Communications and Information Technology Government Departments Closing in 10 days TDR #58484854

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 45 Attending Breakdown Complaints And B Check Servicing Of 10 Nos Various Dg Sets On Call Basis Under Kodagu Oa Phase 3; Power Generators; Service P

Issued by Government Departments · Bengaluru Urban, Karnataka
Tender Value
4.65 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
10 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 45 Attending Breakdown Complaints And B Check Servicing Of 10 Nos Various Dg Sets On Call Basis Under Kodagu Oa Phase 3; Power Generators; Service Provider - Replacement Of Alternator Winding Of 40Kva, 3Phase, 415 Volts Dg Set [Against Burnt Alternator Winding] I/C Dismantling Alternator, Taking It Out From The Canopy, Transportation Of Same From Hakattur To Near By Alternator Rewinding Shop To & From By Engaging A Suitable Transport Vehicle, Rewinding Of Alternator With Suitable Copper Conductor, Varnishing, Prdg Rated Insulation, Baking, Physical Checks, Fixing Same To Alternator At Hakattur, Exciting With Battery Supply Externally To The Field To Magnetise The Core, Testing Running The Dg, Checking Output & Parameters On Both Noload & On Exchange Load Etc As Reqd. , Replacement Of Damaged/ Burnt Dc Control Wiring From Starter To Ignition Board And To Dynamo With Suitable Copper Conductor Wires And Lugs Etc To Avoid Further Burning Of The Wiring Upon Starting Etc As Reqd. , Replacement Of Stator Winding Of 20Kva, 3Phase, 415 Volts Dg Set ( Against Burnt Winding ) I/C Dismantling Alternator, Taking It Out From The Canopy, Transportation Of Same From Hattihole To Near By Alternator Rewinding Shop To & From By Engaging A Suitable Transport Vehicle, Rewinding Of Stator With Suitable Copper Conductor, Varnishing, Prdg Rated Insulation, Baking, Physical Checks, Fixing Same To Alternator At Hattihole, Exciting With Battery Supply Externally To The Field To Magnetise The Core, Testing Running The Dg, Checking Output & Parameters On Both Noload & On Exchange Load Etc As Reqd. , B-Check Servicing Of Following Capacity Dg Set By Engaging Dg Mechanic By Utilising The Existing Consumables Like Oil, Filters Etc, Draining Out Of Engine Oil From The Sump, Filling New Oil, Replacing Fuel And Oil Filters, Oil Bath Type Air Filter, Tightening All The Bolts & Nuts To The Reqd Torque, General Check Up Of Working Parameters And Checking The V-Belt, Testng As Reqd. (Consumables Like Oil, Filters Will Be Paid Separately) , Supply Of The Following Consumables / Spares For The Engine During Servicing / Repair Works , Testing Complete As Required. Make :- Kirloskar/Volvoline/ Servo /Castrol/ Shell Simlr Supr Make & Grades. , Lube Oil Filter With O Ring. , Diesel Filters- Set Of 2 (Pre & Micro) With O Ring , Replacement Of V Belts Of Size A-28/A-32/ A-40 / A-46/ A-48/ A-49/ A-51 , S&F Of Hydraulic/ Metal Braided Flexible Fuel Pipe With Banjo Bolts & Copper Washers Etc. Up To 2½ Feet Long. , S&F Of Hydraulic/ Metal Braided Flexible Fuel Pipe With Banjo Bolts & Copper Washers Etc. 3 Feet To 5 Feet Long. , S&F Of Pvc Braided Flexible Fuel Pipe With Banjo Bolts & Copper Washers Etc. Up To Up To 2½ Feet Long. , S&F Of Pvc Braided Flexible Fuel Pipe With Banjo Bolts & Copper Washers Etc. 3 Feet To 5 Feet Long. , S&F Of Nozzle Return Pipe , S&F Of Oil Pressure Hose Pipe Of Suitable Length , Replacement Of Ignition Switch Unit Normally Open Type With Operating Key Suitable For Above Dg Sets I/C Making Connection, Checking Etc As Reqd. , Providing Self Adhessive Waterproof Sealing Black Tar Felt Asphalt Sheet/ Water Proof Sheet At The On The Roof/ Top Side Of Dg Set Canopy Of Size Apprx 2.5Mtrs X 1.5Mtrs To Avoid Seapage Of Rain Water Inside Canopy I/C Covering It Fully Leaving No Room For Rain Water Entry Inside With Associated Spares Complete Etc As Reqd. , S&F Of Counter Type Electrical Run Hour Meter Operating On 230V, 1 Ph, 50Hz, Ac Supply I/C Connecting To The Existing Power Cable With Necessary Terminations And Clamping If Required Etc As Reqd. (Make: Quartz//Krish/ Isi Approved) , Repair Of Faulty 12 Volts Dynamo Of Dg Set I/C Transportation To Work Shop To & From, Replacement Of Commutator, Set Of Carbon Brushes With Cutouts, Fixing The Same To The Dg Set And Testing, Checking The Output Voltage Complete Etc As Reqd. , Repair Of Faulty 12 Volts Starter Of Dg Set I/C Transportation To Work Shop To & From, Replacement Of Bentex, Rectifier, Set Of Bearings, Shaft Fixing The Same To The Dg Set And Testing, Checking The Output Voltage Complete Etc As Reqd. , Supply And Fixing The Electronic Type Automatic Voltage Controller Suitable For 15/20/40 Kva Capacity Alternator Etc As Reqd. Note [Optional Item, It May Be Supplied After Consent Of Sde/Jto(Ele @ Site) (Make : Oem/ Swastik Or Approved Make) , Supply And Fixing Battery Lead Of Size 25Sqmm Pvc Insulated Multistrand Single Core Copper Conductor Cable And Properly Bolted To Existing Terminal Etc As Reqd. , Supply And Fixing 2 Nos Brass Terminals For Battery Positive & Negetive Polarities With Bolts And Nuts Etc As Reqd. , Supply And Fixing Ms Wired 1 X 1 Welded Wire Mesh Of Following Sizes With Screws/ Nuts/ Bolts/ Washers Etc To Cover The Opened Portion At Flywheel Side/ Alternator Side To Avoid Rodent Entries/ Safety To The Operating Personal Etc As Reqd. , Dismantling The Radiator Assembly From Existing 15/20/30/40 Kva Capacity Dg Set, Servicing And De-Scaling The Radiator At Site, Water Wash, Flushing, Removing The Blockages If Any, Checking For The Leakages, Refixing The Radiator Assembly To The Dg With Its Accessories Etc As Reqd. , Supply & Fixing Of Radiator Hose Pipes (Straight/ Bent) Of Suitable Size, Thickness And Length With Ring/ Banjo Clamps To The Radiator Of 15/20/30/40 Kva Capacity Dg Set Etc As Reqd. , Complete Cleaning Of Upto 40Kva Existing Dg Set I/C Removing The Dust, Sticky Dirts, Sediments, Oil Spillages, Carbon Deposits With Existing Diesel/ Cleaning Agents Then Dry Cleaning, Then Painting With Enamelled Oil Paint Matching To Existing Colour, Finishing, Making It Neat Complete Etc As Reqd. , Supply & Fixing Of Ms Hinges To The Doors Of The Dg Canopy I/C Drilling, Fixing, Welding, Fabrication Work Complete Etc As Reqd. , Sitc Of 12 Volts, 10 Amps Battery Charger Smps Type To Charge Dg Set Batteries Suitable For Operation On 230 V, 50Hz Input Ac Supply Of Range 170V To 270V, Output 13.3V To 13.8Volts Dc, With Protections For Over Current, Over Charging, Reverse Polarity Complete With Power Supply Cable, Termination Points And Other Accessories Etc I/C Supply Of Heavy Duty Charging Crocodile Clips-2Nos Etc Complete As Reqd. (Make: Nhp Or Ss Make)

BOQ

Sl. No. Item TitleItem Description
1Replacement of Alternator winding of 40kVA, 3Phase, 415 Volts DG set [Against Burnt Alternator winding] i/c dismantling alternator, taking it out from the canopy, transportation of same from Hakattur to near by Alternator Rewinding shop to & from by engaging a suitable transport vehicle, rewinding of Alternator with suitable copper conductor, varnishing, prdg rated insulation, baking, Physical checks, fixing same to alternator at Hakattur, exciting with Battery supply externally to the field to magnetise the core, testing running the DG, checking output & parameters on both noload & on exchange load etc as reqd.Replacement of Alternator winding of 40kVA, 3Phase, 415 Volts DG set [Against Burnt Alternator winding] i/c dismantling alternator, taking it out from the canopy, transportation of same from Hakattur to near by Alternator Rewinding shop to & from by engaging a suitable transport vehicle, rewinding of Alternator with suitable copper conductor, varnishing, prdg rated insulation, baking, Physical checks, fixing same to alternator at Hakattur, exciting with Battery supply externally to the field to magnetise the core, testing running the DG, checking output & parameters on both noload & on exchange load etc as reqd.
2Replacement of damaged/ Burnt DC control wiring from starter to Ignition board and to Dynamo with suitable copper conductor wires and lugs etc to avoid further burning of the wiring upon starting etc as reqd.Replacement of damaged/ Burnt DC control wiring from starter to Ignition board and to Dynamo with suitable copper conductor wires and lugs etc to avoid further burning of the wiring upon starting etc as reqd.
3Replacement of Stator winding of 20kVA, 3Phase, 415 Volts DG set ( Against Burnt Winding ) i/c dismantling alternator, taking it out from the canopy, transportation of same from Hattihole to near by Alternator Rewinding shop to & from by engaging a suitable transport vehicle, rewinding of Stator with suitable copper conductor, varnishing, prdg rated insulation, baking, Physical checks, fixing same to alternator at Hattihole, exciting with Battery supply externally to the field to magnetise the core, testing running the DG, checking output & parameters on both noload & on exchange load etc as reqd.Replacement of Stator winding of 20kVA, 3Phase, 415 Volts DG set ( Against Burnt Winding ) i/c dismantling alternator, taking it out from the canopy, transportation of same from Hattihole to near by Alternator Rewinding shop to & from by engaging a suitable transport vehicle, rewinding of Stator with suitable copper conductor, varnishing, prdg rated insulation, baking, Physical checks, fixing same to alternator at Hattihole, exciting with Battery supply externally to the field to magnetise the core, testing running the DG, checking output & parameters on both noload & on exchange load etc as reqd.
4B-check Servicing of following Capacity DG set by engaging DG mechanic by utilising the existing consumables like Oil, filters etc, draining out of Engine oil from the sump, filling new Oil, replacing Fuel and Oil filters, oil bath type air filter, tightening all the bolts & nuts to the reqd torque, general check up of working parameters and checking the V-belt, testng as reqd. (Consumables like oil, filters will be paid separately)B-check Servicing of following Capacity DG set by engaging DG mechanic by utilising the existing consumables like Oil, filters etc, draining out of Engine oil from the sump, filling new Oil, replacing Fuel and Oil filters, oil bath type air filter, tightening all the bolts & nuts to the reqd torque, general check up of working parameters and checking the V-belt, testng as reqd. (Consumables like oil, filters will be paid separately)
5Supply of the following consumables / spares for the Engine during servicing / repair works , testing complete as required. Make :- Kirloskar/Volvoline/ Servo /Castrol/ Shell Simlr Supr make & grades.Supply of the following consumables / spares for the Engine during servicing / repair works , testing complete as required. Make :- Kirloskar/Volvoline/ Servo /Castrol/ Shell Simlr Supr make & grades.
6Lube Oil Filter with 'O' Ring.Lube Oil Filter with 'O' Ring.
7Diesel Filters- set of 2 (Pre & Micro) with 'O' RingDiesel Filters- set of 2 (Pre & Micro) with 'O' Ring
8Replacement of 'V' Belts of Size A-28/A-32/ A-40 / A-46/ A-48/ A-49/ A-51Replacement of 'V' Belts of Size A-28/A-32/ A-40 / A-46/ A-48/ A-49/ A-51
9S&F of Hydraulic/ metal Braided flexible fuel pipe with Banjo Bolts & Copper washers etc. up to 2½ feet long.S&F of Hydraulic/ metal Braided flexible fuel pipe with Banjo Bolts & Copper washers etc. up to 2½ feet long.
10S&F of Hydraulic/ metal Braided flexible fuel pipe with Banjo Bolts & Copper washers etc. 3 feet to 5 feet long.S&F of Hydraulic/ metal Braided flexible fuel pipe with Banjo Bolts & Copper washers etc. 3 feet to 5 feet long.
11S&F of PVC Braided flexible fuel pipe with Banjo Bolts & Copper washers etc. up to up to 2½ feet long.S&F of PVC Braided flexible fuel pipe with Banjo Bolts & Copper washers etc. up to up to 2½ feet long.
12S&F of PVC Braided flexible fuel pipe with Banjo Bolts & Copper washers etc. 3 feet to 5 feet long.S&F of PVC Braided flexible fuel pipe with Banjo Bolts & Copper washers etc. 3 feet to 5 feet long.
13S&F of Nozzle Return PipeS&F of Nozzle Return Pipe
14S&F of Oil Pressure Hose Pipe of Suitable LengthS&F of Oil Pressure Hose Pipe of Suitable Length
15Replacement of Ignition Switch unit Normally Open type with operating Key suitable for above DG sets i/c making connection, checking etc as reqd.Replacement of Ignition Switch unit Normally Open type with operating Key suitable for above DG sets i/c making connection, checking etc as reqd.
16Providing self adhessive Waterproof Sealing Black Tar Felt Asphalt Sheet/ Water proof sheet at the on the Roof/ top side of DG set Canopy of size Apprx 2.5Mtrs X 1.5Mtrs to avoid seapage of Rain water inside canopy i/c covering it fully leaving no room for rain water entry inside with associated spares complete etc as reqd.Providing self adhessive Waterproof Sealing Black Tar Felt Asphalt Sheet/ Water proof sheet at the on the Roof/ top side of DG set Canopy of size Apprx 2.5Mtrs X 1.5Mtrs to avoid seapage of Rain water inside canopy i/c covering it fully leaving no room for rain water entry inside with associated spares complete etc as reqd.
17S&F of Counter Type Electrical Run Hour meter operating on 230V, 1 Ph, 50Hz, AC Supply i/c connecting to the existing power cable with necessary terminations and clamping if required etc as reqd. (Make: Quartz//Krish/ ISI Approved)S&F of Counter Type Electrical Run Hour meter operating on 230V, 1 Ph, 50Hz, AC Supply i/c connecting to the existing power cable with necessary terminations and clamping if required etc as reqd. (Make: Quartz//Krish/ ISI Approved)
18Repair of faulty 12 Volts Dynamo of DG set i/c transportation to work shop to & from, replacement of Commutator, set of carbon brushes with cutouts, fixing the same to the DG set and testing, checking the output voltage complete etc as reqd.Repair of faulty 12 Volts Dynamo of DG set i/c transportation to work shop to & from, replacement of Commutator, set of carbon brushes with cutouts, fixing the same to the DG set and testing, checking the output voltage complete etc as reqd.
19Repair of faulty 12 Volts Starter of DG set i/c transportation to work shop to & from, replacement of Bentex, Rectifier, set of Bearings, Shaft fixing the same to the DG set and testing, checking the output voltage complete etc as reqd.Repair of faulty 12 Volts Starter of DG set i/c transportation to work shop to & from, replacement of Bentex, Rectifier, set of Bearings, Shaft fixing the same to the DG set and testing, checking the output voltage complete etc as reqd.
20Supply and Fixing the Electronic type Automatic Voltage Controller suitable for 15/20/40 KVA Capacity alternator etc as reqd. Note [Optional Item, it may be supplied after consent of SDE/JTO(Ele @ Site) (Make : OEM/ Swastik or Approved Make)Supply and Fixing the Electronic type Automatic Voltage Controller suitable for 15/20/40 KVA Capacity alternator etc as reqd. Note [Optional Item, it may be supplied after consent of SDE/JTO(Ele @ Site) (Make : OEM/ Swastik or Approved Make)
21Supply and Fixing battery lead of size 25Sqmm PVC insulated Multistrand Single Core copper conductor cable and properly bolted to existing terminal etc as reqd.Supply and Fixing battery lead of size 25Sqmm PVC insulated Multistrand Single Core copper conductor cable and properly bolted to existing terminal etc as reqd.
22Supply and Fixing 2 Nos brass terminals for battery Positive & Negetive polarities with bolts and Nuts etc as reqd.Supply and Fixing 2 Nos brass terminals for battery Positive & Negetive polarities with bolts and Nuts etc as reqd.
23Supply and Fixing MS wired 1\\" x 1\\" welded wire mesh of following sizes with screws/ nuts/ Bolts/ Washers etc to cover the opened portion at Flywheel side/ Alternator side to avoid rodent entries/ safety to the operating personal etc as reqd.Supply and Fixing MS wired 1\\" x 1\\" welded wire mesh of following sizes with screws/ nuts/ Bolts/ Washers etc to cover the opened portion at Flywheel side/ Alternator side to avoid rodent entries/ safety to the operating personal etc as reqd.
24Dismantling the Radiator Assembly from existing 15/20/30/40 kVA Capacity DG set, Servicing and de-scaling the radiator at site, Water wash, flushing, removing the blockages if any, Checking for the leakages, refixing the Radiator assembly to the DG with its accessories etc as reqd.Dismantling the Radiator Assembly from existing 15/20/30/40 kVA Capacity DG set, Servicing and de-scaling the radiator at site, Water wash, flushing, removing the blockages if any, Checking for the leakages, refixing the Radiator assembly to the DG with its accessories etc as reqd.
25Supply & Fixing of Radiator hose pipes (straight/ Bent) of suitable Size, thickness and Length with Ring/ Banjo clamps to the radiator of 15/20/30/40 kVA Capacity DG set etc as reqd.Supply & Fixing of Radiator hose pipes (straight/ Bent) of suitable Size, thickness and Length with Ring/ Banjo clamps to the radiator of 15/20/30/40 kVA Capacity DG set etc as reqd.
26Complete cleaning of upto 40kVA existing DG set i/c removing the dust, sticky dirts, sediments, oil spillages, carbon deposits with existing diesel/ cleaning agents then dry cleaning, then painting with enamelled oil paint matching to existing colour, finishing, making it neat complete etc as reqd.Complete cleaning of upto 40kVA existing DG set i/c removing the dust, sticky dirts, sediments, oil spillages, carbon deposits with existing diesel/ cleaning agents then dry cleaning, then painting with enamelled oil paint matching to existing colour, finishing, making it neat complete etc as reqd.
27Supply & Fixing of MS Hinges to the Doors of the DG canopy i/c drilling, fixing, welding, fabrication work complete etc as reqd.Supply & Fixing of MS Hinges to the Doors of the DG canopy i/c drilling, fixing, welding, fabrication work complete etc as reqd.
28SITC of 12 Volts, 10 Amps battery Charger SMPS type to charge DG set batteries suitable for operation on 230 V, 50Hz Input AC supply of range 170V to 270V, Output 13.3V to 13.8Volts DC, with protections for Over current, Over Charging, Reverse Polarity complete with power supply cable, termination points and other accessories etc i/c supply of heavy duty charging crocodile clips-2Nos etc complete as reqd. (Make: NHP or SS make)SITC of 12 Volts, 10 Amps battery Charger SMPS type to charge DG set batteries suitable for operation on 230 V, 50Hz Input AC supply of range 170V to 270V, Output 13.3V to 13.8Volts DC, with protections for Over current, Over Charging, Reverse Polarity complete with power supply cable, termination points and other accessories etc i/c supply of heavy duty charging crocodile clips-2Nos etc complete as reqd. (Make: NHP or SS make)

AI Tender Summary

OUR REF NO 58484854
AUTHORITY Government Departments
TENDER VALUE 4.65 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Department Of Telecommunications
Work Description Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 45 Attending Breakdown Complaints And B Check Servicing Of 10 Nos Various Dg Sets On Call Basis Under Kodagu Oa Phase 3; Power Generators; Service Provider - Replacement Of Alternator Winding Of 40Kva, 3Phase, 415 Volts Dg Set [Against Burnt Alternator Winding] I/C Dismantling Alternator, Taking It Out From The Canopy, Transportation Of Same From Hakattur To Near By Alternator Rewinding Shop To & From By Engaging A Suitable Transport Vehicle, Rewinding Of Alternator With Suitable Copper Conductor, Varnishing, Prdg Rated Insulation, Baking, Physical Checks, Fixing Same To Alternator At Hakattur, Exciting With Battery Supply Externally To The Field To Magnetise The Core, Testing Running The Dg, Checking Output & Parameters On Both Noload & On Exchange Load Etc As Reqd. , Replacement Of Damaged/ Burnt Dc Control Wiring From Starter To Ignition Board And To Dynamo With Suitable Copper Conductor Wires And Lugs Etc To Avoid Further Burning Of The Wiring Upon Starting Etc As Reqd. , Replacement Of Stator Winding Of 20Kva, 3Phase, 415 Volts Dg Set ( Against Burnt Winding ) I/C Dismantling Alternator, Taking It Out From The Canopy, Transportation Of Same From Hattihole To Near By Alternator Rewinding Shop To & From By Engaging A Suitable Transport Vehicle, Rewinding Of Stator With Suitable Copper Conductor, Varnishing, Prdg Rated Insulation, Baking, Physical Checks, Fixing Same To Alternator At Hattihole, Exciting With Battery Supply Externally To The Field To Magnetise The Core, Testing Running The Dg, Checking Output & Parameters On Both Noload & On Exchange Load Etc As Reqd. , B-Check Servicing Of Following Capacity Dg Set By Engaging Dg Mechanic By Utilising The Existing Consumables Like Oil, Filters Etc, Draining Out Of Engine Oil From The Sump, Filling New Oil, Replacing Fuel And Oil Filters, Oil Bath Type Air Filter, Tightening All The Bolts & Nuts To The Reqd Torque, General Check Up Of Working Parameters And Checking The V-Belt, Testng As Reqd. (Consumables Like Oil, Filters Will Be Paid Separately) , Supply Of The Following Consumables / Spares For The Engine During Servicing / Repair Works , Testing Complete As Required. Make :- Kirloskar/Volvoline/ Servo /Castrol/ Shell Simlr Supr Make & Grades. , Lube Oil Filter With O Ring. , Diesel Filters- Set Of 2 (Pre & Micro) With O Ring , Replacement Of V Belts Of Size A-28/A-32/ A-40 / A-46/ A-48/ A-49/ A-51 , S&F Of Hydraulic/ Metal Braided Flexible Fuel Pipe With Banjo Bolts & Copper Washers Etc. Up To 2½ Feet Long. , S&F Of Hydraulic/ Metal Braided Flexible Fuel Pipe With Banjo Bolts & Copper Washers Etc. 3 Feet To 5 Feet Long. , S&F Of Pvc Braided Flexible Fuel Pipe With Banjo Bolts & Copper Washers Etc. Up To Up To 2½ Feet Long. , S&F Of Pvc Braided Flexible Fuel Pipe With Banjo Bolts & Copper Washers Etc. 3 Feet To 5 Feet Long. , S&F Of Nozzle Return Pipe , S&F Of Oil Pressure Hose Pipe Of Suitable Length , Replacement Of Ignition Switch Unit Normally Open Type With Operating Key Suitable For Above Dg Sets I/C Making Connection, Checking Etc As Reqd. , Providing Self Adhessive Waterproof Sealing Black Tar Felt Asphalt Sheet/ Water Proof Sheet At The On The Roof/ Top Side Of Dg Set Canopy Of Size Apprx 2.5Mtrs X 1.5Mtrs To Avoid Seapage Of Rain Water Inside Canopy I/C Covering It Fully Leaving No Room For Rain Water Entry Inside With Associated Spares Complete Etc As Reqd. , S&F Of Counter Type Electrical Run Hour Meter Operating On 230V, 1 Ph, 50Hz, Ac Supply I/C Connecting To The Existing Power Cable With Necessary Terminations And Clamping If Required Etc As Reqd. (Make: Quartz//Krish/ Isi Approved) , Repair Of Faulty 12 Volts Dynamo Of Dg Set I/C Transportation To Work Shop To & From, Replacement Of Commutator, Set Of Carbon Brushes With Cutouts, Fixing The Same To The Dg Set And Testing, Checking The Output Voltage Complete Etc As Reqd. , Repair Of Faulty 12 Volts Starter Of Dg Set I/C Transportation To Work Shop To & From, Replacement Of Bentex, Rectifier, Set Of Bearings, Shaft Fixing The Same To The Dg Set And Testing, Checking The Output Voltage Complete Etc As Reqd. , Supply And Fixing The Electronic Type Automatic Voltage Controller Suitable For 15/20/40 Kva Capacity Alternator Etc As Reqd. Note [Optional Item, It May Be Supplied After Consent Of Sde/Jto(Ele @ Site) (Make : Oem/ Swastik Or Approved Make) , Supply And Fixing Battery Lead Of Size 25Sqmm Pvc Insulated Multistrand Single Core Copper Conductor Cable And Properly Bolted To Existing Terminal Etc As Reqd. , Supply And Fixing 2 Nos Brass Terminals For Battery Positive & Negetive Polarities With Bolts And Nuts Etc As Reqd. , Supply And Fixing Ms Wired 1 X 1 Welded Wire Mesh Of Following Sizes With Screws/ Nuts/ Bolts/ Washers Etc To Cover The Opened Portion At Flywheel Side/ Alternator Side To Avoid Rodent Entries/ Safety To The Operating Personal Etc As Reqd. , Dismantling The Radiator Assembly From Existing 15/20/30/40 Kva Capacity Dg Set, Servicing And De-Scaling The Radiator At Site, Water Wash, Flushing, Removing The Blockages If Any, Checking For The Leakages, Refixing The Radiator Assembly To The Dg With Its Accessories Etc As Reqd. , Supply & Fixing Of Radiator Hose Pipes (Straight/ Bent) Of Suitable Size, Thickness And Length With Ring/ Banjo Clamps To The Radiator Of 15/20/30/40 Kva Capacity Dg Set Etc As Reqd. , Complete Cleaning Of Upto 40Kva Existing Dg Set I/C Removing The Dust, Sticky Dirts, Sediments, Oil Spillages, Carbon Deposits With Existing Diesel/ Cleaning Agents Then Dry Cleaning, Then Painting With Enamelled Oil Paint Matching To Existing Colour, Finishing, Making It Neat Complete Etc As Reqd. , Supply & Fixing Of Ms Hinges To The Doors Of The Dg Canopy I/C Drilling, Fixing, Welding, Fabrication Work Complete Etc As Reqd. , Sitc Of 12 Volts, 10 Amps Battery Charger Smps Type To Charge Dg Set Batteries Suitable For Operation On 230 V, 50Hz Input Ac Supply Of Range 170V To 270V, Output 13.3V To 13.8Volts Dc, With Protections For Over Current, Over Charging, Reverse Polarity Complete With Power Supply Cable, Termination Points And Other Accessories Etc I/C Supply Of Heavy Duty Charging Crocodile Clips-2Nos Etc Complete As Reqd. (Make: Nhp Or Ss Make)
Basic Detail
Tender No GEM/2026/B/8264788
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 11 Nov 2026
Submission Date 24 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 4.65 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
6d986942-dcc0-4d92-b73e-a0335284bd25.pdf
1794399772.xlsx
1794399801.pdf
1794399814.pdf
1794399819.pdf
1794399824.pdf
ATC45_c999b210-581a-404d-82c91794400055592_EEEMGL.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
pdf

6d986942-dcc0-4d92-b73e-a0335284bd25.pdf

xlsx

1794399772.xlsx

pdf

1794399801.pdf

pdf

1794399814.pdf

pdf

1794399819.pdf

pdf

1794399824.pdf

pdf

ATC45_c999b210-581a-404d-82c91794400055592_EEEMGL.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender