Heavy Industries and Public Enterprises Government Departments Closing in 4 days TDR #58483506

Tender For Ambedhkar Grama Vikasana Padhathi - Valanji - Kulangarath - Lakham Veedu Colony - Thodannur Block Panchayath, Kuttyadi Lac-Miscellaneous Works

Issued by Government Departments · Kozhikode, Kerala
Tender Value
79.19 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
4 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Ambedhkar Grama Vikasana Padhathi - Valanji - Kulangarath - Lakham Veedu Colony - Thodannur Block Panchayath, Kuttyadi Lac-Miscellaneous Works- 1 House Repairing Of Purushu Valanji 2 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed. All Kinds Of Soil 3 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 4 13.16.16 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 5 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 500X500 Mm. 6 51.2 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 7 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 8 50.6.5.2 Hollow Block Masonry Using Pre Cast Blocks ( Factory Made) Of Size 40X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part 1 Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Etc Complete 9 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar 10 House Repairing Of Kothuruthi Kunjiraman Devi 11 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 12 5.22.6Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 13 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 14 5.1.2Providing And Laying And Position Reinforced Cement Concrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 15 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 16 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 17 5.9.1Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Ofcolumns, Etc For Mass Concrete 18 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 19 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 20 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 21 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 22 50.9.3.1 Providing And Fixing Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 30 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Paneling Which Will Be Paid For Separately, All Complete As Per Direction 0F Engineer In- Charge. Using Anjili/ Jack Wood 23 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 24 9.48.2 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings/ Wooden Frames With Rawl Plugs Screws Etc 25 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm.Delete Add Specification Below 26 House Repairing Of Kothuruthi Babu E T 27 50.6.7.2 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Super Structure Above Plinth Level Up To Floor Two Level Including All Cost Of Materials, Labour Charges Etc. 28 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 29 8.31 Providing And Fixing I St Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer -In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete 30 9.48.1Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding 31 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 32 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 House Repairing Of Kothuruthi Sasi 35 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 36 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 37 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Ofcorrugation As Approved By Engineer-In-Charge) 0.40 Mm (+0.05%), Total Coatedthickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side. Of The Sheet And Polyester Top Coat 15-18 Microns.Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratchesduring Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desiredby Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Ofsize (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Orcurved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting Tosize And Shape Wherever Required. 38 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 39 House Repairing Of Kothuruthi Kothuruthi Mini 40 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 41 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 42 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 43 51.20Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 44 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm 45 House Repairing Of Kulangarath Damodharan 46 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 47 50.9.3.1 Providing And Fixing Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 30 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Paneling Which Will Be Paid For Separately, All Complete As Per Direction 0F Engineer In- Charge. Using Anjili/ Jack Wood 48 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 49 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 50 22.6Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) After Surface Preparation, First Layer Of Slurry Of Cement @ 0.488 Kg/ Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/ Sqm. Laying Second Layer Of Fibre Glass Cloth When The First Layer Is Still Green. Overlaps Of Joints Of Fibre Cloth Should Not Be Less Than 10 Cm. C) Third Layer Of 1.5 Mm Thickness Consisting Of Slurry Of Cement @ 1.289 Kg/ Sqm Mixed With Water Proofing Cement Compound @ 0.670 Kg/Sqm And Coarse Sand @ 1.289 Kg/Sqm. This Will Be Allowed To Air Cure For 4 Hours Followed By Water Curing For 48 Hours. The Entire Treatment Will Be Taken Upto 30 Cm On Parapet Wall And Tucked Into Groove In Parapet All Around. D) Fourth And Final Layer Of Brick Tilling With Cement Mortar (Which Will Be Paid For Separately. For The Purpose Of Measurement The Entire Treated Surface Will Be Measured)Delete Add Specification Below 51 9.48.2 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings/ Wooden Frames With Rawl Plugs Screws Etc 52 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 53 House Repairing Of - Sujil Lal 54 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 55 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 56 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm 57 House Repairing Of - Valanji Surendran 58 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 59 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 60 50.6.7.2 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Super Structure Above Plinth Level Up To Floor Two Level Including All Cost Of Materials, Labour Charges Etc. 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 64 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 65 House Repairing Of Kulangarath Kunjiraman 66 15.23.1 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 67 15.14.1 Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead: Of Sectional Area 40 Square Centimetres And Above 68 15.31 Dismantling Tiled Roofing With Battens, Boarding Etc. Complete Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. 69 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 70 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 71 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 72 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 73 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete 74 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 75 House Repairing Of - Valanji Aandi 76 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 77 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 79 House Repairing Of - Valanji Baiju 80 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 81 House Repairing Of Valanji Kunjiraman Madhavi 82 13.1.112 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 83 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 84 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 85 5.9.6Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 86 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 87 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 88 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 89 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 90 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface: Water Thinnable Cement Primer 91 House Repairing Of Valanji Kumaran 92 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 93 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 94 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.Delete Add Specification Below 95 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 96 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 97 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 98 House Repairing Of Valanji Rajan 99 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 100 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 101 10.25.2 Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 102 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 103 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm.Deleteadd Specification Below 104 50.2.3.1 Pumping Or Bailing Out Water And Removing Slush Etc By Using Pump Set Including Cost Of Labour, Oil Hire Charges Of Pumpset, Etc Complete 105 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 106 House Repairing Of- Raveendran Kandiyil 107 60.2.3 Bailing Out Water Using Pump Above 5 Hp And Up To 10 Hp-Bailing Out Water With Engine And Pump Set Above 5Hp And Up To 10Hp, Including Conveyance To Site And Erection,Cost Of Fuel, Lubrication Oil And Other Stores, Pay Of Staff Etc Complete 108 100.3.1.15 Earthwork Open Well Excavation (In Or Under Water) For Wells Of Dia. Upto 2.50 M In All Kinds Of Soil And Conveying And Depositing The Spoil Within Initial Lead Of 50M And Lift From 6.0M To 7.5M Including Neat Banking. New Data (Prepared Based On Phed Sdb - Item No.1073 & 1076 109 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 110 House Repairing Of- Sathyan Kulangarath 111 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 112 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 113 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 114 House Repairing Of Kunjiraman O T 115 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 116 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 117 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 118 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 119 50.9.3.1 Providing And Fixing Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 30 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Paneling Which Will Be Paid For Separately, All Complete As Per Direction 0F Engineer In- Charge. Using Anjili/ Jack Wood 120 House Repairing Of- Shivadasan Kulangarath 121 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 122 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 123 5.9.1Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Ofcolumns, Etc For Mass Concrete 124 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 125 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 126 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 127 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 128 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 129 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 130 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 131 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 132 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 133 House Repairing Of Dineshan Kulangarath 134 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 135 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 136 8.31 Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 137 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 138 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 139 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 140 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 141 House Repairing Of- Valanji Rajeevan 142 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 143 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 144 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 145 House Repairing Of-- Kunjiraman Elathuruthi 146 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 147 13.16.1 6 Mm Cement Plaster Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) 148 11.40 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer) Of Ist Quality Conforming To Is: 15622 Of Approved Make In All Colours, Shades, Except White, Ivory, Grey Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. 149 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 150 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work 151 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 152 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 153 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 154 House Repairing Of-- Babu Kulangarath 155 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 156 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 157 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 158 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 159 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide 160 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 161 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 162 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Ofcorrugation As Approved By Engineer-In-Charge) 0.40 Mm (+0.05%), Total Coatedthickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side. Of The Sheet And Polyester Top Coat 15-18 Microns.Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratchesduring Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desiredby Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Ofsize (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Orcurved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting Tosize And Shape Wherever Required. 163 Repairing Of Well -( 1)Valanji Gopalan 164 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed.All Kinds Of Soil 165 50.2.3.1 Pumping Or Bailing Out Water And Removing Slush Etc By Using Pump Set Including Cost Of Labour, Oil Hire Charges Of Pumpset, Etc Complete 166 100.3.1.13 Earthwork Open Well Excavation (In Or Under Water) For Wells Of Dia. Upto 2.50 M In All Kinds Of Soil And Conveying And Depositing The Spoil Within Initial Lead Of 50M And Lift From 3.0M To 4.5M Including Neat Banking.New Data (Prepared Based On Phed Sdb - Item No.1073 & 1076 167 13.7.2 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 168 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 169 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 170 Repairing Of Well -( 2) Kothuruthi Narayanan 171 50.2.3.1 Pumping Or Bailing Out Water And Removing Slush Etc By Using Pump Set Including Cost Of Labour, Oil Hire Charges Of Pumpset, Etc Complete 172 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 173 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 174 10.25.2 Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 175 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed.All Kinds Of Soil 176 Samskarika Nilayam 177 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 178 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level: 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size) 179 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size 180 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 181 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 182 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 183 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 184 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 185 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 186 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide 187 5.9.19 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Weather Shade, Chajjas, Corbels Etc., Including Edges 188 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 189 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete 190 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 191 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 192 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 193 13.4.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Coarse Sand) 194 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface: Water Thinnable Cement Primer 195 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work 196 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work 197 9.48.1 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding 198 21.1.1.3 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpolyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron ) 199 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Polyester Powder Coated Aluminium (Minimum Thickness Of Polyester Powder Coating 50 Micorn) 200 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness 201 11.37A Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 202 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 203 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 204 10.17 Providing And Fixing M.S. Fan Clamp Type I Or Ii Of 16 Mm Dia M.S. Bar, Bent To Shape With Hooked Ends In R.C.C. Slabs Or Beams During Laying, Including Painting The Exposed Portion Of Loop, All As Per Standard Design Complete. 205 10.25.2 Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 206 50.17.1.4 Supplying And Fixing Cp Health Faucet Good Quality Including Cost Of Materials And Labour Charges Etc. Complete As Per The Direction Of Site Engineer-In-Charge. 207 17.2.1 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked White Solid Plastic Seat And Lid Add Specification Below 208 17.7.4 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Flat Back Wash Basin Size 550X400Mm With Single 15 Mm C.P.Brass Pillar Taps 209 18.48Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 210 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore 211 18.58.1.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour.Circular Type 100 Mm Nominal Dia 212 50.18.7.4.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall 213 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm2 214 50.18.9.9.2 Providing And Fixing Pvc Pipes Includes Joints Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 110 Mm Dia 4 Kg/Cm2 215 17.28.1.1 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc. Waste Fittings Complete.Semi Rigid Pipe 32 Mm Dia 216 9.145 Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm) Both Vertical Sides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm ) And 75 Mmx 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 217 50.17.1.3 Supplying And Fixing Cp Towel Rod 60Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 218 51.19.St3 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately)3. 25 To Below 35 Flush Capacity 219 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 220 50.18.9.13.2 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 10 Kgf/Cm2- External Work - Exposed On Wall 221 50.18.9.14.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10 Kgf/Cm2 - External Work- Exposed On Wall 222 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 223 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 224 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 225 50.18.9.22.8 Providing And Fixing Pvc Moulded Fittings /Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia Vent Cowl 226 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site 227 4.1.4 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level: 1:2:4 )1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 40 Mm Nominal Size) 228 50.2.26.1 Filling With Contractor Own Earth (Excluding Rock) In Open Areas In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge. 229 50.2.26.1 Filling With Contractor Own Earth (Excluding Rock) In Open Areas In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge. 230 16.91.2 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-30 Grade With Approved Color Design And Pattern.. 231 51.2.3 Filling With Quarry Muckfilling Up Low Lying And Water Logged Areas With Local Material/ Quarry Muck, Spreading In Layers, Leveling The Top At Site And Consolidation By Ramming, Etc Complete For Improving The Cbr Value Of Subgrade 232 10.5.2 Providing And Fixing 1 Mm Thick M.S. Sheet Door With Frame Of 40X40X6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using Flats 30X6 Mm For Diagonal Braces And Central Cross Piece 233 11.20.4 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand).Ordinary Cement Without Any Pigment 234 50.12.2.1 Providing & Fixing Poly Carbonate Corrugated Sheet 0.8 Mm Thick As Approved By The Engineer In Charge And Should Be Supplied In A Single Length Of 12 M Or As Decide By The Engineer In Charge. The Sheets Shall Be Fixed Using Self Drilling / Self Tapping Screw Of Size (5.5X55 Mm) With Epdm Seal Complete Upto Any Pitch In Horizontal/ Vertical/ Curved Surface, But Excluding The Cost Of Purlins, Rafters, Trusses, And Including Cutting To Size Shapes Where Ever Required. 235 50.9.15.1 Supplying And Fixing 200 Mm Aluminium Aldrop 236 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 237 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 238 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 239 17.60.2.3Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating Without Vent Arm Complete,100 Mm Inlet And 75 Mm Outle Thubless Centrifugally Cast (Spun) Iron Epoxy Coated Inside & Outside As Per Is:15905 Including Cost Of Cutting And Making Good The Walls And Floors: 240 18.58.2.1Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid 150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 241 21.12.2 Providing And Fixing Aluminium Tubular Handle Bar 32 Mm Outer Dia, 3.0Mm Thick & 2100 Mm Long With S.S. Screws Etc. Complete As Per Direction Of Engineer -In-Charge.Powder Coated Minimum Thickness 50 Micron Aluminium Tubular Handle Bar 242 21.13Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete 243 Od37112/2025_2026Fabrication ,Supply, Conveyance & Installation Of Granite Name Board Indicating The Cost Involved, The Commencement, Completion And Inauguration Date Etc 244 Od35639/2025_2026 Multy Wood Panel Letters-Providing And Installing Name Board & Letters 15 To 25Cm Height Using Multi Wood Panel 17Mm Average Thickness, Design As Per The Departmental Approved Drawing( E/M ), Including All Cost Of Materials , Jigsaw Cutting Charges ,All Labour Charges And Conveyance Etc Complete 245 1.27.6 : Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.12 Module (200Mmx150Mm) 246 1.10.2 : Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 247 1.10.1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group A 248 1.10.3Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 249 1.24.4 : Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet 250 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 251 1.14.2Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 252 1.14.3Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 253 1.21.1Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 254 1.28.1Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.1 Or 2 Module 255 1.28.2Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.3 Module 256 1.28.3 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.4 Module 257 1.28.4Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.6 Module 258 1.28.5Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.8 Module 259 1.24.1Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amps Switch 260 1.24.2Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.2 Way 5/6 Amps Switch 261 1.24.3Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6Pin15/16 Amp Switch 262 1.24.5Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 263 2.5.3Supplying And Fixing Of Following Ways Surface/ Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting McbS (But Without McbS And Incomer ) As Required .(Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required.)12 Way (4 + 36), Double Door 264 2..13.1Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 265 2.15.2Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 266 5.2Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required 267 1.58Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. 268 1.27.4 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module (200Mmx75Mm) 269 1.27.3 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.4 Module (125Mmx75Mm) 270 2.10.3 Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, \C\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Double Pole 271 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 272 Od377496/2022_2023 Supply Of Ceiling Fan 1200 Mm Sweep, 230V, 1Ph, 5 Star Rated Complete With Double Ball Bearing, Motor Blades, Down Rods, Canopy, Capacitor Etc Complete As Required. (Crompton Asset 50 - 5 Star / Usha Technix Flair / Orient Energy Star). 273 1.45 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standardlength (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable,Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. 274 Od378443/2022_2023 Supply And Installation Of 18 W Led Tube Light (Havells/Philips/Equivalent Make) 275 Od378444/2022_2023 : Supply And Installation Of 9W Led Bulb(Philips/Crompton/Havells/Equivalent) 276 Footpath To O T Kunjiraman House 277 3.5.1 Excavation In Cutting In Soil By Manual Means With Lead Upto 50 Mexcavation For Roadway In Soil Using Manual Means For Carrying Of Cut Earth To Embankment Site With A Lift Upto 1.5 M And Lead Upto 50 M As Per Technical Specification Clause 302.3 278 51.2.3Filling With Quarry Muckfilling Up Low Lying And Water Logged Areas With Local Material/ Quarry Muck, Spreading In Layers, Leveling The Top At Site And Consolidation By Ramming, Etc Complete For Improving The Cbr Value Of Subgrade 279 11.4.3.1 Providing Concrete For Plain/Reinforced Concrete In Open Foundations Complete As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 Iii. P.C.C. Grade M 20 (I) Nominal Mix (1:2:4) 280 Footpath To Damodharan House 281 3.5.1 Excavation In Cutting In Soil By Manual Means With Lead Upto 50 Mexcavation For Roadway In Soil Using Manual Means For Carrying Of Cut Earth To Embankment Site With A Lift Upto 1.5 M And Lead Upto 50 M As Per Technical Specification Clause 302.3 282 51.2.3Filling With Quarry Muckfilling Up Low Lying And Water Logged Areas With Local Material/ Quarry Muck, Spreading In Layers, Leveling The Top At Site And Consolidation By Ramming, Etc Complete For Improving The Cbr Value Of Subgrade 283 11.4.3.1 Providing Concrete For Plain/Reinforced Concrete In Open Foundations Complete As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203Iii. P.C.C. Grade M 20 (I) Nominal Mix (1:2:4) 284 Footpath To Babu Kulangarath House 285 3.5.1 Excavation In Cutting In Soil By Manual Means With Lead Upto 50 M Excavation For Roadway In Soil Using Manual Means For Carrying Of Cut Earth To Embankment Site With A Lift Upto 1.5 M And Lead Upto 50 M As Per Technical Specification Clause 302.3 286 51.2.3Filling With Quarry Muckfilling Up Low Lying And Water Logged Areas With Local Material/ Quarry Muck, Spreading In Layers, Leveling The Top At Site And Consolidation By Ramming, Etc Complete For Improving The Cbr Value Of Subgrade 287 11.4.3.1 Providing Concrete For Plain/Reinforced Concrete In Open Foundations Complete As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203Iii. P.C.C. Grade M 20 (I) Nominal Mix (1:2:4) 288 Protection Wall To House Of Acharambath Sureshbabu 289 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 290 4.1.6 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) 291 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site 292 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 293 5.22A.2 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Hard Drawn Steel Wire 294 4.3.2 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For:Retaining Walls, Return Walls, (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses Fillets, Kerbs And Steps Etc. 295 Providing Pipe Line For Homes 296 2.8.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 297 19.19.1.1Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality.L D - 2.5 Rectangular Shape 600X450 Mm Internal Dimensions 298 50.18.8.6.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 10 Kgf/Cm2 299 Solar Light 300 Od37116/2025_2026Supply And Installation Of 6 M Gi Pole With 24 W Led Luminary Light With Integrated Lithium Phosphate Battery, 75W Solar Panel For Better Performance, Erection And Commissioning Etc., All Complete. 301 Roads 302 (Od Derived From Mord3.15.2)Compacting Original Ground (Ii) Compacting Original Ground Supporting Subgrade Loosening Of The Ground Upto A Level Of 300 Mm Below The Subgrade Level, Watered, Graded And Compacted In Layers To Meet Requirement Of Tables 300.1 And 300.2 For Subgrade Construction As Per Technical Specification Clause 303.5.2. 303 16.78.3 Construction Of Granular Sub- Base By Providing Close Graded Material Conforming To Specifications, Mixing In A Mechanical Mix Plant At Omc, Carriage Of Mixed Material By Tippers To Work Site, For All Leads & Lifts, Spreading In Uniform Layers Of Specified Thickness With Motor Grader On Prepared Surface And Compacting With Vibratory Power Roller To Achieve The Desired Density, Complete As Per Specifications And Directions Of Engineer-In- Charge.With Material Conforming To Grade - Iii ( Size Range 26.5 Mm To 0.075 Mm) Having Cbr Value - 20 304 16.79 Providing , Laying Spreading And Compacting Graded Stone Aggregate ( Size Range 53 Mm To 0.075 Mm) To Wet Mix Macadam (Wmm) Specification Including Premixing The Material With Water At Omc In Mechanical Mix Plant, Carriage Of Mixed Material By Tipper To Site, For All Leads & Lifts, Laying In Uniform Layers With Mechanical Paver Finisher In Sub - Base / Base Course On Well Prepared Surface And Compacting With Vibratory Roller Of 8 To 10 Tonne Capacity To Achieve The Desired Density, Complete As Per Specifications And Directions Of Engineer - In- Charge. 305 51.16.Pc.1Primer Coat - Bitumen Emulsion (Ss-1) - Using Packed Bitumen Rates Providing And Applying Primer Coat With Bitumen Emulsion (Ss-1) On Prepared Surface Of Granular Base Including Cleaning Of Road Surface And Spraying Primer At The Rate Of 0.70 - 1.0 Kg/Sqm Using Mechanical Means As Per Technical Specification Clause 502 (Low Porosity). 306 51.16.31.1.3Pb Tack Coat - Rs Bitumen Emulsion - Using Packed Bitumen Rates Providing And Applying Tack Coat With Bitumen Emulsion (Rs-1) Using Emulsion Distributor At The Rate Of 0.25 To 0.30 Kg Per Sqm On The Prepared Granular Surfaces Treated With Primer & Cleaned With Hydraulic Broom As Per Technical Specification Clause 503. 307 (Od Derived From Mord 75.5.11.1.A.2Pb ) Mix Seal Surfacing - Manual Means - Type A - Bitumen S-65 - Packed Bitumen Rates Providing, Laying And Rolling Of Close-Graded Premix Surfacing Material Of 20 Mm Thickness Composed Of 11.2 Mm To 0.9 Mm (Type-A) Or 13.2 Mm To 0.9 Mm (Type-B) Aggregates Using Penetration Grade Bitumen To Required Line, Grade And Level To Serve As Wearing Course On A Previously Prepared Base, Including Mixing In A Suitable Plant, Laying And Rolling With A Three Wheel 8-10 Kn Static Roller And Finishing To Required Level And Grades As Per Technical Specification Clause 509 By Manual Meanstype A (Ii) Bitumen (S-65),Including Supplying And Stacking Of Materials.

BOQ

Name of Work:- Ambedhkar Grama Vikasana Padhathi - Valanji - Kulangarath - Lakham Veedu Colony - Thodannur Block Panchayath, Kuttyadi LAC
Sl. No. Item Description
1House Repairing of Purushu Valanji
22.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil
313.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
413.16.16 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
511.41.1 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.
651.2 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
710.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
850.6.5.2 Hollow block masonry using pre cast blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part 1 of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
915.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. In cement mortar
10House Repairing of Kothuruthi Kunjiraman Devi
112.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
125.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
13Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
145.1.2providing and laying and position Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
155.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
165.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
175.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases ofcolumns, etc for mass concrete
185.9.6 Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
1913.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
2013.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
2150.9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
2250.9.3.1 Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
2350.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
249.48.2 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc
2511.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.Delete Add Specification Below
26House Repairing of Kothuruthi Babu E T
2750.6.7.2 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
2850.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
298.31 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
309.48.1Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
3113.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
3213.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
3311.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
34House Repairing of Kothuruthi Sasi
3513.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
3610.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
3751.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.40 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required.
3811.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
39House Repairing of Kothuruthi Kothuruthi Mini
4050.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
4113.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
4210.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
4351.20Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
4411.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm
45House Repairing of Kulangarath Damodharan
4650.9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
4750.9.3.1 Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
4851.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
4910.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
5022.6Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)Delete Add Specification Below
519.48.2 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc
5211.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.
53House Repairing of - Sujil Lal
5413.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
5513.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
5611.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm
57House Repairing of - Valanji Surendran
5813.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
5913.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
6050.6.7.2 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
615.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
625.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
635.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
645.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
65House Repairing of Kulangarath Kunjiraman
6615.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
6715.14.1 Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead: Of sectional area 40 square centimetres and above
6815.31 Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
695.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
705.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
715.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
7213.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
7350.6.1.8 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
7411.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.
75House Repairing of - Valanji Aandi
7613.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
77Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
7811.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.
79House Repairing of - Valanji Baiju
8011.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.
81House Repairing of Valanji Kunjiraman Madhavi
8213.1.112 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
8313.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
842.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
855.9.6Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
865.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
875.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
8810.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
8951.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
9013.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
91House Repairing of Valanji Kumaran
9213.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
9313.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
9451.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Delete Add Specification Below
9510.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
9650.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
9711.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.
98House Repairing of Valanji Rajan
9913.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
10013.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
10110.25.2 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10251.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
10311.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.DeleteAdd Specification Below
10450.2.3.1 Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
10550.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
106House Repairing of- Raveendran Kandiyil
10760.2.3 Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
108100.3.1.15 Earthwork open well excavation (in or under water) for wells of dia. upto 2.50 m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 6.0m to 7.5m including neat banking. NEW DATA (Prepared based on PHED SDB - Item No.1073 & 1076
10950.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
110House Repairing of- Sathyan Kulangarath
11113.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
11213.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
11311.41.1 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm.
114House Repairing of Kunjiraman O T
11513.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
11613.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
11711.41.1 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm.
11850.9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
11950.9.3.1 Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
120House Repairing of- Shivadasan Kulangarath
1212.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1225.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
1235.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases ofcolumns, etc for mass concrete
1245.9.6 Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
1255.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
1265.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
1275.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
1285.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
12950.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13013.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13113.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13211.41.1 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm.
133House Repairing of Dineshan Kulangarath
13411.41.1 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm.
13550.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
1368.31 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
13710.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
13851.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
13913.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
14013.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
141House Repairing of- Valanji Rajeevan
14213.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
14313.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
14411.41.1 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm.
145House Repairing of-- Kunjiraman Elathuruthi
14613.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
14713.16.1 6 mm cement plaster of mix: 1:3 ( 1 cement : 3 fine sand)
14811.40 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
14913.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
15013.60.1 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
15117.9.1 Providing and fixing kitchen sink with C. I brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x250 mm
15210.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
15351.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
154House Repairing of-- Babu Kulangarath
15550.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
1565.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
1575.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
1585.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
1595.9.16.1 Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
1605.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
16110.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
16251.20 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.40 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required.
163Repairing of Well -( 1)Valanji Gopalan
1642.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
16550.2.3.1 Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
166100.3.1.13 Earthwork open well excavation (in or under water) for wells of dia. upto 2.50 m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 3.0m to 4.5m including neat banking.NEW DATA (Prepared based on PHED SDB - Item No.1073 & 1076
16713.7.2 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 ( 1 cement : 4 fine sand)
16810.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
16950.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
170Repairing of Well -( 2) Kothuruthi Narayanan
17150.2.3.1 Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
17250.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
17313.1.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
17410.25.2 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
1752.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
176Samskarika Nilayam
1772.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1784.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
1795.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
1805.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
1815.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
1825.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
1835.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
1845.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
1855.9.6 Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
1865.9.16.1 Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
1875.9.19 Centering and shuttering including strutting, etc. and removal of form for: Weather shade, Chajjas, corbels etc., including edges
1885.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
18950.6.1.8 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
19050.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
19150.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
19213.16.1 6 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
19313.4.1 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)
19413.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
19513.60.1 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
19613.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
1979.48.1 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
19821.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
199For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn)
20021.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
20111.37A Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
20211.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete
20311.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
20410.17 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
20510.25.2 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
20650.17.1.4 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
20717.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid Add Specification Below
20817.7.4 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps
20918.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
21018.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
21118.58.1.1 Providing and fixing PTMT grating of approved quality and colour.Circular type 100 mm nominal dia
21250.18.7.4.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
21350.18.9.7.1 Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
21450.18.9.9.2 Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
21517.28.1.1 Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe 32 mm dia
2169.145 Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm) Both vertical sides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm ) and 75 mmx 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer-in-charge.
21750.17.1.3 Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
21851.19.ST3 Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)3. 25 to below 35 flush capacity
21950.18.9.3.2 Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2
22050.18.9.13.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
22150.18.9.14.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
22250.18.9.22.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
22350.18.9.22.2 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
22450.18.9.22.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
22550.18.9.22.8 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
22660.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
2274.1.4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
22850.2.26.1 Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
22950.2.26.1 Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
23016.91.2 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern..
23151.2.3 Filling with Quarry MuckFilling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
23210.5.2 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece
23311.20.4 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Ordinary cement without any pigment
23450.12.2.1 Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required.
23550.9.15.1 Supplying and fixing 200 mm Aluminium aldrop
23650.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
23750.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
23810.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
23917.60.2.3Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete,100 mm inlet and 75 mm outle tHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 including cost of cutting and making good the walls and floors:
24018.58.2.1Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating
24121.12.2 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Powder coated minimum thickness 50 micron aluminium tubular handle bar
24221.13Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
243od37112/2025_2026Fabrication ,supply, conveyance & installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc
244od35639/2025_2026 MULTY WOOD PANEL LETTERS-Providing and installing Name Board & Letters 15 to 25cm height using multi wood panel 17mm average thickness, design as per the departmental approved drawing( E/M ), including all cost of materials , jigsaw cutting charges ,all labour charges and conveyance etc complete
2451.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
2461.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
2471.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
2481.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
2491.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
2501.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
2511.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2521.14.3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2531.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
2541.28.1Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
2551.28.2Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
2561.28.3 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
2571.28.4Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
2581.28.5Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
2591.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
2601.24.2Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch
2611.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6pin15/16 amp switch
2621.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2632.5.3Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door
2642..13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2652.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2665.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
2671.58Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2681.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2691.27.3 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
2702.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2712.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
272od377496/2022_2023 Supply of ceiling fan 1200 mm sweep, 230V, 1Ph, 5 star rated complete with double ball bearing, motor blades, down rods, canopy, capacitor etc complete as required. (Crompton Asset 50 - 5 star / Usha Technix Flair / Orient Energy Star).
2731.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
274od378443/2022_2023 Supply and Installation of 18 W LED tube light (Havells/Philips/Equivalent make)
275od378444/2022_2023 : Supply and Installation of 9W LED bulb(Philips/Crompton/Havells/equivalent)
276Footpath to O T Kunjiraman House
2773.5.1 Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
27851.2.3Filling with Quarry MuckFilling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
27911.4.3.1 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 III. P.C.C. grade M 20 (i) Nominal mix (1:2:4)
280Footpath to Damodharan House
2813.5.1 Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
28251.2.3Filling with Quarry MuckFilling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
28311.4.3.1 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203III. P.C.C. grade M 20 (i) Nominal mix (1:2:4)
284Footpath to Babu Kulangarath House
2853.5.1 Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
28651.2.3Filling with Quarry MuckFilling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
28711.4.3.1 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203III. P.C.C. grade M 20 (i) Nominal mix (1:2:4)
288Protection wall to house of Acharambath Sureshbabu
2892.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2904.1.6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
29160.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
2925.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
2935.22A.2 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Hard drawn steel wire
2944.3.2 Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
295Providing Pipe Line for Homes
2962.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
29719.19.1.1Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of required shape and approved quality.L D - 2.5 Rectangular shape 600x450 mm internal dimensions
29850.18.8.6.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2
299Solar Light
300od37116/2025_2026Supply and Installation of 6 m GI pole with 24 W LED luminary Light with Integrated Lithium phosphate battery, 75W Solar panel for better performance, erection and commissioning etc., all complete.
301Roads
302(OD Derived from MORD3.15.2)Compacting Original Ground (ii) Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.
30316.78.3 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20
30416.79 Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
30551.16.PC.1Primer Coat - Bitumen Emulsion (SS-1) - Using Packed Bitumen Rates Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 (low porosity).
30651.16.31.1.3pb Tack Coat - RS Bitumen Emulsion - Using Packed Bitumen Rates Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
307(OD Derived from MORD 75.5.11.1.A.2pb ) Mix Seal Surfacing - Manual Means - Type A - Bitumen S-65 - Packed Bitumen Rates Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 By Manual MeansType A (II) Bitumen (S-65),including supplying and stacking of materials.
308(OD Derived from MORD 75.8.1.1.A ) Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate: 4 course aggregate) laid to required slope as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58483506
AUTHORITY Government Departments
TENDER VALUE 79.19 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name Steel Industrials Kerala Limited
Work Description Tender For Ambedhkar Grama Vikasana Padhathi - Valanji - Kulangarath - Lakham Veedu Colony - Thodannur Block Panchayath, Kuttyadi Lac-Miscellaneous Works- 1 House Repairing Of Purushu Valanji 2 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed. All Kinds Of Soil 3 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 4 13.16.16 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 5 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 500X500 Mm. 6 51.2 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 7 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 8 50.6.5.2 Hollow Block Masonry Using Pre Cast Blocks ( Factory Made) Of Size 40X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part 1 Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Etc Complete 9 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar 10 House Repairing Of Kothuruthi Kunjiraman Devi 11 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 12 5.22.6Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 13 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 14 5.1.2Providing And Laying And Position Reinforced Cement Concrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 15 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 16 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 17 5.9.1Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Ofcolumns, Etc For Mass Concrete 18 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 19 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 20 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 21 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 22 50.9.3.1 Providing And Fixing Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 30 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Paneling Which Will Be Paid For Separately, All Complete As Per Direction 0F Engineer In- Charge. Using Anjili/ Jack Wood 23 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 24 9.48.2 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings/ Wooden Frames With Rawl Plugs Screws Etc 25 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm.Delete Add Specification Below 26 House Repairing Of Kothuruthi Babu E T 27 50.6.7.2 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Super Structure Above Plinth Level Up To Floor Two Level Including All Cost Of Materials, Labour Charges Etc. 28 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 29 8.31 Providing And Fixing I St Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer -In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete 30 9.48.1Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding 31 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 32 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 House Repairing Of Kothuruthi Sasi 35 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 36 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 37 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Ofcorrugation As Approved By Engineer-In-Charge) 0.40 Mm (+0.05%), Total Coatedthickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side. Of The Sheet And Polyester Top Coat 15-18 Microns.Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratchesduring Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desiredby Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Ofsize (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Orcurved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting Tosize And Shape Wherever Required. 38 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 39 House Repairing Of Kothuruthi Kothuruthi Mini 40 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 41 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 42 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 43 51.20Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 44 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm 45 House Repairing Of Kulangarath Damodharan 46 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 47 50.9.3.1 Providing And Fixing Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 30 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Paneling Which Will Be Paid For Separately, All Complete As Per Direction 0F Engineer In- Charge. Using Anjili/ Jack Wood 48 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 49 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 50 22.6Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) After Surface Preparation, First Layer Of Slurry Of Cement @ 0.488 Kg/ Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/ Sqm. Laying Second Layer Of Fibre Glass Cloth When The First Layer Is Still Green. Overlaps Of Joints Of Fibre Cloth Should Not Be Less Than 10 Cm. C) Third Layer Of 1.5 Mm Thickness Consisting Of Slurry Of Cement @ 1.289 Kg/ Sqm Mixed With Water Proofing Cement Compound @ 0.670 Kg/Sqm And Coarse Sand @ 1.289 Kg/Sqm. This Will Be Allowed To Air Cure For 4 Hours Followed By Water Curing For 48 Hours. The Entire Treatment Will Be Taken Upto 30 Cm On Parapet Wall And Tucked Into Groove In Parapet All Around. D) Fourth And Final Layer Of Brick Tilling With Cement Mortar (Which Will Be Paid For Separately. For The Purpose Of Measurement The Entire Treated Surface Will Be Measured)Delete Add Specification Below 51 9.48.2 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings/ Wooden Frames With Rawl Plugs Screws Etc 52 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 53 House Repairing Of - Sujil Lal 54 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 55 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 56 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm 57 House Repairing Of - Valanji Surendran 58 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 59 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 60 50.6.7.2 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Super Structure Above Plinth Level Up To Floor Two Level Including All Cost Of Materials, Labour Charges Etc. 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 64 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 65 House Repairing Of Kulangarath Kunjiraman 66 15.23.1 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 67 15.14.1 Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead: Of Sectional Area 40 Square Centimetres And Above 68 15.31 Dismantling Tiled Roofing With Battens, Boarding Etc. Complete Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. 69 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 70 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 71 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 72 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 73 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete 74 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 75 House Repairing Of - Valanji Aandi 76 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 77 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 79 House Repairing Of - Valanji Baiju 80 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 81 House Repairing Of Valanji Kunjiraman Madhavi 82 13.1.112 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 83 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 84 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 85 5.9.6Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 86 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 87 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 88 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 89 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 90 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface: Water Thinnable Cement Primer 91 House Repairing Of Valanji Kumaran 92 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 93 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 94 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.Delete Add Specification Below 95 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 96 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 97 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 98 House Repairing Of Valanji Rajan 99 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 100 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 101 10.25.2 Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 102 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 103 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm.Deleteadd Specification Below 104 50.2.3.1 Pumping Or Bailing Out Water And Removing Slush Etc By Using Pump Set Including Cost Of Labour, Oil Hire Charges Of Pumpset, Etc Complete 105 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 106 House Repairing Of- Raveendran Kandiyil 107 60.2.3 Bailing Out Water Using Pump Above 5 Hp And Up To 10 Hp-Bailing Out Water With Engine And Pump Set Above 5Hp And Up To 10Hp, Including Conveyance To Site And Erection,Cost Of Fuel, Lubrication Oil And Other Stores, Pay Of Staff Etc Complete 108 100.3.1.15 Earthwork Open Well Excavation (In Or Under Water) For Wells Of Dia. Upto 2.50 M In All Kinds Of Soil And Conveying And Depositing The Spoil Within Initial Lead Of 50M And Lift From 6.0M To 7.5M Including Neat Banking. New Data (Prepared Based On Phed Sdb - Item No.1073 & 1076 109 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 110 House Repairing Of- Sathyan Kulangarath 111 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 112 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 113 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 114 House Repairing Of Kunjiraman O T 115 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 116 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 117 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 118 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 119 50.9.3.1 Providing And Fixing Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 30 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Paneling Which Will Be Paid For Separately, All Complete As Per Direction 0F Engineer In- Charge. Using Anjili/ Jack Wood 120 House Repairing Of- Shivadasan Kulangarath 121 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 122 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 123 5.9.1Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Ofcolumns, Etc For Mass Concrete 124 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 125 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 126 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 127 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 128 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 129 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 130 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 131 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 132 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 133 House Repairing Of Dineshan Kulangarath 134 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 135 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 136 8.31 Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 137 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 138 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 139 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 140 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 141 House Repairing Of- Valanji Rajeevan 142 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 143 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 144 11.41.1 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 500X500 Mm. 145 House Repairing Of-- Kunjiraman Elathuruthi 146 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 147 13.16.1 6 Mm Cement Plaster Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) 148 11.40 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer) Of Ist Quality Conforming To Is: 15622 Of Approved Make In All Colours, Shades, Except White, Ivory, Grey Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. 149 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 150 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work 151 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 152 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 153 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.35 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Up To 12 Meter Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 154 House Repairing Of-- Babu Kulangarath 155 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 156 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 157 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 158 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 159 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide 160 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 161 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 162 51.20 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Ofcorrugation As Approved By Engineer-In-Charge) 0.40 Mm (+0.05%), Total Coatedthickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side. Of The Sheet And Polyester Top Coat 15-18 Microns.Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratchesduring Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desiredby Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Ofsize (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Orcurved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting Tosize And Shape Wherever Required. 163 Repairing Of Well -( 1)Valanji Gopalan 164 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed.All Kinds Of Soil 165 50.2.3.1 Pumping Or Bailing Out Water And Removing Slush Etc By Using Pump Set Including Cost Of Labour, Oil Hire Charges Of Pumpset, Etc Complete 166 100.3.1.13 Earthwork Open Well Excavation (In Or Under Water) For Wells Of Dia. Upto 2.50 M In All Kinds Of Soil And Conveying And Depositing The Spoil Within Initial Lead Of 50M And Lift From 3.0M To 4.5M Including Neat Banking.New Data (Prepared Based On Phed Sdb - Item No.1073 & 1076 167 13.7.2 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 168 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 169 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 170 Repairing Of Well -( 2) Kothuruthi Narayanan 171 50.2.3.1 Pumping Or Bailing Out Water And Removing Slush Etc By Using Pump Set Including Cost Of Labour, Oil Hire Charges Of Pumpset, Etc Complete 172 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20X15Cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 173 13.1.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Fine Sand) 174 10.25.2 Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 175 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed.All Kinds Of Soil 176 Samskarika Nilayam 177 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 178 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level: 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size) 179 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size 180 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 181 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 182 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 183 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 184 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 185 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 186 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide 187 5.9.19 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Weather Shade, Chajjas, Corbels Etc., Including Edges 188 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 189 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete 190 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 191 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 192 13.16.1 6 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete 193 13.4.1 12 Mm Cement Plaster Of Mix: 1:4 ( 1 Cement : 4 Coarse Sand) 194 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface: Water Thinnable Cement Primer 195 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work 196 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work 197 9.48.1 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding 198 21.1.1.3 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpolyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron ) 199 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Polyester Powder Coated Aluminium (Minimum Thickness Of Polyester Powder Coating 50 Micorn) 200 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness 201 11.37A Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 202 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 203 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 204 10.17 Providing And Fixing M.S. Fan Clamp Type I Or Ii Of 16 Mm Dia M.S. Bar, Bent To Shape With Hooked Ends In R.C.C. Slabs Or Beams During Laying, Including Painting The Exposed Portion Of Loop, All As Per Standard Design Complete. 205 10.25.2 Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 206 50.17.1.4 Supplying And Fixing Cp Health Faucet Good Quality Including Cost Of Materials And Labour Charges Etc. Complete As Per The Direction Of Site Engineer-In-Charge. 207 17.2.1 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked White Solid Plastic Seat And Lid Add Specification Below 208 17.7.4 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Flat Back Wash Basin Size 550X400Mm With Single 15 Mm C.P.Brass Pillar Taps 209 18.48Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 210 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore 211 18.58.1.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour.Circular Type 100 Mm Nominal Dia 212 50.18.7.4.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall 213 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm2 214 50.18.9.9.2 Providing And Fixing Pvc Pipes Includes Joints Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 110 Mm Dia 4 Kg/Cm2 215 17.28.1.1 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc. Waste Fittings Complete.Semi Rigid Pipe 32 Mm Dia 216 9.145 Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm) Both Vertical Sides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm ) And 75 Mmx 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 217 50.17.1.3 Supplying And Fixing Cp Towel Rod 60Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 218 51.19.St3 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately)3. 25 To Below 35 Flush Capacity 219 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 220 50.18.9.13.2 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 10 Kgf/Cm2- External Work - Exposed On Wall 221 50.18.9.14.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10 Kgf/Cm2 - External Work- Exposed On Wall 222 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 223 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 224 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 225 50.18.9.22.8 Providing And Fixing Pvc Moulded Fittings /Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia Vent Cowl 226 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site 227 4.1.4 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level: 1:2:4 )1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 40 Mm Nominal Size) 228 50.2.26.1 Filling With Contractor Own Earth (Excluding Rock) In Open Areas In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge. 229 50.2.26.1 Filling With Contractor Own Earth (Excluding Rock) In Open Areas In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge. 230 16.91.2 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-30 Grade With Approved Color Design And Pattern.. 231 51.2.3 Filling With Quarry Muckfilling Up Low Lying And Water Logged Areas With Local Material/ Quarry Muck, Spreading In Layers, Leveling The Top At Site And Consolidation By Ramming, Etc Complete For Improving The Cbr Value Of Subgrade 232 10.5.2 Providing And Fixing 1 Mm Thick M.S. Sheet Door With Frame Of 40X40X6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using Flats 30X6 Mm For Diagonal Braces And Central Cross Piece 233 11.20.4 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand).Ordinary Cement Without Any Pigment 234 50.12.2.1 Providing & Fixing Poly Carbonate Corrugated Sheet 0.8 Mm Thick As Approved By The Engineer In Charge And Should Be Supplied In A Single Length Of 12 M Or As Decide By The Engineer In Charge. The Sheets Shall Be Fixed Using Self Drilling / Self Tapping Screw Of Size (5.5X55 Mm) With Epdm Seal Complete Upto Any Pitch In Horizontal/ Vertical/ Curved Surface, But Excluding The Cost Of Purlins, Rafters, Trusses, And Including Cutting To Size Shapes Where Ever Required. 235 50.9.15.1 Supplying And Fixing 200 Mm Aluminium Aldrop 236 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 237 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 238 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 239 17.60.2.3Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating Without Vent Arm Complete,100 Mm Inlet And 75 Mm Outle Thubless Centrifugally Cast (Spun) Iron Epoxy Coated Inside & Outside As Per Is:15905 Including Cost Of Cutting And Making Good The Walls And Floors: 240 18.58.2.1Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid 150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 241 21.12.2 Providing And Fixing Aluminium Tubular Handle Bar 32 Mm Outer Dia, 3.0Mm Thick & 2100 Mm Long With S.S. Screws Etc. Complete As Per Direction Of Engineer -In-Charge.Powder Coated Minimum Thickness 50 Micron Aluminium Tubular Handle Bar 242 21.13Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete 243 Od37112/2025_2026Fabrication ,Supply, Conveyance & Installation Of Granite Name Board Indicating The Cost Involved, The Commencement, Completion And Inauguration Date Etc 244 Od35639/2025_2026 Multy Wood Panel Letters-Providing And Installing Name Board & Letters 15 To 25Cm Height Using Multi Wood Panel 17Mm Average Thickness, Design As Per The Departmental Approved Drawing( E/M ), Including All Cost Of Materials , Jigsaw Cutting Charges ,All Labour Charges And Conveyance Etc Complete 245 1.27.6 : Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.12 Module (200Mmx150Mm) 246 1.10.2 : Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 247 1.10.1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group A 248 1.10.3Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 249 1.24.4 : Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet 250 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 251 1.14.2Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 252 1.14.3Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 253 1.21.1Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 254 1.28.1Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.1 Or 2 Module 255 1.28.2Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.3 Module 256 1.28.3 Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.4 Module 257 1.28.4Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.6 Module 258 1.28.5Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required.8 Module 259 1.24.1Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amps Switch 260 1.24.2Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.2 Way 5/6 Amps Switch 261 1.24.3Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6Pin15/16 Amp Switch 262 1.24.5Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 263 2.5.3Supplying And Fixing Of Following Ways Surface/ Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting McbS (But Without McbS And Incomer ) As Required .(Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required.)12 Way (4 + 36), Double Door 264 2..13.1Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 265 2.15.2Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 266 5.2Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required 267 1.58Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. 268 1.27.4 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module (200Mmx75Mm) 269 1.27.3 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.4 Module (125Mmx75Mm) 270 2.10.3 Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, \C\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Double Pole 271 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 272 Od377496/2022_2023 Supply Of Ceiling Fan 1200 Mm Sweep, 230V, 1Ph, 5 Star Rated Complete With Double Ball Bearing, Motor Blades, Down Rods, Canopy, Capacitor Etc Complete As Required. (Crompton Asset 50 - 5 Star / Usha Technix Flair / Orient Energy Star). 273 1.45 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standardlength (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable,Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. 274 Od378443/2022_2023 Supply And Installation Of 18 W Led Tube Light (Havells/Philips/Equivalent Make) 275 Od378444/2022_2023 : Supply And Installation Of 9W Led Bulb(Philips/Crompton/Havells/Equivalent) 276 Footpath To O T Kunjiraman House 277 3.5.1 Excavation In Cutting In Soil By Manual Means With Lead Upto 50 Mexcavation For Roadway In Soil Using Manual Means For Carrying Of Cut Earth To Embankment Site With A Lift Upto 1.5 M And Lead Upto 50 M As Per Technical Specification Clause 302.3 278 51.2.3Filling With Quarry Muckfilling Up Low Lying And Water Logged Areas With Local Material/ Quarry Muck, Spreading In Layers, Leveling The Top At Site And Consolidation By Ramming, Etc Complete For Improving The Cbr Value Of Subgrade 279 11.4.3.1 Providing Concrete For Plain/Reinforced Concrete In Open Foundations Complete As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 Iii. P.C.C. Grade M 20 (I) Nominal Mix (1:2:4) 280 Footpath To Damodharan House 281 3.5.1 Excavation In Cutting In Soil By Manual Means With Lead Upto 50 Mexcavation For Roadway In Soil Using Manual Means For Carrying Of Cut Earth To Embankment Site With A Lift Upto 1.5 M And Lead Upto 50 M As Per Technical Specification Clause 302.3 282 51.2.3Filling With Quarry Muckfilling Up Low Lying And Water Logged Areas With Local Material/ Quarry Muck, Spreading In Layers, Leveling The Top At Site And Consolidation By Ramming, Etc Complete For Improving The Cbr Value Of Subgrade 283 11.4.3.1 Providing Concrete For Plain/Reinforced Concrete In Open Foundations Complete As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203Iii. P.C.C. Grade M 20 (I) Nominal Mix (1:2:4) 284 Footpath To Babu Kulangarath House 285 3.5.1 Excavation In Cutting In Soil By Manual Means With Lead Upto 50 M Excavation For Roadway In Soil Using Manual Means For Carrying Of Cut Earth To Embankment Site With A Lift Upto 1.5 M And Lead Upto 50 M As Per Technical Specification Clause 302.3 286 51.2.3Filling With Quarry Muckfilling Up Low Lying And Water Logged Areas With Local Material/ Quarry Muck, Spreading In Layers, Leveling The Top At Site And Consolidation By Ramming, Etc Complete For Improving The Cbr Value Of Subgrade 287 11.4.3.1 Providing Concrete For Plain/Reinforced Concrete In Open Foundations Complete As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203Iii. P.C.C. Grade M 20 (I) Nominal Mix (1:2:4) 288 Protection Wall To House Of Acharambath Sureshbabu 289 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 290 4.1.6 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) 291 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site 292 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) 293 5.22A.2 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Hard Drawn Steel Wire 294 4.3.2 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For:Retaining Walls, Return Walls, (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses Fillets, Kerbs And Steps Etc. 295 Providing Pipe Line For Homes 296 2.8.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 297 19.19.1.1Providing And Fixing In Position Pre-Cast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality.L D - 2.5 Rectangular Shape 600X450 Mm Internal Dimensions 298 50.18.8.6.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 10 Kgf/Cm2 299 Solar Light 300 Od37116/2025_2026Supply And Installation Of 6 M Gi Pole With 24 W Led Luminary Light With Integrated Lithium Phosphate Battery, 75W Solar Panel For Better Performance, Erection And Commissioning Etc., All Complete. 301 Roads 302 (Od Derived From Mord3.15.2)Compacting Original Ground (Ii) Compacting Original Ground Supporting Subgrade Loosening Of The Ground Upto A Level Of 300 Mm Below The Subgrade Level, Watered, Graded And Compacted In Layers To Meet Requirement Of Tables 300.1 And 300.2 For Subgrade Construction As Per Technical Specification Clause 303.5.2. 303 16.78.3 Construction Of Granular Sub- Base By Providing Close Graded Material Conforming To Specifications, Mixing In A Mechanical Mix Plant At Omc, Carriage Of Mixed Material By Tippers To Work Site, For All Leads & Lifts, Spreading In Uniform Layers Of Specified Thickness With Motor Grader On Prepared Surface And Compacting With Vibratory Power Roller To Achieve The Desired Density, Complete As Per Specifications And Directions Of Engineer-In- Charge.With Material Conforming To Grade - Iii ( Size Range 26.5 Mm To 0.075 Mm) Having Cbr Value - 20 304 16.79 Providing , Laying Spreading And Compacting Graded Stone Aggregate ( Size Range 53 Mm To 0.075 Mm) To Wet Mix Macadam (Wmm) Specification Including Premixing The Material With Water At Omc In Mechanical Mix Plant, Carriage Of Mixed Material By Tipper To Site, For All Leads & Lifts, Laying In Uniform Layers With Mechanical Paver Finisher In Sub - Base / Base Course On Well Prepared Surface And Compacting With Vibratory Roller Of 8 To 10 Tonne Capacity To Achieve The Desired Density, Complete As Per Specifications And Directions Of Engineer - In- Charge. 305 51.16.Pc.1Primer Coat - Bitumen Emulsion (Ss-1) - Using Packed Bitumen Rates Providing And Applying Primer Coat With Bitumen Emulsion (Ss-1) On Prepared Surface Of Granular Base Including Cleaning Of Road Surface And Spraying Primer At The Rate Of 0.70 - 1.0 Kg/Sqm Using Mechanical Means As Per Technical Specification Clause 502 (Low Porosity). 306 51.16.31.1.3Pb Tack Coat - Rs Bitumen Emulsion - Using Packed Bitumen Rates Providing And Applying Tack Coat With Bitumen Emulsion (Rs-1) Using Emulsion Distributor At The Rate Of 0.25 To 0.30 Kg Per Sqm On The Prepared Granular Surfaces Treated With Primer & Cleaned With Hydraulic Broom As Per Technical Specification Clause 503. 307 (Od Derived From Mord 75.5.11.1.A.2Pb ) Mix Seal Surfacing - Manual Means - Type A - Bitumen S-65 - Packed Bitumen Rates Providing, Laying And Rolling Of Close-Graded Premix Surfacing Material Of 20 Mm Thickness Composed Of 11.2 Mm To 0.9 Mm (Type-A) Or 13.2 Mm To 0.9 Mm (Type-B) Aggregates Using Penetration Grade Bitumen To Required Line, Grade And Level To Serve As Wearing Course On A Previously Prepared Base, Including Mixing In A Suitable Plant, Laying And Rolling With A Three Wheel 8-10 Kn Static Roller And Finishing To Required Level And Grades As Per Technical Specification Clause 509 By Manual Meanstype A (Ii) Bitumen (S-65),Including Supplying And Stacking Of Materials.
Basic Detail
Tender No SILK/SBU(B)/F-602/2026-27/655
Bidding Type Tender
Location
City Kozhikode
State Kerala
Key Dates
Publish Date 09 Nov 2026
Submission Date 16 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 79.19 Lakhs
Tender Fee 2950
EMD 50000
Exemption Available
Document List
BOQ_1514558.xls
GCC.pdf
PROFILE.pdf
Tendernotice_1.pdf
bd3870ba-a794-4936-8056-a8d316213be8.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1514558.xls

pdf

GCC.pdf

pdf

PROFILE.pdf

pdf

Tendernotice_1.pdf