Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #58488965

Tender For Repair And Maintenance Of Internal Electric Wiring, Fittings And Fictures, Led Light, Earthings Etc, External Electric Supply, Summer And Cooling Appliances And External Water Supply And Connected Work At Mayabunder Under Ge(S) Diglipur.

Issued by Statutory Bodies & Commissions/Committees · North and Middle Andaman, Andaman And Nicobar Islands
Tender Value
13 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
13 days left
EMD
26000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
North and Middle Andaman → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Internal Electric Wiring, Fittings And Fictures, Led Light, Earthings Etc, External Electric Supply, Summer And Cooling Appliances And External Water Supply And Connected Work At Mayabunder Under Ge(S) Diglipur.

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF INTERNAL ELECTRIC WIRING, FITTINGS AND FICTURES, LED LIGHT, EARTHINGS ETC, EXTERNAL ELECTRIC SUPPLY, SUMMER AND COOLING APPLIANCES AND EXTERNAL WATER SUPPLY AND CONNECTED WORK AT MAYABUNDER UNDER GE(S) DIGLIPUR.
Sl. No. Item Description
1INTERNAL ELECTRIFICATIONTaking down carefully at any description in any position for old unserviceable point wiring for one light, socket or power etc including all fittings such as switches sockets, holders, light fittings, fan regulators etc and making good the disturbed surface of wall / ceiling complete all as specified and as directed.
2M&L for Point wiring One light point controlled by one way switch 5/6 Amps. with casing and capping controlled by one switch with 1.50 Sqmm (nominal area) FRLSH, PVC insulated 1100 volts grade multi stranded copper conductor single core unearthed cable and FRLSH, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, with all fittings, ISI marked and accessories, the pipe shall be fixed with clamping and saddle including provision of mild steel terminal boxes/ Sunken boxes of suitable size made with 1.6 mm thick mild steel sheet recessed in wall with a coat of black bituminous paint and providing of with 3mm thick Bakelite/PVC sheet ISI marked top cover, suitable for fixing of switches/ sockets/ regulators etc fixed in recess of wall with brass chromium plated screws and cap washer complete all as specified and as directed
3Ditto As per item No. 2 above, but for One ceiling fan/ Exhaust fan point controlled by one way switch 5/ 6 Amps.
4Ditto As per item No. 2 above, but for One socket out let 5/ 6 Amps point on the independent board.
5Ditto As per item No. 2 above, but for wiring with 2.50 Sqmm single core copper conductor for one socket out let 15/16 Amps point on the independent board complete all as specified and as directed.
6S&F for switch socket combination 2 in 1, 5 Pin, 5/ 6 Amps, white ivory finish flush type complete all as specified and as directed.
7S&F for switch socket combination outlet 2 in 1, 5 Pin 6/ 16 Amps multipurpose 230 Volt flush type complete all as specified and as directed.
8S&F for switch piano flush type 5/ 6 Amps single pole one way complete all as specified and as directed.
9S&F for switch piano flush type 15/ 16 Amps single pole one way complete all as specified and as directed.
10S&F for stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
11S&F for ceiling rose, bakelite, surface type, 220/ 240 Volts, three terminals complete all as specified and directed.
12S&F for lamp holder, insulated body, with back plate suitable for batten/ angle fittings complete all as specified and as directed.
13S&F for Modular switch, one way, 6 amps, 1 module 230 v complete all as specified and as directed.
14S&F for modular metal flush box, 3 module complete all as specified and as directed.
15S&F for modular metal flush box, 6 module complete all as specified and as directed.
16S&F for modular type fan regulator 120w ,two module, 230 v complete all as specified and as directed.
17S&F for modular switch socket combination outlet 2 in 1, 5 Pin 16 Amps multipurpose 230 Volt flush type complete all as specified and as directed.
18S&F for modular switch socket combination 2 in 1, 3 Pin, 6 Amps, white ivory finish flush type complete all as specified and as directed.
19M&L for Modular white cover plate with frame 3 module complete all as specified and as directed.
20M&L Modular white cover plate with frame 6 module complete all as specified and as directed.
21Taking down at any description in any position for sub main wiring of any type complete all as specified and as directed.
22M&L for sub main wiring for AC with 3 run of 4.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. Note: Three run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
23M&L for sub main wiring for AC with 3 run of 6.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. Note : Three run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
24Supply and laying DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 63mm and inner dia 50mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed.
25S&F for LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 139 x 119 x 70 mm (internal dimensions) comprising 2 Nos aluminium busbar of adequate capacity including suitable size MS clamps all as directed, including taking down old unserviceable junction box complete all as specified and as directed.
26S&F in replacement LED type security light fitting 1 x 25 watts pressure die cast housing with aerodynamically shaped body, high grade powder coating finish, good aesthetics and corrosive protection toughened glass & high power LEDs protection inlcuding mounting arrangements like bracket made out of galvanized iron tubing 'light grades' of suitable dia of pipe up to a length of 1.5m bent to shape fixed to wall with mild steel flat iron clamps 40 x 5mm duty painted and connecting with 1.5 Sqmm three core weather proof PVC cable copper conductor multistranded from terminal point to fitting including old unserviceable security light complete all as specified and as directed.
27S&F in repair/replacement post top lantern fitting LED type of size 1x10 Watts with IP 65 protection, Resistant to impact and corrosion, moon light effect and eficient light distribution including taking down old unserviceable post top lantern complete all as specified and directed.
28S&F for sheet metal enclosure for 4 way distribution boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with blanking plates including Taking down at any description in any position for old existing Distribution Boxes all as specified and as directed.
29S&F for sheet metal enclosure for 8 way distribution boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and blanking plates including Taking down at any description in any position for old existing Distribution Boxes all as specified and as directed.
30S&F sheet metal enclosure for 4 way distribution boards (DB’s), double door, triple pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with blanking plates including Taking down at any description in any position for old existing Distribution Boxes all as specified and as directed.
31S&F MCB, single pole 6 Amps to 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete all as specified and as directed.
32S&F MCB, single pole and neutral 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete all as specified and as directed.
33S&F in replacement MCB in feeder piller boxes, single pole and neutral 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete all as specified and as directed.
34S&F MCB, single pole and neutral 40 Amps to 63 Amps, 240 Volts, ‘C’ curve, 10 kA all complete all as specified and as directed.
35S&F MCB TPN 16 Amps to 32 Amps, 415 Volt, 10 kA, 'C' Curve rating, complete all as specified and as directed.
36S&F MCB TPN 40 Amps to 100 Amps, 415 Volt, 10 kA, 'C' Curve rating, complete all as specified and as directed.
37S&F energy efficient surface and wall mounted LED batten 20 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed.
38S&F energy efficient surface and wall mounted LED batten 2 feet, 9/ 10 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed.
39S&F energy efficient 2 feet x 2 feet LED light fitting 36 Watts with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old light fitting complete all as specified and as directed.
40Taking down at any description in any position for old unseviceabe ceiling fan and deposit it in MES store complete all as specified and as directed.
41S&F for ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed at site.Note : Old unsv ceiling fan will be deposited to MES store yard
42Taking down the ceiling fan of any sweep of any make by disconnecting electric connection from ceiling rose, for carrying out necessary repair such as replacement of old condensers/ rubber bushes/ bearing/ flexible copper cable of suitable size including overhauling by carrying out repair such as applying grease to metal parts and replacement of suitable size of cotter/split pin as required, reassembling and re-fixing in original position, commissioning, testing complete all as specified and as directed.Note:- Rate deemed to be inclusive of new flexible copper wire between ceiling rose to fan connector no extra claim what so ever will be entrained by the department.
43S&F in following parts/ components of ceiling fan existing make and size complete all as specified and as directed.Note: Parts and components supplied under this item shall be fixed under items herein before:-Supply only Gun metal bush bearing
44Supply only ball bearing.
45Supply only capacitor 2.5 MFD.
46S&F in replacement of louvers suitable for 300 mm sweep exhaust fan made out of GI sheet 1.2 mm thick and 0.45 mm thick louvers flap including mosquito wire net complete all as specified and as directed.
47M&L for rewinding of coils of exhaust fan of sweep 250 mm to 450 mm of any make by following ways:- (i) Taking out complete coils from the rotor of exhaust fan (ii) Rewinding of exhaust fans of sweep 250mm to 450mm by using super enameled copper wire and turns as per existing gauge and approved quality including insulation paper, varnishing, drying and refitting the exhaust fan and testing the speed complete all as specified and as directed.
48Supply only following parts / components of exhaust fan of existing make and size complete all as specified and as directed :- Supply only Gun metal bush bearing
49Supply only ball bearing.
50Supply only capacitor 4 MFD.
51M&L for painting of ceiling fans in situ with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning dust etc complete all as specified and as directed.
52M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (each pit not less than 2.25 mtr below ground level) with Top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of galvanised earth strip 25x4 mm connected by means of bolts, nuts, check nuts and washers of galvanised iron steel, provision of 40mm dia GI pipes medium grade for earth wire protection connected from earth plate electrode to main switch board, provision of 15 mm dia GI pipe perforated medium grade for watering arrangement and PCC (1:3:6) type-C1 chamber, MS funnel, wire mesh, 50 mm thick RCC (1:2:4) type-B1 for earth pit. Cover with 6 No's 8 mm dia high strength deformed steel TMT bars on both ways, including test terminal block made of gun metal or phosphorous bronze 75x75x25 mm and drilled and screwed including 3 nos 8 mm dia, 25 mm long at hex head screw also necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance not exceeding 50 mtr, provision of char coal and salt as shown in electrical plate No. 3 of schedule Part-I 2009 all as specified, directed and Testing on completion, including taking down old unserviceable earthing complete all as specified and as directed.
53EXTERNAL ELECTRIC SUPPLY/ WATER SUPPLYExcavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep and getting it out in soft/loose soil including forming bottom surface to required level for laying pipes/ cables and water pipe lines complete all as specified and as directed.
54Returning, filling in excavated soil including spreading, leveling, watering, well ramming in layers not exceeding 25cm complete all as specified and as directed.
55Removing the surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above starting point complete all as specified and as directed.
56Supply, laying and testing XLPE insulated, armourd heavy duty electrical cable with aluminium conductor, 1100 Volts grade size area 25 Sqmm 3.5 core includind disconnecting and taking down of existing complete all as specified and as directed.Note : Earthwork and other connected items like DWC/GI Pipe measured and paid separately
57ditto all as per item No 51 above but cable size 10 Sqmm 4 core ditto
58ditto all as per item No 51 above but cable size 16 Sqmm 4 core ditto
59ditto all as per item No 51 above but cable size 35 Sqmm 3.5 core ditto
60ditto all as per item No 51 above but cable size 50 Sqmm 3.5 core ditto
61ditto all as per item No 51 above but cable size 95 Sqmm 3.5 core ditto
62ditto all as per item No 51 above but cable size 240 Sqmm 3.5 core ditto
63Supply and laying DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 120mm and inner dia 103mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed.
64ditto all as per item No 51 above but of outer dia 63mm and inner dia 50mm with smooth internal
65ditto all as per item No 51 above but of outer dia 50mm and inner dia 38mm with smooth internal
66S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 16 to 35 Sqmm, indoor/ outdoor type all as specified and as directed.
67S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 50 to 95 Sqmm, outdoor type all as specified and as directed.
68S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 240 Sqmm, outdoor type all as specified and as directed.
69M&L for painting of street light poles, by removing of old paint and applying one coat of red oxide metal primer and two coats of approved aluminium paint on steel tubular swaged pole, cross arms and service brackets complete all as specified and as directed.
70M&L for painting of RCC pole by two coats of cement based paint as per approved pattern complete all as specified and as directed.
71Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old u/s light fitting complete all as specified and as directed.
72Ditto as per item No. 58 above, but 90 Watt ditto
73S&F medium grade GI pipe bracket 40mm bore of length not less than 1.20m, bent to shape and fixed to poles/ wall with two No MS flat clamps etc. duly painted with two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed
74S&F for LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp taking down old u/s light fitting complete all as specified and as directed.
75Ditto as per item No. 61 above, but 170 Watt ditto
76S&F LED bollard light fitting 1x14 Watts with IP 65 protection of neutral white colour in die-cast housing and Polycarbonate diffuser cover on base plate mounting with operating voltage 140-270 V, AC, 50 Hz, complete all as specified and as directed.
77Taking down at any description in any position for the LED street/ flood lights/ bollard lights of any type/ size from its existing position, replacing new driver and refixing the light fitting in its original position complete all as specified and as directed.
78S&F LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 139 x 119 x 70 mm (internal dimensions) comprising 2 Nos aluminium busbar of adequate capacity including suitable size MS clamps, including taking down old unserviceable junction box complete all as specified and as directed.
79S&F MCB 4 Pole, 415 Volt, 32 Amp with breaking capacity 10 kA, rating with thermal magnetic protection unit complete all as specified and as directed.
80S&F MCCB 4 Pole, 415 Volt, 63 Amp with breaking capacity 16 kA, rating with thermal magnetic protection unit complete all as specified and as directed.
81S&F MCCB 4 Pole, 415 Volt, 100 Amp with breaking capacity 16 kA, rating with thermal magnetic protection unit complete all as specified and as directed.
82M&L for wiring with 1100 Volt grade, 2 runs of 1.5 Sqmm single core FRLSH PVC insulated unsheathed multi stranded copper conductor cable drawn through rigid PVC conduit from street light in box/ looping box to street light fitting along with 1.5 Sqmm single core FRLSH PVC multi stranded copper conductor cable green in colour as continuous earth wire complete all as specified and as directed.
83M&L for painting of LT panel of any type (indoor/ outdoor) by removing of old paint and applying one coat of red oxide metal primer and two coats of approved synthetic enamel paint to LT panel complete all as specified and directed.
84M&L for PCC (1:2:4), type-B1 (using 20 mm graded crushed granite stone aggregate) as in coping complete all as specified and as directed.
85Cutting through existing bituminous road /PCC/floor/approx size width 20cm X 30cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and as directed.
86COOLING APPLIANCESM&L for taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/ N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R 134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 40/80 Ltrs capacity water coolers complete all as specified and as directed.
87M&L for cleaning including cleaning the system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vacumising, charging of R-12/R-22 gas, replacement of copper pipe, copper strainer, topping up compressor oil, testing & commissioning the water coolers of capacity 40/80 Ltrs complete all as specified and as directed.
88S&F in repairs relay assembly suitable for water cooler of any capacity as per existing complete all as specified and as directed.
89S&F in repairs thermostatic switch suitable for water cooler of any capacity as per existing complete all as specified and as directed.
90S&F in repairs capacitor suitable for water cooler of any capacity as per existing complete all as specified and as directed.
91S&F in repairs overload protector suitable for water cooler of any capacity as per existing complete all as specified and as directed.
92S&F in repairs fan motor with fibre blade suitable for water cooler of any capacity complete all as specified and as directed.
93S&F in repairs PVC hose connections, for water out let pipes including fixing by proper clips complete all as specified and as directed.
94S&F in repairs PVC float valve of 15mm bore (including ball) suitable for water cooler of any capacity as per existing complete all as specified and as directed.
95S&F in repairs capillary tube including brazing for water cooler of any capacity complete all as specified and as directed.
96S&F in repairs wiring kit for water cooler of any capacity complete all as specified and as directed.
97S&F in repair chromium plated water tray basin for water cooler of any capacity matching to the existing complete all as specified and as directed.
98M&L for preparation of old painted surfaces of water cooler including repairing the dented surface by applying putty and removing old paint cleaning and applying by spraying two coats of synthetic enamel paint of approved colour, writting the SM /Ser No / unit name and date of repair of machine complete all as specified and as directed.Note:- Colour code shall be approved by Engineer-in-Charge.
99REFRIGIRATORSM&L for taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 165 ltrs capacity complete all as specified and as directed.
100M&L for gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil, including to and fro transportation of the unit to the work shop testing & commissioning the refrigerators of capacity 165 to 210 Ltrs complete all as specified and as directed.
101S&F in repairs relay suitable for Refrigerator / deep freezer of any capacity as per existing model complete all as specified and as directed.
102S&F in repairs overload protector suitable for refrigerator / deep freezer of any capacity as per existing model complete all as specified and as directed.
103S&F in repairs thermostatic switch of auto de-frost suitable for refrigerator any type and capacity and any model complete all as specified and as directed.
104AC & REFRIGIRATIONM&L for taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 165 ltrs capacity complete all as specified and as directed.
105M&L for taking down the AC unit of any capacity by disconnecting all electrical and piping connections and performing following maintenance tasks:-(a) Removal of dust from the outer body with the help of a blower.(b) Cleaning the condenser coils with water and cleaning agent/soap solution and decaling it.(c) Painting the base tray with one coat of black enameled paint.(d) Cleaning of air filter of with vacuum cleaner or washing the filter in lukewarm water with detergent.(e) Cleaning of anti allergy and triple filter and drying the filter in direct sunlight for 2 hrs.(f) Cleaning of plasma filter with vacuum cleaner or washing the filter in lukewarm water with detergent and drying the filter in shade.(g) Cleaning of micro protection filter with vacuum cleaner only.(h) Cleaning of indoor unit with a soft, dry cotton cloth.(i) Checking all connections including functioning of relays, capacitors, overload protectors, thermostats, industrial socket (Metal clad) and circuit breaker.(j) Refixing all items and making it serviceable.Note: All new parts shall be measured and paid separately.
106M&L for taking down the AC unit of any capacity (both indoor & outdoor units) by disconnecting electrical connections and piping, shifting to new location and reinstalling with necessary additions/ alterations, fittings and fixtures, making good the disturbed surfaces complete all as specified and as directed.
107S&F for copper pipe line heavy duty upto 5/8\\" dia with puff insulation and flair nuts from indoor to outdoor split type AC of 1.5/2 TR capacity complete all as specified and as directed.
108S&F in repairs of capacitor (conforming to IS:2993-1975) AC 230 Volts in plastic container 45/4.0 mfd complete all as specified and as directed.
109S&F in repairs of capacitor (conforming to IS:2993-1975) AC 230 Volts in plastic container 55/6.0 mfd complete all as specified and as directed.
110S&F in repairs condenser unit complete set suitable for 1.50 Ton split type AC unit including removing the existing unit complete all as specified and as directed.
111S&F in repairs fan blade suitable for 1.50 Ton split AC complete all as specified and as directed.
112S&F in repairs blower motor capacitor complete all as specified and as directed.
113S&F in repairs remote with holder suitable for split type ACs complete all as specified and as directed.
114S&F in repairs swing motor as per existing model/ make for split type AC 1.5/ 2 TR complete all as specified and as directed.
115M&L for disconnecting and taking down burnt compressor of capacity 1.5/2 TR from split AC unit and supply and install the new compressor 1.5/2 TR capacity duly filled with gas as per existing model and size and testing also complete all as specified and as directed.Note:- (1) Guarantee card with original purchase voucher of the original manufacturer shall be produced before payment. (2) Freon Gas measured and paid separately under the relevant item of sch 'A' all as specified and directed.
116S&F in repairs PCB Board suitable for 1.5/2 Ton split AC complete all as specified and as directed.
117Supply and charging of refrigerant gas R-22/ R134A/ R32 in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed.
118M&L for repair of voltage stabilizer of 4 KVA of any type including replacement of spare parts such as transformer, PCB, diode, condenser, preset IC, volt meter, ammeter, indicator lamp, socket outlet and any other parts as required for proper functioning of stabilizer complete along with testing and transportation charges from site to workshop, complete all as specified and as directed.
119Ditto all as per item No. 105 here-in-before but capacity 5 KVA ditto
120M&L for repairing of leakage of GI tube size from 80 mm bore dia at any location and any position by cutting/ threading/ jointing and including earth work, GI fittings such as tee/ socket/ elbow/ reducer/ nipple or as site requirement complete all as specified and as directed.
121M&L for repairing of leakage of GI tube size from 32 mm bore to 50 mm bore dia at any location and any position by cutting/ threading/ jointing and including earth work, GI fittings such as tee/ socket/ elbow/ reducer/ nipple or as site requirement complete all as specified and as directed.
122M&L for repairing of leakage of GI tube size from 20 mm bore to 25 mm bore dia at any location and any position by cutting/ threading/ jointing and including earth work etc, GI fittings such as tee/ socket/ elbow/ reducer/ nipple or as site requirement complete all as specified and as directed.
123Taking up or down old CI/DI tubing of 80 mm bore dia and connections including cleaning for refixng (serviceable) or removal to store complete all as specified and as directed. Note:- Excavation and earthwork measured and paid separately.
124Taking up or down old GI/DI/PPR tubing of 40 mm bore dia and connections including cleaning for refixng (serviceable) or removal to store complete all as specified and as directed. Note:- Excavation and earthwork measured and paid separately.
125Ditto all as per ser item No 111 (here-in- before) above but bore of Pipe 25 mm ditto
126Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) of size 25 mm dia bore complete all as specified and as directed.
127Ditto all as per item no 113 above but size of 40 mm dia bore ditto
128M&L for laying DI pipe with spigot and socketed ends, class K-9 in any length all as per IS 8329/2000 with blue epoxy coated with suitable rubber tyton joint complete for 80mm dia pipe complete all as specified and as directed.
129S&F 3-layer PP-R (Polypropylene random copolymer) of 40mm bore concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
130S&F 3-layer PP-R (Polypropylene random copolymer) of 25 mm bore concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
131S&F for 40 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground complete all as specified and as directed.
132S&F in repair Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable globe valve or gate valve of following size 25 mm bore dia complete all as specified and as directed.
133Ditto all as per item no 119 above but size of 40 mm bore dia ditto
134S&F in repairs PP-R Gate valves (brass insert) of following size 25 mm bore dia outer dia of pipe all as specified and directed.
135Ditto all as per item no 121 above but size of 40 mm bore dia ditto
136M&L for repairing of 80 mm dia sluice valve by opening for rectifying leakage, refacing, regrinding, replacement of galand packing, gasket, nut, bolt, washer, wheel and refixing in its original position after testing complete all as specified and as directed.
137S&F in repair PP-R Ball valves (brass insert) of 25mm outer dia of pipes as per requirement of the site complete all as specified and as directed.
138S&F Brass Float valve 25 mm for pipe fitting with synthetic rubber washer suppied with brass rod, full flow design ISI mark complete all as specified and as directed.
139M&L for cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes of tank capacity 500 ltrs complete all as specified and as directed.
140M&L for cleaning of over head water storage tank capacity not exceeding 25,000 ltrs by removing mud, silt, cutting of grass, roots and pumping out waste water, scrapping with wire brush, spreading bleaching powder, drying of tank and refilling fresh water including repairs to the opening door complete all as directed and as directed.
141M&L for cleaning of semi underground water storage sump of capacity not exceeding 20,000 ltrs by removing mud, silt, cutting of grass, roots and pumping out waste water, scrapping with wire brush, spreading bleaching powder, drying of tank and refilling fresh water including repairs to the opening door and outside painting to semi UG sump as per existing colour scheme complete all as directed and as directed. Please Enable Macros to View BoQ information
142M&L for cleaning of semi underground water storage sump of capacity not exceeding 20,000 ltrs by removing mud, silt, cutting of grass, roots and pumping out waste water, scrapping with wire brush, spreading bleaching powder, drying of tank and refilling fresh water including repairs to the opening door and outside painting to semi UG sump as per existing colour scheme complete all as directed and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58488965
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Internal Electric Wiring, Fittings And Fictures, Led Light, Earthings Etc, External Electric Supply, Summer And Cooling Appliances And External Water Supply And Connected Work At Mayabunder Under Ge(S) Diglipur.
Basic Detail
Tender No 8244/E8
Bidding Type Tender
Location
City North and Middle Andaman
State Andaman And Nicobar Islands
Key Dates
Publish Date 11 Nov 2026
Submission Date 04 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 13 Lakhs
Tender Fee 500
EMD 26000
Exemption Available
Document List
35bcd479-01be-4057-81d9-7233a141a7e9.html
8244TENDER.pdf
BOQ_895499.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

35bcd479-01be-4057-81d9-7233a141a7e9.html

pdf

8244TENDER.pdf

xls

BOQ_895499.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender