Tender For Special Repairs To Ei, Renewal Of Led Fittings, Water Heater, Ac Unit To The Kodaganar Illam At Dindigul In Dindigul District
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Nov 2026
9 days left
EMD
2000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dindigul → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Ei, Renewal Of Led Fittings, Water Heater, Ac Unit To The Kodaganar Illam At Dindigul In Dindigul District
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (for electronic regulator) (5 points per coil). |
| 2 | Renewal by supply and fixing of 18W LED Crystal glass Tube light on existing SBT fitting with necessary connection. |
| 3 | Renewal by supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting. |
| 4 | Renewal by supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 5 | Renewal by supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting |
| 6 | Renewal by supply and fixing of 48W LED street light fitting on the existing 6 mtr post with PVC unsheathed cu.leads with testing complete. |
| 7 | Renewal by supply and fixing of 1500 watts automatic Electric Water Heater of 25 litres capacity suitable for 230V 50 c/s AC supply on suitable MS Clamps with 3 core flex wire but without plumbing connection. |
| 8 | Renewal by supply and fixing of 5 A 3 Pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable TW box in flush with wall and concealed with 3mm thick hylem sheet. |
| 9 | Renewal by supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. |
| 10 | Renewal by supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 3 nos. 32A 3P MCB , 15 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. |
| 11 | Renewal by supply and laying of 2 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. |
| 12 | Renewal by supply and clamping of 2 x 10 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps |
| 13 | Renewal by supply and fixing of brass cable gland for 2 x 10 sq.mm PVC armoured LTUG cable, with earth connection. |
| 14 | Renewal by supply erection, testing and commissioning of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of |
| 15 | CoolingDehumidifyingAir CirculatingFilteringThe installation works for the above split type AC units includes the following.1.Mounting / Fitting Indoor and outdoor units at their respective locations.2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required. |
| 16 | 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.5. Leakage testing the entire system unit.6. Charging refrigerant gas in the unit.7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit |
| 17 | Renewal by supply of 5 KVA Electronic Automatic Voltage Stabilizer V-GUARD make VGS 500 Model/Eq with Input Voltage range of 170Volt – 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. |
| 18 | Renewal by supply and fixing of MS angle Iron Frame work to rest the Outdoor unit. |
| 19 | Renewal by supply and laying of 5/8\\" and 3/8\\" copper refrigerant pipe of 0.8mm thick with 2.5sqmm 3 core chord between indoor and outdoor unit. (Extra beyond 3 mts/AC unit) |
| 20 | GST@ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer