Drinking Water Supply and Sanitation Government Departments Closing in 6 days TDR #58489282

Tender For Construction Of Ph Section Office Madhiapali And Boundary Wall At Kesherkela Pump House, Balangir

Issued by Government Departments · Balangir, Odisha
Tender Value
64.94 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
6 days left
EMD
64943
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Ph Section Office Madhiapali And Boundary Wall At Kesherkela Pump House, Balangir

BOQ

Name of Work:- Construction of PH Section office Madhiapali and boundary wall at Kesherkela pump house, Balangir
Sl. No. Item Description
1Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. comp
2Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted sec
3Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all
4Cement Concrete (1:2:4) with 12mm.size & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.
5R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 250 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concreFooting
6Plinth Beam
7R.C.C. ColumnsGround floor
81st Floor
92nd floor (Head room)
10Lintel Ground floor
111st Floor
122nd floor (Head room)
13Roof Beam Ground floor
141st Floor
152nd floor (Head room)
16R.C.C. Roof Slab Ground floor
171st Floor
182nd floor (Head room)
19R.C.C Stair Ground floor
201st floor
21Rigid smooth centering & shuttering for R.C.C. works including false works and dismantlling them after casting including cost of materials complete.Footing
22Plinth Beam
23R.C.C. Columns Ground floor
241st Floor
252nd floor (Head room)
26Lintel Ground Floor
271st floor
282nd floor (Head room)
29R.C.C. Roof Beam Ground Floor
301st Floor
312nd floor (Head room)
32R.C.C. Stair caseGround floor
33First floor
34R.C.C. Roof SlabGround floor
351st Floor
362nd floor (Head room)
37Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills Ground floor
381st Floor
392nd floor (Head room)
40Fly ash bricks masonary incm (1:6) after immersing the bricks 6 hrs. in water before use in Foundation and plinth having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
41Fly ash bricks masonary in cm (1:6) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.Ground floor
421st Floor
432nd floor (Terrace)
4412 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.(Outside Wall Surface)Ground floor
451st Floor
462nd floor (Terrace)
4716 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall SurfaceGround floor
481st Floor
492nd floor (Terrace)
506mm thick cement plaster in C.M. [1:4] finished smooth to exposed R.C.C. work with cost of all materials labor etc. complete. Ground floor
511st Floor
522nd floor (Head room)
53Priming one coat with any approved primer including cost of all labour, materials T & P with taxes, transportation etc all complete.Ground floor
541st Floor
552nd floor (Head room)
56Finishing wall surface of walls with Acrylicwall putty (Water based ) of approved makeand finished smooth and even surface toreceive painting including cost of scaffoldingstaging charges with cost of all materialstaxes, labour T&P etc complete as per Engineer-in-chargeGround floor
571st Floor
582nd floor (Head room)
59Finishing wall surface with plastic emulsion paint 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge. Ground floor
601st Floor
612nd floor (Head room)
62Finishing wall surface with weather coat 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge. Ground floor
631st Floor
642nd floor (Head room)
65Fixing Vertified floor tiles of premium grade having thickness 8 mm to 10 mm confirming to IS:13756 of following sizes in floors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete including cost of Tile. Ground floor
661st Floor
67Fixing Vertified floor tiles of premium grade having thickness 8 mm to 10 mm confirming to IS:13756 of following sizes into dados skirting & risers of steps on 12mm. thick C.P (1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles.Ground floor
681st Floor
69Fixing Tiles in floors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles all complete with cost of precast tiles. Ground floor
701st Floor
71Fixing Tiles to dados skirting & risers of steps on 12mm. thick C.P (1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles all complete with & without cost of precast tiles.Ground floor
721st Floor
73Fixing Chequred Tile in floors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete
74Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia. Of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and stainless square pipe of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification etc all completed.
75Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD) Casement Window with top fixed - 60-Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mm x 2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile and 74 mm x 60 mm x 2.5 mm mullion profile capable of mounting sigle glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duty fixed EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No. per set sashes and the system is to be inshtalled at the using anchor fasteners, sillicon rubber sealant, easy glazing/ degilazing at site etc. including cost and conveyance of all materials, acessories, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards,.....(W)
76Providing fitting and fixing in position M.S. window Grill with M.S. flat and angles of approved drawing and design including cutting bending the angles and flats to proper sizes welding, chamfering etc. including cost, conveyance, royalties and taxes of all materials, cost of all labour, sundries and T&P etc. required for the work complete, as per direction of the Engineer in charge.
77Enamel Painting two coats with any approved paint including cost of all labour, materials T & P with taxes, transportation etc all complete as per direction of EIC.Ground floor
781st Floor
792nd Floor
80Providing fitting, fixing of Al. door with anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member with frame section as 9221 with tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc. complete excluding cost of laminated board.
81Providing fitting and fixing of PVC door shutters of approved design and specification including all cost, conveyance and taxes of all materilas, all labour, all T&P sundries required for the work as per the direction of the Engineer-in-charge.
82Providing fitting, fixing of false celling with Aluminium anodized T section No. 3215 with 2'-0\\" centre to centre, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2'-0\\" x 2'-0\\" suspended from ceilling including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete.
83Supplying all materials, labour, T&P for fitting and fixing of all electrical accessories for complete Internal Electrification work including Concealed wiring to light point / fan point / exhaust fan point / call bell point, submain wiring,junction box, provision for ceiling rose,piano type switch, sockets on metal box,RCCB and MCCB arrangements,Distribution Panel,adequate LED lighting arrangements inside and outside,Chemical earthing,Fans etc. all complete as per direction of EIC.(Add 10% for EI work)
84Supplying all materials, labour, T&P for water supply, S/I, S/D work including fitting fixing of all PH Fixtures for complete PH work as per direction of EIC.Construction of 20 users septic tank size - ( 3.00m x 1.0m x 1.50m liquid depth ) detailed estimate enclosed (Annexture - \\"B\\"
85Construction of OHT of Ground Floor detailed estimate enclosed (Annexture - \\"C\\")
86Supply fitting and fixing of 2000 litre capacity Triple Layer white Cylinderical Vertical water storage tanks (ISI Marked) (including cost of 2000 ltr PVC Tank/Triple Layer)
87Supplying all materials, labour and T&P for construction of 1.20mtr.dia.x1.50mtr. Deep soak-way pit with dry brick walling up to 1.10mtr. height and brick work with cement mortar (1:6) for 0.45mtr. height of wall at top,cement plaster (1:3) inside and outside,inside filled with dry brick khoa of 50mm.to 100mm.size to a height of 2.00mtr.from bottom, covered by means of 40mm.thick R.C.C. perforated slab,50mm.thick R.C.C.well cover in pieces fitted with iron rings including earth work in excavation and refilling of cavity around the pit etc. all complete as per approved design and drawing.
88Supplying all materials ,Labour,T & P and laying in treanches PVC pipe ( 4Kg/cm2) as sewer line and alinging to requisite gradients inside the trench, jointing with solvent cement ,0.08m sand filling in bed , 0.10m C.C ( 1:4:8) using 40 mm size hbg metal in bed , C.C ( 1:2:4 ) with 12 mm chips for 0.05 m in bed & intermediate pillar @ 3.0 Mtr interval including lowering the pipes to the bed of trench, Earthwork in excavation in all kind of soil ,Filling the trenches with excavated earth with watering and ramming and removal of surplus earth, testing of sewer lne etc.complete as per the direction of Er.in charge. i) 110 mm OD PVC pipe SWR pipe(Type B)
89Construction of Inspection Chamber of internal size-(0.75mx0.75mx0.45m) Including RCC Cover slab as per P.H. Specification.
90Construction of Man hole Chamber of internal size-(0.9mx0.9mx0.9m) Including RCC Cover slab as per P.H. Specification.
91Supplying all materials ,Labour,T & P and fixing SWR PVC pipe type B & fitting to wall with nails , clamps and wooden plug as per P.H specification & the direction of Engineer in charge.110 mm SWR PVC pipe type B
9275mm SWR PVC pipe type B
93110mm dia Bend Plain
94110mm dia Tee with Door
95110mm dia Single Y with door
96110mm dia Vent Cowl
97110mm dia P.V.C. Nahani Trap
98Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete.
99Providing and fixing to wall or celing and floor P.V.C pipe ( Sch-80)/6 Kg/cm2 of the following nominal dia including cost of G.I fittings,clampc including making good the damages to wall ,celling & floor etc complete as per specification in ground floor20 mm diameter ( Sch-80)
10025 mm diameter ( Sch-80)
101Fixing of Brass or Gun Metal Full Way Valve conforming to IS:781-1995 of the following nominal sizes with wheel as per specification complete.25mm dia Gun Metal Full Way Valve
102Providing, fixing, fitting of following Brass / Gun metal/Chromium plated fitting of approved reputed make (conforming to respective I.S. specifications ) including the jointing materials, if any all complete as per the PHE specification and the direction of the Engineer-in-charge. E.W.C. with P-trap
10323\\" I.W.C.(Orissa Pan)
10422\\"x 16\\"(550x400) W.H.B
105Standard Pedestal for WHB
106Urinal Large- half stall urinal flat back 580x380x350 mm(Magnum type)White
10710 litr pvc low level cistern with fittings
10815 mm dia CP Short body Bib cock -
10915 mm dia CP Long body Bib cock
11015mm dia c.p concealed stop cock
11115 mm CP 2 way Bib Cock
112Health Foucet with 1.2 mtr Flexible Tube with wall hook
11315 mm dia CP Pillar cock
11415mm dia c.p.angular stop cock
115600mm x 450mm Bevelled Edge Mirrior
116600 mm long Single CP Towel Rail
117C.P. Towel Ring round
118600mm long C.P.Shelf with Glass
119CP Soap dish holder
120140mm dia CP Over head Shower
121CP Arm for Over head Shower
122C.P.gratings
12332mmx 1150mm long PVC waste pipe
12415mmx600mm PVC connection pipe
12532mm dia CP waste Coupling
126C.P. flange
127plastic seat and cover
128100mm size ‘P’ or ‘S’ trap
12925 mm PVC Ball Cock with Rod & Ball Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58489282
AUTHORITY Government Departments
TENDER VALUE 64.94 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Public Health Engineer Organisation
Work Description Tender for Construction Of Ph Section Office Madhiapali And Boundary Wall At Kesherkela Pump House, Balangir
Basic Detail
Tender No ACEPHBGR 03/2026-27
Bidding Type Tender
Location
City Balangir
State Odisha
Key Dates
Publish Date 11 Nov 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 64.94 Lakhs
Tender Fee 10000
EMD 64943
Exemption Available
Document List
BOQ_620037.xls
DTCN.pdf
e6add14c-cba3-46d1-9115-1c8d8307767e.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_620037.xls

pdf

DTCN.pdf

html

e6add14c-cba3-46d1-9115-1c8d8307767e.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender