Bids Are invited for M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty G Lt Cable For 1100 Volts Grade Cross Sectional Area 240 Sqmm 3.5 Core - M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy D
Tender Overview
Project Description
Bids Are invited for M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty G Lt Cable For 1100 Volts Grade Cross Sectional Area 240 Sqmm 3.5 Core - M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 240 Sqmm 3.5 Core , M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Lt Cable With For 1100 Volts Grade Cross Sectional Area 120 Sqmm 3.5 Core - M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 120 Sqmm 3.5 Core , Excavating In Trenches Not Exc 1.50 Mtr Wide And Not Exc 1.50 Mtr In Depth Getting Out In Soft Or Loose Soil , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 250Mm In Soft Or Loose Soil , Removing Excavated Materials Soils Not Exc 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil , M And L Sand Cushioning Dry In Trenches For Protection Of Ug Cables Of 230Mm Spread Thickness And Upto 180Mm Thickness Complete - M And L Sand Cushioning Dry In Trenches For Protection Of Ug Cables Of 230Mm Spread Thickness And Consolidated Upto 180Mm Thickness Complete , M And L For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable , S And F Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Or With Mild Steel Clamps Nuts Bolts Etc - S And F Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Or Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts Etc , M And L For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia Under Road Or Foot Path Not Exc 10.00 Mtr In A Single Length
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty g LT cable for 1100 volts grade cross sectional area 240 sqmm 3.5 core | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 240 sqmm 3.5 core |
| 2 | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised LT cable with for 1100 volts grade cross sectional area 120 sqmm 3.5 core | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 120 sqmm 3.5 core |
| 3 | Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil | Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil |
| 4 | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil |
| 5 | Removing excavated Materials Soils not exc 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil | Removing excavated Materials Soils not exc 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil |
| 6 | M and L Sand Cushioning dry in Trenches for protection of UG Cables of 230mm Spread thickness and upto 180mm thickness complete | M and L Sand Cushioning dry in Trenches for protection of UG Cables of 230mm Spread thickness and consolidated upto 180mm thickness complete |
| 7 | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable |
| 8 | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or with Mild Steel Clamps Nuts Bolts etc | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc |
| 9 | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road or Foot Path not exc 10.00 mtr in a Single Length | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road or Foot Path not exc 10.00 mtr in a Single Length |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender