Tender For Repairs To Cyclone Centre Building Thoduvai @ Thirumullaivasal Panchayat In Kollidam Panchayat In Mayiladuthurai District Under Disaster Management 2026-2027
Tender Value
22.40 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
13 days left
EMD
22500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mayiladuthurai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Cyclone Centre Building Thoduvai @ Thirumullaivasal Panchayat In Kollidam Panchayat In Mayiladuthurai District Under Disaster Management 2026-2027
BOQ
| Sl. No. | Item Description |
| 1 | Repairs to Cyclone Centre Building Thoduvai @ Thirumullaivasal Panchayat in Kollidam Panchayat |
| 2 | Dismantling and removing the Damaged plastering surface and clearing the unused materials away from the site as per specifications etc complete.W-0104 P.NO 34 |
| 3 | Plastering in CM 1:5 , 12mm thick including cost and conveyance of all materials and all labour charges etc., complete. |
| 4 | Roof Ceiling Plastering |
| 5 | Chipping of Concrecte and roughening the surface( m-0036) |
| 6 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 7 | Floor Finishing |
| 8 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone M.Sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 9 | Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone M.Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 10 | Dismantaling of damaged floor finish & Dadooing Walls in Cement Mortor with Mosaic tiles/Glazed tiles/clay tiles Cuddapah slab including cost conveyance of all etc complete W-0042 p.NO 31 |
| 11 | Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone M.Sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 12 | Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M.Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. |
| 13 | Dadooing of walls with colour glazed tiles of size300x200x6 mm of best quality including cost and conveyance of all materials to site and all labour charges etc complete. |
| 14 | Door Repairs/Replacement |
| 15 | Cost & supply of steel door of size (0.75 x 2.10) |
| 16 | Fixing of Steel window of size (0.90 X 1.20) as per specifications etc complete |
| 17 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work. |
| 18 | Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). |
| 19 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 20 | Painting two coats with ready mix paint of approved colour and trade for doors & windows including cost and conveyance of all materials and all other labour charges etc., complete. |
| 21 | Sub Estimat Elders sitting slab |
| 22 | Brick work in C.M 1:5 mix using country bricks of size 83/4” x 41/4 \\" x 21/4\\" , including cost and conveyance of all materials to worksite, including labour for watering with good water within 200m Lead for good water, including all labour and all other incidental charges etc. complete for UP TO BASEMENT. |
| 23 | Reinforced Cement Concrete 1:11.5:3 mix using 20mm ISS size HBG metal from approved quarry, including cost and conveyance all materials to worksite including labour for mixing, laying, watering with in 200m lead for good water, compacting the concrete including all labour for forming formwork and centering charges etc., |
| 24 | Supplying & Erecting centering for sides & soffiots including necessary supports & strutting upto 3.29m height for plane surfaces in all floors with all cross bracings using mild steel sheets of size 90 x 60cm & 10 gauge stiffened, welded with steel angle of size 25 x 25 x 3mm for boarding laid over silver oak joists(Country wood) of size 10 x 6.5cm spaced @ about 90cm c/c and supported by casurina props of 10 - 13cm dia. spaced @ 75cm c/c etc., |
| 25 | Supply and fabrication of steel including cost and conveyance of steels from godown to work site including labour for cutting, jointing and welding if necessary including labour for tieing with binding wire and labour for placing in position as directed by departmental officers, including all labour and all other incidental charges etc., complete for all RCC items. |
| 26 | Plastering with Cement Mortar 1:5, 12mm thick including cost and conveyance of all materials to worksite, and all labour for watering, curing and all leads for good water including cost of form work, and all labour and all other incidental charges etc. complete. |
| 27 | Sub Estimate Baby feeding Room |
| 28 | Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work M-0390 P.N0 84 |
| 29 | Supplying and fixing of door shutter using MDF board of exterior grade both sides prelaminated of 35mm thick for double leaf door of size 1.00x2.10m |
| 30 | provision for Secren with satinless steel handle |
| 31 | Sub Estimate New toilet |
| 32 | Earthwork Excavation in Hard Soil - Earthwork excavating and depositing with in initial lead of 10m and lift of 2m (For roads, supply channels, desilting of MI Tanks, Pond & Kulam) |
| 33 | Collection and supply of Sand and filling into the basement including cost and conveyance to the site and all labour charges for filling as per standard specification. |
| 34 | Cement mortar 1:4:8 mix using 40mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing etc complete for 10 cum |
| 35 | Reinforced Cement mortar 1:1.5:3 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing etc complete for 10 cum |
| 36 | Column upto basement |
| 37 | Column upto Roof |
| 38 | CENTERING ABOVE GL: Supplying and erecting centering shuttering including necessary supports for plane surface in foundation and basement and in all floors for R C C column footing column plinth beam, beams, roof slabs, staircase steps, bed blocks, critical pier etc using mild steel sheets of size 90 x 60 cm and 10 guage stiffened, welded with mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak (country wood) scantlings of size 10cm x 6.5cm spaced of about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at 75cm centre to centre complete complying with standard specifications and as directed by departmental officers including conveyance of all materials to site and proper centering etc complete. |
| 39 | Column upto basement |
| 40 | Column upto roof |
| 41 | Supplying and fabrication of steel including cost and conveyance of steel to site and all labour charges for straightening, cutting to length, bending to shape and tying in position and forming grills for all R.C.C works |
| 42 | Brick work in cement mortar 1:5 mix using country bricks 83/4x41/4x23/4 and conveyance of all materials to site and all labour charges etc complete (above Basement) |
| 43 | For Basement |
| 44 | For Superstructure |
| 45 | Plastering with cement mortar 1:5 mix to 12mm thick including cost and conveyance of all materials to site and all labour charges etc |
| 46 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work. |
| 47 | Paving the Floor with scratch proof ceramic tiles of size 305x305x6mm including cost and conveyance of all materials to site and all labour charges etc complete |
| 48 | Dadooing of walls with colour glazed tiles of size150x150x6 mm of best quality including cost and conveyance of all materials to site and all labour charges etc complete. |
| 49 | Cost & supply of steel door |
| 50 | Door .75x2.10 |
| 51 | Door 1.20x2.10 |
| 52 | Supplying and fixing of RCC jolly of size 0.45x 0.45m including all charges etc complete |
| 53 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and approved colour over a priming coat including through scrapping, clean removal of dirt and including necessary plaster of pairs putty, wherever required etc complete complying with standard specification |
| 54 | Supplying and fixing in position of Indian Type water closet 580x440mm of approved qualitiy |
| 55 | European water closet with all fittings and 10 lit capacity flushing tank |
| 56 | PVC Storage tank including all charges etc complete |
| 57 | Towards cost and supply of Precast RCC Rings including all charges etc complete. |
| 58 | Towards cost and supply of Hand Rails for Stainless steel including all charges etc complete. |
| 59 | Supply and fixing 110mm dia PVC Pipe |
| 60 | Sub Estimate Borewell |
| 61 | Drilling of 140/ 150mm dia pilot borewell using calyx rigs WD-W0834 P:No 222 sor 2025-2026 |
| 62 | Reaming from 200 mm dia pilot borewell to 300mm dia WD-W-0835 p:no 222 |
| 63 | Labour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board p.no:222 WD -W0836 |
| 64 | Charges for developing the bore well with air compressor of 300 cfm p:no 223 WD-W0839 |
| 65 | Supply and delivery of 200 mm OD PVC Plain casing pipes 6 KSC P:NO 7 WD-M-0030 |
| 66 | Supply and delivery of 200mm PVC end cap p:no 11 WD-M0115 |
| 67 | Supply and delivery of 65 mm UPVC COLUMN pipe 6Ksc P.n-8 WD-M0052 |
| 68 | Supply and delivery of 65mm PVC end cap p:no 11 WD-M0115 |
| 69 | Supply and delivery of 63 mm PVC Elbow pipe 6Ksc P.n-10 WD-M0112 |
| 70 | Supply and delivery of 65 mm GI Elbow p.no;36 M-0594 |
| 71 | Supply and delivery of 65 mm GI Pipe P;no 30 M-0490 |
| 72 | Supply and delivery of 65 mm GI Coupling P.NO:36 WD-M-0596 |
| 73 | Supply and delivery of 65 mm GI Bend P.NO:36 WD-0602 |
| 74 | Supply and delivery of 50 mm dia GM Gate valve p:no 37 M-0618 |
| 75 | Supply and delivery of 65 mm dia GI Flange set p:no 36 M-0597 |
| 76 | Solvent Cement |
| 77 | Supplying 1 HP Submersible pump with ISI make including cost and conveyance of all materilas and labour charges etc complete as per standerd specification M-1581 Page No:-116 |
| 78 | Supply and delivery of 4sqmm Submerssible cable P:NO 140 M-1975 |
| 79 | 150 mm ms clamp set WD -M0617 P.NO32 |
| 80 | Bore cap using M.S. Flat of size 1 cm x 3 mm and M.S. sheet on top with bolting arrangements for securing the cap in position (Bore caps with M.S. Couplings need not be made) P.no :215 WD-W0738 |
| 81 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. P:NO:226 W-0871 |
| 82 | Wiring 2 x 1.5 sq.mm (22/0.30)PVC insulated unsheathed SC.cu.conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with in flush with wall covered with hylem sheet of 3 mm thick with painting of suitable colour for concealed PVC light/ fan point (SD No.25) |
| 83 | Supply and run of 2 of 1.50 Sq.mm polythene insulated PVC sheathed heavy duty SC Copper conductor of 1100 V grade on 7/20 GI bearer wire for service connection mains (SD No.64) |
| 84 | Supply and run of 2x4 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains SD 70 |
| 85 | Sub Estimate Rain water harvesting |
| 86 | Earthwork excavation for foundation in all soils and sub-soils to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring, strutting and baling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15cm thick well rammed and consolidated and depositing the surplus earth in all places shown by the departmental officers with inital leads and lifts, etc. Including leveling the sites complete complying with standard specifications and as directed. In sand or other loose soil, wet sand not under water, silt, light black cotton soil, sandy loams and ordinary soil. TNBP SS NO 20B 23 & 24 |
| 87 | Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 88 | Supplying and filling with20mm HBG metal including cost and conveyance of metal to work site including all labour charges for filling etc., complete. |
| 89 | Supplying and filling with 40mm HBG metal including cost and conveyance of metal to work site including all labour charges for filling etc., complete. |
| 90 | Supplying and fixing RCC Rings of inner dia 90cm including cost and conveyance including all labour charges for laying etc., complete. |
| 91 | Supplying and delivery of the following materials |
| 92 | 110mm OD PVC Pipe 6kg |
| 93 | 110mm Pvc Door bend |
| 94 | 110 mm dia PVC Tee |
| 95 | Wooden plug clamp and screw set m-0517 |
| 96 | Plumber I Class 1 No. |
| 97 | Sub Estimate Electrification |
| 98 | Wiring 2 x 1.5 sq.mm (22/0.30)PVC insulated unsheathed SC.cu.conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with in flush with wall covered with hylem sheet of 3 mm thick with painting of suitable colour for concealed PVC light/ fan point (SD No.20) |
| 99 | WT Bulk head fitting sd 83 |
| 100 | Wiring 2 x 1.5 sq.mm (22/0.30)PVC insulated unsheathed SC.cu. conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with in flush with wall covered with hylem sheet of 3 mm thick with painting of suitable colour for concealed PVC plug point (SD No.38) 5 pin plug point |
| 101 | supply and fixing of 1200mm sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp SD 106 |
| 102 | Supply and fixing of tube light fitting including angle holder.SD 88 |
| 103 | Supply and Fixing 18 w cfl in the existing light point SD 83 |
| 104 | Supply and fixing of TNEB meter Board suitable for 32A Single Phase service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" Copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit. (SD No. 125) |
| 105 | Supply and run of 2x4 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains SD 70 |
| 106 | Supply and Fixing of 16 Amps DP Switch of 500V with Metal Clad with Fuse and Neutral SD 142 |
| 107 | SD 64 |
| 108 | SD 69 |
| 109 | Sub Estimate Sanitary Arrengements |
| 110 | 110mm Pvc pipe 6 KG WD-M-0013 P.no 5 |
| 111 | 75mm Pvc pipe 6 KG WD-M0010 P.NO 5 |
| 112 | 110mm Pvc bend WD-M-0107 P.NO 11 |
| 113 | 110mm Pvc elbow WD-M0112 P.NO 11 |
| 114 | 110mm Pvc Tee WD-M0113 P.NO 11 |
| 115 | 75 MM PVC ELOW WD-M0112 P.NO 11 |
| 116 | 110mm Pvc Tee WD-M0113 P.NO 11 |
| 117 | 20 MM Pvc pipe( M-0875) VOLLUME 1 P.NO 18 |
| 118 | 25 MM Pvc pipe( M-0876) VOLLUME 1 P.NO 158 |
| 119 | 25 MM TEE (M-0900) P.NO 160 |
| 120 | 20 MM TEE(M-0899) P.NO 160 |
| 121 | 25 MM BEND(M-0894) P.NO 160 |
| 122 | 20 MM BEND(M-0893) P.NO 159 |
| 123 | 20 MM ELBO (M-0887) P.NOI 159 |
| 124 | 25 MM COUPLER(M-0882) P.NO 159 |
| 125 | Shellac(M-0518) P.NO 91 |
| 126 | UPVC Adhesive m-0520 P.NO 92 |
| 127 | 5000 litres water tank m-0540 P.NO 92 |
| 128 | 25mmGI pipe m-0437 P.NO 87 |
| 129 | 25mmGI Tee m-0461 P.NO 88 |
| 130 | 25mmGI Bend m-0455 P.NO 88 |
| 131 | 25mm GI Elbow m-0449 P.NO 88 |
| 132 | 25mm GI Bend m-0455 P.NO 88 |
| 133 | PVC Screw Down tap 20 mm dia M-0511 P.NO 91 |
| 134 | Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers |
| 135 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone M.Sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three M.Sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 136 | Supplying and fixing in position of Indian Type water closet 580x440mm of approved qualitiy |
| 137 | Europeon Water Closet with all fittings and 10lit capacity flusing tank |
| 138 | Supplying laying and jointing PVC specials etc., complete |
| 139 | Provision for Name board |
| 140 | GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column \\"BB\\" for all works in this package} Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysDec 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents