Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #58488990

Tender For Special Repair To Sailors Married Accommodation (P- 124 And P- 93 ) At installation Mandovi

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
99.20 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
17 days left
EMD
1.73 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Sailors Married Accommodation (P- 124 And P- 93 ) At installation Mandovi

BOQ

Name of Work:- SPECIAL REPAIR TO SAILORS MARRIED ACCOMMODATION (P- 124 AND P- 93 ) AT INS MANDOVI
Sl. No. Item Description
1Demolition of cement concrete for old water proofing treatment of any description and in any position not otherwise specifically provided for any thickness above ground floor including removing debris out side MD land complete all as specified and directed.
2Material and labour for roughening surfaces of old concrete roof/ floor by picking sweeping clean and washing down with water to removing dust etc. complete all as specified and directed.
3Material and labour for brushing neat cement slurry with 3.0 kg of cement per sq meter complete all as specified and directed.
4Material and labour for 40mm thick (average thickness) PCC (1:2:4), type B1, using 20mm graded stone aggregate as leveling course laid to slope as required, finished even & fair without using extra cement. With using water proofing compound 3% by weight (paid separately )complete all as specified and directed.
5Material and labour for rendering 10 mm thick ready mix cement plaster in cement mortar (1:3) on roof slab/ canopies/chajjas with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions and make surfaces to receive water proofing treatment, finished even and smooth without using extra cement complete all as specified and directed. (Note:- water proofing compound will be measured and paid for separately as supply only)
6Supply only integral water proofing compound
7Material and labour for supply and application of 7 layer SHR waterproofing coating system on leaking concrete surfaces by thorough surface preparation, opening of cracks followed by one absorption coat of thermocoal wp51 or equivalent, nano tech modified, uv resistant electroplast clear coat having min 50% solids,filling of crack, then over coating with sandwich coat of electrometric (thermocoal wp51 + cement) waterproofing layer weigh 80 gsm non woven fibre mesh, application of 3 rd coat of elastomeric waterproofing layer having +450% elongation, tensile strength min 2.2 with two cats of thermocoal 0.3c pure acrylic based, uv resistant mpa and then top-coated non-yellowing bio- organism resistant.
8Taking down cement plaster of stone /Pvc block /brick wall / top of chajja, or concrete surface of any description including raking out joints hacking for key securing down with water etc and removal of debris to outside of INS Mandovi Area including filling of open joints in cement mortar 1:6 Complete
9Material and labour for dubbing out with CM 1:4 with ready mix plaster of approved make average 15mm thick on irregular face of walls complete all as specified and directed
10Demolition of brickwork built in cement mortar including disposal of debris, etc outside MD land, complete all as specified and directed.
11Material and labour for cement plaster 20 mm thick in CM 1:4, two coats using factory manufactured pre mix/ready mix having minimum composition of C:S : 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 15 mm thick and finishing coat of 5 mm thick final rendering, including using richer mix for making corners if necessary, including water proofing powder at 3 % of cement at all floors and level, including making grooves of existing size wherever required, including providing chicken wire mesh 100mm x 100mm size at RCC & brick in joints , including cleaning the surfaces, curing etc. complete all as per specifications & as directed by the EIC note: water proofing powder will be measured and paid separately
12Material and labour for rendering 10 mm thick using factory manufactured pre mix/ready mix plaster M/s Ultratech Cement Ltd' or other approved equivalent make, having minimum composition of C:S : 1:6 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over masonry and concrete surfaces, including providing chicken wire mesh 100mm x 100mm size at RCC & brick in joints, including cleaning the surfaces, curing etc. complete all as specified & directed by Engineer-in-Charge
13Material and labour for rendering 5 mm thick on ceiling using factory manufactured pre mix/ready mix plaster of approved equivalent make, having minimum composition of C:S : 1:3 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering in ceiling, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over concrete surfaces, including providing chicken wire mesh 100mm x 100mm size at RCC & brick in joints, including cleaning the surfaces, curing etc. complete all as specified & directed by Engineer-in-Charge .
14Removing plant/growth including its roots up to 1.00m of plant height at any location/at any storey and of any description and treating the surfaces with Acid (HCL) and making good surfaces with cement mortar 1:4, complete all as specified and directed.
15Opening the Separation Cracks at the Junction of RCC and Masonry where ever directed and instructed into‘’V’’Grooves2’’ to 3’’ from the either side of the cracks by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Engineer-in-charge
16Moistening the Cracks, Providing and applying priming/bonding coat of slurry made out of acrylic polymer liquid of approved make in proportion1:1 to surfaces prepared as instructed and directed. Filling the Cracks/Grooves by Providing and applying acrylic polymer liquid of approved make ready mix Polymer modified cement mortar in Proportionof1:5:15 (acrylic polymer liquid of approved make:Cement:Gradedsand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed.
17Providing and applying on new surface of plaster, after preparation of surface by removing dust with water jet spray. Algae to be removed using Bio Block or equivalent. Apply one coat of fiber‑reinforced elastomeric liquid‑applied waterproofing membrane, formulated with selected elastomeric and resilient acrylic polymer with reinforcing synthetic fibers, capable of withstanding up to 7 bar hydrostatic pressure, with a coverage of 3.0-3.50 sqmt/ltr, This shall be followed by two or more coats (40% diluted) of Asian Paints Ultima Suprema or equivalent, 100% acrylic smooth emulsion with silicon additives, rich sheen, resistance to algae growth, excellent DPUR (Dust Pickup Resistance), resistance to dust accumulation, resistance to fading of colors, an acceptable finish as approved by the Engineer‑in‑Charge. The surface must be free from loose paint, dust, or grease before application. The item rate shall be inclusive of all materials, wastage, labor, tools tackles, consumables, scaffolding at any height, etc.Note - Painting to be done by authorised aplicator with adv tools of above make companies
18Providing and applying on old surface including removing of existing paint, after preparation of surface by removing dust with water jet spray. Algae to be removed using Bio Block or equivalent. Apply one coat of fiber‑reinforced elastomeric liquid‑applied waterproofing membrane, formulated with selected elastomeric and resilient acrylic polymer with reinforcing synthetic fibers, capable of withstanding up to 7 bar hydrostatic pressure, with a coverage of 3.0-3.50 sqmt/ltr, This shall be followed by two or more coats (40% diluted) of Asian Paints Ultima Suprema or equivalent, 100% acrylic smooth emulsion with silicon additives, rich sheen, resistance to algae growth, excellent DPUR (Dust Pickup Resistance), resistance to dust accumulation, resistance to fading of colors, an acceptable finish as approved by the Engineer‑in‑Charge.The surface shall be checked for cracks:Cracks up to 3 mm shall be filled with fiber‑reinforced crack filler. Cracks above 3 mm shall be filled with polymer‑modified cement mortar. The surface must be free from loose paint, dust, or grease before application. The item rate shall be inclusive of all materials, wastage, labor, tools tackles, consumables, scaffolding at any height, etc.Note - Painting to be done by authorised aplicator with adv tools of above make companies.
19Material and labour for preparation of newly plastered surfaces of wall preparatory to distempering, Priming plastered and other surfaces with alkali resistant priming paint, Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth & distempering walls with two coats of distemper oil emulsion, white or tinted using smart painting tools as directed by engr in chargeMake: Asian Paints Smart Care Damp Proof Suprema & Ultima Suprema or equivalent.Note - Painting to be done by authorised aplicator with adv tools of above make companies.
20Material and labour for complete removal of existing treatment and preparation of old surfaces of wall and applying two coat of distemper oil emulsion over a coat of primer, Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth using smart painting tools as directed by engr in chargeNote - Painting to be done by authorised aplicator with adv tools of above make companies
21Material and labour for preparation of newly plastered surfaces of ceiling preparatory to distempering, Priming plastered and other surfaces with alkali resistant priming paint, Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth & distempering walls with two coats of distemper oil emulsion, white or tintedNote - Painting to be done by authorised aplicator with adv tools of above make companies
22Material and labour for complete removal of existing treatment and preparation of old surfaces of ceiling and applying two coat of distemper oil emulsion over a coat of primer Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth & completd all as specified and as directed.Note - Painting to be done by authorised aplicator with adv tools of above make companies
23Demolition and breaking up of 100mm PVC pipe
24Demolition and breaking up of 75mm PVC pipe
25Demolition and breaking up of 160mm to 200mm PVC pipe
26Supply and fix PVC (SWR) pipes 160 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors
27Supply and fix PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints, fixed to walls
28Supply and fix PVC (SWR) pipes 75 mm single socketed in any length with rubber ring joints, fixed to walls
29Supply and fix PVC (SWR) bends any radius 110 mm bore with access door
30Supply and fix PVC (SWR) bends any radius 75 mm bore with access door
31Supply and fix PVC (SWR) branch piece, single (single Y) equal or unequal of dia 110mm with access door
32Supply and fix PVC (SWR) branch piece, single (single Y) equal or unequal of dia 75mm with access door
33Supply and fix PVC (SWR) branch piece, double (double Y) equal or unequal of dia 110mm with access door
34Supply and fix PVC (SWR) branch piece, double (double Y) equal or unequal of dia 75mm with access door
35Supply and fix PVC (SWR) vent cowl 75mm dia
36Supply and fix PVC (SWR) vent cowl 110mm dia
37Material and labour for 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement fixed in repairs
38Supply and fix 25 mm CPVC Tank Adaptor
39Supply and fix 50mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors including necessary fittings
40Demolition of cement concrete of any description in any position not otherwise specifically provided for
41Material and labour Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate), 25mm thick on concrete surface over top of RCC chajjas/ wall and plinth protection joint with using waterproofing compound as per manufacture instruction finished even & fair with using extra cement Note: Waterproofing will not be measured separately
42Material and labour for 75mm thick cement concrete (1:3:6) type C2, using 40mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
43Dismantling wrought iron or mild steel work of any description not otherwise provided for etc, complete all as specified and directed.
44Material and labour for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe 410-W (Gde-E- 250) quality-A complete all as specified and as directed..
45Material and labour for preparation of new or previously untreated steel surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
46Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
47Material and labour Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
48RELIEVING STRUCTURAL MEMBERSRelieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately.
49Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades, etc beyond main r/f. (if required in the opinion of the Consultant), carefully with chisel and hammer Providing and applying Rust passivator to existing r/f. bars Including wire brushing of reinforcement , cleaning washing of concrete etc complete as directed. Providing and applying two coats of rust preventer slurry made out of polymeric, elastomeric coating of approved make and cement in proportion 1:1.5 to existing r/f.bars as directed complete. Providing and applying bonding coat of slurry made out of acrylic polymer liquid of approved make as specified in the Brand Names and cement in proportion 1:1 to concrete and r/f substrates complete as directed Providing and applying acrylic polymer liquid of approved make and providing Ready mix Polymer modified cement mortar of minimum M40 grade ) to RCC members Including Hand packing, curing and making the surface rough for plastering.
50Material and labour for chipping & removal of existing damaged, cracked, spalled & loose portion of concrete of the RCC members completely till the reinforcement is exposed and sound concrete (20mm to 50mm) is observed by using mechanical means and manual chisels and further the surface is jetted with clean water for removal of dust and loose particles and complete all as specified and directed. Note : Hard concrete shall not be removed by force.
51Material and labour for cleaning existing reinforcement by sand blasting with suitable pump as directed by the GE and wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of approved make on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
52Material and labour for Anticorrosive Treatment to old and new Reinforcement to Epoxy Zinc Primer of approved make by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed . Note:- Mode of measurement: superficial area of concrete will be measured.
53Material and labour for Epoxy bond coat of approved make over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
54Insertion of corrosion-inhibiting tablet system of approved make suitable to sustained release Corrosion inhibiting caplets which shall protect both anodic & cathodic sites and reduce Corrosion potential Eco; by minimum 80 mV in conductive medium, by drilling 25 mm holes into the concrete at a depth of 30 mm and inserts to be filled by EPOXY SEAL all as directed by Engineer in charge
55Material and labour applying a coat of polymer modified cementious bonding coat on the concrete surface with one coat of styrene butadiene rubber latex emulsion (SBR latex) of approved make with four parts of water and six parts of cement by weight coverage of SBR latex 0.25Ltr/sqm for one coat complete all as specified and directed.
56Supply and fix for wire netting of stainless steel wire 1.4 mm dia (size of mesh 25 mm ) fixed with tinned tacks of stainless steel wire staples, including necessary frame of steel all as specified and directed.
57Material and labour for application of polymer modified reinstatement mortar 20mm thick in isolated places of repair works of RCC members with polymer-modified, cementitious, high-strength repair and reinstatement mortar of approved make having a compressive strength of M40 grade complete all as specified and directed.
58Material and labour for application of polymer modified reinstatement mortar 30mm thick in isolated places of repair works of RCC members with polymer-modified, cementitious, high-strength repair and reinstatement mortar of approved make having a compressive strength of M40 grade complete all as specified and directed.
59Demolition of cement concrete (reinforced) as in roofs, shelves, chajjas, floors ( other than ground floors), beams, staircase, landing, chajjas , parapet, water tank and similar suspended work etc. and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
60Material and labour for TMT bars of Fe-500 D grade conforming to IS: 1786, 10 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
61Material and labour for providing shear connectors and anchoring : Drilling 12mm dia holes upto depth of 100mm and fix 10mm dia TMT bars L shaped anchor rods as shear connectors in defective concrete area of the slab, column, beams etc. or any other structural member as the case may be. Clean the same using water and make sure that there is no fine particle present in the hole. Mix the base and hardener of the polyester resin Fosroc Lokfix or techno commercially equivalent or make as approved by GE with the spatula thoroughly. Fill the drilled and cleaned holes to a minimum depth of 3/4th of the hole with the prepared polyester resin and the reinforced bar shall be inserted to full depth of hole and extra length of the reinforcement bar shall be bent into the concrete to maintain proper cover to the reinforcement. complete all as specified and directed.
62Material and labour for laying cement based Micro-concrete, Rendroc RG 40 of Fosroc make or make as approved by GE, pre-packed single component, chloride free, sulphate free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion of approved quality. Formwork shall be provided for placing micro concrete patch repair as required at site with steel jack system and steel props to support the form work in this application of high strength, dual shrinkage, compensated, micro concrete for placing in nominal thickness of more than 50mm for concrete repair with compresive strength of 40 Mpa at 28 days complete all as specified and directed.Note: The qouted rate deemed to be included for steel formwork / shuttering, if any required.
63Glass Fiber Wrapping System:.Providing & laying applying Glass Fiber sheet wrap of minimum 600 GSM over structural members including.Surface Preparation: Grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete.Profiling: Applying PRIMER on prepared substrate, filling holes and uneven surface with PUTTY etc., complete.Wrapping: Wrapping the Glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., Repeat the same procedure for multiple layer with interval of 8 hours.Sand Pasting: Applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes.(Mode of Measurement: Per Sq.Mt of Fiber consume and not application of surface area.))
64Material and labour Drilling and fixing teflon nozzles in RCC members, including drilling holes (drilling 12 mm dia, 40mm deep holes in structural members at the intervals of 600mm c/c in staggered manner or s directed by Engr-in Charge in RCC structure elements and cleaning the holes (to clean the holes by air blower prior to fixing nozzles) and fixing of nozzles (to insert 12mm dia teflon nozzles in cleaned holes external end of nozzles (to insert 12mm dia teflon nozzles in cleaned holes external end of nozzles to be machined to receive outlet of grouting gun and fixing it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and curing the system for minimum 12 hrs) and cutting of nozzles (to cut the nozzle by chisel after completion of grouting without damaging structural elements etc complete.
65Providing and injection grouting low viscosity (3-5 cps) high molecular weight monomer of approved make into concrete by injection grouting at 150-300 mm centre to centre through nylon nipples of 12 mm dia fixed into drilled holes at 3-5 kg /cm2 pressure and having tensile strength of I 0-15 N/mm2 (ASTM-D-638-95) & flexure of 20-25 N/mm2 (ASTM-D-790- 96). Drilling holes and fixing of nozzles paid separately
66Injecting low viscosity (3-5 cps) high molecular weight by pressure and using mechanized injector gun with accessories, till nozzles refuses to accept the grout, Including, Mixing of materials( Mixing material components (part a & b) in required quantities as per manufacturer’s instruction by weigh batching) and Grouting ( Filling the grouting gun with monomer. Maintain desired pressure in the gun by air compressor; maintain the pressure at exit (4 to 5 Kg/ Cm2) by monitoring pressure gauge at exit. Grouting the material through prefixed nozzles in the structural elements till its refusal. Sealing the nozzle with epoxy putty after the refusal. Monitoring leakages through other nozzles while grouting and seal them as per the requirement. Repeat the process for all the nozzles. the operation to be within pot life of the material.)and Cleaning of gun and accessories ( the gun and accessories like valves, pipes and other fixtures to be cleaned with thinner after the operation to avoid jamming of the gun.) etc. complete.
67Dismantling water tanks and removing to store exe 250 Ltr & n exe 500 Ltr
68Dismantling water tanks and removing to store exe 500 Ltr & n exe 1000 Ltr
69Supply and fix in repair 500 Litre Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
70Supply and fix in repair 1000 Litre Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
71Supply and fix in repair Ball valves 25mm bore dia high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed in repairs . (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm- 690 gms)
72Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
73Material and labour Screed bed or bedding layer of mortar 15 mm thick 1:6 for laying floor finishes
74Material and labour Rendering 10 mm thick cement plaster in cement mortar 1:4 on Vertical Surface
75Glazed ceramic coloured tiles in vertical surface 350 x250x 7 mm/ 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match
76Material and labour Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
77Material and labour Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.48 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
78Material and labour Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.48 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
79Material and labour 25mm to 40mm thick unpolished cuduppah stone slab as in cooking platform below granite stone and like including necessary jointing and pointing and making good to disturbed surface complete all as specified
80Material and labour for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including girding and polishing types.
81Rounding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations,
82Material and labour Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments
83Material and labour for green marble work 18 to 20mm thick (table rubbed and polished) insteps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade
84Taking down steel tubing and connections 15 mm bore
85Taking down steel tubing and connections 20 mm bore
86Supply and fix of CPVC 20mm pipes SDR 11 & Plain CPVC SDR 11 fittings concealed on walls/ceiling or laying in floors complete all as specified.
87Supply and fix of CPVC 25mm pipes SDR 11 & Plain CPVC SDR 11 fittings concealed on walls/ceiling or laying in floors complete all as specified.
88Supply and fix bib taps (long body) , cast copper alloy with crutch or butterfly handle , screwed down , screwed for iron pipe or for brass ferrule & fixed . Size 15mm fixed in repair
89Supply and fix 15 mm size stop valve copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union & fixed in repair
90Supply and fix pillar taps,15 mm bore fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure and fly nut screwed for iron pipes complete fixed in repairs
91Supply and fix angular stop cock with wall flange , cast copper alloy with crutch or butterfly handle , screwed down , screwed for iron pipe or for brass ferrule & fixed . Size 15mm fixed in repair Make Jquar (ARI-CHR-39053) or equivalent model in makes specified in Appx B
92Supply and fix wall mixture with provision for overhead shawer with 115mm long bend pipe on upper side connecting legs & wall flenge , cast copper alloy with crutch or butterfly handle , screwed down , screwed for iron pipe or for brass ferrule & fixed . Size 15mm fixed in repair Make Jquar (CON-CHR-273KNUPR) or equivalent model in makes specified in Appx B
93Supply and fix in repairs Brass chromium plated shower rose 125mm size with Shower arm 15 mm dia size &195mm long with bend of 45degree with flange, including fixing to steel pipe or union.
94Supply and fix Brass Chromium Plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges in repairs
95Supply and fix SS soap dish approximate size 160 x 160 x 90 mm embedded in wall fixed in repair
96Supply and fix in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixing in pipe and position etc complete all as specified.
97Supply and fix 32mm Waste pipe 800mm long in repairs
98Supply and fix 2 way bib taps , cast copper alloy with crutch or butterfly handle , screwed down , screwed for iron pipe or for brass ferrule & fixed . Size 15mm fixed in repair Make Jquar (CON-CHR-041KN) or equivalent model in makes specified in Appx B
99Supply and fix PVC Connection of size 15 mm ,450 mm long with PTMT nuts complete all as specified
100Supply and fix Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) ( excluding flushing cistern and flush pipe ) fixed in repairs
101Supply 10 litres Capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including bracket Supply and fix flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern & fixing High or low level flushing cistern (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, if any
102Supply and fix Wash basins, Vitreous China (flat back or angle back type) 550mmx400mm size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe
103Supply and fix in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen with plug ,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460 mm bowl size 410mm x 330mm x160mm with plugs, washers and wastes; including bedding in cement mortar on to dwarf walls, up to 0.5 sqm each complete all as specified and directed.
104Supply and fix for in repairs Stainless steel plate utensil rack of size 900 X 600 X 1mm thick, 30cm width and fixed to wall surface with necessary bolts complete all as specified
105Supply and fix 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.
106Taking down chowkats or frames not exceeding 1.5 Sqm each but with shutters (without taking off shutters from the frames) all as specified.
107Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4.0 sqm each but with shutters (without taking off shutters from the frames) complete all as specified.
108Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
109Supply and fix Factory made solid fully glazed PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. but wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading. but i.e. glass panes used instead of 5mm wood grain printed PVC sheet panels.
110Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of Frame size 65x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with and including MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge, as per specification & drawing Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
111Supply and fix in repairs MS ordinary rat tail door springs (Capsule type) 300 mm long and including roller and roller plate complete all as specified
112Supply and fix extruded aluminium alloy handles, 125 mm long fabricated type anodised all as specified
113Supply and fix alluminium, anodised, barrel tower bolts of extruded section of size 150 mm long.
114Supply and fix 300 mm long, aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded section & fixing blots & sliding bolts of extruded section or cast aluminium alloy all as specified
115Supply and fix 100 mm long powder coated butt hinges, medium weight, stainless steel all as specified.
116Supply and fix 4 mm thick, sheet glass, ordinary quality and glazing with oil putty / beading in squares not exceeding 0.5 sqm each pane all as specified .
117Supply and fix in repairs 4 mm thick figured glass , pin head type and glazing with oil putty in squares n exe 0.5 sqm in each pane complete all as specified & directed.
118Supply and fix aluminium alloy wire cloth (XPM) 0.45 mm nominal dia of wire & average width of aperture 1.4 mm & fixed with aluminium wire staple.
119Material and labour Preparing new wooden surfaces of any description exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified
120Preparation old painted surfaces of wood and applying one coat of synthetic enamel paint on description not other described over 10cm width or girth
121Supply and fix in repairs 140mm Floor door stopper of aluminium alloy body and tongue, anodised with hard draw steel spring complete all as specified & directed..
122Supply and fix stainless steel premium 06 Pins 'L' types cloth hanger, fixed in repairs.
123Supply and fix MS flat iron for hold fasts etc, all as specified
124Cutting holes in brick walls, exc. half but not exc. one brick wall built in cement mortar for inserting hold fasts and making good dismantled portion in CM 1:3, or cement concrete 1:2:4 type B1 complete all as specified
125Supply and fix aluminum powder coated window/ventilator shutter including frame , any type (sliding or open-able ) with frame , & other similar work etc fabricated by using aluminium section including necessary arrangement to receive 4mm thick sheet glass or wire mesh with aluminium channel beading, stainless steel screws, rollers, maruti lock & F frame including the cost of rubber gasket / rubber beading rollers, maruti lock & F frame etc complete . But the weight of the rubber gasket / beading rollers, maruti lock will not be measured with weight of aluminium shutter Note :- Sheet glass & wire mesh shall be measured & paid separately
126Supply and fix Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineering-charge.
127Supply and fix Curtain rails anodised aluminium alloy with fixing brackets, stops, rollers etc.
128Dismantling of wooden kitchen cabinet and cupboard fixed in any position
129Material and labour for 12 mm thick marine waterproof ply wood grade BWR,(ISI marked and as per IS 710) type BB fixed with screws to timber frame work, block boards, grade 2 quality, interior grade, commercial type , fixed with screws to timber framed work for kitchen cabinet, cupboard etc
130Material and labour for 18 mm thick marine waterproof ply wood grade BWR, type BB (ISI marked and as per IS 710) fixed with screws to timber frame work, block boards, grade 2 quality, interior grade, commercial type , fixed with screws to timber framed work for kitchen cabinet, cupboard
131Material and labour for 0.9 mm thick decorative laminate type I, of surface finish, colour and pattern as approved , fixed with approved adhesive as per manufacturer's instructions.
132Supply and fix for 50 mm size butt brass hinges, heavy weight, type E-11
133Supply and fix for 100 mm long, Brass handles , cast type, polished bright cupboard cabinet etc.
134Supply and fix Ball catches with 8 mm dia steel ball, and brass body and striking plate including letting in and fixed
135Dismantling wrought iron or mild steel work of any description not otherwise provided for
136Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
137Material and labour for 40mm thick cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate finishing cement concrete surface even and smooth without using extra cement all as specified and as directed.
138Material and labour for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces all as specified and as directed.
139Material and labour for broken stone or boulder hardcore of gauge n exc. 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and as directed.
140Material and labour for 100mm thick cement concrete type B- 2, 1:2:4 using 40mm graded stone aggregate finishing cement concrete surface even and smooth without using extra cement all as specified and as directed.
141Mirror polishing on marble/ granite/ kota stone/ stone work where ever required to give high gloss finish and wax finishing complete all as specified and directed
142Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.)(A) Area not exceeding 2.00 sqm each
143Taking down carefully copper/aluminium point wiring complete (light, fan, plug point & power complete along with fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc as specified & directed.
144Material and labour for point wiring complete as specified with 1100 V grade with 1.5 Sq mm single core PVC insulated unsheathed FRLSH cable, copper conductor multistranded passing through including concealed PVC conduit not less than 20 mm dia with concealed modular box suitable for logic modular switches , sockets , etc and logic modular white plates, surroundings of suitable size as required at site with PVC insulated FRLSH unsheathed stranded copper conductor of size 1.5 sq mm as earth wire connected to common earth dully as specified complete all as specified and directed for the following:- Note: - (i) Rate quoted shall include for cost of making GI Metal box and concealed in wall including cutting and sinking of boxes and making good to the walls (ii) Rate include Provision of Inner plates , Cover plates and necessary blank plates as per site requirement
145One light point / one fan point controlled by one, one way switch.
146All as per item No 149 above but for 5 Amp switch socket on the same board.
147All as per item No 149above but for 5 Amp switch socket on independent board.
148All as per item No 149 above but size of cable 4.0 sq mm with earth wire of 4.0 sq mm complete
149All as per item no 149 above but for 2 way point wiring with cable of size1.5 sq mm with 1.5 sq mm earth wire suitable for light points at stair case.( Staircase lights and Bed Lamp).
150Supply and fixing Switch modular type, single pole, one way, 5/6 Amp, one module, completes all as specified and directed.
151Supply and fixing Switch modular type, single pole, one way, and 15/16 Amps, one module complete all as specified.
152Supply and fixing socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, two module, modular type completes all as specified and directed.
153Supply and fixing socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin 5/6 Amp, modular type completes all as specified and directed.
154Supply and fixing Switch modular type, single pole, Bell push, 5/6 Amp, one module, completes all as specified and directed.
155Supply and fixing Switch modular type, single pole, 2 way 5/6 Amp, one module, completes all as specified and directed
156Supply and fix power unit 25 Amps 2 module complete all as specified and as directed by Engineer-in-charge.
157Supply and fixing socket outlet multipurpose 3 pin, 25 Amp modular type completes all as specified and directed.
158S & F modular metal flush box 2 module concealed complete with modular type cover plate 2 module for fixing power unit and sockets complete all as specified and as directed by Engineer-in-charge.
159Supply and fixing in replacement of bell ding dong type AC, 230 volts, single phase complete all as specified and directed.
160Taking down ceiling fans , any type and depositing AGE E/M STORE complete all as specified and directed.
161Supply and fixing ceiling fans Five star rated with brushless direct current motor (BLDC) complete with blades, down rods, modular electronic regulator 5 - Step ,120W 2 Module and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value not less than 6.00 ( Wattage not more than 30 Watt) BEE. Make : Havell's Model Epic Pro BLDC or Equivalent model in makes given in Appx 'B'
162Taking down exhaust fans any type and depositing AGE E/M STORE complete all as specified and directed.(one for Each MD Accn)
163Supply and fix exhaust fan of sweep 300 mm made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding , including making necessary cutting on wall for fixing the exhaust fan and making good to disturbed surfaces complete all as specified and as directed.
164Supply and fixing in replacement of ceiling rose of size 65 x 50 mm surface bakelite 240 Volts three terminal as specified and directed.
165Taking down light fitting any type and wattage complete all as specified and directed.
166Supply and fixing in replacement wall mounting, brushed nickel finish fixture with acrylic diffuser with 9 W LED lamp B22 base fittings complete Make: Havell's Cap Part No. LHFOAJE1TN1I060 or Equivalent model in makes given in Appx 'B'
167Supply and fixing LED lights fitting 1x 20 W, 220V,AC , ultra slim with driver, LED lighting fixture with polycarbonate channel, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
168Supply and fixing LED lights fitting 1x 10 W, 220V,AC , ultra slim with driver, LED lighting fixture with polycarbonate channel, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
169Taking down geyser , any type and depositing MES store yard refix the same after building repair work complete all as specified and directed.
170Supply and fix MCB DB TPN 4 way IP 43 protection ,double door , with acrylic door concealed on wall complete all as specified .
171Supply and fix MCB DB SPN 12 way , IP 43 protection double door with acrylic door concealed on wall complete all as specified
172Supply and fix MCB DB SPN 8 way , IP 43 protection double door with acrylic door concealed on wall complete all as specified
173Supply and fix RCBOs for Earth leakage , over load and short - circuit protection 32 Amp DP 100 mA complete all as specified
174Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning
175Supply and fix MCB 63 Amp 4 Pole ,10 KA complete all as specified and as directed
176Material and labour for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLSH type, cables 4.0 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 4.0 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note :- (i) Three runs of cables drawn in conduit will be measured as one length of sub main. (ii) PVC conduit and its accessories is deem to be included in this item rates.(iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
177All as per item No. 181 above but with single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLS type, cables 6.0 Sqmm including two 6.0 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire complete .
178Material and Labour in replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0 mm thickness buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and including galvanised earth lead wire of 25 X 4 MM strip as earth lead dia by means of nuts & bolts, check nuts and washers of galvanised including PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm, excavation and earth work in any type of soil, charcoal dust, salt, medium grade GI watering pipe 20 mm dia with funnel and wire -mesh and light grade GI protection pipe of 40 mm bore from top edge of earth plate up to main distribution board complete all to as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion.
179Supply and fix LED Skirting light with white LED-3 module with necessary modular type frame and cover plate on wall complete all as directed. Make Legrand Cat part no - 6759 76 Equivalent model in Makes given in Appx 'B'
180Supply and fix in LED type wall light /Reading light 2 Watt fix on bed side wall complete include in all as directed. ( Note: 01 Per Each DU)Make Legrand Cat part no - 6730 36 Equivalent model in Makes given in Appx 'B'
181Material and labour for taking down single phase electric energy meter any type and Refixing complete all as specified and directed.
182Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66protection, with impact and corrosion resistant complete with driver and lamp Including taking down old fittings
183All as per item No.181 but with 1.5 SQ MM copper conductor in PVC conduit surface type complete all as specified. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58488990
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 99.20 Lakhs
LAST DATE 09-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Sailors Married Accommodation (P- 124 And P- 93 ) At installation Mandovi
Basic Detail
Tender No 86142
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 11 Nov 2026
Submission Date 09 Dec 2026
Open Date 11 Dec 2026
Finance
Tender Value 99.20 Lakhs
Tender Fee 1000
EMD 1.73 Lakhs
Exemption Available
Document List
86142Tender.pdf
BOQ_895398.xls
c08d2a5c-0b3f-4cae-a921-72d0c8bf1896.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Dec 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

86142Tender.pdf

xls

BOQ_895398.xls

html

c08d2a5c-0b3f-4cae-a921-72d0c8bf1896.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender