Tender For special Repair/ Replacement Of Lt Ug Cable Of Street Lights At Post No 28 To 03 Under Ge Gurdaspur.
Tender Value
27 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
12 days left
EMD
54000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurdaspur → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair/ Replacement Of Lt Ug Cable Of Street Lights At Post No 28 To 03 Under Ge Gurdaspur.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling ACSR conductor of any size, channels, angle iron, clamps, nut, bolts, stay wire, stay assembly, GI wire, anti climbing devices etc complete all as specified and directed by Engineer-in-Charge. |
| 2 | Taking down any type insulator complete all as specified and directed by Engineer-in-Charge. |
| 3 | Taking down PCC pole 9 meters long complete all as specified and directed. |
| 4 | Taking down aerial bundled cable 35sqmm + 25 sqmm, LT UG cable including GI tubing and bricks complete all as specified and directed by Engineer-in-Charge. |
| 5 | Taking down any type of LT UG cable including GI tubing and bricks complete all as specified and directed by Engineer-in-Charge. |
| 6 | Excavation in trenches in soft/ loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out complete all as specified and directed. |
| 7 | Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 8 | Returning, filling in, including spreading, leveling,watering and well ramming in layers n.exc 25 cm thick in soft loose soil all as specified. |
| 9 | Supply and laying brick common burnt sub class 'B' old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable complete all as specified and directed. |
| 10 | M&L for sand cushioning in trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed. |
| 11 | S&F in repair for cable protection GI tubing light grade fixed along the pole/ wall/ under road of size 80 mm bore with necessary clamps, nut and bolts all as specified and directed by Engineer -in- Charge. (Note :- Clamps, nut and bolt will be measured and paid separately). |
| 12 | S&F in repair for cable protection GI tubing light grade fixed along the pole/ wall/ under road of size 40 mm bore with necessary clamps, nut and bolts all as specified and directed by Engineer -in- Charge. (Note :- Clamps, nut and bolt will be measured and paid separately). |
| 13 | Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor 16 Sqmm 4 core complete all as specified and directed. |
| 14 | Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor 25 Sqmm 4 core complete all as specified and directed. |
| 15 | Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor 150 Sqmm 3.5 core complete all as specified and directed. |
| 16 | Supply, installing, testing and commissioning factory made (CPRI Approved) outdoor type dust and vermin proof LT panel board cubical double door hinged type compartmentlised of suitable size 415 volt, AC 50 Hz fabricated of CRCA sheet 3.15mm thick machine pressed and angle iron frame 40mm x 40mm x 6mm grouted in PCC block of size 200 x 200 x 300mm made of 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) and powder coated inside and outside complete including 4 pole aluminium bus bar of capacity 500 amps mounted on porcelain insulators and enclosed in chamber and connection from incoming and outgoing electric cable with suitable size thimbles/ lugs with openable shutters on both side comprising of following:-(i) MCCB 200 Amp 35KA repturing capacity 4 pole with adjustable thermal release - 01 No outgoing. (ICU = 100% ICU). (ii) Busbar chamber of 315 Amp capacity bus bar for in and out of the LT cables (minimum four cable in/ out provision to be provided). (iii) Digital volt meter 0-500 volt with selector switch, digital amp meter of capacity 0-250 Amp alongwith selector switches 3 x LED type indicator (RYB) 3 x 300/ 5 tape wound CT's 3 x SP MCBs of 6 Amp for protection of indicator - 01 No. |
| 17 | S&F junction box poly corbonate with glass fibre reinforced, environment friendly, recylable, UV resistant, halogen and silicon free anti acid and anti corrosive IP 66/67 in accordance with IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar and din rail for fixing the MCB including one No MCB SP 6A 10KA to control the street light with necessary clamps, nuts bolts to fix the junction box with poles complete all as specified and directed. |
| 18 | A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Rs. 95,200/- Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender