum board, all labour and material etc. complete. Aluminium Sections make:- FINESTA/HINDALCO/JINDAL, Gypsum board Make:- India Gypsum (SAINT GOBAIN) / USG Boral .Ground Floor |
| 267 | 50018091MCM BRICK CLADDING :- Supply of MCM Modified Clay Material ‐ MCM K Series Bricks of PHOMI or VANJOIN make, sizes of 225x60mm, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation ‐ Class A— ASTM E84‐ 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.Ground Floor |
| 268 | 50018093HEXAGONAL SHAPE WALL PANEL :- Providing and Fixing of Knauf Optra Acoustical Wall Panel with Hexagonal shape square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 250x250mm (Nominal) or as per approved size and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives . The fibre glass substrate shall have a recycle content of 85%.Custom colors and finishes to match design requirements as per the directions of the EIC/Architect.Ground Floor |
| 269 | 50018095Supplying and fixing of painting & art work made out of acrylic painting on canvas with pvc framing , 5mm th glass on top & 6mm ply on back side of the painting as per design approved by eic .Ground Floor |
| 270 | 50018097Providing and Fixing of Following types of signage to be approved by the Architect/ EIC. Samples have to be approved by the concerned before execution. The rate is inclusive of the WPC board with fixing of the same along with Rates, Taxes, T&P all inclusive. 3D signage with graphic design on 4\\"/6\\" ACP base with 6mm raised letters (with out lighting)Ground Floor |
| 271 | 50018099Providing and Fixing of Following types of signage to be approved by the Architect/ EIC. Samples have to be approved by the concerned before execution. The rate is inclusive of the WPC board with fixing of the same along with Rates, Taxes, T&P all inclusive. 3D signage with graphic design on 4\\"/6\\" ACP base with 6mm raised letters (with lighting)Ground Floor |
| 272 | 50018101Providing and Fixing of Following types of signage to be approved by the Architect/ EIC. Samples have to be approved by the concerned before execution. The rate is inclusive of the WPC board with fixing of the same along with Rates, Taxes, T&P all inclusive. 3D signage with graphic design on 4\\"/6\\" ACP base with 3M vinyl sticker lettersGround Floor |
| 273 | 50018103Providing & supplying ss signage of different size as per the approved shade and design Including all cost of labour , T & P etc as per the detail design & specifications approved by EIC. 150 x 150 mmGround Floor |
| 274 | 50018105Providing & supplying ss signage of different size as per the approved shade and design Including all cost of labour , T & P etc as per the detail design & specifications approved by EIC. 150 x 450 mmGround Floor |
| 275 | 50018107Providing & supplying ss signage of different size as per the approved shade and design Including all cost of labour , T & P etc as per the detail design & specifications approved by EIC 150 x 300 mmGround Floor |
| 276 | 50018109Providing & fitting , fixing of Frosted Film For Glass Brand: 3M Monomeric Calendered, White With Matt Finish, Thickness:- With adhesive: 3.5-4.5 mils (0.09-0.11 mm) Glue: Permanent, Pressure Sensitive Acrylic Glue , With Polycoated Craftpaper based Liner as per the approved shade and design Including all cost of labour , taxes T & P etc as per the detail design & specifications approved by EIC . (Size and colour should be change as per the design and drawing and as per the direction by Architect/E-I-C)Ground Floor |
| 277 | 50018111Supplying and fixing walldecals/ wallpapers which are smooth / textured/ linear textured & 100% eco friendly , Non woven based . The film type is non woven based & vinyl coated . Overall length is 45.72 metre & overall width is 1220mm , 1524 mm , 610 mm . The product colour is white /off white and can be removed with water . Its shading coefficient is 0.93 & substrates are ABS, Glass, Paint, PMMA , Polycarbonate . Surface finish is matte finish . as per design approved by eic .Ground Floor |
| 278 | 50018113Providing & supplying of HOME DUSTBIN PADDLE 12L as per the detail design & specification including all cost of labour , material hardware ,etc excluding gst approved by eic.Ground Floor |
| 279 | 50018115Providing & supplying of TWIN DUSTBIN 10 LTR as per the detail design & specification including all cost of labour , material hardware ,etc excluding gst approved by eic.Ground Floor |
| 280 | 50018117Providing and supplying White Lacquered Glass Writing Board using the ANS Glass dry erase whiteboard, a sophisticated writing surface. Special finish provides a smooth writing surface that will not ghost or stain. Strong MDF base provides strength to glass and secures it. Glass enhances the looks of your premises and uplift the dullness of spaces.Ground Floor |
| 281 | 50018119Providing and supplying Nilkamal 60 L Green Plastic Garbage Waste Bin of environment friendly etc. complete as per the direction of Engineer-in-charge.Ground Floor |
| 282 | 50018121Providing & supplying and planting different type of indoor plants of height not less than 450mm and etc including of plastic pot with tray etc as per the direction of Engineer-in-charge. The cost inclusive of all lebour, material, good earth , sludge transportation , loading and unloading and lifting etc all completeGround Floor |
| 283 | 50018123OFFICER CABIN TABLE :- (Make-Isit) Providing & supplying of Office table of size 750 x1500x750 With 25mm thick Top made up of HDHMR board (Action Tessa) with 1 mm thick Merino Laminate or equivalent on the exposed surface and 0.92 mm inner laminate on the internal face & all sides edgebanded with Rehau PVC edge banding. One pc pedestal with one drawer and shutter.Ground Floor |
| 284 | 50018125PANTRY UNIT BASE CABINET :- (Make Isit) Providing & supplying of Full Modular Kitchen with all fittings. Carcass is made up of HDHMR board with inner side laminated with inner 0.92lamunate and external finished with 1mm Merino Laminate and edges finished with matching edge banding of 2mm thickness. 1. Base unit carcass will be finished with twist cream laminate internally and hinges and channels of Olive/Hettich/Azalea/Hafele brand. Baskets and tandems of Hettich brand. Carcass is fitted with 100mm PVC leg of Rehau brand and PVC skirting is fixed on it. 2. Wall units carcass will be finished with Twist Cream laminate internally and shutters finished with 1mm Merino Laminate on external surface and twist cream on the inner side. Hinges and fittings to be used wil be of Hettich/Azalea or equivalent brand.Ground Floor |
| 285 | 50018127PANTRY UNIT WALL CABINET :- (Make-Isit)Providing & supplying of Full Modular Kitchen with all fittings. Carcass is made up of HDHMR board with inner side laminated with inner 0.92lamunate and external finished with 1mm Merino Laminate and edges finished with matching edge banding of 2mm thickness. 1. Base unit carcass will be finished with twist cream laminate internally and hinges and channels of Olive/Hettich/Azalea/Hafele brand. Baskets and tandems of Hettich brand. Carcass is fitted with 100mm PVC leg of Rehau brand and PVC skirting is fixed on it. 2. Wall units carcass will be finished with Twist Cream laminate internally and shutters finished with 1mm Merino Laminate on external surface and twist cream on the inner side. Hinges and fittings to be used wil be of Olive/Hettich/Azalea/Hafele or equivalent brand.Ground Floor |
| 286 | 50018129OFFICE TABLE :- (Make-Isit)Providing & supplying of Office table of size 750 x1800x750 With 25mm thick Top made up of HDHMR board (Action Tessa) with 1 mm thick Merino Laminate or equivalent on the exposed surface and 0.92 mm inner laminate on the internal face & all sides edgebanded with Rehau PVC edge banding. One pc pedestal with one drawer and shutter.Ground Floor |
| 287 | 50018131WORKSTATION :- (Make-Isit)PERFORM SHARING WORKSTATION , SIZE: 1050W X 600D X 750HT TABLE TOP WITH 350MM HT SCREEN , Specifications: Table top: Made of 25mm thick prelaminated particle board of approved shade. All the edges of workstation surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Main Screen: 30mm thick Fabric magnetic And glass marker screen on Table top Under Structure Support: Table top is supported on MS Powder coated Square perform Legs which is constructed by 50Sq-16g ERW tube acts as vertical member & supporting MS cross beam, which is made of 40 x 20 x 1.6 gauge rectangular tube and connected to legs with aluminium die cast wing connectors. Modesty Panel: MS square perforated metal modesty panels of 450mm ht are provide at passage. Intermidiate Screen - 8mm thick coloured glass screen on powder coated studs.Ground Floor |
| 288 | 50018133PEDESTAL (Height-750mm, Depth 420mm) :- (Make-Isit)Providing & suppying PEDESTAL with 3 drawers made out of 18 mm thick (Action Tessa) HDHMR Board , 6mm thick HDHMR Board at back & laminated with 1. 0 mm thick Merino SF laminate on out side & 0.92 mm thick laminate at in side , the exposed wooden surface Edgebanded with Rehau PVC Edgeband 2mm on visible sides and 0.8mm on hidden side with Autoclose hinges, Channels and handles of Hettich/Azalea/Olive/Polo and equivalent.Ground Floor |
| 289 | 50018135WORKSTATION :- (Make-Isit) Providing & supplying of L Shaped WORKSTATION of size 1500 x 1500 With 25mm thick Top made up of HDHMR board (Action Tessa) with 1 mm thick Merino Laminate or equivalent on the exposed surface and 0.92 mm inner laminate on the internal face & all sides edgebanded with Rehau PVC edge banding. With screen 450x1500x30 aluminum frame with matching Laminate or Fabric/glass.Ground Floor |
| 290 | 50018137CONFERENCE TABLE (Make-Isit)(Height-750mm, Width- 3300 & Depth 1200mm) :- Providing & suppying CONFERENCE TABLE with 40mm thick top with CORIAN SOLID SURFAC TOP of Rehau/Hanex brand finish and Under Structure made out of 18 mm thick Action Tessa HDHMR Board and laminated with 1. 0 mm thick Merino SF laminate on outside & 0.92 mm thick laminate at inside, the exposed wooden surface Edgebanded with Rehau PVC Edgeband 2mm on visible sides and 0.8mm on hidden side.Ground Floor |
| 291 | 50018139CLASS ROOM DESK(Make-Isit) * Classmate Low Back Mesh Chair * With Arms * Black Powdercoated 4 Legs * Writing Desk * Fabric Upholstered Cushion Seat & BackGround Floor |
| 292 | 50018141CONFERENCE ROOM CHAIR :- FORTUNE MB ML ADJ ARMS(Make-Isit) * Amaze Medium Back Mesh Chair * AN 70 Mesh * Self Calibrating Multilock Mechanism * Adjustable Lumbar Support * One Way Adjustable Arms (Height) * Nylon Base * Fabric Upholstered Cushion SeatGround Floor |
| 293 | 50018143CONFERENCE ROOM HEAD CHAIR :- SLIDER HBSSN '3D' ADJ ARMS(Make-Isit) *FP Optima High Back Mesh Chair *Optima Mesh Standard (black) * With Headrest * Multilock With Seat Sliding Mechanism * Three Way Adjustable Arms (Height & Swivel) * Chrome Magna Base * Fabric Upholstered Cushion SeatGround Floor |
| 294 | 50018145RECEPTION CHAIR :- COSMO VA(Make-Isit) Sledge Base PC FXD ARMS * Contact Project Low Mesh Back Visitor Chair * AN 70 Mesh * Powdercoated Sledge Base * Fixed Arms * Fabric Upholstered Cushion SeaGround Floor |
| 295 | 50018147RECEPTION SOFA(Make-Isit) :- MORABO Leatherette Three (3) Seater With Chromeplated Legs & Frame (Size : 1900 (W) x 710 (D)x 750 (H)), Upholstery Options: Available in premium Synthetic Leather Leatherette or high durability Fabric options. Frame Material: Constructed from a robust Engineered Wood Wood internal frame structure. Cushion Density: High-resilience foam padding featuring a density rating between 40 and 50 to optimize long-term seating comfort and prevent sagging. Design Aesthetic: Part of the \\"Converse\\" collection, characterized by a contemporary aesthetic geared toward professional breakout spaces and loungesGround Floor |
| 296 | 50018149RECEPTION SOFA :- MORABO(Make-Isit) Leatherette 1 single Seater with Chromeplated Legs & Frame (Size : 875 (W) x 710 (D)x 750 (H)). Upholstery Options: Available in premium Synthetic Leather Leatherette or highdurability Fabric options. Frame Material: Constructed from a robust Engineered Wood Wood internal frame structure. Cushion Density: High-resilience foam padding featuring a density rating between 40 and 50 to optimize long-term seating comfort and prevent sagging. Design Aesthetic: Part of the \\"Converse\\" collection, characterized by a contemporary aesthetic geared toward professional breakout spaces and loungesGround Floor |
| 297 | 50018151RECEPTION CENTRE TABLE WOOD LEGS(Make-Isit) (Size:-1050WX525DX 550H) With PLB Top Understructure: High-quality solid wooden legs or stylized wooden framing designed to provide stable floor clearance and a warm aesthetic Tabletop Materials: Durable pre-laminated particle board or high-pressure laminate finishesGround Floor |
| 298 | 50018153CABIN ROOM CHAIR :- FORTUNE HB ML ADJ ARMS(Make-Isit) * Amaze High Back Mesh Chair * AN 70 Mesh * Self Calibrating Multilock Mechanism * Adjustable Lumbar Support * One Way Adjustable Arms (Height) * Nylon Base * Fabric Upholstered Cushion SeatGround Floor |
| 299 | 50018155CAFETERIA TABLE (Make-Isit):- ISO CAFÉ TABL ( 4 SEATER ) ISO TABLE TOP WITH POWDER COATED UNDER STRUCTURE (WHITE/ MAPLE) SIZE - 1200 X 800 X 750Ground Floor |
| 300 | 50018157CAFETERIA CHAIR :- Trio CAFÉ(Make-Isit) CHAIR Polypropylene cafeteria stackable chair.Ground Floor |
| 301 | 50018159LOBBY SOFA :- MAXIM ( Make-Isit)Leatherette 3 SEATER ) SIZE : 2020 (W) x 975 (D) x 820 (H) Frame Material: Heavily reinforced frame designed for rigorous commercial workspace environments Upholstery: Synthetic Leather / Leatherette option provides an easily sanitizable surface, wrapping the seat, backrest, and integrated armrests Cushioning: High-density foam padding optimized to maintain structural shape and provide firm lower lumbar and thigh support over extended useGround Floor |
| 302 | 50018161LOBBY SOFA :- MAXIM (Make-Isit) Leatherette SINGLE SEATER ) SIZE : 950 (W) x 975 (D) x 820 (H) Frame Material: Heavily reinforced frame designed for rigorous commercial workspace environments Upholstery: Synthetic Leather / Leatherette option provides an easily sanitizable surface, wrapping the seat, backrest, and integrated armrests Cushioning: High-density foam padding optimized to maintain structural shape and provide firm lower lumbar and thigh support over extended useGround Floor |
| 303 | 50018162LOBBY SOFA :- MAXIM (Make-Isit) Leatherette SINGLE SEATER ) SIZE : 950 (W) x 975 (D) x 820 (H) Frame Material: Heavily reinforced frame designed for rigorous commercial workspace environments Upholstery: Synthetic Leather / Leatherette option provides an easily sanitizable surface, wrapping the seat, backrest, and integrated armrests Cushioning: High-density foam padding optimized to maintain structural shape and provide firm lower lumbar and thigh support over extended useGround Floor |
| 304 | 50018163CENTRE TABLE :- MAJESTIC CENTER TABLE METAL LEGS WITH Hydro-Shield TOP SIZE - 1050Wx 525Dx 550HT , Legs / Frame: Metal legs with durable powder coating finishDesign Style: Refined industrial look combining modern utility with bold characterGround Floor |
| 305 | 50018217METAL BAFFLE CEILING :- Providing & fixing horizontal level suspended ceiling comprising of Knauf Vertical Linear Baffle Ceiling made out of Aluminum Extrusion in Aluminum alloy grade 6063 T5. The baffle blade shall be in size of 100x25x3600mm in powder coated to Woodgrain/Plain finish (Red Oak, Cherry, Black / White). The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidthickity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E <1 using Excite/BYK Gardner instrument and gloss level 25±5% at 60˚ as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U-profile of 20 x 30 x 3700mm (Thk-1.5mm) having slots in module of 25mm to keep baffles at an on-center spacing in multiples of 25mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps.Ground Floor |
| 306 | 50018219GRID CEILING FOR PANTRY & KITCHEN :- Supply and Installation of Anutone 8 mm thick magnesium oxide square edge magnesia core ceiling tile of size 595 x 595 mm having density 1000 Kgs/ m3, weight 8 kg/m2 which is suspended by using 0.3 mm thick and 24 mm wide precoated metal T 24 grid system. The technical parameters are as follows :Core - Magnesia, Fire – Class 1 & P, AnutonAcoustics – STC 44 - 54 , climate - 50 , RH - 95, Termite resistance ,Green (RC %) – 30, Hygiene (VoC, Clean room) – Low, Class 3 , Thermal -0.12 W/mK. The T 24 Grid system of 600 x 600 mm module shall include wall angle (WA 24 W 30) with unequal flanges of size 14 & 20 mm wide, length 3000 mm, 0.43 mm thick fixed along the perimeter of wall with the help of nylon sleeves and suitable fasteners at 300 mm centers. Then suspend the Main T 24(MT 24 W 36) having flange width 24 mm, height 32 mm and length 3600 mm from the soffit with help of soffit cleat and wire rod along with leveling spring clip at 1200 mm c/c. Cross 24(CT 24 W 12) with flange width 24 mm, height 32 mm and length 1200 mm is then interlocked into the precut slots in the Main T 24 at 600 mm centers in the direction perpendicular to the Main T 24. Finally Cross T 24 (CT 24 W 06) having flange width 24 mm, height 32 mm and length 600 mm are then interlocked into the precut slots in the 1200 mm Cross T 24 at 1200 mm centers and in direction parallel to the Main T 24. Magnesium oxide vinyl square edge of size 595 x 595 x 8 mm thick shall be placed into the grid size of 600 x 600 mm. Test certificate will be submitted after procurement of materials.Ground Floor |
| 307 | 50018221ACCOUSTIC GRID CEILING:-Providing & Fixing of Knauf Fibre Glass Acoustical Suspended Ceiling System with 600X600X15mm thick Optra Microlook 90 Edge Tiles with Knauf Silhouette 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, , Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 20/25mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%. The rate shall be including all cost of materials , labour, overheads T & P etc., complete. as per the detail design and specification approved by Engineer -in-charge /Architect .Ground Floor |
| 308 | 50018223OPEN CELL ALUMINIUM FALSE CEILING :- Providing & Fixing horizontal level NewAge make Open cell Aluminium false ceiling system and shade, comprising of main and secondary blades of width 10 mm and height 40 mm made of 0.50mm thick Aluminium coil coated sheet grade 3003/3105, cross connected to form 100x100mm square cells laid on the 15 T grid system & accessories as per manufacturer's specifications and approved by engineer in charge and shall have sufficient loaded carrying capacity including any additional support members wherever required for light fixtures, AC diffusers, etc.Ground Floor |
| 309 | 50018227SOUNDSCAPES BLADE :- Providing and Fixing Knauf SoundScapes Blade - Acoustical blade which are 40 mm thick, flat glass fiber panels with Humidity Resistance RH 90%, with factory fitted embedded metal insert with ¼\\" – 20 threading for fixing cable adjuster for hanging application. Soundscapes blades shall have sizes of 200x1600mm, with both side laminated scrim finished with uniform water-based paint on all surface (including edges). Acoustical performance of 0.65 NRC (for 200mm high x 40mm thick baffles with 200mm on centre distance and overall depth of construction 1000mm) as per ASTM C-423 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) in standard White color with Light reflectance 87% or in the color specified by the Architect (Shell / Tangerine / Cranberry / Moss / Kiwi / Reef / Lagoon), Fire Performance Class B2 – s1, d0 as per EN 13501-1 .The SoundScapes blade shall be made of Glass fibre panel with density of 110-120 Kg/ m3. SUSPENSION: The panel shall be hung using deck hanging kit comprising of griper structure anchor & cap of dia 20mm, spring loaded bottom end cable adjuster of dia. 9mm and 2.4m long aircraft cable of 1/16\\" dia.Ground Floor |
| 310 | 50018229PANELLING THE WALL with laminate 20 MM THGround Floor |
| 311 | 50018231Providing and Fixing of Knauf Optra Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%. ( Acoustic wall for Conference hall)Ground Floor |
| 312 | 50018233MCM CLADDING :- \\"Providing and Fixing of MCM Modified Clay Material - MCM OASIS SERIES 1200 x 600 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139)manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.\\"Ground Floor |
| 313 | 50018235\\"Providing and Fixing of MCM Modified Clay Material - MCM TRAVENTINE STONE 1200 x 600 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.\\"Ground Floor |
| 314 | 50018237\\"MCM ITTIMI CLAY :- Supply and fixing of MCM Modified Clay Material - Ittimi 1800mm x 500mm, 1200mm x 600mm & 1350mm x 600mm of PHOMI make, as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer /Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer incharge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.\\"Ground Floor |
| 315 | 50018239FLUTED PANELS :- Fluted panels are characterized by their vertically grooved or ribbed surface. They can be made from various materials such as wood, WPC. Panel Size: Customizable, Flute Width: Typically ranges from 10mm to 50mm , Flute Depth: Typically ranges from 5mm to 20mm , Spacing Between Flutes: Varies based on design, commonly 5mm to 20mm , Finish Options - Natural Wood Finish: Varnished, stained, or lacquered / Painted: Matte, satin, or gloss finish in any color / Laminate: High-pressure laminate in various patterns and textures. Installation - Mounting: Directly on walls using adhesives or mechanical fasteners , Low VOC emissions . Patterns: Custom flute patterns and spacing available upon request , Colors: Custom colors and finishes to match design requirements as per the directions of the EIC/Architect.Ground Floor |
| 316 | 50018241DOUBLE SKINED SOLID PARTITION FINSHED WITH LAMINATE:- Providing , fitting and fixing up partition walling aluminium anodized section no 9210 and 9207 as single groove and double respectively as horizontal and vertical member and section 4660 as tapered clip and joining angle no 1855 etc. including 12 mm th bwp ply , 1mm th suede/ texture laminate on it. as per the design and specification with necessary teak wood plain / moulded beading including the cost of all materials , labour , nails, screw adhesives, overhead T & P etc. complete. The exposed frame work shall be finished with mat finish automotive paint or polish with mellamine as per the directions of the EIC/Architect. Data for 6'-10\\"x7'-6\\" = 51.22 sft or 4.76 sq m = 24.39 KGGround Floor |
| 317 | 50018243FULL HEIGHT DOUBLE SKINNED PARTITION glazed ( 8'-0\\"X8'-0\\")Ground Floor |
| 318 | 50018245PARTIAL GLAZED FLUSH DOOR BOTH SIDE LAMINATE Ref:OPWD AR-2006 page-132 Sl. No.3Ground Floor |
| 319 | 50018247FIXED FURNITURE LOW HEIGHT STORAGE (3'X1'-6\\" X2'-6)Ground Floor |
| 320 | 50018249FULL HEIGHT STORAGE (3'X1'-6\\" X7') WITH GLASS SHUTTERGround Floor |
| 321 | 50018253console TABLE ( 1200 X375 ) with Laminate & on top corionGround Floor |
| 322 | 50018255Toilet mirrorGround Floor |
| 323 | 50018257Self (3'-6\\"X2X2'-0\\") BASIN COUNTERGround Floor |
| 324 | 50018259Reception back drop 1.2 X1.35 MGround Floor |
| 325 | 50018261RECEPTION TABLE SIZE 15'X2'x3'-6\\"'-htGround Floor |
| 326 | 50018263ROLLERS BLIND (Translucent )Ground Floor |
| 327 | 50018265BLACKOUT ROLLER BLIND :Ground Floor |
| 328 | MIS-CVL-LANDSCAPEW |
| 329 | 50000044Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ).Ground Floor |
| 330 | 50001242\\"Earth work in ordinary soil within 50m. initial lead and 1.5m. initial lift including rough dressing and breaking clods to maximum 5cm. to 7cm. and laying and layers not exceeding 0.3m. in depth. \\"Ground Floor |
| 331 | 50002295Planting of Nerium Olender 3' ht. ornamental plants, well established healthy disease free in poly bag/ big container Including transportation and delivery at sites.Ground Floor |
| 332 | 50005655Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts Unit = Sqm (CPWD 2.12,P-217)[N.S.W.I]Ground Floor |
| 333 | 50005657Supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment) (CPWD 2.2,P-213)[N.S.W.I]Ground Floor |
| 334 | 50005659Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm (CPWD 2.4.3,P-214)[N.S.W.I]Ground Floor |
| 335 | 50005661Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).(CPWD 2.8,P-216)[N.S.W.I]Ground Floor |
| 336 | 50005663Providing & laying Selection no. 1 grass turf(Bermuda) with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same and maintenance for 30 days or more till the grass establish properly, as per direction of the officer in charge (CPWD 2.34,P-235)[N.S.W.I]Ground Floor |
| 337 | 50005665Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge. (CPWD 2.33,P-234) [N.S.W.I]Ground Floor |
| 338 | 50005667Planting of Murraya exotica 2'0'' ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites. This cost is including hoeing soil of size 2'dia and 2' depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant 8.46,p-372= Rs.15.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54 ,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 154.49.[N.S.W.I]Ground Floor |
| 339 | 50005669Planting of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara, Mohan, Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) 45cm ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites.This cost is including hoeing soil of size 2'dia and 2' depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant9.40,p-381= Rs.40.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25 ,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 179.49Ground Floor |
| 340 | 50005671Planting of Malpighia coccigera 2'1/2' ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites.This cost is including hoeing soil of size 2'dia and 2' depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant 8.45,p-372= Rs.50.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54 ,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 189.49[N.S.W.I]Ground Floor |
| 341 | 50005673Planting of Tecoma grandiflora 2'1/2\\" ht. ornamental plants,well established healthy disease free in poly bag / big container including transportation and delivery at sites.This cost is including hoeing soil of size 2'dia and 2' depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge .Plant 9.13,p-383= Rs.40.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54 ,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 179.49Ground Floor |
| 342 | 50005681Planting of Hena 2'0' ht. well grown healthy plant species as per specified height all saplings are healthy grown well canopy,disease free etc. including transportation and delivery at sites.This cost is including hoeing soil of size 2'dia and 2' depth, mixing spreading soil and manure in 2:1 ratio, watering, maintenance for 30 days or more till the plant establish properly, as per direction of the officer in charge . Plant 8.50,p-373= Rs.40.00, hole 2.14.3,p-218= Rs. 30.02, Antitermite 2.54,p-246= Rs.46.34x.3= Rs.13.9, Cattle manure 0.1 cum 2.25,p-224= Rs.374.12x.1 =Rs.37.41, fencing .3 Sqm Rs.193.58x.3=58.16, Total Rs. 179.49(Say Rs.180.00)[N.S.W.I]Ground Floor |
| 343 | 50006326Maintenance Per Month including fertilizer pesticide, man power,grass cutting, straining, Seasonal flower all etc.[N.S.W.I]Ground Floor |
| 344 | 50018073Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. Neem of height 3m - 4m (3 to 4 years old) well developed with thick stemGround Floor |
| 345 | 50018075Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting Karanja of height 4m -5m (3 to 4 years old) well developed with thick stemGround Floor |
| 346 | 50018077Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. Akashmalli of height 3m - 4m (3 to 4 years old) well developed with thick stemGround Floor |
| 347 | 50018079Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting Amla of height 3m - 4m (3 to 4 years old) well developed with thick stemGround Floor |
| 348 | 50018081Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting Mango of height 4m -5m (3 to 4 years old) well developed with thick stemGround Floor |
| 349 | 50018083Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting Kochila of height 4m -5m (2 to 3 years old) well developed with thick stemGround Floor |
| 350 | 50018085Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting Champa (white,red, pink) of height 3m-4m (2 to 3 years old) well developed with thick stemGround Floor |
| 351 | 50018087Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. Baul of height 4m -5m (3 to 4 years old) well developed with thick stemGround Floor |
| 352 | 50018089Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. Arjun of height 3m-4m (2 to 3 years old) well developed with thick stemGround Floor |
| 353 | 50018215Supplying and planting below mentioned best quality container- grown healthy trees of species as specified and with an average height and as age as mentioned as per Schedule of Rates,Analysis of Rates and Specifications (Horticulture & Landscaping) 2020 and direction of Engineer in Charge. All trees to be approved by Engineer-in-Charge before planting. Ashoka of height 4m -5m (3 to 4 years old) well developed with thick stemGround Floor |
| 354 | 50018285Digging Holes 60 cm dia, and 60 cm deepGround Floor |
| 355 | 50018287Digging Holes 45 cm dia, and 45 cm deepGround Floor |
| 356 | 50018289Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.Ground Floor |
| 357 | 50018291Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Hedge PlantGround Floor |
| 358 | 50018293Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)Ground Floor |
| 359 | MIS-CVL-MAINBUILDI |
| 360 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 361 | 50000002Earthwork in disintintigrated rock not requiring blastingto be removed by pickaxe crowbars and depositing materials within 50m. initial lead and 1.5m. initial lift including rough dressing as per direction and specification of the deptt. includig stacking useful materials separately as ordered in foundation.Ground Floor |
| 362 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 363 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 364 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 365 | First Floor |
| 366 | Second Floor |
| 367 | Third Floor |
| 368 | Forth Floor |
| 369 | Fifth Floor |
| 370 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 371 | First Floor |
| 372 | Second Floor |
| 373 | Third Floor |
| 374 | Forth Floor |
| 375 | Fifth Floor |
| 376 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 377 | First Floor |
| 378 | Second Floor |
| 379 | Third Floor |
| 380 | Forth Floor |
| 381 | Fifth Floor |
| 382 | 50000033\\"40 mm thick grading contrete(1:2:4) over roof with 12mm size and down grade chips,after chiseleing scraping the roof surface including cost of all materials forgrouting etc. complete\\"Fourth Floor |
| 383 | 50000044Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ).First Floor |
| 384 | Second Floor |
| 385 | Third Floor |
| 386 | Forth Floor |
| 387 | Fifth Floor |
| 388 | 50000490Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Third Floor |
| 389 | 50000495Fly Ash brick masonry in cement mortar 1:4 (1 cement:4sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75 kg per sq. cm with dimensional tolerance +/-2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Third Floor |
| 390 | 50001305Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure.Ground Floor |
| 391 | First Floor |
| 392 | Second Floor |
| 393 | Forth Floor |
| 394 | Fifth Floor |
| 395 | 50001311Fly Ash brick masonary in cement mortar 1:4:(1 cement:6 sand) using Fly Ash bricks of 23cm x 11cm x 8cm having crushing strength not less than 75kg./Cm2 per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Superstructure.Ground Floor |
| 396 | First Floor |
| 397 | Second Floor |
| 398 | Forth Floor |
| 399 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 400 | First Floor |
| 401 | Second Floor |
| 402 | Third Floor |
| 403 | Forth Floor |
| 404 | Fifth Floor |
| 405 | 50010572Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500)Ground Floor |
| 406 | First Floor |
| 407 | Second Floor |
| 408 | Third Floor |
| 409 | Forth Floor |
| 410 | Fifth Floor |
| 411 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 412 | First Floor |
| 413 | Second Floor |
| 414 | Third Floor |
| 415 | Forth Floor |
| 416 | Fifth Floor |
| 417 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 418 | First Floor |
| 419 | Second Floor |
| 420 | Third Floor |
| 421 | Forth Floor |
| 422 | Fifth Floor |
| 423 | 50010608Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean).Ground Floor |
| 424 | First Floor |
| 425 | Second Floor |
| 426 | Third Floor |
| 427 | Forth Floor |
| 428 | Fifth Floor |
| 429 | 50010620Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY)Ground Floor |
| 430 | First Floor |
| 431 | Second Floor |
| 432 | Third Floor |
| 433 | Forth Floor |
| 434 | Fifth Floor |
| 435 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 436 | First Floor |
| 437 | Second Floor |
| 438 | Third Floor |
| 439 | Forth Floor |
| 440 | Fifth Floor |
| 441 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 442 | First Floor |
| 443 | Second Floor |
| 444 | Third Floor |
| 445 | Forth Floor |
| 446 | Fifth Floor |
| 447 | 50010668Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/GreenGround Floor |
| 448 | First Floor |
| 449 | Second Floor |
| 450 | Third Floor |
| 451 | Forth Floor |
| 452 | 50010704Providing and Fixing of Single leaf solid WPC door shutter of 30 mm thick compacted with wood grain finished with 2 Nos SS Handles (150 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 4 Nos. SS Butt Hinges (125mm x 8.5mm x 5.5mm ) with all necessary fittings Complete with approved colour . [NSWI]Make:- WPC Door(Century/Green), Hard ware fittings (Godrej).Ground Floor |
| 453 | First Floor |
| 454 | Second Floor |
| 455 | Third Floor |
| 456 | Forth Floor |
| 457 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 458 | First Floor |
| 459 | Second Floor |
| 460 | Third Floor |
| 461 | Forth Floor |
| 462 | Fifth Floor |
| 463 | 50010827Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 900mm C/C, stainless steel square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification and the entrance newel post will be 100mm dia. of 750mm height with top bulb, buffing, polishing etc. with cost, conveyance, labour, T and P etc. required to complete in all respect. [NSWI] Stainless steel Brand:- JINDAL/NIPPON STEEL.Ground Floor |
| 464 | First Floor |
| 465 | Second Floor |
| 466 | Third Floor |
| 467 | Forth Floor |
| 468 | 50010975Providing and finishing the wall surface with texture paint finish with approved materials of texture powder used @ 0.30Kg/Sqft of approved shade including scaffolding, cost of all materials and labour. [NSWI] Texture Paint brand:-ASIAN (Duracast Dholpurtex)/BURGER (Ruff-n-Tuff Decora Finish - Dholpur Cols)/DULUX (ultrafine honeycomb).Ground Floor |
| 469 | First Floor |
| 470 | Second Floor |
| 471 | Third Floor |
| 472 | Forth Floor |
| 473 | Fifth Floor |
| 474 | 50011101Providing and laying in position 200mm thick Tremix/VDF flooring P.C.C. M-30 grade concrete using 20mmnominal size HBG down graded chips for plain cement concrete work using cement content 400kg/cum as per approved design mix having continious agitated mixer,mis design of specified grade for reinforced cement concrete work and for VDF floorng using screed board vibrator,placing of filtermat(nylon cloth to act as very fine filter),top mat (large single PVC sheet),Vaccume process using vaccume pump about 0.08MPA which ruduces water content about 15-20% ,power trawelling,brooming,T&P Charges including power,loading,unloading and hire charges,making grooves of 6mm wide and 25mm deep @ 1.5m C/C both ways ,filling the joints with sealing compound of approved quantity\\"Grade-A\\"(Ref:DSR-SH 16.46.1) with cost of material ,labour,conveyance,royalty etc. complete basing on IS 256:2000 minimum slump is 25mm to 75mm and minimum thiockness is 125mm .Ground Floor |
| 475 | 50011103Painting runway/taxi/track/apron marking with adequate nos of coats (minimum 2coats) to give uniform finish with road marking paint Based on solvent based acrylic resin has UV resistant colours of superior make (water based) i/c cleaning the surface of all dirt scales, oil, grease and other foreign material etc. and lining out complete. For new road work. Ref: DSR-16.47.1.Make(Asian paints:APCOTRAK, Berger:ROAD MARKING PAINT, Dulux :PROFESSIONAL WEATHER SHIELD ANTI-CARB)[NEW-NSWI]Ground Floor |
| 476 | 50011105Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using Hot applied thermoplastic compound conforming to ASTM: D36 or BS 3262 (Part-I) by fully/ semi automatic Thermoplastic paint applicator machine fitted with profile shoe, Reflectorising glass beads conforming to BS:6088 and BS 3262 (Part-1) dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour,T&P,cleaning the road surface of all dirt,seals,oil,grease and foreign material etc.complete and accordance with applicable specifications Ref: DSR-16.62.[NEW-NSWI]Ground Floor |
| 477 | 50011486Supplying, Fitting & Fixing of Anti-Skid Vitrified Tile (PREMIUM QUALITY) on floors of size 600mm x 600mm x 9 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free. Make: (JOHNSON ENDURA/ SOMANY TECHSTONE/ KAJARIA (STONE)) Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout) (NSWI SPECIAL)Ground Floor |
| 478 | First Floor |
| 479 | Second Floor |
| 480 | Third Floor |
| 481 | Forth Floor |
| 482 | 50011516Providing, Fixing & Fitting Ceramic glazed tiles (PREMIUM QUALITY) on wall of size 300mmx600mm of approved shade on 12mm thick cement mortar of mix (1:3) and grouted with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect. (JOHNSON/SOMANY/KAJARIA) (NSWI SPECIAL)Ground Floor |
| 483 | First Floor |
| 484 | Second Floor |
| 485 | Third Floor |
| 486 | Forth Floor |
| 487 | 50011579Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB)Ground Floor |
| 488 | First Floor |
| 489 | Second Floor |
| 490 | Forth Floor |
| 491 | Fifth Floor |
| 492 | 50011628Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR LINTEL BEAM).Ground Floor |
| 493 | First Floor |
| 494 | Second Floor |
| 495 | Forth Floor |
| 496 | Fifth Floor |
| 497 | 50011652\\"Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC STAIRCASE).Ground Floor |
| 498 | First Floor |
| 499 | Second Floor |
| 500 | Forth Floor |
| 501 | 50011676Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC FLOOR BEAMS).Ground Floor |
| 502 | First Floor |
| 503 | Second Floor |
| 504 | Forth Floor |
| 505 | Fifth Floor |
| 506 | 50011700Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS).Ground Floor |
| 507 | First Floor |
| 508 | Second Floor |
| 509 | Forth Floor |
| 510 | Fifth Floor |
| 511 | 50011984Providing granite stone (plane leather finish) of 20mm thick above 0.4sqm on flooring of approved quality and size in staircase floors, kitchen platform including edge moulding and groove cutting etc in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the marble tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties, etc. all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically complete in all respect as per specification.Ground Floor |
| 512 | First Floor |
| 513 | Second Floor |
| 514 | Third Floor |
| 515 | Forth Floor |
| 516 | Fifth Floor |
| 517 | 50012056System Aluminum Sliding Windows – Single Glazed (With MESH): Providing and fixing System Aluminum works for Sliding windows with sash 65x27mm, mesh sash 65x27mm, made of non-euro groove architectural aluminium profile. The extruded aluminums sections should be T6 tempered made from Grade 6063 alloy, approved shade of pure-polyster/ hybrid surface coating Anodized (50-60-micron powder coat), silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. All Slider windows will be center locking of aluminium/zamark. Integrated Anti-lift in slider panel, Frame width shall be 80 mmx45 for 3 track (2 Glazed panels and 1 Mesh panel track provision) with +/- 2mm maximum tolerance. Provision of mesh track must be inbuilt in the offered system. The drainage slots provided at the bottom part of the frame/sash on the outerside, single wheel nylon fixed rollers, nylon anti-rattlers, nylon wing angles & weather strip siliconased brush gasket will be provided. 6mm Clear Toughend Glass (Saint-Gobain / AIS) / Fibre-glass Mesh (Charcoal) infill fitted unto Sash/Frame using micro-wave treated siliconised EPDM gasket. * Wall Thickness - Aluminium: 1.5mm.The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. This cost includes labour, materials, wastage, transportation at site, fixing, fittings, etc. all complete. (Make :- FENESTA/ REKLAD)Ground Floor |
| 518 | First Floor |
| 519 | Second Floor |
| 520 | Third Floor |
| 521 | Forth Floor |
| 522 | 50012212System Aluminum Casement System Door: Double Leaf Swing double glazed door Providing and fixing System Aluminum works for casement systems door having door frame 55mmx40mm, shutter 70mmx40mm, door bottom transom 150mmx40mm, central profile 47.3x42.9mm, grazing bead 31.8mmx17.85mm with glazing of single glass panel without middle transom made of non-euro groove architectural aluminium profile. The extruded aluminums sections should be T6 tempered made from Grade 6063 alloy, approved shade of pure-polyster/ hybrid surface coating Anodized (50-60-micron powder coat), silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. The drainage slots provided at the bottom part of the frame/sash on the outerside & weather strip siliconased brush gasket will be provided. 21mm Clear Toughend DGU (6mm outer + 10mm Air Gap + 5mm inner) Glass (Saint-Gobain / AIS) infill fitted unto Sash/Frame using micro-wave treated siliconised EPDM gasket. The casement systems having hardwares SS handle (22mmx300mm), mortise lock with both side key cylinder, floor spring. Wall Thickness - Aluminium: 1.5mm. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. This cost includes labour, materials, wastage, transportation at site, fixing, fittings, etc. all complete. (Make :- FENESTA/ REKLAD)Ground Floor |
| 523 | 50012708Supplying,Providing & laying full body mat / rustic finish vitrified tile skirting using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 800 x 800 mm of premium quality in walls, risers with tile adhesive of 8 mm tk and fixing with epoxy sealant of MYK or equivallent make to match the shades of the vitrified tile in the 3 mm wide spacer bar, watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect .(Make : Johnson / RAK/SOMANY )Ground Floor |
| 524 | First Floor |
| 525 | Second Floor |
| 526 | Third Floor |
| 527 | Forth Floor |
| 528 | 50012826Providing and applying of pre constructional anti-termite treatment Confirming to IS 6313 (Part-II) and creating chemical barrier under and around the column pits, wall trenches, basement excavation top surface of plinth filling, junction of wall and floors along with external perimeters of building, expansion joints, surrounding the pipes and conducts etc. at the rate at 7,5 liter per sqm on vertical surface and 5.0 liter per sqm on horizontal surface. Chemicals:- Imidachloprid 30.5 SC ,Doses: - 2.1 ml per lit of water cost of all materials , labour , conveyance, TandP , all taxes and hire charges of machinaries as per direction of . (Make :- HI-Solution or Smart Care )Ground Floor |
| 529 | 50012867System Aluminum fixed cum lovoured ventilators – Single Glazed Providing and fixing System Aluminum fixed cum lovoured ventilators– Single Glazed with 50mm and 35mm visible aluminum section width in the center mullion. The extruded aluminums sections should be made from Grade 6063-T5 and Anodized with Tex guard coating, silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. in all meeting points instead of Brush Pile. All materials which are used should be corrosion-resistant so that they are good functioning in different environments and that there are no negative influences either on the aluminum or on the surface treatment.The system should allow the application of frosted glazing or panels with thickness up to 8mm. Part will be fixed, part will be louvered. The external perimeter of aluminum sections should be Anodized with Tex guard coating, the system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. System should have a 10-year warranty on properties, functionality and design, within restrictions defined by technical specifications of anodizing and 1-year warranty on wearing parts only applies to normal and realistically foreseeable use. All Slider windows will be center locking . (Make :- Tostem/ Reclad)Ground Floor |
| 530 | First Floor |
| 531 | Second Floor |
| 532 | Third Floor |
| 533 | Forth Floor |
| 534 | 50012885(Single Glazed Structural glazing ) Designing, getting it vetted by any IITs, Providing and Fixing NCL Seccolor Structural Glazing fabricated from Roll formed sections made of Pre-painted Steel / Powder coated (Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 Gm/Sqm) with total coated thickness of 0.72mm. The glass holding section made of 304 grade stainless steel of 0.58mm thick. Galvanized steel sections are to be sued as stiffeners inside the colour coated steel/powder coated sections as per the design requirement. Design calculations are made of suit wind pressures as given in IS 875. Primer coat with epoxy primer of 5 – 7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick. Min sectional information is as follows.The vertical section should be min of 50mm x100mm x 0.72mm, 33mm x 58mm x 0.72mm for frame horizontal section, stiffener section should be 48mm x 98mm x 1mm, cover profiles sections should be of 20mm x 58mm x 0.58mm, Glass holding section should be of 37mm x 37mm and 37mm x 18mm.Brackets made of CRCA powder coated/Electroplated should be used to connect vertical to horizontal, vertical to slab, to fix verticals at top and bottom as per site requirement. Gasket made of Ethyl Propylene Diamine Monomer. Natural cure, with Good U.V. Resistance Silicon to be used. Wall fixing of sections to concrete/masonry wall should be with self-expanding cap and scre to be fixed with 6mm thick Toughened reflective glass. (Make :- NCL Glass-Saint Gobain/Asahi reflective glass of designed shade )Ground Floor |
| 535 | 50012913Single leaf 2 hour rated Metal Fire door Providing and fixing,testing of fire rated GI Sheet doors conforming to FD 120-I 30 classification of IS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accressesories like hardware, vision panel, fire and smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door and its fire rating. The door must carry a 5years valid test evidence from CBRI-Roorkee / NTH-Kolkata/ NABL accrediated lab which operates in accordance with ISO/IEC 17025. The Door frame shall be single rebate grooved profile of size minimum 100mm x 57mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembeled with bolting system. Frames to have inbuilt grooved to accomodate Intumuscent fire seal strip . The frame should also be provided with fire rated EPDM smoke seal 20x4 mm conforming to IS: 3614:2021 or as per test evidence. It shall be fixed in grooves, specifically cut in rebate on all the 3 sides of the frame.. All provisions should be mortised and provided with necessary inbuilt reinforcement to receieve appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves(Payable in extra item) for installation of frame in finished plastered masonary wall opening. Note :- For grouting of Steel frames in masonary installations ;cement sand mixture 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be recommended except head member(Payable in extra item). Single leaf insulated fire rated door of FD 120 classification IS 3614:2021 with 120 minutes integrity and 30 minutes insulation - For staircase/exit pathway application / Refuge area. – Door frame fixed to exit opening with 10 nos. fasteners and door assembly must be provided with 1 no. single point panic bar and external trim with key cylinder, 1 no. door closer with spring. Every Glass pane must carry a permanent marking of its glass manufacturer . (Make :-TATA Pravesh)Ground Floor |
| 536 | First Floor |
| 537 | Second Floor |
| 538 | Third Floor |
| 539 | Forth Floor |
| 540 | 50012988Providing 16mm. thick finished kota stone flooring using kota stone of approved quality, colour and size above 0.10 sqm in floors, treads on steps and landing on 20mm. thick bed of cement mortar mix of (1:4) with screened and washed sharp river sand for mortar and cement of approved quality, grouted with neat white cement slurry laid in proper slope joining the Kota stone with neat white cement slurry mixed with required quantity of pigment of approved marks to match the shades of the kota stone to kota colour if required, watering and curing for the required period , including cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries, TandP required for the work including cost of rubbing mechanically and wax polishing etc complete in all floors at all height in all respect.Ground Floor |
| 541 | 50012997Providing 16mm. thick finished kota stone in dado/skirting using kota stone slab above 0.10 sqm of approved quality, colour and size in dado, risers of steps on 12mm. thick bed of cement mortar mix of (1:3) with screened and washed sharp river sand for mortar and cement of approved quality, grouted with neat white cement slurry laid in proper slope mixed with required quantity of pigment of approved marks to match the shades of the kota tiles to kota colour if required, watering and curing for thr required period, including cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries, TandP required for the work including rubbing mechanically and wax polishing etc. in all floors at all height complete in all respect.Ground Floor |
| 542 | 50013046Expansion Joint Treatment:Providing, fitting and fixing of Sikadur Combiflex SG 20P 200 and sealed by Sikadur 31C @ 1.4kg per meter over the expansion joints after cleaning the joints and applying of Sikadur 32 @ 200 gms per meter Epoxy bonding agent and levelled by Sikagrout 214 @ 8kg per meter and covered with 300mm wide 16 gauge Aluminium sheet. The voids to be filled up with Durabord HD100 at the time of Castry of RCC beam / Slab / Cloumns. The work to be complete including cost, conveyance, of all materials, labour, transportation charges etc complete in all respect as per specification and direction of the Engineer-in-charge. (Make:- MYK or Sika or BASF)Ground Floor |
| 543 | 50013154Providing and lying plain cement concrete of (1:2:4) in foundation and floors using 12 mm. Size black hard crusher broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.Ground Floor |
| 544 | 50013251Supplying, Fitting & Fixing of full body Vitrified Tile (SUPER PREMIUM QUALITY) on floors of size 600mm x 1200mm x 10 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free, coefficient of friction greater than 0.34. Make: (JOHNSON MARBONITE/ SOMANY DURASTONE/ KAJARIA E-SHIELD)Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/DULUX (epoxy grout) [NSWI]Ground Floor |
| 545 | First Floor |
| 546 | Second Floor |
| 547 | Third Floor |
| 548 | Forth Floor |
| 549 | 50014833Providing and laying in position R.C.C. M-30 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC COLUMNS)Ground Floor |
| 550 | First Floor |
| 551 | Second Floor |
| 552 | Third Floor |
| 553 | Forth Floor |
| 554 | Fifth Floor |
| 555 | 50014844Providing and laying in position R.C.C. M-30 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS).First Floor |
| 556 | Third Floor |
| 557 | 50015706Providing and laying in position R.C.C. M-30 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB)(Centring taken 10 Sqm/1Cum RCC)Third Floor |
| 558 | 50015744Providing and laying in position R.C.C. M-30 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR LINTEL BEAM)(Taking centring 14 sqm/1Cum RCC)Third Floor |
| 559 | 50015780\\"Providing and laying in position R.C.C. M-30 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC STAIRCASE) (Taking centring 9Sqm/1Cum RCC)Third Floor |
| 560 | 50015800\\"Providing and laying in position R.C.C. M-30 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC FLOOR BEAMS)(Taking 8sqm/1Cum RCC)Third Floor |
| 561 | 50016226Earth work in excavation by mechanical means in hard rock (Blasting Prohibited)as per technical specification clause no-302.Ground Floor |
| 562 | 50016411\\"Providing & laying over the PCC surface a HDPE based waterproofing white composite sheet membrane, 1.5 mm AquaArm PowerPrufe 900W , when tested as per ASTM D 3767, consisting of high density polyethylene film/sand blasted surface, a pressure sensitive adhesive .The membrane shall form an integral, adhesive and permanent bond to poured concrete to prevent water migration at the interface of the membrane and structural concrete and shall include dual adhesive tape lap seam technology to complete side laps and end lap shal be hot air weded method for parmanet sealing of over lap joints using lister gun to secure adjacent sheets.The HDPE membrane shall be terminated on the vertical surface of the raft keeing 100 below from the top surface with DS tape and finally fixing with aluminium channel. HDPE Membrane shall be applied with following steps and as per manufacturer recommendation: 1) Cleaning of PCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc. 2) HDPE Membrane laid over the PCC and continued over the side of raft, vertical portion of retaining wall and over the kicker joint should be properly terminated as per manufacturer recommendations .The membrane shall have the following physical properties:1) Resistance to hydrostatic head +/- 70 Mtr as per ASTM D 5385,2) An elongation of minimum 500% as per ASTM D 412.3) Tensile Strength : 29+-5 MPa as per ASTM D 412, 4) Peel adhesion to Poured-in-Place Concrete : >1500 N/m – ASTM D 903 5) Lap adhesion minimum 1m5 N/m; ASTM D1876 6) The membrane shall have a puncture resistance not less than +/-1000 N as per ASTME154, MYK/FOSROC\\"Ground Floor |
| 563 | 50016413\\"Treatment of Construction Joints and Cracks: Chase opening the Construction joints in required groove size and filled with cement sand mortar admix with polymer admixed Rearm bond 45 in the ratio of 10% by weight of cement to make polymer modified mortar and tie rod holes over embedded part of steel support for sheet piling with polymer mortar admixed with aforesaid bonding agent. All tie rod holes shall be cut tnto groove of 25mm inside and sealing the same with Polymer modified mortar. Waterproofing Membrane: Providing and applying 1.5mm thick Aquaarm SBS 3000X- self adhesive SBS membrane over the outside portion of retaining wall after application of single coat of Aqua Arm Tar primer - bituminous primer on the entire vertical surface. The SBS membrane shall be terminated on the vertical surface above 150mm of the earth filling level by fastening of aluminium channel into the concrete. The membrae shall be protected by 8mm thick dimple sheet before filling of earth. M YK/FOSROC\\"(MYK/FOSROC)Ground Floor |
| 564 | 50016417Surface preparation: Removal of existing loose contamination from the surface by griding and wire brusing to get the proper finish surface. Covong shall be provided at the junction of the vertical x horizontal level with cement sand mortar admix with Rearm bond 45- SBR base polymer @ 10% by weight of cement. MYK/FOSROC Treatment of Construction Joints and Cracks: Chase opening the Construction joints in required groove size and filled with cement sand mortar admix with polymer admixed Rearm bond 45 in the ratio of 10% by weight of cement to make polymer modified mortar and cure the surfcae with water properly.MYK/FOSROC Bore Packing :Providing and sealing the gaps in the core cuts around PVC pipes treated with SBR bonding agent & sprinkled sand; filling the core using a non shrink grout ArmGrout M 65E followed by sealing of the joint of pipe nad grout by using with Epoxy putty ReArm Bond UW.MYK/FOSROC Pond Test: Carrying out pond test over the entire area shall be conducted by keeping water stagnant for 48 hours. If at all leakage/ seepage areas are found, it shall be marked and all those areas to be treated with pressure grouting with cement slurry admixed with non-shrink additives Armgrout Additive at low pressure of max upto 2 to 2.5 kg/sqcm.MYK/FOSROC Injection Grouting : providing and fixing 12mm dia PVC nozzle along the construction joint and where ever nacessary by Rearm fix 10S- plugging compound. Then injection of cement slurry admix with Arm grout addetive @ 250gm/bag of cement through the nozzle till the refusal of grout pump.MYK/FOSROC Waterproof Coating: Providing and applying two coats of Aquarm 2C- two componant polymer modified elastomaric coating over the RCC surface, mixing part I&II homognously and apply by brush at an interval of 24 hrs. The coating shall go upto 300mm of the vertical wall from the FFL level. The Product should have the followinhg properties. 1. Elongation : 80% ( as per ASTM 412) 2. Tensil Strength: 0.4 N /MM2 3. Crack bridging : upto 1mm 4. Pull out bond strength: 1.5 N/mm2 concrete failure. MYK/FOSROC Protective Screed: Providing and laying Concrete screed on horizontal surface of required thickness using M 20 grade concrete admixed with Integral waterproofing compound AquaArm Proof IWP 10 @150gm/bag of cement. (Contractor's scope).MYK/FOSROC Protective Plaster: providing and laying avg. 15 mm thick, CM 1:4 plaster admixed with Integral Waterproofing Compound Aquaarm Proof WP 10 of MYK Arment or equivalent @ 150 ml / bag of cement on vertical surface. (Contractor's scope)MYK/FOSROCGround Floor |
| 565 | 50016427Surface preparation: Cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout and preparation of surface in all aspects to receive the waterproofing. MYK/FOSROC Treatment of Construction Joints and Cracks: Chase opening the Construction joints in required groove size and injecting cement slurry admixed expanding grout admixture ArmGrout Additive @250 gm per bag of cement within the prefixed nozzles under pressure using grout pump to fill all possible pores. (pressure of 2 to 2.5 kg/sqcm). Grooves should be filled with cement – sand mortar mixed with ReArm SBR 45 @ 5 % by weight of cement.MYK/FOSROC Bore Packing / Core Cut Treatment: Preparing the inside surface of core and PVC by roughening using suitable file to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Applying a coat of styrene- butadiene based polymer coating using ReArm SBR 45 to enhance adhesion between the packing material and other surfaces and packing the gap using non- shrink cement polymer based grout using ArmGrout M-65 E upto the surface of the bore whilst the ReArm SBR 45 is in tacky state and then sealing with epoxy putty ReArm Bond UW. MYK/FOSROC Coving: Providing and Applying Cement Mortar admixed with ReArm SBR 45 @ 5% by the weight of cement all around the junction between roof slab and parapet wall of size 50 mm x 50 mm. MYK/FOSROC Pond Test: Carrying out pond test over the entire area shall be conducted by keeping water stagnant for 48 hours. If at all damp areas are found, it shall be marked and all damp areas to be treated with pressure grouting with cement slurry admixed with non-shrink additives Armgrout Additive at low pressure of max upto 2 to 2.5 kg/sqcm.MYK/FOSROC Application of Primer: Apply FloArm Primer PUDC on dry concrete surface (ensure moisture level does not exceed 5%) by the help of brush. MYK/FOSROC Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single component polyurethane based waterproofing system AquaArm SPU-SPL of MYK Arment or equivalent . It has to be applied @2 kg/sqm in two coats.The membrane will have the following technical parameters: Solid Content: 90%, Tensile Strength : 2 N/mm2 ,. Elongation at break : 500% , Adhesion To concrete: >2 N/mm. MYK/FOSROC Sprinkling of sand shall be done, after the application of second coat, when the second coat is in tacky condition.MYK/FOSROCGround Floor |
| 566 | 50016437Providing and laying plain cement concrete 1:3:6 (1 cement: 3 sand: 6 stone aggregate 40mm nominal size) as levelling course in foundationand plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.(FOR BASEMENT FROM 1.5M TO 4.5M DEPTH BELOW G.L)(AS PER ANALYSIS OF RATES 2006,PAGE NO-68).Ground Floor |
| 567 | 50016439Providing and laying in position R.C.C. M-30 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(><<)>(>,<(><<)>)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability withoutimpairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING) (Taking centring 1.5Sqm/1Cum)(FOR BASEMENT FROM 1.5M TO 4.5M DEPTH BELOW G.L)(AS PER ANALYSIS OF RATES 2006)PAGE NO--68Ground Floor |
| 568 | 50016441Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. FOR BASEMENT FROM 1.5M TO 4.5M DEPTH BELOW G.L)(AS PER ANALYSIS OF RATES 2006)PAGE NO--68Ground Floor |
| 569 | 50016451Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and Plinth (FOR BASEMENT 1.5M TO 4.5M ANALYSIS 2006,PAGE-70)Ground Floor |
| 570 | 50016529MCM TRAVENTINE STONE :- Providing and Fixing of MCM Modified Clay Material ‐ MCM TRAVENTINE STONE 1200 x 600 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation ‐ Class A— ASTM E84‐ 15.The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in‐charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in‐charge.Ground Floor |
| 571 | 50016955Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202(Part-1) decorative type ,core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design incliuding cost of all door fitting and fixtures etc.cpmpleted. (Make: Century/Green ) and hardware fittings(Godrej /Dorset)Ground Floor |
| 572 | First Floor |
| 573 | Second Floor |
| 574 | Third Floor |
| 575 | Forth Floor |
| 576 | 50017587Providing and Fixing Unistone or equivalent premium Da Vinci Cultured Stone in Khondalite natural stone pattern & shade & approved size in 20mm thickness, ±2mm accepted tolerance along with corner pieces at all corners of building in sizes, as available with manufacturer. The pattern should replicate natural stone appearance using differential textured mould technique and pigmentation should be done by infusion methodology to infuse surface with authentic natural tones. Dual or triple tone shading cultured stone should be casted using homogenous base pigmentation with top layer differential shade penetration technique to simulate ultra ‐ realistic natural stones. The pattern should have variation in shade and have hints of rust, rust browns, copper, umbers and deep yellows to simulate actual stone.The material should be castedin controlled production environment concrete mixdesign with high pressure vibratory methodology, 43 – grade OPC white Cement, reinforced with Alkali Resistant Glass fibre1.5 %, The glass fibre shall be alkali resistant (AR) with minimum Zirconium Dioxide (ZrO2) content of 16% and shall be manufactured by approved manufacturer as per specification of approved make i.e., by M/s N.E.G Japan or Owens Corning. The stone cladding cultured stone should be pigmented with synthetic mineral iron oxide non fading weatherproof, UV resistant pigments of M/s Pheno chem, Lanxessor equivalent and it.The products hould be applied on rough plastered substrate(1:3) Cement and Coarse Sand and should be applied with Unistone ‘Ultimate’ or equivalent Exterior Grade high strength cementitious polymer modified tile adhesive having tensile adhesion strength ≥ 2.5 N / mm2 as per EN ‐1348. The product should be applied with adequate grooves and all horizontal and vertical grooves to be filled and pointed with a mix offine sand and cement in ratio (3 Fine sand: 1 Cement). All work should be carried out as per manufacturer’s and as per direction of Engineer in charge.(8 \\" x 12 \\") SizeGround Floor |
| 577 | 50018055Aluminum Fixed Curtain Glazing (Double Glazed) :- Providing and fixing Anodized System Aluminum curtain glazing of TOSTEM / NCL ALLURO / ALUMIL make, suitable for 1.6 KPA wind load. The extruded aluminium sections should be made from Grade 6063-T5 & Anodized with Tex guard coating. Corner connection will be Butt joint with using Nano gaskets for sealing. There shall be no visible joineries in any intermediate section. All other major Accessories should also be made by the same manufacturer. The outer frame Depth will be 100 +/- 5 mm with minimum transom / mullion size of 100 mm x 70 mm or 200 x 70 for height exceeding 3000 mm. All glasses will be 22 mm DGU Ref Toughened ST-146 and to be fixed from outside only. The system should allow glass thickness up to 10 mm. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 1600 Pa.Ground Floor |
| 578 | 50018057Supply, Installation of Powder Coated Louvers with Outer frame as 25 mm x 50 mm x 1.5 mm tubular frame and Channel suitable to Louver Panels with Panel dimension as 56.5 mm without bend with wall thickness as 2 mm with two nos of screws grooves. Outer frame shall be Cut into Rectangular or Square sizes or as per site requirements with mitered joints and CSK screws. Main frames shall be fixed onto the Civil openings with approved make HFV anchor fasteners of M10x80. Louver Panels shall be fixed onto the main frames by SS Screws of PH M10x50 of approved make.Ground Floor |
| 579 | 50018059Providing and fixing Terracotta Clay brick tile in size 9\\" x 3\\" in approved pattern, and shade. TheTerracotta Clay brick tile shall have texture and shade of natural brick. The thickness ofTerracotta Clay brick tile shall be between 12 – 15 mm having weight of approximately 2.5-3 Kg per Sq Ft. The material casting should take place in FRP Moulds. The fixing ofTerracotta Clay brick tile should take place on rough plastered surface of 1:6 (cement: coarse sand) with Dual fixing procedure i.e. exterior grade Cement polymer based tile adhesive ‘UniStone Ultimate’ or equivalent to be applied with exterior grade cement polymer based grout in matching brick tile shade to be used to tile group. The cost inclusive of installation, fixingof material ,loading and unloading ,scaffolding etc.)Ground Floor |
| 580 | 50018061TERRACOTTA MURALS :- Supplying,fitting,fixing and installing of High Terracotta mural as per the approved design and specified size approved by the authorized agency etc.including cost of all labour, material, Tools and plant , equipment, scaffolding , all lead and lift as per the direction of Engineer-in-charge..Ground Floor |
| 581 | 50018071Supplying and installation of rest room cubicles of following types of specification etc. including cost of all labour,material,conveyance , loading and unloading etc all complete as per the direction of Architect/Engineer-in-charge. Thickness of Compact Laminate : 12 m Colour of HPL Boards: Single Colour Size of Cubicle :As per Drawing (W) (D) X 2100mm (H) Door Size : 1925mm (H) x 600mm (W Divider Size : 1945mm (H) Overall Height Of Cubicle : 2100mm (Including bottom Gap of 100mm) Accessories: Standard – Stainless Steel - 304 Grade accessories) a) SS \\"U\\" Channel b) SS \\"F\\" channel (Only Corner Unit) c) SS Door Stopper Channel c) SS Top Rail d) SS Coat Hook e) SS Privacy Thumb turn c/w Occupancy Indicator f) SS Door Knob g) SS Hinges with Cover h) SS Adjustable Foot - 316 Grade i) Rubber Lining for Groove j) S.S.Screws 304 G & P.V.C Wall Plugs SPECIAL NOTE - Warpage Criteria is 3.0 mm/1000mm for MRS panels as per EN standard- 438.Ground Floor |
| 582 | 50018267AQUAGUARD (80 PSS UV) 2000 litre capacity water storage tanksGround Floor |
| 583 | MIS-CVL-PATHWAY&PA |
| 584 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 585 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 586 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 587 | 50001701Providing and laying 80 mm thick Factory made cement concrete interlocking Paver block of M40 grade made by block making machine with strong vibratory compaction and approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coares sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-In-Charge.Ground Floor |
| 588 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 589 | 50011883Construction of Granular Sub-Base (Gr-IV) by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401of MoRT&H specifications for Road & Bridge Works (4th Revision). Vide AR-2006, Page-160,Item-39 .Ground Floor |
| 590 | 50013548Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.Ground Floor |
| 591 | 50013554Loosening, Levelling and compacting the original ground supporting to embankment to facilitate placement of 1st layer of embankment scarified to a depth 150mm, mixed with water at OMC and compacted to achive minimum dry density as given in table 300-2 and Clause 305 of MoRT &H Specifications for Road & Bridge Works .(AR-P/158/37)Ground Floor |
| 592 | 50013578Providing, Laying, spreading & compacting graded stone aggregate of to W.M.M. specifications including premixing material with water at OMC in mechanical mix plant and carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub-base/base course on well prepared surface and compacting with VRR to achive the desired density as per Clause 406 of MoRT&H specifications for Road & Bridge Work (4th Revision).(AR-P-166/42).Ground Floor |
| 593 | 5001828340mm thick fine dressed stone flooring over 20mm thick base with CM 1:5 White sand stone.Ground Floor |
| 594 | MIS-CVL-RECHARGEPI |
| 595 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 596 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 597 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 598 | 50000019\\"25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. \\"Ground Floor |
| 599 | 50000488Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and PlinthGround Floor |
| 600 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 601 | 50001726Supplying, filling or Spreading of filling sand by mechanical means including cost of all labour,material T & P etc. complete as per the direction of Engineer-in-charge.Ground Floor |
| 602 | 50003066\\"Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of ownrigs with its accessories, tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).(Labour for drilling) ,(REVISED). \\"Ground Floor |
| 603 | 50003070\\"Lowering the 200mm dia size PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position,including cutting and threading pipe and slotted pipe and supplying and fixing all jointing materials,tools and plant etc.complete and keeping the top of the casing pipe threaded including plugging tubewells to prevent entry of foreign materials from above.(REVISED) \\"Ground Floor |
| 604 | 50003086HDPE Pipes 32/40 mm ( High Density PVC pipes inner dia 32mm, outer dia 40mm, 6Kg/ Cm Sqr. With IS specification (Detail cost per 1 meter)(REVISED)Ground Floor |
| 605 | 50003158\\"Supplying all labour, tools and plant and materials for cleaning and developing the tubewell with compressor continuously washed till clean and adequate discharge is obtained from the tube well including supply and use of necessary equipments and labour complete in all respect as per the direction of the Engineer-in-Charge.(FOR HAND BORING WORK)Detail cost per 1 set (0-360mtr).(REVISED)Ground Floor |
| 606 | 50003162Cost of P.V.C (A S T M SCHEDULE-80) pipe 150mm/125mm (ASTM D-1785) Make-Oriplast, Hariplast.(REVISED)Ground Floor |
| 607 | 50003176\\"Supplying all labour, tools and plant and packing the bore with washed gravel (size P-6) around the pipes in good quality including cost of gravel etc all complete as per the direction of the Engineer-in-charge.Detail cost per 1 set (0-360mtr)(REVISED).Ground Floor |
| 608 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 609 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 610 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 611 | 50013560Providing filter media with 40-90mm stone aggregate and sand etc.Complete(AR-P-143/10)Ground Floor |
| 612 | MIS-CVL-RENOVATION |
| 613 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 614 | First Floor |
| 615 | Second Floor |
| 616 | Third Floor |
| 617 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 618 | First Floor |
| 619 | Second Floor |
| 620 | Third Floor |
| 621 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 622 | First Floor |
| 623 | Second Floor |
| 624 | Third Floor |
| 625 | 50000084\\"Dismentaling of R.C.C.columns,beams,slab,staircase,landing and lintels including stacking the useful materials for reuse within 50 mtr.lead. \\"Ground Floor |
| 626 | 50000085\\"Dismentaling & removing Doors,Windows and ventilators including removal of frames,hings,fastening & stacking the same for reuse and removing the debries within 50mtr. lead.\\"Ground Floor |
| 627 | 50000089\\"Dismantling and removing 2.5cm. thick grading concrete from roof slab cleaning the surface lowering and removing the debrises with 50m. lead. \\"Third Floor |
| 628 | 50000870Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris with in 50m lead.Ground Floor |
| 629 | First Floor |
| 630 | Second Floor |
| 631 | 50001765Scarping Plaster in Lime or Cement Mortar from Brick/ Stone Masonry including T&P, sorting the dismantled aterial, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres.Ground Floor |
| 632 | First Floor |
| 633 | Second Floor |
| 634 | Third Floor |
| 635 | 50001767Scarping and removing of old paint from wall wood and iron works before applying the new coats of paints including T&P, sorting the dismantled aterial, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres.Ground Floor |
| 636 | First Floor |
| 637 | Second Floor |
| 638 | Third Floor |
| 639 | 50002762Dismantling and removing old tile cladding from walls including racking out joints 12mm deep, stacking of the materials for reuse and removing the debris within 50m leadGround Floor |
| 640 | First Floor |
| 641 | Second Floor |
| 642 | 50010572Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500)Ground Floor |
| 643 | First Floor |
| 644 | Second Floor |
| 645 | Third Floor |
| 646 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 647 | First Floor |
| 648 | Second Floor |
| 649 | Third Floor |
| 650 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 651 | First Floor |
| 652 | Second Floor |
| 653 | Third Floor |
| 654 | 50010608Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean).Ground Floor |
| 655 | First Floor |
| 656 | Second Floor |
| 657 | Third Floor |
| 658 | 50010620Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY)Ground Floor |
| 659 | First Floor |
| 660 | Second Floor |
| 661 | Third Floor |
| 662 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 663 | First Floor |
| 664 | Second Floor |
| 665 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 666 | First Floor |
| 667 | Second Floor |
| 668 | 500108152.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete.Third Floor |
| 669 | 50010975Providing and finishing the wall surface with texture paint finish with approved materials of texture powder used @ 0.30Kg/Sqft of approved shade including scaffolding, cost of all materials and labour. [NSWI] Texture Paint brand:-ASIAN (Duracast Dholpurtex)/BURGER (Ruff-n-Tuff Decora Finish - Dholpur Cols)/DULUX (ultrafine honeycomb).Ground Floor |
| 670 | First Floor |
| 671 | Third Floor |
| 672 | 50011486Supplying, Fitting & Fixing of Anti-Skid Vitrified Tile (PREMIUM QUALITY) on floors of size 600mm x 600mm x 9 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free. Make: (JOHNSON ENDURA/ SOMANY TECHSTONE/ KAJARIA (STONE)) Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout) (NSWI SPECIAL)Ground Floor |
| 673 | First Floor |
| 674 | Second Floor |
| 675 | 50011516Providing, Fixing & Fitting Ceramic glazed tiles (PREMIUM QUALITY) on wall of size 300mmx600mm of approved shade on 12mm thick cement mortar of mix (1:3) and grouted with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect. (JOHNSON/SOMANY/KAJARIA) (NSWI SPECIAL)Ground Floor |
| 676 | First Floor |
| 677 | Second Floor |
| 678 | 50012056System Aluminum Sliding Windows – Single Glazed (With MESH): Providing and fixing System Aluminum works for Sliding windows with sash 65x27mm, mesh sash 65x27mm, made of non-euro groove architectural aluminium profile. The extruded aluminums sections should be T6 tempered made from Grade 6063 alloy, approved shade of pure-polyster/ hybrid surface coating Anodized (50-60-micron powder coat), silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. All Slider windows will be center locking of aluminium/zamark. Integrated Anti-lift in slider panel, Frame width shall be 80 mmx45 for 3 track (2 Glazed panels and 1 Mesh panel track provision) with +/- 2mm maximum tolerance. Provision of mesh track must be inbuilt in the offered system. The drainage slots provided at the bottom part of the frame/sash on the outerside, single wheel nylon fixed rollers, nylon anti-rattlers, nylon wing angles & weather strip siliconased brush gasket will be provided. 6mm Clear Toughend Glass (Saint-Gobain / AIS) / Fibre-glass Mesh (Charcoal) infill fitted unto Sash/Frame using micro-wave treated siliconised EPDM gasket. * Wall Thickness - Aluminium: 1.5mm.The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. This cost includes labour, materials, wastage, transportation at site, fixing, fittings, etc. all complete. (Make :- FENESTA/ REKLAD)Ground Floor |
| 679 | First Floor |
| 680 | Second Floor |
| 681 | 50012212System Aluminum Casement System Door: Double Leaf Swing double glazed door Providing and fixing System Aluminum works for casement systems door having door frame 55mmx40mm, shutter 70mmx40mm, door bottom transom 150mmx40mm, central profile 47.3x42.9mm, grazing bead 31.8mmx17.85mm with glazing of single glass panel without middle transom made of non-euro groove architectural aluminium profile. The extruded aluminums sections should be T6 tempered made from Grade 6063 alloy, approved shade of pure-polyster/ hybrid surface coating Anodized (50-60-micron powder coat), silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. The drainage slots provided at the bottom part of the frame/sash on the outerside & weather strip siliconased brush gasket will be provided. 21mm Clear Toughend DGU (6mm outer + 10mm Air Gap + 5mm inner) Glass (Saint-Gobain / AIS) infill fitted unto Sash/Frame using micro-wave treated siliconised EPDM gasket. The casement systems having hardwares SS handle (22mmx300mm), mortise lock with both side key cylinder, floor spring. Wall Thickness - Aluminium: 1.5mm. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. This cost includes labour, materials, wastage, transportation at site, fixing, fittings, etc. all complete. (Make :- FENESTA/ REKLAD)Ground Floor |
| 682 | 50012826Providing and applying of pre constructional anti-termite treatment Confirming to IS 6313 (Part-II) and creating chemical barrier under and around the column pits, wall trenches, basement excavation top surface of plinth filling, junction of wall and floors along with external perimeters of building, expansion joints, surrounding the pipes and conducts etc. at the rate at 7,5 liter per sqm on vertical surface and 5.0 liter per sqm on horizontal surface. Chemicals:- Imidachloprid 30.5 SC ,Doses: - 2.1 ml per lit of water cost of all materials , labour , conveyance, TandP , all taxes and hire charges of machinaries as per direction of . (Make :- HI-Solution or Smart Care )Ground Floor |
| 683 | 50012867System Aluminum fixed cum lovoured ventilators – Single Glazed Providing and fixing System Aluminum fixed cum lovoured ventilators– Single Glazed with 50mm and 35mm visible aluminum section width in the center mullion. The extruded aluminums sections should be made from Grade 6063-T5 and Anodized with Tex guard coating, silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. in all meeting points instead of Brush Pile. All materials which are used should be corrosion-resistant so that they are good functioning in different environments and that there are no negative influences either on the aluminum or on the surface treatment.The system should allow the application of frosted glazing or panels with thickness up to 8mm. Part will be fixed, part will be louvered. The external perimeter of aluminum sections should be Anodized with Tex guard coating, the system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. System should have a 10-year warranty on properties, functionality and design, within restrictions defined by technical specifications of anodizing and 1-year warranty on wearing parts only applies to normal and realistically foreseeable use. All Slider windows will be center locking . (Make :- Tostem/ Reclad)Ground Floor |
| 684 | First Floor |
| 685 | Second Floor |
| 686 | 50013241Supplying, Fitting & Fixing of full body Vitrified Tile (SUPER PREMIUM QUALITY) on floors of size 600mm x 600mm x 10 mm with s elf-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete.The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free, coefficient of friction greater than 0.34. Make: (JOHNSON MARBONITE/ SOMANY DURASTONE/ KAJARIA E-SHIELD)Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/DULUX (epoxy grout) [NSWI]Ground Floor |
| 687 | First Floor |
| 688 | Second Floor |
| 689 | 50016417Surface preparation: Removal of existing loose contamination from the surface by griding and wire brusing to get the proper finish surface. Covong shall be provided at the junction of the vertical x horizontal level with cement sand mortar admix with Rearm bond 45- SBR base polymer @ 10% by weight of cement. MYK/FOSROC Treatment of Construction Joints and Cracks: Chase opening the Construction joints in required groove size and filled with cement sand mortar admix with polymer admixed Rearm bond 45 in the ratio of 10% by weight of cement to make polymer modified mortar and cure the surfcae with water properly.MYK/FOSROC Bore Packing :Providing and sealing the gaps in the core cuts around PVC pipes treated with SBR bonding agent & sprinkled sand; filling the core using a non shrink grout ArmGrout M 65E followed by sealing of the joint of pipe nad grout by using with Epoxy putty ReArm Bond UW.MYK/FOSROC Pond Test: Carrying out pond test over the entire area shall be conducted by keeping water stagnant for 48 hours. If at all leakage/ seepage areas are found, it shall be marked and all those areas to be treated with pressure grouting with cement slurry admixed with non-shrink additives Armgrout Additive at low pressure of max upto 2 to 2.5 kg/sqcm.MYK/FOSROC Injection Grouting : providing and fixing 12mm dia PVC nozzle along the construction joint and where ever nacessary by Rearm fix 10S- plugging compound. Then injection of cement slurry admix with Arm grout addetive @ 250gm/bag of cement through the nozzle till the refusal of grout pump.MYK/FOSROC Waterproof Coating: Providing and applying two coats of Aquarm 2C- two componant polymer modified elastomaric coating over the RCC surface, mixing part I&II homognously and apply by brush at an interval of 24 hrs. The coating shall go upto 300mm of the vertical wall from the FFL level. The Product should have the followinhg properties. 1. Elongation : 80% ( as per ASTM 412) 2. Tensil Strength: 0.4 N /MM2 3. Crack bridging : upto 1mm 4. Pull out bond strength: 1.5 N/mm2 concrete failure. MYK/FOSROC Protective Screed: Providing and laying Concrete screed on horizontal surface of required thickness using M 20 grade concrete admixed with Integral waterproofing compound AquaArm Proof IWP 10 @150gm/bag of cement. (Contractor's scope).MYK/FOSROC Protective Plaster: providing and laying avg. 15 mm thick, CM 1:4 plaster admixed with Integral Waterproofing Compound Aquaarm Proof WP 10 of MYK Arment or equivalent @ 150 ml / bag of cement on vertical surface. (Contractor's scope)MYK/FOSROCGround Floor |
| 690 | 50016427Surface preparation: Cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout and preparation of surface in all aspects to receive the waterproofing. MYK/FOSROC Treatment of Construction Joints and Cracks: Chase opening the Construction joints in required groove size and injecting cement slurry admixed expanding grout admixture ArmGrout Additive @250 gm per bag of cement within the prefixed nozzles under pressure using grout pump to fill all possible pores. (pressure of 2 to 2.5 kg/sqcm). Grooves should be filled with cement – sand mortar mixed with ReArm SBR 45 @ 5 % by weight of cement.MYK/FOSROC Bore Packing / Core Cut Treatment: Preparing the inside surface of core and PVC by roughening using suitable file to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Applying a coat of styrene- butadiene based polymer coating using ReArm SBR 45 to enhance adhesion between the packing material and other surfaces and packing the gap using non- shrink cement polymer based grout using ArmGrout M-65 E upto the surface of the bore whilst the ReArm SBR 45 is in tacky state and then sealing with epoxy putty ReArm Bond UW. MYK/FOSROC Coving: Providing and Applying Cement Mortar admixed with ReArm SBR 45 @ 5% by the weight of cement all around the junction between roof slab and parapet wall of size 50 mm x 50 mm. MYK/FOSROC Pond Test: Carrying out pond test over the entire area shall be conducted by keeping water stagnant for 48 hours. If at all damp areas are found, it shall be marked and all damp areas to be treated with pressure grouting with cement slurry admixed with non-shrink additives Armgrout Additive at low pressure of max upto 2 to 2.5 kg/sqcm.MYK/FOSROC Application of Primer: Apply FloArm Primer PUDC on dry concrete surface (ensure moisture level does not exceed 5%) by the help of brush. MYK/FOSROC Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single component polyurethane based waterproofing system AquaArm SPU-SPL of MYK Arment or equivalent . It has to be applied @2 kg/sqm in two coats.The membrane will have the following technical parameters: Solid Content: 90%, Tensile Strength : 2 N/mm2 ,. Elongation at break : 500% , Adhesion To concrete: >2 N/mm. MYK/FOSROC Sprinkling of sand shall be done, after the application of second coat, when the second coat is in tacky condition.MYK/FOSROCGround Floor |
| 691 | 50016955Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202(Part-1) decorative type ,core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design incliuding cost of all door fitting and fixtures etc.cpmpleted. (Make: Century/Green ) and hardware fittings(Godrej /Dorset)Ground Floor |
| 692 | First Floor |
| 693 | Second Floor |
| 694 | 50017599\\"Providing and Fixing Unistone or equivalent premium Da Vinci Cultured Stone in Laterite natural stone pattern & shade & approved size in 20 mm thickness, ± 2mm accepted tolerance along with cornerpiecesat all cornersof buildinginsizes, as available with manufacturer.The pattern should replicate natural stone appearance using differential textured mould technique and pigmentation should be done by infusion methodology to infuse surface with authentic natural tones. Dual or triple tone shading cultured stone should be casted using homogenous base pigmentation withtop layer differential shade penetration technique to simulate ultra‐realistic naturalstones. Thepattern should have variation in shade and have hint so frust, rustbrowns,copper,umbers and deep yellows to simulate actual stone.The materials hould be caste dincontrolled production environment concrete mixdesign with high pressure vibratory methodology, 43 – grade OPC white Cement, reinforced with Alkali Resistant Glass fibre1.5 %, The glass fibre shall be alkali resistant (AR) with minimum Zirconium Dioxide (ZrO2)content of 16% and shall be manufactured by approved manufacturer as per specification of approved make i.e., by M/s N.E.G Japan or Owens Corning. The stone cladding cultured stone should be pigmented with synthetic mineral iron oxide non fading weather proof, UV resistant pigmentsofM/sPhenochem,Lanxessor equivalent and it.The products hould be applied on rough plastered substrate(1:3) Cement and Coarse Sand and should be applied with Unistone‘Ultimate’ or equivalent Exterior Grade high strength cementitious polymer modified tile adhesive having tensile adhesion strength ≥ 2.5 N / mm2 as per EN ‐1348. The product should be applied with adequate groove sand all horizontal and vertical grooves to be fille dand pointed with a mixoffine sand and cement in ratio (3 Fine sand: 1 Cement). All work should be carried out as per manufacturer’s and as per direction of Engineer in charge. (8\\"\\" x 12\\"\\" , 12\\"\\" x 10\\"\\" , 14\\"\\" x 12\\"\\" ) Size \\"Ground Floor |
| 695 | 50018055Aluminum Fixed Curtain Glazing (Double Glazed) :- Providing and fixing Anodized System Aluminum curtain glazing of TOSTEM / NCL ALLURO / ALUMIL make, suitable for 1.6 KPA wind load. The extruded aluminium sections should be made from Grade 6063-T5 & Anodized with Tex guard coating. Corner connection will be Butt joint with using Nano gaskets for sealing. There shall be no visible joineries in any intermediate section. All other major Accessories should also be made by the same manufacturer. The outer frame Depth will be 100 +/- 5 mm with minimum transom / mullion size of 100 mm x 70 mm or 200 x 70 for height exceeding 3000 mm. All glasses will be 22 mm DGU Ref Toughened ST-146 and to be fixed from outside only. The system should allow glass thickness up to 10 mm. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 1600 Pa.Ground Floor |
| 696 | 50018059Providing and fixing Terracotta Clay brick tile in size 9\\" x 3\\" in approved pattern, and shade. TheTerracotta Clay brick tile shall have texture and shade of natural brick. The thickness ofTerracotta Clay brick tile shall be between 12 – 15 mm having weight of approximately 2.5-3 Kg per Sq Ft. The material casting should take place in FRP Moulds. The fixing ofTerracotta Clay brick tile should take place on rough plastered surface of 1:6 (cement: coarse sand) with Dual fixing procedure i.e. exterior grade Cement polymer based tile adhesive ‘UniStone Ultimate’ or equivalent to be applied with exterior grade cement polymer based grout in matching brick tile shade to be used to tile group. The cost inclusive of installation, fixingof material ,loading and unloading ,scaffolding etc.)Ground Floor |
| 697 | MIS-CVL-SECURITYBL |
| 698 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 699 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 700 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 701 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 702 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 703 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 704 | 50000044Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ).Ground Floor |
| 705 | 50000488Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and PlinthGround Floor |
| 706 | 50000490Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Ground Floor |
| 707 | 50010360Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB)Ground Floor |
| 708 | 50010372Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS)Ground Floor |
| 709 | 50010396Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING)Ground Floor |
| 710 | 50010408Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM)Ground Floor |
| 711 | 50010420Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES)Ground Floor |
| 712 | 50010444Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM)Ground Floor |
| 713 | 50010446Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS)Ground Floor |
| 714 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 715 | 50010572Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500)Ground Floor |
| 716 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 717 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 718 | 50010608Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean).Ground Floor |
| 719 | 50010620Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY)Ground Floor |
| 720 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 721 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 722 | 50010668Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/GreenGround Floor |
| 723 | 50010680Providing and fixing of ISI marked 30 mm thick Flush door Shutters (Single leaf) finished with 1mm thick lamination both side total thickness of 32mm flush door Shutter with 4 Nos SS butt Hinges (125 mm x 85 mm x 5.5 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 1 No SS Aldrop (400mm X 300mm x 16mm dia rod), 1 No Floor type double door stopper, 2 Nos SS Handle of size 150mm, Teak wood Leaping around the edges, 1 No. Back Buffer with all materials,adhesives etc complete. (Excluding door closure, ornamental handle and Mortise Lock). [NSWI] Make:- BWP Flush door (Century Sainik 710 / Green marine gold 710), Laminate (Greenlam/ Centurylam,Marino),Hard ware fittings (Godrej).Ground Floor |
| 724 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 725 | 500108152.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete.Ground Floor |
| 726 | 50010975Providing and finishing the wall surface with texture paint finish with approved materials of texture powder used @ 0.30Kg/Sqft of approved shade including scaffolding, cost of all materials and labour. [NSWI] Texture Paint brand:-ASIAN (Duracast Dholpurtex)/BURGER (Ruff-n-Tuff Decora Finish - Dholpur Cols)/DULUX (ultrafine honeycomb).Ground Floor |
| 727 | 50011029Providing and painting the mural art painting work on wall/floor/ceiling by the selected artist/ agencies to make the art most visible of the stretch. The work includes scraping and cleaning of wall, painting one primer coat and one weather seal coat (Asian/ Berger/Dulux), applying paint for mural art painting. The paint must have a durability of at least 5 years. The cost of the work includes all the labour, man power, scaffolding, transportation, materials required, fooding, etc. for execution of the mural art to give the finish product. It must be noted that, the height shall be calculated from the point where the painting starts till the point it continues and ends. UPTO 3M HEIGHTGround Floor |
| 728 | 50011406Providing and fixing of factory-made 3Track 3Panel UPVC Sliding window (White Colour) frame size 128X50mm and Sash size 45X70mm complete up to and including 1.5m high, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.0mm (+-0.2 mm) duly reinforced with G.I. section 1.5 mm – 2.5 mm (+-0.2 mm), profile shall be manufactured from Tropicalized Blend with TiO2 and required additives. Profile must be colorfast and conform to standard EN12608. The profile sections should have multi hollow (min 2 to 3 chambers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber. The thickness of GI should be selected to meet the wind load requirement as per IS 875- Part III on sash/mullion. Supplier should be submitting wind load calculation & validation complying with IS-875-III before material supply. Minimum steel reinforcement thickness of 1.5mm to 2.5mm. UPVC Windows & Doors must be fabricated with fusion welded /Zip welded corners & must conform to the strength requirements based on wind load as per IS 875-Part III. All hardware fitted should be Non-SS, except handles to be of zinc/Al. alloy casted with powder coated. Glass should be minimum of 5mm clear Toughened Glass (SAINT GOBAIN/AIS) with weather seal (EPDM/TPE). After placing 5 mm clear Toughened glass in the sash, UPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system (holes about 8mm dia to be provided @ 300mm C/C outer side of lower sashes) shall be provided. Window frame will be fixed to the wall with 100mm long and minimum 8mm dia. fasteners and after fixing frame the gap between frame & wall should be filled with silicon sealant (not more than 5 mm x 5 mm) (UV treated silicon for outer frame sealing & Acrylic paintable silicon for inner frame sealing), complete in all respect. Standards & Tests: Follow the British Standard (BS EN 12608, UK, CEPT Ahmedabad, tested by Central Building Research Institute, Roorkee Shriram Institute of Industrial Research, New Delhi. All technical specification having wall thickness of min 2.0 mm(+-.02mm) with TPE gasket, wool pile with rollers, fasteners for fixing frame to finalised wall and necessary screws etc. and glass should be single glass with glazing bead of appropriate dimension. Reinforcement of galvanised mild steel with thick ness of 1.5 mm to 2.5 mm has to put throughout the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with TPE gasket to keep glass tight and unmoved. Multi point locking system (called Pop Up) made out of casted zamac with white powder coated and locking hook will make of SS304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon and having capacity of 40-120 kg depend on glass weight. Fin seal will be provided to protect the dust in between closing point &interlocking point of glass & mesh shutters. Mesh panel (Fibre mesh & SS mesh) can also be provided depending upon the requirements of window and location wise. This cost includes fixing, wastage, transportation, labour, material, etc. complete. (NSWI SPECIAL) Make:(FENESTA/SAINT-GOBAIN)Ground Floor |
| 729 | 50011456Supplying, Fitting & Fixing of full body Vitrified Tile (PREMIUM QUALITY) on floors of size 600mm x 1200mm x 10 mm with self-embossed grooves, Bull nose finished, antiskid properly laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T & P etc required for the works all complete. The surface quality must have free from visible defects(IS-13630-1), class-1 stain resistance, no expansion on moisture, acid & alkali resistace, resistance to house hold chemicals, thermal shock resistance, less than 0.08% water resistance, frost free, coefficient of friction greater than 0.34. Make: (JOHNSON MARBONITE/ SOMANY DURASTONE/ KAJARIA E-SHIELD)Tile Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER(HS Tile grout)/DULUX (epoxy grout) (NSWI SPECIAL)Ground Floor |
| 730 | 50011984Providing granite stone (plane leather finish) of 20mm thick above 0.4sqm on flooring of approved quality and size in staircase floors, kitchen platform including edge moulding and groove cutting etc in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the marble tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties, etc. all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically complete in all respect as per specification.Ground Floor |
| 731 | 50012781Providing & applaying Sika top seal 109 HI over roof slab and parapets before application of SIKA Top seal 109HI the surface should be prime with SIKA 109HI primer , SIKA Fab 1 shall be laid between the coats of water proofing membrame , the entire application cover with SIKA TOP seal HI CC (curing compound) including cost of all materials ,Conveyance, labour, T&P etc. complete in all respect. Make:- SIKAGround Floor |
| 732 | MIS-CVL-SITECLEANI |
| 733 | 50002518Providing & Cutting bushes and leveling the grounding by back end loader (JCB), shifting the debaries 5 km from the site and as per the instruction of EIC.Ground Floor |
| 734 | 50005235Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit. (Girth from 300 mm to 600 mm)Ground Floor |
| 735 | 50005237Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit [ Girth from 600 mm to 900 mm]Ground Floor |
| 736 | 50005655Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts Unit = Sqm (CPWD 2.12,P-217)[N.S.W.I]Ground Floor |
| 737 | 50010877Supplying, filling or Spreading of filling sand by mechanical means including cost of all labour,material T & P etc. complete as per the direction of Engineer-in-charge.Ground Floor |
| 738 | 50016226Earth work in excavation by mechanical means in hard rock (Blasting Prohibited)as per technical specification clause no-302.Ground Floor |
| 739 | MIS-CVL-STP |
| 740 | 50000000Earth work in hard soil or gravelly soil within 50minitial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m depth.Ground Floor |
| 741 | 50000003Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height.Ground Floor |
| 742 | 50000017Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete.Ground Floor |
| 743 | 50000019\\"25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. \\"Ground Floor |
| 744 | 5000002012mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 745 | 500000216mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces.Ground Floor |
| 746 | 5000002216mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height.Ground Floor |
| 747 | 50000043Filling with excavated earth .Ground Floor |
| 748 | 50000490Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure.Ground Floor |
| 749 | 5000171912mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete.Ground Floor |
| 750 | 50005157Supply, installation, testing & commissioning of 1 Nos Stainless Steel Perforated,Corrugated Bar Screen with suitable lifting arrangement (size 500 mm x 1000 mm).Ground Floor |
| 751 | 50005163Supplying, installing, testing and commissioning, consisting fine bubble diffuser along with membrane of SILICON membranes, PVC support pipe(10 ksc pressure rating),PVC fitting, nylon rope braided hose with all accessories to make it retrievable & to provide clog-free oxygen for Aeration Tanks.Ground Floor |
| 752 | 50005167Supply, installation, testing and commissioning of on line electronic sodium hypo chloride dosing sytem dosing pump and Tank etc., The unit shall comprise of the following: Capacity of the dosing Pump - 0-4 LPH Pressure- 4 Kg/cm2 Stroke per minute-55 Dosing Tank- 100 Ltr, Make- E-DOSE/PRO AQUA/KANAKDHARAGround Floor |
| 753 | 50005175Supply, Installation, Testing Commisioning of pipes & Valves with fittings such as tees, crosses, plugs, sockets, elbows, unions, flanges, sleeve pieces, check nuts etc for the entire STP Plant. Inter connecting pipe works with valves for air line- JINDAL/TATA Inter connecting pipe works with valves for water line- UPC/UPVC-SUPREME/FINOLEXGround Floor |
| 754 | 50005177supply, Installation , Testing Commisioning of of MCC Panel (motor control center) to accommodate all the drive units with cabling,glanding within the STP Compartmental , design Indoor wall mounted type with top entry for cable the internal components either Siemen / GE Shall be provided with 1 No. Energy meter. along with cable & Cable tray To receive, control and distribute electrical power at 440 V, 50 Hz, MCC is to be manufactured/assembled as per the latest ISI specification, Indian Electricity Rules, Including special requirements of concerned state electricity inspectorate.The switch board shall be fabricated out of 14 SWG sheet steel and shall be un cubical design.MCC of suitable rating to take care of full load of the sewage treatment plant including all motors and lighting.MCC shall be provided with the following feeders: Incoming Feeder :electronic digital energy meter suitable for full load Voltmeter with selector switch protected through HRC fuses ranging from 0 - 500 V. LED type indication for 3 phases, protected through HRC fuses.Outgoing Feeder :Motor feeder, 1 no. 3 phase and neutral MCCB of suitable capacity to be provided for lighting requirement of STP.Power Cables (LT) for use on 415 V system shall be of 1100 volt grade, Aluminium conductor, PVC insulated as per IS : 1554 (Part I). Motor upto 5 HP copper conductor cable should not be less than 2.5 sq mm of size to be used.Ground Floor |
| 755 | 50005179Commsioning of STP with consumables,Tools & tackles and manpower for 15 days.Test reports for both inlet and outlet in approved lab.Ground Floor |
| 756 | 50005181Supply, installation, testing & commissioning of non clogging sludge transfer pumps with all accessories, motor of required capacity, Pressure gauge on delivery line with control the level of EQT automatically. Pumps shall have following duty: Capcity - 1.0m3/Hr. Head - 10 mwc Motor HP/RPM- 0.5/2900 Make- KIRLOSKAR/LUBI/CG Quantity- 2 Nos (1w + 1 S)Ground Floor |
| 757 | 50005191Supplying, installing, testing and commissioning Consisting of 2 Nos. of centrifugal filter feed pumps (one working + one standby) to feed the treated sewage Water from clarified water tank to Multigrade Filter & Activated Carbon Filter . Flow -4.5 m3/Hr. Head - 30 Mtr. Motor HP/RPM- 1.0/2900 Make- KIRLOSKAR/LUBI/WILO MOC- CI Quantity- 2 NosGround Floor |
| 758 | 50005193Supplying, installing, testing and commissioning of FRP composite Multigrade Filter with Multiport vales. Filter shall be suitable for working pressure of 3.5 kg / cm2 and shall include standard fittings like pressure gauges, sampling cock, etc. Flow Rate- 4.5m3/Hr. Dia x HoS ( mm )- MGF 21 x 62 MOC- FRP COMPOSITE VESSEL Make-TECHLITE/AQUANOMICS/STARLITEGround Floor |
| 759 | 50005195Supplying, installing, testing and commissioning of FRP composite Activated Carbon Filter with five Multiport vales . Filter shall be suitable for working pressure of 3.5 kg / cm2 and shall include standard fittings like pressure gauges, sampling cock, etc. Flow Rate-4.5m3/Hr. Dia x HoS ( mm)- ACF 21 x 72 MOC- FRP COMPOSITE VESSEL Make- PENTAIR/AQUANOMICS/STARLITEGround Floor |
| 760 | 50005199Design Supply, installation, testing and commissioning of MBBR media, and Tube settler to be provided in the areation tank and settling tank. MOC of MBBR Media - Poly Propylene ,Make-COOLDECK/MM AQUA Quanity of FMR Media - 2.0 m3 Tube settler - 3.0 m3Ground Floor |
| 761 | 50005201Supply, installation, testing & commissioning of non clogging sewage transfer pumps with all accessories, motor of required capacity, Pressure gauge on delivery line with control the level of EQT automatically. Pumps shall have following duty: Capcity - 7.5 m3/Hr. Head - 10 mwc Motor HP/RPM- 1/2900 Make- KIRLOSKAR/LUBI/WILO Quantity- 2 Nos (1w + 1 S)Ground Floor |
| 762 | 50005203\\"Supplying, installing, testing and commissioning of Twin Lobe design type air blower complete with motors, pulleys, one piece CI casing and side plates, silencer, base plate, Anti-friction bearings, Rotary oil sealings having horizontal configuration.with electric motor \\"Capacity of Blower- 68 m3/Hr. Head- 0.4 kg/cm2 Motor HP/RPM- 3/1500 Make- A1/AKASH/AIRVAK MOC- CI Air Required for reactor tank- 53Nm3/Hr. Air Required for Equalization tank- 15Nm3/Hr.Ground Floor |
| 763 | 50010470Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel.Ground Floor |
| 764 | 50010572Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500)Ground Floor |
| 765 | 50010584Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900)Ground Floor |
| 766 | 50010596Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC).Ground Floor |
| 767 | 50010608Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean).Ground Floor |
| 768 | 50010620Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY)Ground Floor |
| 769 | 50010644Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel).Ground Floor |
| 770 | 50010656Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink)Ground Floor |
| 771 | 50010716Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing.Ground Floor |
| 772 | 500108152.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete.Ground Floor |
| 773 | 50011700Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS).Ground Floor |
| 774 | 50016144Supply and laying and fixing NP2 250mm dia R.C.C. Hume pipe including cost of all materials & labour charges etc complete including cost,conveyance and royalty etc. complete.Ground Floor |
| 775 | 50018063Providing and supplying Shock, Seismic (C1 & C2), Fatigue and Fire approved, ETA approved HIT-RE500V3 with HIT-V Threaded Rod to use in cracked/uncracked concrete, tested for service temperature of -40 deg. C to +80 deg. C. The product should be approved by ETA, ICC, CSTB, COLA, BZS. Anchoring with HIT-V with RE500V3 to be designed as per guidelines of TR 029. Drilling hole with double flute type drill bits/ hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery operated dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate embedment depth & number of anchors to be calculated as per PROFIS Anchor Software & the report to be submitted to the project manager, design engineer for approval. Scanning with PS250 Scanning Tool before drilling to be done to avoid hitting existing rebars. For zones with high seismicity, seismic designs are mandatory. For shear loads, base plate designed by SOFA, filling sets are mandatory. The rate mentioned includes cost of all labours, materials, conveyance, loading and unloading and T&P etc. HIT-RE 500 V3 with Anchor rod HIT-V- 5.8 M12X150Ground Floor |
| 776 | 50018065Supplying of all Labour,material and equipment for core drilling work of following size and specification as per the direction of En gineer-in-work. Diamond Core Drilling 152 dia and depth of 150 mm on slab.Ground Floor |
| 777 | 50018273\\"Laying in trenches double socket Cast Iron Bends conforming to IS:1538 - 1993 (Part-x) of the following nominal diameter as per specification complete. (Earth work in trenches, jointing of pipes, specials and fittings to be measured and paid separately)80mm dia Cast Iron Bend \\"Ground Floor |
| 778 | 50018281Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of bedding for salt-glazed stoneware pipes of the following internal diameter including curing complete as per specification TYPE- A 1 STANDARD BEDDING 300mm diameterGround Floor |
| 779 | MIS-INE-AREAILLUMI |
| 780 | 40001024Supply and laying of 6 sq.mm 2 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/ Polycab/KEI/gloster)Ground Floor |
| 781 | 40001033Supply and laying of 25 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/Polycab/KEI/Gloster)Ground Floor |
| 782 | 40001126providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18)Ground Floor |
| 783 | 40001367Supply and laying of 16 sq.mm 4 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI)Ground Floor |
| 784 | 40001883Recessed wiring to Gate light Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge .( Make of wire Finolex /Anchor / Havells/V guard) Make-switch /Angle holder-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 785 | 40002155Supply and fixing of 16 sq.mm 04 core PVC Al. Arm Cableof 1.1 KV grade end termination.(Brass compression)Ground Floor |
| 786 | 40002198Construction of light post base with inside opening of following size complete including excavation of pit,PPC Padding,250 mm thick brick walls on all sides,1:6 cement plastering of the wall side,top & complete as required as per electrical engg -in -charge and consultation 300mm x 300mm x 750mmGround Floor |
| 787 | 40002201Supply & fixing of 200x150mmx60mm(nominal) size pvc(SINTEX) looping end box with hinged cover having one no.20 amp rating moulded fuse base &holder, 4amp NS type fuse and 4way connector to be used in the bottom of street light pole for cable termination as per electrical engg -in -charge and consoltant and complite as per electrical engg -in -charge and consultationGround Floor |
| 788 | 40002239Supply and laying of 2.5Sqmm 3 Core Cupper Cable 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick (Make of wire Finolex/L &T/Anchor/Havels/V Guard)Ground Floor |
| 789 | 40002351Supply & errection of 7.0 Mtr galvanized Octagonal pole ,continuosly tapered,single piece,3mm thick,The face to face dimension is 130mm at bottom and 70mm at top dia.base plate.size is 200 x 200 x12 mm thick The pole should be manufactured from special steel plate suitable for lighting Arrangement System ,Galvanized Founation bolt specification of bolt length 600mm circle dia 200mm bolt size 20mm,Template size is 200mm PCD,thickness 3mm with 10/4 Bakelite Cover,63 Amp 4 way Stud Connector-01No,10 Amp SPMCB-01 No,MCB Channel-01 No,Mudguard Nut,Bolt & washer-06 Nos,Aluminium Socket-08 Nos.(make-Bajaj/havells/RR-ISPAT)Ground Floor |
| 790 | 40002353Supply and fixing of 1mtr. Long Galvanized deocartive single arm welded with top canopy at an angle of 120 degree with the pole.The outer dia of arms are 46mm,4 nutbolts suitable for 70mm Top.Ground Floor |
| 791 | 40002493Supplying & installation, testing and commissioning of bollard light 1 to 3 feet height having 8 watt LED luminare (Havell TURIN BOLLARD /Jaguar make Type No-LBLD03R108XW) /PANSONIC(MODEL-PBDM03108/CRO MPTON(MODEL-LBLSR-10CDL)/WIPRO(MODEL-LB14-131-XXX-65-08/PHILIPS)(MODEL-58176 PHILIPS Glide Pedestal Black E27(BULB EXTRA)Ground Floor |
| 792 | 40002497Supply of outdoor type auxillary panel board made out from 20guage thick CR Sheet duly painted with clamping arrangement to be fixed on street light pole equipped with 04 nos bus bar 03 nos indication lamp with 1 No toggle switch ,1 no timer switch , 1 No Stud type 4 way terminal I/P) 63 Amp ) 1 No 63A TPN MCB, 1 No 3 Pole Contractor 65 A, 1 No Single Pole MCB 10A, 3 Nos 16 amp TPN MCB , 3 Nos Stud type , 4 way terminal (O/P) 63A A with earthing arrangement [Make-(a)MCB /MCCB - Legrand/ Schnider/L &T/ ABB, ( b)Volt meter, Ammeter-AE/CAPPA, (d) all other acessories ISI mark]Ground Floor |
| 793 | 40003041Supply, installation, testing and commissioning of GI coil earthing including excavation of earth pit in all kinds of soil/rock filling with charcoal & salt, connections to earthing stids/ bolt of the pole complete including all accesories and connections.Ground Floor |
| 794 | 40003258Supply and laying of 3 Core 1.5 sq.mm. insulated conductor with all accessories and connections.(Make of wire Finolex / L &T /Anchor / Havels/ V guard)Ground Floor |
| 795 | 40005870Supply and laying of 25 sq.mm 3.5 core End termination for Cableof 1.1 KV grade ISI MarkedGround Floor |
| 796 | 40008291Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing)Ground Floor |
| 797 | 40009686Supply & Fixing of 2 core 6 sqmm Cable end terminationGround Floor |
| 798 | 40011619Supply & fixing of 90 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 having LM 79 LM 80 tested including bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire with all accessories . (Make- PANASONIC(MODEL NO-PSTM22908)/HAVELLS(MODEL NO-ENDURA SUNDOWN90W)/CROMPTON(MODEL NO-TRP-412-90-57-SL-LM-NSG)/PHILIPS(MODEL NO-BRP033LED90S 90W 9000LM)/WIPRO(MODEL NO-LR08-102-XXX-57-XXGround Floor |
| 799 | 40012278Supply and fixing of 40mm dia HDPE pipe -PE 80 grade PN-6. 2.0 wall thicknessGround Floor |
| 800 | 40012942Supplying & installation, testing and commissioning of post top lantern of 40 watt LED luminare with all accessories and including connection etc. ( Gate light )(Make-CROMPTON(MODEL NO-LPTO-40-CDL-M (40 WATT)/PHILIPS/WIPRO MODEL NO-LP07-501-XXX-57-C L/PANASONIC(MODEL-PPTM02408)/HAVELLS(MODEL-RUBY 40W)Ground Floor |
| 801 | 40013326Supply & fixing of 10WT LED,4000k (2 WAY)Wall washer light fitting connecting wire with all accessories.(MAKE-PHILIPS(MODEL-800044)/WIPRO( MODEL-LW35-271-029-30UDX)/HAVELLS(MODEL-CLIOWLS15WLED830PSYMTOTG)Ground Floor |
| 802 | 40013334Supply & fixing of 7WT Spike light fitting connecting wire with all accessories.(MAKE-PHILIPS(MODEL-800138/WIPRO(MODEL-LF05-60 0-024-27-XX(8W)/PANASONIC(MODEL-PSKM03 SERIES 6WT SPIKE LIGHT/HAVELLS(MODEL-RVINESPS6WLED830PSYMTGGRY)Ground Floor |
| 803 | MIS-INE-CCTVSYSTEM |
| 804 | 40000982Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 805 | 40001126providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18)Ground Floor |
| 806 | 40002095Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL/VTR All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.Ground Floor |
| 807 | 40003013Supply Wireless Mouse (Make- Logitech)Ground Floor |
| 808 | 40003492Supply,Installation of 3 core 2.5 sqmm cable in rigid PVC pipes per runing meter (Make of wire Finolex/Anchor/Havells/V guard)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 809 | 40008495Supply of 6U wall mounted rack including all accessories and connection(make-D-link(Model no-NWR-6U-5545-GR)/MOLEX/DIGISOL)Ground Floor |
| 810 | 40008505Supply & fixing of cat-6 UTP cable,4 pair,23AWG,FRPVC CM for LAN wiring with conduit pipe / PVC casing caping / under floor G.I. Tunk line. MAKE- D-LINK(MODEL NO-NCB-C6UGRYR)/DIGISOL/MOLEX)Ground Floor |
| 811 | 40009165Supply and installation of 5KVA online UPS system 192VDC with single phase AC input and single phase AC output for 60 Min back up,MS rack for housing the batteries & link cable ,16 nos 12V 42AH SMF batteries(Make-UPS-Numeric (Model-ONFINITI FM)/APC,Make-Batt ery-Exide/Quanta)Ground Floor |
| 812 | 40010311Supply , Installation, testing , commissioning of 64Ch. 4K Network Video Recorder(Instastream/H.265/Smart H.264+/H.264/MJPEG codec decoding, Support 8 SATA HDDs up to 10TB Each,Support Multi-brand network cameras) Make - CP Plus/ PramaGround Floor |
| 813 | 400103134MP WDR 32x IR Network PTZ Camera: 1/2.8\\" 4MP CMOS Image sensor (0.9071 centimeters), Max. 50/60fps@4MP, Powerful 32x Optical zoom and 16x Digital zoom, WDR(120dB), 2D/3D-DNR, Day/Night (ICR), EIS, Electronic Defog, ROI, AGC,AWB, BLC, HLC, IR Range of 150 Mtr., Max 300° /s pan speed, 360° endless pan rotation, Support Face Detection, Make - CP Plus/ PramaGround Floor |
| 814 | 40010317Supply , Installation, testing , commissioning of 24-Port Gigabit Ethernet POE Smart Switch. Make: Netgear/Juniper/ArubaGround Floor |
| 815 | 40010331Supply , Installation of PVC IP55 Junction BoxGround Floor |
| 816 | 40010337Supply , Installation of 24*7 Surveillance sign board (18*12, Sun Vinyl Board)Ground Floor |
| 817 | 40010410Supply , laying of Solid Cat 6 Outdoor Armed (ECCS Tape) Cable Make- D-link/DigisolGround Floor |
| 818 | 40010412Supply , Installation, testing , commissioning of 1KVA Online UPS with Battery Make-Numeric/APC/MicrotekGround Floor |
| 819 | 40011679Providing & fixing Smart LED TV ( Sony Bravia 4K - 65 '' ) Model No KD-65X 82L inclusive of all necessary hardwares, T&P etc. complete including all accessories and connections.(Make-Sony/LG/SAMSUNG)Ground Floor |
| 820 | 40012068SUPPLY OF 17U STANDING RACK INCLUDING ALL ACCESSORIES AND CONNECTION(MAKE-D-LINK(MODEL NO-NFR-17U-6060-BL-SK)/MOLEX/DIGISOL)Ground Floor |
| 821 | 40012278Supply and fixing of 40mm dia HDPE pipe -PE 80 grade PN-6. 2.0 wall thicknessGround Floor |
| 822 | 40012284Supply , Installation of RJ45 Connector Make-D-link/Digisol/MolexGround Floor |
| 823 | 40012473Supply of 15 Meter High Speed HDMI Cable Approved Make: MX/ Liberty/ Kramer/ ExtronGround Floor |
| 824 | 40012786Supply , Installation, testing , commissioning of 4MP Full HD WDR IR Network Bullet Camera featuring a 1/3\\" or 1/2.9\\" CMOS sensor, motorized 2.7-13.5mm lens for 4MP video at 25/30fps, H.265+/H.264+ compression, 120dB WDR, Min-50m IR range, IP67/IK10, Micro SD, PoE. Make - CP Plus (CP-UNC-TC41ZL6C-VMD-LQ)/ Prama (PT-NC346P1-WNRAM-D2)Ground Floor |
| 825 | 40012788Supply , Installation, testing , commissioning of 4MP Full HD WDR IR Network Dome Camera featuring a 1/3\\" or 1/2.9\\" CMOS sensor, motorized 2.7-13.5mm lens for 4MP video at 25/30fps, H.265+/H.264+ compression, 120dB WDR, 30m IR range, IP67/IK10, Micro SD, PoE. Make - CP Plus (CP-UNC-VC41ZL5C-VMD-Q)/ Prama (PT-NC347P1-WNRAM-D2)Ground Floor |
| 826 | 40012887Supply , Installation, testing , commissioning of 8-Port Gigabit Ethernet PoE Smart Switch 2 Dedicated SFP Ports . Make-Netgear/Juniper/ArubaGround Floor |
| 827 | 40013228Supply , Installation, Testing of 8 TB Surveillance HDD, Make- SEGATE/WDGround Floor |
| 828 | MIS-INE-DGSET |
| 829 | 40002185Supply and laying of 300 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(Make Cable- Finolex/ Havells/Polycab/KEI/Gloster)Ground Floor |
| 830 | 40011971Design, supply, erection, testing and commissioning of 500KVA silent type DG set with AMF, 415V three phase 1500 RPM ,50HZ ,6 Cylinder,4 stroke cycle with 4 nos earthing,1250 AMP 4 POLE CHANGE OVER ,ms pipe exhaust system, residual silencer, thermal logging and cladding of exhaust pipe complete , D.G. Plinth & Shed as per specification as required and as per direction of engineer-in-charge. Make- MAHINDRA POWEROL MODEL(2806D-E18TAG1,ENGINE-PERKINS/JAKSON(MODEL-QSM15-G1 &G1 DEVLOPING 594 BHP)Ground Floor |
| 831 | MIS-INE-ELEVATOR |
| 832 | 40000955Recessed wiring to Bulk Head Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 833 | 40000985Point wiring for 5/ 6 amp socket outlet ( Separate) ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 834 | 40001000Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI/RR/POLYCAB) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 835 | 40001015Recessed wiring to submain in 4 x 10 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 4 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI/RR/POLYCAB) CSR SL .No- 1.8.11)(Make of PVC pipe-AKG/NORPACK)Ground Floor |
| 836 | 40001033Supply and laying of 25 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/Polycab/KEI/Gloster)Ground Floor |
| 837 | 40001126providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18)Ground Floor |
| 838 | 40001166Supply and fixing of 63 AMP 4P MCB-1NO,63 AMP,415 V CUTOUT-3 NOS WITH COPPER BUS BAR & INDICATOR ETC including all accessories and connections . [Make-(a) MCB/MCCB- Legrand/L&T/ABB/SCHNIDER(b)- Voltmeter, Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK]Ground Floor |
| 839 | 40005870Supply and laying of 25 sq.mm 3.5 core End termination for Cableof 1.1 KV grade ISI MarkedGround Floor |
| 840 | 40008291Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing)Ground Floor |
| 841 | 40008427Supply and fixing of Bulk Head fitting with 9 wt. LED Bulb including all accessories and connections . (Make- CROMPTON(MODEL NO-LBHP-10-CDL / PHILIPS(MODEL NO-WT202 LED10S 10W 1000LM LED LIGHT BULK HEAD/ WIPRO)Ground Floor |
| 842 | 40013466Supply, Erection, Testing &Commissioning of 10 Passenger, (Ground + 5) floor Machine Room Elevator with ACV3F drive/control for constant load of 680 Kg.,six stops , Automatic Rescue Device, Speed (1.5Meter per second),ACD5-MRL,VF regenerative(closed loop),car finish, push button operation (Nudging), cross flow fan for ventilation, Auto fan cut off, heavy duty vinyl tile flooring, auto central door opening/closing ( All opening on same side), car position indicators, LED scrolling display, LED ceiling lights, auto voice synthesizer, overload alarming device, infrared door closing protection, door time protection, sensor based door movement, emergency alarming system, emergency light, braille push buttons, intercom, stainless steel mirror finished (lift car, lift door & hand rail), Fire rated door with 60 Mins. fire rating, Fireman's switch, Cladding at each stop(both side & top of each entrance with ply & lamination). The Elevator should be suitable for physically challenged persons.The scope of work is Supply, Erection, Testing & Commissioning of Elevator along with all related civil and electrification work. Make of the Elevator :- OTIS/MITSUBISHI/SCHINDLERGround Floor |
| 843 | 40013468Supply, Erection, Testing &Commissioning of 20 Passenger, (Ground + 5) floor Machine Room Elevator with ACV3F drive/control for constant load of 1360 Kg.,six stops , Automatic Rescue Device, Speed (1Meter per second),ACD5-MRL,VF regenerative(closed loop),car finish, push button operation (Nudging), cross flow fan for ventilation, Auto fan cut off, heavy duty vinyl tile flooring, auto central door opening/closing ( All opening on same side), car position indicators, LED scrolling display, LED ceiling lights, auto voice synthesizer, overload alarming device, infrared door closing protection, door time protection, sensor based door movement, emergency alarming system, emergency light, braille push buttons, intercom, stainless steel mirror finished (lift car, lift door & hand rail), Fire rated door with 60 Mins. fire rating, Fireman's switch, Cladding at each stop(both side & top of each entrance with ply & lamination). The Elevator should be suitable for physically challenged persons.The scope of work is Supply, Erection, Testing & Commissioning of Elevator along with all related civil and electrification work. Make of the Elevator :- OTIS/MITSUBISHI/SCHINDLERGround Floor |
| 844 | MIS-INE-FIREFIGHTI |
| 845 | 40001039Supply and laying of 50 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI/Gloster)Ground Floor |
| 846 | 40007914Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following.Horizontal type, end suction , back pul-out pump of cast iron body & bronze impeller with stainless steel shaft,2280lpm 70 meter head, mechanical seal. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required Suitable cement concrete foundation duly plastered..complete in all respects, as required .Make:Wilo / Kiloskar Or Lubi.Ground Floor |
| 847 | 40007916Supplying, installation, testing and commissioning of Diesel Engine Driven Fire Pump, Fixing single/double stage horizontal centrifugal pumping set of the following specifications including vibration elimination pads and six cylinder , radiator cooled engine with pressure reducing valve complete Suitable HP,2280lpm & 70meter head, 1800 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank with 8hour operation capacity, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. Make:Wilo / Kiloskar Or Lubi.Ground Floor |
| 848 | 40007922Providing and Fixing Jockey pump of 180lpm, 70meter head, fixing single/double stage horizontal centrifugal pumping set with volute bronze impeller connected to a TEFC induction motor suitable for 410/440 volts, 3 phase , 50 cycles AC supply as per the details given below.Make:Wilo / Kiloskar Or Lubi.Ground Floor |
| 849 | 40007930Supply, Installation, Testing and Commissioning 250mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti/ Wurth)Ground Floor |
| 850 | 40007932Supply, Installation, Testing and Commissioning 200mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti)Ground Floor |
| 851 | 40007934Supply, Installation, Testing and Commissioning 150mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti/ Wurth)Ground Floor |
| 852 | 40007936Supply, Installation, Testing and Commissioning 100mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti)Ground Floor |
| 853 | 40007938Supply, Installation, Testing and Commissioning 80mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti)Ground Floor |
| 854 | 40007940Providing and fixing of Non return valve 200mm nominal dia cast iron dual plate check valves of PN1.6 including nuts, bolts, 1.5mm thick compressed asbestos gasket including matching flanges .SANT / ZOLOTO / KARTAR.Ground Floor |
| 855 | 40007942Providing and fixing of Non return valve 150mm nominal dia cast iron dual plate check valves of PN1.6 including nuts, bolts, 1.5mm thick compressed asbestos gasket including matching flanges .SANT / ZOLOTO / KARTAR.Ground Floor |
| 856 | 40007944Providing and fixing of Non return valve 100mm nominal dia cast iron dual plate check valves of PN1.6 including nuts, bolts, 1.5mm thick compressed asbestos gasket including matching flanges .SANT / ZOLOTO / KARTAR.Ground Floor |
| 857 | 40007950Providing and fixing of 150mm nominal dia C.I. Butterfly valves conforming to PN 1.6/13095 with nuts, bolts, washers, 3mm thick ins ertion rubber gasket and two matching flanges .SANT / ZOLOTO / KARTARGround Floor |
| 858 | 40007952Providing and fixing of 100mm nominal dia C.I. Butterfly valves conforming to PN 1.6/13095 with nuts, bolts, washers, 3mm thick ins ertion rubber gasket and two matching flanges .SANT / ZOLOTO / KARTARGround Floor |
| 859 | 40007954Providing and fixing of 80mm nominal dia C.I. Butterfly valves conforming to PN 1.6/13095 with nuts, bolts, washers, 3mm thick inse rtion rubber gasket and two matching flanges .SANT / ZOLOTO / KARTARGround Floor |
| 860 | 40007958Supply, installation, testing and commissioning 150mm dia CI `Y' strainer with bronze perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers etc., complete.SANT / ZOLOTO / KARTARGround Floor |
| 861 | 40007960Supply, installation, testing and commissioning 100mm dia CI `Y' strainer with bronze perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers etc., complete.SANT / ZOLOTO / KARTARGround Floor |
| 862 | 40007964Providing and fixing dial type pressure gauge with isolation cock and chrome plated copper pipe at hydrant station.Make - H-Guru.Dial diameter 100 mm calibration 0-15 kg/sp.cmGround Floor |
| 863 | 40007966Supplying and Installation, Testing & Commissioning double flanged vertical air vessel fabricated from 10mm M.S. plate with dished ends from 12mm M.S. plate, outside with one coat of primer and two coats of synthetic enamel paint of approved shade, complete with approved quality and sufficient provision of pressure switches, Pr. Relief Valve, tripod type stand, pressure gauge with ball valve, drain ball valve of 50mm dia with piping complete as required and all other required accessories to operate commonly main fire pump, diesel fire pump and Jockey pump at drop of pressure, automatically at required pressure setting. Recommended dia. : 250 mm,Height of shell : 1000 mm,Working pressure : 19 Kg/cm2,Test Pressure : 28.5 Kg/cm2Ground Floor |
| 864 | 40007968Providing and fixing electrically operated dual type pressure switches with threaded connection for a pressure vessel, complete suitable for 0-15 Kg/Sq.cm model IPS-200 .Make - Dandfos.Ground Floor |
| 865 | 40007972Providing and fixing of 25mm brass ball valve with lever and screwed female ends.(20 kg/cm2)at all level and position .Zoloto/Kartar.Ground Floor |
| 866 | 40007974Supplying and fixing approved make 25 mm dia automatic air release valve suitable for 20kg/sqcm working pressure with necessary fittings complete in all respect at all level and position .Zoloto/Kartar.Ground Floor |
| 867 | 40007980Providing & fixing Two way fire brigade inlet Gunmetal collecting head with 63 mm dia instantaneous type inlet and 150 mm dia flanged outlet fire brigade connection to fire risers (I.S. 904-1965) complete with campanion flange as per table \\"E\\" nuts, bolts, gasket included cutting & welding at all level and position ..Fire shield / KARTARGround Floor |
| 868 | 40007984Supplying,Fixing ,testing and commissioning of compartmentalized common control panel for one diesel,one electic & one jockey pump with mechanical and electrical interlock facility for the fire pumps. All the components shall be housed in a common cubical made of 16 SWG. M.S. sheet with required stiffeners). The panel shall be powder coated of approved color both inside & outside. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height.Make -ASES/LUBI/GREEN POWER .Ground Floor |
| 869 | 40008008Providing and fixing SS landing valve conforming to IS -52290 with 63 mm dia. instantaneous female coupling on the outlet with PVC cap with chain, necessary companion flanges ( as per table \\"E\\") nuts, bolts, washer and gasket complete as per specification. (ISI marked) .SAFE GUARD / KARTAR /Ground Floor |
| 870 | 40008010Providing and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia. B129 30m long high pressure rubber hose type -II to IS. 5132 or nylone braieded polypropelene hose of approve make with 5 mm outlet S.S. nozzle with shut off valve (IS. 884-1969).(Make-SAFE GUARD / KARTAR / SWASTIK)Ground Floor |
| 871 | 40008012Providing and fixing SS coupling 63 mm dia. 15m long rubberized EPDM lined hose including SS male and female instantaneous type coupling approved by fire authority.(Make-SAFE GUARD / KARTAR / SWASTIK)Ground Floor |
| 872 | 40008014Providing and fixing standard short size SS branch pipe with SS nozzle 16 mm dia. outlet with standard instantaneous type 63 mm dia. coupling. (ISI marked) .(Make-SAFE GUARD / KARTAR / SWASTIK)Ground Floor |
| 873 | 40008018Providing and fixing M.S. structural work fabricated from standard sections e.g. M.S. Rounds, angles, channels, GI clamps including cutting to size drilling, welding including insert plates or \\"Hilti/ Wurth fastners of required specification in RCC structural/masonry.Ground Floor |
| 874 | 40008020Providing and fixing fire hose cabinet fabricated from 16 gauge M.S. sheet with locking arrangement and hanging arrangement for accessories painted \\"Fire Red\\" with enameled paint \\"Fire Hose\\" written on front including suitable supports to place 900 mm above ground level properly anchored, approximately size 750x600x250 mm deep (to house two lengths of canvas hose with couplings, branch pipe with nozzle for external hydrants)(Make-Kartar/Newage)Ground Floor |
| 875 | 40008024Providing and fixing Carbon-di-oxide fire extinguishers. Capacity 4.5 kg. ISI Marked.(Make -Fire shield/Kanex/Safex )Ground Floor |
| 876 | 40008026Providing and fixing stored pressure portable (powder type) ABC - 6.0 kg fire extinguishers including all accessories as per latest IS with wall bracket and rawl plug(Make -Fire shield/Kanex/Safex .)Ground Floor |
| 877 | 40008033Providing and fixing of 4kg clean agent type fire extinguishers including all accessories as per latest IS with wall bracket and rawl plug (Make -Fire shield/Kanex/Safex .)Ground Floor |
| 878 | 40008041Supply ,Installation,testing & Commissioning of 2LOOP FIRE ALARM PANEL 32bit microprocessor based intelligent addressable Fire Alarm control Panel LPCB Approved with battery backup.The panel would be modular,decentralized,with minimum 240 character LCD display & for networking.Each loop would be capable to have atleast 99 addressable detectors & devices with 30mins battery backup & battery charger Inbuilt. Make-Honeywell MORLEY IAS/ Apollo /system sensor Or GST .Ground Floor |
| 879 | 40008045Supply, Installation,testing & Commissioning of loop card can be used for one loop i.e. minimum 254 nos of devices.Ground Floor |
| 880 | 40008049Supply ,Installation,testing & Commissioning of Manual Call Point. Make-Honeywell MORLEY IAS/ Apollo /system sensor Or GST .Ground Floor |
| 881 | 40008051Supply ,Installation,testing & Commissioning of flash cum sounder(Hooter).Make-Honeywell MORLEY IAS/ Apollo /system sensor Or GST .Ground Floor |
| 882 | 40008063Supply ,Installation,testing & Commissioning of convensational Smoke /Heat Detector . Make - Agni /ASES Or GSTGround Floor |
| 883 | 40008073Supply and fixing of wall mounting type Auto glow signages of different type like, fire exit with one side arrow /do not use lift in case of fire/Emergency Exit/Staircase Indicating Arrow etc . Sizes :-300x150mm . type .(Make-Prolite autoglow)Ground Floor |
| 884 | 40008091Supply, installation, testing and commissioning of speaker cable Single pair, 2-core, 1.5 sqmm with required conduit,bend,t etc.Make - Finolex Or Polycab.Ground Floor |
| 885 | 40008093Supply, Installation, Testing and Commissioning 65mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti)Ground Floor |
| 886 | 40008095Supply, Installation, Testing and Commissioning 50mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti)Ground Floor |
| 887 | 40008097Supply, Installation, Testing and Commissioning 32mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti)Ground Floor |
| 888 | 40008099Supply, Installation, Testing and Commissioning 25mm nominal dia flange jointed / screwed / welded, M.S. Pipes of Class c (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. (Pipes - Tata/Jindal ,Anchor fastener- Hilti/ Wurth)Ground Floor |
| 889 | 40008103Providing,Fixing ,Testing & Commissioning of 100mm Sprinkler Alarm Valve with all required fittings & accessories . Make - HD Or Tyco Or Kartar .Ground Floor |
| 890 | 40008109Providing ,fixing , testing and commissioning of standard/quick response pendent type Sprinkler quartzoid bulb type with 15mm screwed end connection of 57 deg. C. temperature rating and sprinklers shall be UL Listed.Make - HD, Kartar or Tyco .Ground Floor |
| 891 | 40008716Providing ,fixing , testing and commissioning of 2C X 1.5 sqmm copper armoured FR cable with PVC rigid counduit, shaddles, grips, screws etc complete.Make - (Make of wire Finolex / Anchor /Havells/ V guard/KEI)Ground Floor |
| 892 | 40010208Providing ,fixing , testing and commissioning of flow switch 150mm dia. Make - Honeywell.Ground Floor |
| 893 | 40010693Supplying, Installing, testing and commissioning Drainage Valve of size 50 MM dia with all accessories. (Kartar/Sant)Ground Floor |
| 894 | 40010694Supplying, installing, testing and commissioning of 1200 mm Sprinkler Flexible drop with mounting bracket with 15mm screwed end connection . (Sant/HD)Ground Floor |
| 895 | 40011765SITC of Rubber Expanssion Joint 150mm nominal dia as per BS 5155 ( PN 16) slim seal standared lever operated type with required flanges, nuts, bolts etc. complete.ISI (Kartar/Sant)Ground Floor |
| 896 | 40011767SITC of Rubber Expanssion Joint 80mm nominal dia as per BS 5155 ( PN 16) slim seal standared lever operated type with required flanges, nuts, bolts etc. complete.ISI (Kartar/Sant)Ground Floor |
| 897 | 40011771Supply and fixing of SITC of 4 mm wrapping coating with all accessories.Ground Floor |
| 898 | 40012068SUPPLY OF 17U STANDING RACK INCLUDING ALL ACCESSORIES AND CONNECTION(MAKE-D-LINK(MODEL NO-NFR-17U-6060-BL-SK)/MOLEX/DIGISOL)Ground Floor |
| 899 | 40012343Providing and fixing of Non return valve 250mm nominal dia cast iron dual plate check valves of PN1.6 including nuts, bolts, 1.5mm thick compressed asbestos gasket including matching flanges .SANT / ZOLOTO / KARTAR.Ground Floor |
| 900 | 40012920Supplying, installing, testing and commissioning of 8 Watt Celling speakers with built in line matching transformer, grill flush mounting type in side the utility rooms.(Make-Honeywell/Ahuja)Ground Floor |
| 901 | 40012922Supplying, installing, testing and commissioning solid state Amplifier of 700 W RMS out put in rack, including necessary control wires, jocks etc. complete.(Make-Honeywell/Ahuja)Ground Floor |
| 902 | 40012928Supplying, installing, testing and commissioning of P.A. Console 8 zone shall expandable up to 60 zones , with priority module micro processor based, mixing amplifier, with 6 zone for suitable selection module, power supply unit & goose neck micro phone etc.(Make-Honeywell/Ahuja)Ground Floor |
| 903 | 40012930Supplying, installing, testing and commissioning of P.A. Call station of 8 zones with priority module micro processor based & goose neck micro phone etc shall be located in the reception / security for the announcement necessary communication cable/CAT 6 shall be considered from PA controller to call station .(Make-Honeywell/Ahuja)Ground Floor |
| 904 | 40013072Supplying, Installing, testing and commissioning Gate Valve of size 200MM dia with all accessories. (Kartar/Sant)Ground Floor |
| 905 | MIS-INE-IPPBXSYSTE |
| 906 | 40008495Supply of 6U wall mounted rack including all accessories and connection(make-D-link(Model no-NWR-6U-5545-GR)/MOLEX/DIGISOL)Ground Floor |
| 907 | 40008505Supply & fixing of cat-6 UTP cable,4 pair,23AWG,FRPVC CM for LAN wiring with conduit pipe / PVC casing caping / under floor G.I. Tunk line. MAKE- D-LINK(MODEL NO-NCB-C6UGRYR)/DIGISOL/MOLEX)Ground Floor |
| 908 | 40008507Supply & fixing of patch cord,cat-6,utp,24awg,grey,lszg ,1mtr(Make-D-LINK(MODEL NO-NCB-C6UGRYR1-1-LS)/DIGISOL/MOLEX)Ground Floor |
| 909 | 40010005Supply and Installation of Cat6 I/O Single with Face plate:Tool-less type (Make-D-link/Molex)Ground Floor |
| 910 | 40010007Supply and installation of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking.(Make-D-link/Molex/Digisol)Ground Floor |
| 911 | 40010317Supply , Installation, testing , commissioning of 24-Port Gigabit Ethernet POE Smart Switch. Make: Netgear/Juniper/ArubaGround Floor |
| 912 | 40010412Supply , Installation, testing , commissioning of 1KVA Online UPS with Battery Make-Numeric/APC/MicrotekGround Floor |
| 913 | 40012068SUPPLY OF 17U STANDING RACK INCLUDING ALL ACCESSORIES AND CONNECTION(MAKE-D-LINK(MODEL NO-NFR-17U-6060-BL-SK)/MOLEX/DIGISOL)Ground Floor |
| 914 | 40012819Supply, Installation, Testing & Commissioning of Enterprise-grade IP PBX Embedded IP PBX support up to 500 users, 75 concurrent calls, built-in IVR, voicemail, call recording, zero license cost along with minimum 4-port FXO Gateway for each port allows connection of a separate PSTN line into the IP PBX. Make-Grand Stream/ Matrix Comsec / AsttecsGround Floor |
| 915 | 40012821Supply, Installation, Testing & Commissioning of 10-line support, 4.3\\" color display, HD audio, dual Gigabit ports, PoE, Bluetooth Make-Grand Stream/ Matrix Comsec / AsttecsGround Floor |
| 916 | 40012823Supply, Installation, Testing & Commissioning of 2-line support, HD audio, PoE enabled, dual Ethernet ports, backlit display Make-Grand Stream/ Matrix Comsec / AsttecsGround Floor |
| 917 | MIS-INE-ONGRIDSOLA |
| 918 | 40003442Supply,Installation,Testing & Commissioing of Net Meter in Consultation with Distribution utility.Ground Floor |
| 919 | 40012535Design,Supply,Installation,Testing & Commissioing of Grid Connected Roof top solar PV System(Through net metering)(Make-Solar PV Panel(VIKRAM/WARREE/TATA POWER SOLAR SYSTEM/PANASONIC SOLAR) ,Solar-P.C.U-LUMINOUS/STATCON/MICROTEK/SU-KAM POWER SYSTEM,-MCB-Legrand/L&T,HRC fuse-L&T/ABB,Copper cable-Finolex/Havells/Polycab)Ground Floor |
| 920 | MIS-INE-VCSYSTEM |
| 921 | 40001708Wiring to Loudspeaker with 2x1.5 sqmm stranded copper conductor unarmoured cable for loud speakers clamped with PVC pipe saddles,base etc.on ceiling/wall complete including termination,testing etc as required (Make-Finolex/Anchor/Havells/V-guard)Ground Floor |
| 922 | 40008498SUPPLY OF 9U WALL MOUNTED RACK INCLUDING ALL ACCESSORIES AND CONNECTION(MAKE-D-LINK(MODEL NO-NWR-9U-5545-GR)/MOLEX/DIGISOL)Ground Floor |
| 923 | 40008505Supply & fixing of cat-6 UTP cable,4 pair,23AWG,FRPVC CM for LAN wiring with conduit pipe / PVC casing caping / under floor G.I. Tunk line. MAKE- D-LINK(MODEL NO-NCB-C6UGRYR)/DIGISOL/MOLEX)Ground Floor |
| 924 | 40011224Supply , Installation, testing , commissioning of 8 Port Giga Eth Unmanaged PoE Switch with 6KV surge protection , 150 Watt Make-N etgear/Juniper/ArubaGround Floor |
| 925 | 40013088Supply of Computer CPU with core i5 processor 16gb ram 512/1024SSD/ 13G with Pre loaded windows 11 pro including integrated BT and Wifi and wiried optical mouse and wired keyboard with all accessories. N.B-Manufacturing Authorization Form (MAF) or a single-line confirmation from the OEM regarding the purchased product, including detailed model no & serial numbers , provided directly by the OEM or its authorized officials to verify the genuineness of the product. Make-HP (Pro Mini)/DELL (Pro micro QC M1250)Ground Floor |
| 926 | 40013255Supply and Installation of 98-inch 4K Digital Large Format Display,4K UHD(3840x2160),500 nits,16/7 duty cycle,HDMI,DP,DVI,LAN,RS232,Built-in speakers and 3 Years warranty. Make-LG(98UM5K)/Samsung(QE98C)Ground Floor |
| 927 | 40013362Supply, Installation, Testing and Commissioning of pre-polarized condenser gooseneck microphone with overall length of 450mm or better, with XLR3M-type connector, shall offer radio frequency interference (RFI) shielding against intermodulation from wireless equipment or devices, cardioid microphone capsule with uniform 120° angle of acceptance (-3dB) or better, frequency response of 50 Hz to 20,000 Hz or better and sound input levels handling capability of minimum 130 dBspl or better, nominal equivalent noise level of 26 Dba or better and output shall be low impedance balanced (<(><<)>100 ohms) with current consumption shall be 3 mA or better. Makes: Sennheiser, Clock Audio, RodeGround Floor |
| 928 | 40013364Supply, Installation, Testing and Commissioning of table stand with Microphone modes Toggle on/ off, Push to mute, Push to talk, permanent on for connecting and operating XLR gooseneck microphones with XLR-3F microphone input and an XLR-3M microphone output operating on 48 V phantom power and current consumption of 3.7 mA or better. Makes: Sennheiser, Clock Audio, RodeGround Floor |
| 929 | 40013366Supply ,Installation,Testing and Commisioning of Full HD 1080p @ 60 frames per second PTZ Camera with minimum 20X Optical Zoom and FoV of minimum 57 deg, min 255 Presets.Camera should support simultaneous outputs through Ethernet, HDMI, 3G-SDI & USB 3.0, Audio In and can be controlled via RS232 & 422 In & Out & IP.Panning angle -170° ~ +170°, Tilting angle -30° ~ +90°.The tilting and panning speed of camera should be minimum 200° per second. Camera should support SRT, FreeD Protocol, PoE and Virtual USB Driver.Camera can be controlled and managed through centralised software on network. Quoted model should be BIS, CE, FCC & RoHS Certified with Test Lab Reports. Make:Lumens,Sony,PolyGround Floor |
| 930 | 40013368Supply, Installation, Testing and Commissioning of 12x8 ProDSP Digital Matrix Processor with 12 mic/line inputs and 8 outputs, Twelve channels of AEC ; should include a configurable USB Audio interface; should be able to send out 24 channels of digital audio and can receive 48 channels over the network; should feature 64 bit floating point audio DSP processing, equipped with selectable 48 volt phantom power for the first eight inputs; should have studio grade 24-bit/48 kHz analog-to-digital and digital-to-analog converters, 8 or more DSP Configurator presets; should have Audio system gain: Balanced output: 0 dB, unbalanced output: -6 dB or better, frequency response: 20 Hz to 20 kHz, ±0.2 dB or better, THD + Noise <(><<)>0.01%, 20 Hz to 20 kHz or better, at maximum level, S/N: Analog In to Analog Out >107 dB, 20 Hz to 20 kHz, at maximum balanced output ,Analog In to Digital Out 110 dB, 20 Hz to 20 kHz, at full-scale output , Digital In to Analog Out 115 dB, 20 Hz to 20 kHz, at maximum balanced output , Crosstalk should be <(> <<)>-90 dB @ 20 Hz to 20 kHz, fully loaded; CMRR should be >60 dB typical or better, Input gain adjustment should be -18 dB to +80 dB in 0.1 dB steps, adjustable per input or better; controllable through USB, RS-232 and LAN, operable in upto 50 °C, CE, UL, c-UL, RoHS compliant. Make:Extron ,Ashly,XilicaGround Floor |
| 931 | 40013370Supply, Installation, Testing and Commissioning of 2-Way In-Ceiling Speaker. Should have Woofer - 6 inch, and Tweeter 0.79 inch. Should have Frequency Range: 65 Hz to 20 kHz (-10 dB). Should have Frequency Response: 95 Hz to 15kHz (±3 dB). Should support Transformer Taps 7.5W/ 15W/30Wat 70V, 100V. Should have Sensitivity: 91 dB @ 1W/1m . Should have 50 Watts program power handling. Should have 110° conical coverage. Should be UL 94V-0 flame rated. Compliance: UL 1480, UL 2043, CE, FCC. Make: Crestron ,Pulse Audio,QSCGround Floor |
| 932 | 40013372Supply, Installation, Testing and Commissioning of Class D Amplifier. Should be able to output 4-channel (75W /channel) or 3-channel (75W-75W-150W) or 2-channel (150W/channel) or 1 channel up to 300 W .Should be able to configure on Lo-Z, Hi-Z operation. Should have Frequency Response 20 Hz to 20 kHz ±0.5 dB at 1. Should have S/N Ratio >103 dBA, 20 Hz to 20 kHz. Should have THD+N <(><<)>0.1% at 1kHz. Should have protection against overheating, excessive input, overloaded speaker lines. Should automatically go on standby when no signal is detected. Should have 1x control/connection port to enable/disable standby mode. Compliance: UL, CE, FCC, RoHS/WEEE. Make: Crestron ,Pulse Audio,QSCGround Floor |
| 933 | 40013374Supply, Installation, Testing and Commissioning of 4K wireless presentation and wireless collaboration device. User should be able to share content wirelessly using app, Google Chrome web browser, Miracast screen mirroring technology for latest Windows, Mac, Android and iOS mobile devices. User should be able to share content via wired by using 1x USBC adapter on table with wireless presenter installed at display end User should be able to access the soundbars, cameras, or speakerphones on PC/Laptop conferencing application wireless, via wireless presenter App, Dongle/ Adapter supplied. Should have option to upload minimum 5x image files, which can function as customizable welcome screen, when no content is being shared. Should have network security protocols Active Directory® service authentication, 802.1X network access control, TLS, SSH, AES content encryption and HTTPS. Should be supplied with 1x USB dongle/Adapter using which user can share content via latest iOS, Android, Windows, Mac devices, without the need to download any app, no need to run any plugin or software. Should have 1x HDMI Output, 1x LAN port (to connect to Corporate network) and 2x USB port for peripherals (certified Audio/Video) connection. Should have ethernet port with TCP/IP, UDP/IP, DHCP, SSL, SFTP (SSH File Transfer Protocol). Should be able to create its own Wi-Fi network, for guest users, for content sharing. Content Protection: HDCP 2.2. Compliance: UL, CE, FCC, RoHS/WEEE. (Additional BIS to be shared if applicable). Should be supplied with necessary Wireless table for BYOD & BYOM experience to achieve the pacification. Make: Crestron ,Extron,LightwareGround Floor |
| 934 | 40013376Supply, Installation, Testing and Commissioning of XLR Connector. Make- KrystalGround Floor |
| 935 | 40013378Supply, Installation, Testing and Commissioning of Microphone Cable. Make- KrystalGround Floor |
| 936 | 40013380Supply, Installation, Testing and Commissioning of HDMI Cable-5M Make- HonywellGround Floor |
| 937 | MIS-INE-VRFAIRCOND |
| 938 | 40008648Indoor units complete with cooling coil, electronic expansion valve ,electrical control box, fire resistant metal box protection for Indoor units PCBs and Panel with Auto By Pass Technology, inspection inlet for easy access to the unit, suitable for operation at a power source 1 Phase, 220-230-240V, 50Hz & 3 Phase, 380-400-415V, 50Hz for High Static Ducted Units with other accessories as required for smooth operation of the system of following capacities Wall Mounted Unit /4 way Cassette Unit of 1.59 TR Nominal Capacity(PKFY-P60VLM) Make- Mitsubishi/ TOSHIBA/O-GENERAL)Ground Floor |
| 939 | 40008660Indoor units complete with cooling coil, electronic expansion valve, electrical control box, fire resistant metal box protection for Indoor units PCBs and Panel with Auto By Pass Technology, inspection inlet for easy access to the unit, suitable for operation at a power source 1 Phase, 220-230-240V, 50Hz & & 3 Phase, 380-400-415V, 50Hz for High Static Ducted Units with other accessories as required for smooth operation of the system of following capacities Wall Mounted Unit /4 way cassette unit of 2.02 TR Nominal Capacity Make- Mitsubishi/ Toshiba/O-GeneralGround Floor |
| 940 | 40008664Indoor units complete with cooling coil, electronic expansion valve, electrical control box, fire resistant metal box protection for Indoor units PCBs and Panel with Auto By Pass Technology, inspection inlet for easy access to the unit, suitable for operation at a power source 1 Phase, 220-230-240V, 50Hz & & 3 Phase, 380-400-415V, 50Hz for High Static Ducted Units with other accessories as required for smooth operation of the system of following capacities Wall Mounted Unit /4 way cassette unit Of 3.2 TR Nominal Capacity(PLFY-P100VEM) Make- Mitsubishi/ TOSHIBA/O-GENERAL)Ground Floor |
| 941 | 40010064SITC of Indoor units complete with cooling coil, electronic expansion valve, electrical control box, fire resistant metal housing box protection for Indoor units PCBs, Auto By Pass Technology, inspection inlet for easy access to the unit, suitable for operation at a power source 1 Phase, 220-230-240V, 50Hz as well as other accessories as required for smooth operation of the system of the following capacities along with Panel. (Make: Mitsubishi /Toshiba/O-General 4.5 TR Four Way Cassette UnitGround Floor |
| 942 | 40010588Refrigirant copper pipe joints.Ground Floor |
| 943 | 40011278Indoor units complete with cooling coil, electronic expansion valve, electrical control box, fire resistant metal box protection for Indoor units PCBs and Panel with Auto By Pass Technology, inspection inlet for easy access to the unit, suitable for operation at a power source 1 Phase, 220-230-240V, 50Hz & & 3 Phase, 380-400-415V, 50Hz for High Static Ducted Units with other accessories as required for smooth operation of the system of following capacities Wall Mounted Unit/4-way Cassette Nominal Capacity of 2.5 TR Make- Mitsubishi/ TOSHIBA/O-GeneralGround Floor |
| 944 | 40011282SITC of Indoor units complete with cooling coil, electronic expansion valve, electrical control box, fire resistant metal housing box protection for Indoor units PCBs, Auto By Pass Technology, inspection inlet for easy access to the unit, suitable for operation at a power source 1 Phase, 220-230-240V, 50Hz as well as other accessories as required for smooth operation of the system of the following capacities along with Panel. (Make: Mitsubishi /Toshiba/O-General) 4.0 TR Four Way Cassette UnitGround Floor |
| 945 | 40011286Cordless Remote Controller for Wall Mounted & Cassette units (Make: Mitsubishi /Toshiba-Carrier)Ground Floor |
| 946 | 40011665Supply of Air Cooled Type Variable Refrigerator Flow System based on 100% Inverter scroll Compressor with linear capacity control , IPM Technology, VET Technology, PWM overmodulation control , unique HIC Circuit , self diagnostic auto check , auto restart, built in Auto Phase Reversal & Auto Bye pass Function, Inverter start technology complete with R410A refrigerant based Outdoor & Indoor units wired /wireless central remote controllers, refrigerant connectors & Joints, copper rfrigeretor piping , control <(><<)>(>&<(><<)>)> transmission wining condensate drain piping and other acessories as required and detailed in the secification. VRF OUTDOOR UNIT Modular type imported low noise outdoor condensing units, comprising of own made Low Pressure Shell type Inverter based Multi valve Scroll Compressor housed in a separate Fire protected enclosure, 6 Pole Motor, Induction type Heater , Suction Gas Cooled Compressor Motor Accumulator , Blue fin treated condensr coil for corrision resistant BLDC Condensor fan motor , high ESP and low noise aerodynamic condenser fan, protection device for inverter circuit (Comprssor/fan) and fan motor, capable to operate at a temperature range of 15 degree centigrade to 52 degree centigrade.(Cooling mode) ambient condition. Capacity: 10 HP Cooling only inverter scroll (Make-Mitsubishi/TOSHIBA/O-Genearl)Ground Floor |
| 947 | 40012327Supply of Air Cooled Type Variable Refrigerator Flow System based on 100% Inverter scroll Compressor with linear capacity control , IPM Technology, VET Technology, PWM overmodulation control , unique HIC Circuit , self diagnostic auto check , auto restart, built in Auto Phase Reversal & Auto Bye pass Function, Inverter start technology complete with R410A refrigerant based Outdoor & Indoor units wired /wireless central remote controllers, refrigerant connectors & Joints, copper rfrigeretor piping , control & transmission wining condensate drain piping and other acessories as required and detailed in the secification. VRF OUTDOOR UNIT Modular type imported low noise outdoor condensing units, comprising of own made Low Pressure Shell type Inverter based Multi valve Scroll Compressor housed in a separate Fire protected enclosure, 6 Pole Motor, Induction type Heater , Suction Gas Cooled Compressor Motor Accumulator , Blue fin treated condensr coil for corrision resistant BLDC Condensor fan motor , high ESP and low noise aerodynamic condenser fan, protection device for inverter circuit (Comprssor/fan) and fan motor, capable to operate at a temperature range of 15 degree centigrade to 52 degree centigrade.(Cooling mode) ambient condition. Capacity: 20 HP Top Discharge ODU inverter scroll (Make-Mitsubishi/TOSHIBA/O-General)Ground Floor |
| 948 | 40013475Supply, Installation, Testing & Commissioning of the above VRF system including Refrigerant Copper Piping line with insullation between Outdoor to Indoor Units, Drain piping, Communication Cable, Supporting, Channel, Nitrogen Leakage Testing, Vaccumizing,R-410A Gas Charging etc.Ground Floor |
| 949 | 50014253Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering<(>,<)>fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel-JINDAL/NIPPON of premium quality, Signage-3M (90CM EQUILATERAL TRIANGLE)#Ground Floor |
| 950 | 50014255Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (80cmX60cm Rectangular)Ground Floor |
| 951 | 50014257Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (60cm circular)Ground Floor |
| 952 | 50014259Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (90cm circular size)Ground Floor |
| 953 | 50014261Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (60CmX45Cm Rectangular)Ground Floor |
| 954 | 50014263Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (90 cm high octagon)Ground Floor |
| 955 | 50014265Manufacturing, supplying and fixing retro reflective sign boards made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 25mmx25mm along with theft resistant measures, mounted and fixed with 2 Nos. S.S. square tube of 25mmx25mm to a vertical post made up of S.S. tube schedule 40 of 40mm dia tube welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 40mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. Make: steel- JINDAL/NIPPON of premium quality, Signage-3M (60X60 cm square)Ground Floor |
| 956 | 50014267Manufacturing, supplying and fixing informative retro reflective sign boards/ prismatic retro reflective information sign board made up of 3 mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c and screws and anchor bolts including making holes in plates, providing & fixing ACP message plate of required size. The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect to fix on the wall. Make: steel- JINDAL/NIPPON of premium quality, Signage-3MGround Floor |
| 957 | 50014269Manufacturing, supplying and fixing retro reflective sign boards (single side) 8’x6’ made up of 3mm thick aluminium composite panel sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of S.S. tube schedule40 of size 40mmx40mm along with theft resistant measures, mounted and fixed with 4 Nos. S.S. square tube of 40mmx40mm to a vertical post made up to S.S. tube of schedule 40 of 50mm dia welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, flats, providing & fixing ACP message plate of required size. The post of the board will be 50mm dia SS tube of schedule40 grade The cost includes labour, material, civil works for fixing, buffering, fabrication, wastage, transportation, high intensity retro reflective sheet, finishing, etc. complete in all respect. FOR 2 VERTICAL POSTS. Make: steel- JINDAL/NIPPON of premium quality, Signage-3MGround Floor |
| 958 | a) APPROVED MAKE /BRAND FOR CEMENT : ULTRATECH, NUVOCO, ACC, JSW (PSC),RAMCO(PSC),DALMIA(PSC),SAGAR(PSC),JK SUPER(PSC),JINDAL PANTHER(PSC) |
| 959 | APPROVED MAKE / BRANDS ARE TO BE UTILISED STRICTLY DURING EXECUTION OF ABOVE RELATED ITEMS OF WORK Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 16, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Dec 01, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender