Housing Urban and Rular Development Government Departments Closing in 0 days TDR #58488182

Tender For Construction Of Additional Multistory/Multipurpose Auction Phar/Platform At F&V Market Zazna Ganderbal.

Issued by Government Departments · Ganderbal, Jammu and Kashmir
Tender Value
2.54 Crore
Estimated cost
Bid Submission
19 Nov 2026
0 days left
EMD
5.09 Lakhs
Bank guarantee accepted
Document Fee
5500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganderbal → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Additional Multistory/Multipurpose Auction Phar/Platform At F&V Market Zazna Ganderbal.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Nov-2026 Time of completion Other 17-Nov-2026
2 12-Nov-2026 Time of completion Other 19-Nov-2026
3 16-Nov-2026 extension in date Date 19-Nov-2026

BOQ

Name of Work:- Construction of Additional Multistory/Multipurpose Auction Phar/Platform at F&V Market Zazna Ganderbal.
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil complete.
2P/L, of dry stone soling duly hand packed for foundation ,footings, floors etc with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete.
3Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete.
4Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) all complete.
5Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) all complete.
6Supply & laying of GSB under floors in trenches, plinth, sides of foundations etc consolidating each layer by ramming ,watering, compacting, all inclusive leads, lifts, loading, un-loading, cost and carriage of material all complete.
7Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete
8Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) all complete.
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns etc for mass concrete.
11Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts.
12Centering and shuttering including strutting, propping etc. and removal of form for: Stairs (excluding landings) except spiral staircases.
13Centering and shuttering of including strutting, propping etc. and removal of form work for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.
14Centering and shuttering of including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platforms.
15Centering and shuttering including strutting, propping etc. and removal of form work for: Edges of slabs and breaks in floors and walls etc complete
16Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6( 1 cement : 6 coarse sand) incl. Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level all complete.
17Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate all complete.
18Providing wood work in frames of doors, windows,clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood.
19Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately) 12 mm thick pre-laminated particle board (decorative lamination on one side and other side balancing lamination) grade-I, medium density flat pressed three layer particle board FPT-I or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848 and pre laminated conforming to IS: 12823, Grade-I, Type-II marked .
20Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick incl. 4mm thick glass panes (weighing not less than 10kg/sqm).
21Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : First class kail wood
22Providing and fixing of Heavy duty glass panes 3.5mm thick instead of oridinary glass panes 13.75 kg/sqm in doors, windows and clerestory window shutters (Area of opening for glass panes exclud. Portion inside shall be measured incl. all necessary beadings, fittings/fixtures etc complete.
23Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete Welded all complete.
24Providing and fixing of high Rib colour coated sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick incl. Ridges, hips, Valleys etc all complete.
2512mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 coarse sand) all complete.
26Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick all complete.
27Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm
28Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)all complete.
29Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work all complete.
30P/F of heavy duty Hardware iteams of approvewd brand and make including necessary fittings/fixtures complete:-: Tower Bolts 150mm
31Tower Bolts 100mm
32Handle 100mm
33L-Drops
34Handles 200mm
35I-Hooks
36Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm.
37Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer incl. paint etc all complete. as per the directions of EIC incl. all carriages etc complete.
38Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix) all complete.
39Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar all complete.
40Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead.
41Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm all complete.
42Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank all complete.
43Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc PN-16 pipe , 20mm OD(SDR-7.4)
44PN-16 pipe , 25mm OD(SDR-7.4)
45PN-16 pipe , 32mm OD(SDR-7.4)
4620mm Elbow, T-Socket, Crossover
4720mm Male and Female Adopter.
4825mm Elbow , T-Socket, Crossover
4925mm Male and Female Adopter.
5032mm Elbow, T-Socket, Crossover
5132mm Male and Female Adopter.
52Tanky Nipple/Connector
53PPR Ball Valve
54Brass Float Value
55P/F of 1 HP centrifugal self priming pump of approved quality crompton Greaves/Kilosker or equivalent (Heavy Duty) incl. all fittings/ fixtures/ fixing/ wiring charges all complete.
56Providing and fixing scaffolding system of bamboo sticks on the exterior side of building/structure, upto 25 mtrs height above ground level, incl. additional rows of scaffolding in stepped manner as per requirement of site, and maintaining it in a serviceable condition of execution of work of cleaning and/or pointing and /or applying chemical and removing in their after the scaffolding system shall be stiffened with bracings, runners connecting with the building etc where ever required. If feasible, for inspection of work at required location with essential safety features for the work men etc complee as per directions and approval of EIC.
57Carriage of Material :- Aggregate/Sand for an avg lead of 15 Kms
58Bricks for avg. lead of 15 Kms.
59Electrification Part A (AVR, Panel & Cabling)
60Supply,Installation,Testing & Commissioning of Buck-Boost type 125 KVA,3-Phase,415V,L.T,Unbalanced Servo voltage stabilizer that must take a load of 125KVA at the Following Specifications No. of Phases = 3 No. ,Input Voltage (L-L)= 242-460 Volts,Output Voltage =415 volts ±1%(Phase to phase) & 230 volts±1%(Phase to neutral) Protection =Over voltage, under voltage & Overloading with TDR & Neutral failure protection,No. of Chambers = 3 No for each dimmer unit Buck-Boost. The Stabilizer shall be servo-controlled automatic ,ONAN cooled and provided with first filling of fresh filtered transformer oil having required dielectric strength .The Stabilizer shall be capable of smooth operation upto 10 % un-balanced in the load currents.The contractor /supplier has to give guarantee for any manufacturing defect with three servicing of the equipment for two year reckoned from commissioning.Inclusive of all applicapable taxes (Electrified /Automatic electric / Chinar / Alba / Casco make). The contractor has to faciltate testing of stabilizer at manufacturing site to departmental representative before despatching to site of work.The Job further includes CMC for a period of three years reckoned from date of sucessful commissioning (The comphrensive maintenance contract includes operation and maintenanace of stabilizer including replacement of damaged /burnt out accessories /equipments (what so ever reason) both mechanical as well as electrical completly by fresh one besides carrying timely servicing ) The complete inspection of Stabilizer shall be carried out by departmental representative not less than the rank of SDO at manufacturing site before assembling of stabilizer and contractor has to faciltate in all aspects the departmental representative uto manufacturing plant.
61Design/Fabrication/P/F of sheet steel Kiosk/Canopy suitable to house 160 KVA servo stabilizer fabricated out of 16 SWG M.S sheet having front door with locking arrangements and duly powder coated.
62Construction of Stone masonry bed using Class Ist dressed Q Stone. Bed shall be 8 ft in length, 8 ft wide and 2.5 ft in height above ground level and 1 ft deep under the ground. Cut work on exterior surface and cooping of cement concrete 4 inch thick laid on top of the bed with fine cement finish.The Job includes cost of 04 Inch PVC Pipe C-Class for Incoming/Outgoing of Cables.
63ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
64Supply/Excavation/Laying/Testing and Commissioning of 3.5-Core 120 mm sq. Al armored PVC cable withstand voltage of 650/1100V ISI Marked. Havells/Polycab/RR-Kabel/KEI Make. IIncluding Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01 Ft below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping.(Main Panel to AVR)
65Design/Supply/Installation/Testing and commissioning of distribution/feeder outdoor panel having a sloped roof (3+1) Al. bus bar of cubical type vermin proper double door lockable outdoor type fabricated out of 14/16 SWG MS Sheets powder coated weather proof, dust proof with IP 65 protection with angle iron 50x50x6mm stand painted in black colour of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects complete in all respects with followingIncoming: 400 Amp Suitable Al. Bus bar =01 Set.Outgoing: 1) 63Amp-4 pole,10kA TPN of L&T/Legrand/Schneider make as approved-01 No.2) 40 Amp-DP,10kA of L&T/Legrand/Schneider make as approved-01 No.3) 10-32 Amp-SP,10kA of L&T/Legrand/Schneider make as approved-08 No. Panel shall have provision for entry of cables from the bottom as required.The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel.
66Providing of Earthing Complete by GI Pipe 40mm 3 mtr long through GI Strip 25x3mm
67Supply/Laying/Testing and Commissioning of 3.5-Core 70 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01 Ft below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping.
68Part-B (High-Mast Lighting)
69Supply installation testing & Commissioning of 12.5 Mtr HM (in 2 section) suitable for 12 No. Luminaries high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter, EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable.The mast is constructed from mild steel plates (as per IS 5986 Gr. 510) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation.The OEM Must have Type test certificate for wind tunnel test . All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. (Bajaj/Philips/Valmont/Utkarash/Surya/BPP Make)
70Providing and Laying RCC Foundation ( 3ʹ x 3ʹ x 8ʹ) for (12.5 Mtr High mast Pole) with Following Procedure & All as per pre approved by Engineer in charge.A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with MT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting, propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade In footing and Pedestal including Curing the foundation for 7 days.
71Providing & Fixing of LED flood having housing made of pressure die cast aluminium alloy (ADC12/LM6). The system wattage shall be 175W & the luminaire shall deliver system lumens ≥ 25375 lumens. The system efficacy of the luminaire shall be ≥145lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700°K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK10. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV, HV Cut off @ 325V/440V Protection for 08 Hours. The luminaire shall have 10KV SPD in-built inside the luminaire. The nominal weight of the luminaire shall be maximum 4KGs.. The luminaire driver & it’s SPD shall be of the same make/manufacturer/Lighting Company as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material for approval. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to above specs in Signify(Philips/Ecolink) , LT & Ligman.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.(Philips/Wipro/LT Make)The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.
72Supply/Excavation/Laying/Testing and Commissioning of 4-Core 16 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount Make. Including Supply/Laying of HDPE Pipe SI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01 Ft below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping.
73Supply/Excavation & Laying of GI Pipe (A-Class) of 04 inches dia with ISI Marked for Road cut and refilling of same with cement concrete. (For Road Crossing)
74Design,Supply, Installation, Testing and Commissioning of CPRI Approved Main LT Control Double Door panel Slopped Roof fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door of 16 gauge sheet steel. The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Voltmeter, R/Y/B Phase-indicators etc & angle iron stand of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects complete in all respects with following:-Incoming: 63 Amp-4 pole,36kA MCCB with extended terminals L&T/ABB/Legrand/Simens Make.Outgoing: 1) 200 Amp Suitable Al. Bus bar & 01 No. 16-32 Amp 4 pole TPN MCB of L&T/ABB/Legrand/Simens Make as approved.2) By pass switch- 1 No. 3) Starter for motor operation (Forward and Reverse direction )- 1 No. 4) 6-10 A SP MCB -4 No.5)GIC Timer switch with 16-32 Amp Contactor for Auto operation of illumination lightings from dusk to dawn.The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel.
75Part-C (Auction Sheds Illumination)
76Supply/Installation/Testing and Commissioning of High Bay Surface/Suspended Type 100Watt,150 lm/w,IP Rating:1P65/IK 08,15000 lumens, Pressure Die cast Aluminium Housing & Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700, CRI ≥80,The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 140V to 270V,The Fixture should have In-built Surge Protection of 6kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The Job Includes Supply/Fixing of Suspension Kit for hanging of light.The job further includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of (Philips/Wipro/LT Make) Make & shall be approved not less than SDO.
77Wiring in 1.5 Sq. mm 3-Core flexible, PVC insulated, round sheathed and annealed bare multi stranded copper conductor withstand voltage up to 1.1 KV. Polycab/Havells/RR-Kabel/Salzer/Finolex/Paraflex/Equivalent Make for service connection wires from each Bay light to Panel. (Complete in all respects)
78Supply/Fixing and Crimping of 16/25/35/50 Sq. mm aluminium lugs,cable thimbles at termination of the cables/ends including providing of insulation tapes.
79Supply/Laying of 25/32mm Dia PVC Conduit of Anchor/Ravinder/Polypack/Finolex Make with other accessories like bends,etc complete to be laid in Ceiling/wall etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58488182
AUTHORITY Government Departments
TENDER VALUE 2.54 Crore
LAST DATE 19-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Additional Multistory/Multipurpose Auction Phar/Platform At F&V Market Zazna Ganderbal.
Basic Detail
Tender No NIT No.90-2026-27
Bidding Type Tender
Location
City Ganderbal
State Jammu and Kashmir
Key Dates
Publish Date 12 Nov 2026
Submission Date 19 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 2.54 Crore
Tender Fee 5500
EMD 5.09 Lakhs
Exemption Not Available
Document List
9d284b0a-9307-4d41-824a-5da777f4a582.html
BOQ_1123284.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 19, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 19, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
html

9d284b0a-9307-4d41-824a-5da777f4a582.html

xls

BOQ_1123284.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender