Bids Are invited for Excavation In Trenches N Exc 1.5 M Wide And N Exc 1.5 Mtr Deep In Soft Lose Soil For Taking Out Pipe And Laying Of Pipe And Getting Out For Diverting Of Ci Pipe Line Complete , Returning Filling In Including Spreading Leveling Wa
Tender Overview
Project Description
Bids Are invited for Excavation In Trenches N Exc 1.5 M Wide And N Exc 1.5 Mtr Deep In Soft Lose Soil For Taking Out Pipe And Laying Of Pipe And Getting Out For Diverting Of Ci Pipe Line Complete , Returning Filling In Including Spreading Leveling Watering And Well Ramming In Layers N Exc 25 Cm Thick Complete , Removal Of Excavated Soil To A Distance Not Exc 50 M And Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point , Taking Up Ci Di Water Main Incl All Fitting With Spigot And Socket Ends And Lead Lead From Pipe Of 100 Mm - Taking Up Ci Di Water Main Incl All Fitting With Spigot And Socket Ends And Lead Joints Incl Burning Out And Recovering Lead From Pipe Of 100 Mm Bore For Relaying Rerouting Of Serviceable Pipe After Cleaning , All As Per Here In Above But 150 Mm Bore , All As Per Here In Above But 200 Mm Bore , Relaying Of Di Or Ci Or Gi Pipe 100 Mm Bore In Trenches Over The Masonry Pillars After Cleaning Thoroughly Including Fittings Complete All As Directed , All As Per Here In Above But 150 Mm Bore , All As Per Here In Above But 200 Mm Bore , M And L Di Pipe Of 100 Mm Bore With Spigot And Socket End Rubber Gas Cate Joint Flanged End With Bolted Joint Centrifugally Cast Class K 7 , All As Per Here In Above But 150 Mm Bore , All As Per Here In Above But 200 Mm Bore , All As Per Here In Above But 250 Mm Bore , Taking Up Or Down 80 Mm Bore Steel Tubing And Connection Including Cleaning For Relaying Or Removal To Store From Trenches Wall Surfaces , All As Per Here In Above But Bore Of Pipe 50 Mm , All As Per Here In Above But Bore Of Pipe 40 Mm , All As Per Here In Above But Bore Of Pipe 25 Mm , All As Per Here In Above But Bore Of Pipe 20 Mm , Relaying Re Fixing Old 80 Mm Bore Gi Tubing Or In Floor Or Pillar Or Wall In New Or Old Position Complete - Relaying/Re-Fixing Old 80 Mm Bore Gi Tubing Or In Floor Or Pillar Or Wall In New Or Old Position Complete , All As Per Here In Above But Bore Of Pipe 50 Mm , All As Per Here In Above But Bore Of Pipe 40 Mm , All As Per Here In Above But Bore Of Pipe 25 Mm , All As Per Here In Above But Bore Of Pipe 20 Mm , M And L 80 Mm Bore Gi Tubing Medium Grade In Trenches Or Floor Or Pillar And Connection In Old Or News Position Including Fitting Like Socket Or Union Or Tee Or Reducer Nipple Etc , All As Per Here In Above But Bore 50 Mm , All As Per Here In Above But Bore 40 Mm , All As Per Here In Above But Bore 25 Mm , All As Per Here In Above But Bore 20 Mm , Taking Up Or Down Pvc Pipe Upto 50Mm Bore And Connection Including Cleaning For Relaying Or Removal To Store From Trenches Or Wall Surfaces Complete , Relaying Or Refixing Pvc Pipe Upto 50Mm Bore In Floor Or Pillar Or Wall In New Or Old Position Including Fitting Complete - Relaying/Re-Fixing Pvc Pipe Upto 50Mm Bore In Floor Or Pillar Or Wall In New Or Old Position Including Fitting Complete , Supply And Laying Of Upvc Pipes 50 Mm Outer Dia. Having Thermal Stability For Hot And Cold Water Supply All Fittings Laid In Trenches Or Wall Including All Fittings Complete , Supply And Laying Of Upvc Pipes 40 Mm Outer Dia Having Thermal Stability For Hot And Cold Water Supply All Fittings Laid In Trenches Or Wall Including All Fittings , Supply And Laying Of Upvc Pipes 20 Mm Outer Dia Having Thermal Stability For Hot And Cold Water Supply All Fittings Laid In Trenches Or Wall Including All Fittings , Supply And Laying Of Upvc Pipes 25 Mm Outer Dia. Having Thermal Stability For Hot And Cold Water Supply All Fittings Laid In Trenches Or Wall Including All Fittings Complete , Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 40Mm Including Fittings If Required Complete - Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 40Mm Including Fittings If Required Complete All As Specified And Directed , Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 50Mm Including Fittings If Required Complete - Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 50Mm Including Fittings If Required Complete All As Specified And Directed , Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 20Mm Including Fittings If Required Complete - Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 20Mm Including Fittings If Required Complete All As Specified And Directed , Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 25Mm Including Fittings If Required Complete - Supply And Fix Pvc Ball Valve Suitable For Upvc Pipe Line Any Type Any Size 25Mm Including Fittings If Required Complete All As Specified And Directed , M And L Di Bend Any Type Radius And Angles Tappers And Type Straight Bendbore Of 250 Mm Complete All As Specified - M And L Di Bend Any Type Radius And Angles Tappers And Type Straight, Bend, Increasing, Decreasing Or Double Socket Etc Tee Pipes Single Branch Y Junction Double Branch Cross All Socket, Socket And Spigot Or Flanged Ends Collors, Caps And Plugs For The Pipes Socket And Spigot All Socket And Flanged Upto Bore Of 250 Mm Complete All As Specified , S F 100 Mm Bore Sluice Valve Pn With Spindle Iron Heavy Duty Wheel Head And Both Ends Flanged And Ms Nut Bolts And Washers And Pair Of Rubber Or Fiber Gasket And Fixed In Position , All As Per Above Item But 150 Mm Bore , Supply And Fix Cast Iron Air Release Valve With Two Air Outlet And Fixing Up In Water Main Of 150Mm Dia With All Fitting Accessories As Per Is Standard , M And L For 50 Mm Bore Gate Valve Gum Metal Class Ii Screwed Down High Pressure With Clutch Handle Screwed Both Ends For Iron Pipe Including Taking Out Of Old Unserviceable Gate Valve , All As Per Above Item But Size 40 Mm Bore , All As Per Above Item But Size 25 Mm Bore , All As Per Above Item But Size 20 Mm Bore , S And F For Straight Plain Brass Ferrules Or Connecting Screws Screwed Bolt Ends Of Size Upto 25 Mm Bore Pipe Complete All As Directed , M And L Pcc 1 4 8 Type D2 Using 40 Mm Graded Stone Aggregate As In Foundation Of Pillar Complete All As Directed , M And L Pcc 1 2 4 Type B 0 Using 12.5 Mm Graded Stone Aggregate As In Coping On Brick Machinary On Of Pillar And Like Complete All As Directed , M And L For Mechanical Joint For Jointing Of Di Pipe Of Size 100Mm Including Excavation Removal And Returning Filling At Site All As Specified And Directed , M And L For Mechanical Joint For Jointing Of Di Pipe Of Size 150Mm Including Excavation Removal And Returning Filling At Site All As Specified And Directed , Refixing Of Sluice Valve From 150 Mm To 250 Bore After Taking Out And Repair Or Refacing Of Valve Spindle Re Grinding If Required Including Taking Part And Replacement Of Unserviceable Parts , All As Per Above Item But Size Upto 100 Mm Bore , Repair To Existing Valve Pit Chamber Any Size With Bricks Works Pcc Works Plasteing Of Internal And External Surfaces Making It Leak - Repair To Existing Valve Pit Chamber Any Size With Bricks Works Pcc Works Plasteing Of Internal And External Surfaces Making It Leak Proof Wherever Required Including Replacement Of Iron Frame Hinges Locking Arrangement Painting Of Iron Frame Painting , S And F Of High Pressure Ptmt Ball Float Valve Suitable For Size Of 25 Mm Dia With Epoxy Coated Aluminum Rod And Hd Plastic Ball Screwed For Iron Pipe , S And F In Repair Round Strand Steel Wire Rope Dia 12 Mm And Connected Clamp Nut Bolts Fixed Complete All As Per Directed , M And L For Brick Massonary Valve Pit With Brick In Cm 1 6 With 100Mm Thick Pcc Work 1 3 6 Type C2 From Fundation Over 75Mm Thick Hard Core , M And L For Brick Massonary Valve Pit With Brick In Cm 1 6 With 100Mm Thick Pcc Work 1 3 6 Type C2 From Fundation Over 75Mm Thick Hard Core - M And L For Brick Massonary Valve Pit With Brick In Cm 1 6 With 100Mm Thick Pcc Work 1 3 6 Type C2 From Fundation Over 75Mm Thick Hard Core Sub Class B Brick Full Brick Thick Wall 15Mm Thick Internal And External Plaster
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr deep in soft lose soil for taking out pipe and laying of pipe and getting out for diverting of CI pipe line complete | Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr deep in soft lose soil for taking out pipe and laying of pipe and getting out for diverting of CI pipe line complete |
| 2 | Returning filling in including spreading leveling watering and well ramming in layers n exc 25 cm thick complete | Returning filling in including spreading leveling watering and well ramming in layers n exc 25 cm thick complete |
| 3 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point |
| 4 | Taking up CI DI water main incl all fitting with spigot and socket ends and lead lead from pipe of 100 mm | Taking up CI DI water main incl all fitting with spigot and socket ends and lead joints incl burning out and recovering lead from pipe of 100 mm bore for relaying rerouting of serviceable pipe after cleaning |
| 5 | All as per here in above but 150 mm bore | All as per here in above but 150 mm bore |
| 6 | All as per here in above but 200 mm bore | All as per here in above but 200 mm bore |
| 7 | Relaying of DI or CI or GI pipe 100 mm bore in trenches over the masonry pillars after cleaning thoroughly including fittings complete all as directed | Relaying of DI or CI or GI pipe 100 mm bore in trenches over the masonry pillars after cleaning thoroughly including fittings complete all as directed |
| 8 | All as per here in above but 150 mm bore | All as per here in above but 150 mm bore |
| 9 | All as per here in above but 200 mm bore | All as per here in above but 200 mm bore |
| 10 | M and L DI pipe of 100 mm bore with spigot and socket end rubber gas cate joint Flanged end with bolted joint centrifugally cast class k 7 | M and L DI pipe of 100 mm bore with spigot and socket end rubber gas cate joint Flanged end with bolted joint centrifugally cast class k 7 |
| 11 | All as per here in above but 150 mm bore | All as per here in above but 150 mm bore |
| 12 | All as per here in above but 200 mm bore | All as per here in above but 200 mm bore |
| 13 | All as per here in above but 250 mm bore | All as per here in above but 250 mm bore |
| 14 | Taking up or down 80 mm bore steel tubing and connection including cleaning for relaying or removal to store from trenches wall surfaces | Taking up or down 80 mm bore steel tubing and connection including cleaning for relaying or removal to store from trenches wall surfaces |
| 15 | All as per here in above but bore of Pipe 50 mm | All as per here in above but bore of Pipe 50 mm |
| 16 | All as per here in above but bore of Pipe 40 mm | All as per here in above but bore of Pipe 40 mm |
| 17 | All as per here in above but bore of Pipe 25 mm | All as per here in above but bore of Pipe 25 mm |
| 18 | All as per here in above but bore of Pipe 20 mm | All as per here in above but bore of Pipe 20 mm |
| 19 | Relaying re fixing old 80 mm bore GI tubing or in floor or pillar or wall in new or old position complete | Relaying/re-fixing old 80 mm bore GI tubing or in floor or pillar or wall in new or old position complete |
| 20 | All as per here in above but bore of Pipe 50 mm | All as per here in above but bore of Pipe 50 mm |
| 21 | All as per here in above but bore of Pipe 40 mm | All as per here in above but bore of Pipe 40 mm |
| 22 | All as per here in above but bore of Pipe 25 mm | All as per here in above but bore of Pipe 25 mm |
| 23 | All as per here in above but bore of Pipe 20 mm | All as per here in above but bore of Pipe 20 mm |
| 24 | M and L 80 mm bore GI Tubing medium grade in Trenches or Floor or Pillar and connection in old or news position including fitting like socket or Union or Tee or Reducer Nipple etc | M and L 80 mm bore GI Tubing medium grade in Trenches or Floor or Pillar and connection in old or news position including fitting like socket or Union or Tee or Reducer Nipple etc |
| 25 | All as per here in above but bore 50 mm | All as per here in above but bore 50 mm |
| 26 | All as per here in above but bore 40 mm | All as per here in above but bore 40 mm |
| 27 | All as per here in above but bore 25 mm | All as per here in above but bore 25 mm |
| 28 | All as per here in above but bore 20 mm | All as per here in above but bore 20 mm |
| 29 | Taking up or down PVC pipe upto 50mm bore and connection including cleaning for relaying or removal to store from trenches or wall surfaces complete | Taking up or down PVC pipe upto 50mm bore and connection including cleaning for relaying or removal to store from trenches or wall surfaces complete |
| 30 | Relaying or refixing PVC pipe upto 50mm bore in floor or pillar or wall in new or old position including fitting complete | Relaying/re-fixing PVC pipe upto 50mm bore in floor or pillar or wall in new or old position including fitting complete |
| 31 | Supply and laying of UPVC pipes 50 mm outer dia. having thermal stability for hot and cold water supply all fittings laid in trenches or wall including all fittings complete | Supply and laying of UPVC pipes 50 mm outer dia. having thermal stability for hot and cold water supply all fittings laid in trenches or wall including all fittings complete |
| 32 | Supply and laying of UPVC pipes 40 mm outer dia having thermal stability for hot and cold water supply all fittings laid in trenches or wall including all fittings | Supply and laying of UPVC pipes 40 mm outer dia having thermal stability for hot and cold water supply all fittings laid in trenches or wall including all fittings |
| 33 | Supply and laying of UPVC pipes 20 mm outer dia having thermal stability for hot and cold water supply all fittings laid in trenches or wall including all fittings | Supply and laying of UPVC pipes 20 mm outer dia having thermal stability for hot and cold water supply all fittings laid in trenches or wall including all fittings |
| 34 | Supply and laying of UPVC pipes 25 mm outer dia. having thermal stability for hot and cold water supply all fittings laid in trenches or wall including all fittings complete | Supply and laying of UPVC pipes 25 mm outer dia. having thermal stability for hot and cold water supply all fittings laid in trenches or wall including all fittings complete |
| 35 | Supply and fix PVC ball valve suitable for UPVC pipe line any type any size 40mm including fittings if required complete | Supply and fix PVC ball valve suitable for UPVC pipe line any type any size 40mm including fittings if required complete all as specified and directed |
| 36 | Supply and fix PVC ball valve suitable for UPVC pipe line any type any size 50mm including fittings if required complete | Supply and fix PVC ball valve suitable for UPVC pipe line any type any size 50mm including fittings if required complete all as specified and directed |
| 37 | Supply and fix PVC ball valve suitable for UPVC pipe line any type any size 20mm including fittings if required complete | Supply and fix PVC ball valve suitable for UPVC pipe line any type any size 20mm including fittings if required complete all as specified and directed |
| 38 | Supply and fix PVC ball valve suitable for UPVC pipe line any type any size 25mm including fittings if required complete | Supply and fix PVC ball valve suitable for UPVC pipe line any type any size 25mm including fittings if required complete all as specified and directed |
| 39 | M and L DI bend any type radius and angles tappers and type straight bendbore of 250 mm complete all as specified | M and L DI bend any type radius and angles tappers and type straight, bend, increasing, decreasing or double socket etc Tee pipes single branch Y junction double branch cross all socket, socket and Spigot or flanged ends collors, caps and plugs for the Pipes socket and Spigot All socket and flanged upto bore of 250 mm complete all as specified |
| 40 | S F 100 mm bore Sluice valve PN with Spindle Iron Heavy duty Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber or fiber gasket and fixed in position | S F 100 mm bore Sluice valve PN with Spindle Iron Heavy duty Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber or fiber gasket and fixed in position |
| 41 | All as per above item but 150 mm bore | All as per above item but 150 mm bore |
| 42 | Supply and fix Cast iron air release valve with two air outlet and fixing up in water main of 150mm dia with all fitting accessories as per IS standard | Supply and fix Cast iron air release valve with two air outlet and fixing up in water main of 150mm dia with all fitting accessories as per IS standard |
| 43 | M and L for 50 mm bore gate valve gum metal class II screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve | M and L for 50 mm bore gate valve gum metal class II screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve |
| 44 | All as per above item but size 40 mm bore | All as per above item but size 40 mm bore |
| 45 | All as per above item but size 25 mm bore | All as per above item but size 25 mm bore |
| 46 | All as per above item but size 20 mm bore | All as per above item but size 20 mm bore |
| 47 | S and F for straight plain brass ferrules or connecting screws screwed bolt ends of size upto 25 mm bore Pipe complete all as directed | S and F for straight plain brass ferrules or connecting screws screwed bolt ends of size upto 25 mm bore Pipe complete all as directed |
| 48 | M and L PCC 1 4 8 type D2 using 40 mm graded stone aggregate as in foundation of pillar complete all as directed | M and L PCC 1 4 8 type D2 using 40 mm graded stone aggregate as in foundation of pillar complete all as directed |
| 49 | M and L PCC 1 2 4 type B 0 using 12.5 mm graded stone aggregate as in coping on brick machinary on of pillar and like complete all as directed | M and L PCC 1 2 4 type B 0 using 12.5 mm graded stone aggregate as in coping on brick machinary on of pillar and like complete all as directed |
| 50 | M and L for Mechanical joint for jointing of DI pipe of size 100mm including excavation removal and returning filling at site all as specified and directed | M and L for Mechanical joint for jointing of DI pipe of size 100mm including excavation removal and returning filling at site all as specified and directed |
| 51 | M and L for Mechanical joint for jointing of DI pipe of size 150mm including excavation removal and returning filling at site all as specified and directed | M and L for Mechanical joint for jointing of DI pipe of size 150mm including excavation removal and returning filling at site all as specified and directed |
| 52 | Refixing of Sluice valve from 150 mm to 250 bore after taking out and repair or refacing of valve spindle re grinding if required including taking part and replacement of unserviceable parts | Refixing of Sluice valve from 150 mm to 250 bore after taking out and repair or refacing of valve spindle re grinding if required including taking part and replacement of unserviceable parts |
| 53 | All as per above item but size upto 100 mm bore | All as per above item but size upto 100 mm bore |
| 54 | Repair to existing valve pit chamber any size with bricks works PCC works plasteing of internal and external surfaces making it leak | Repair to existing valve pit chamber any size with bricks works PCC works plasteing of internal and external surfaces making it leak proof wherever required including replacement of iron frame hinges locking arrangement painting of iron frame painting |
| 55 | S and F of high pressure PTMT ball float valve suitable for size of 25 mm dia with epoxy coated aluminum rod and HD plastic ball screwed for iron pipe | S and F of high pressure PTMT ball float valve suitable for size of 25 mm dia with epoxy coated aluminum rod and HD plastic ball screwed for iron pipe |
| 56 | S and F in repair round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed complete all as per directed | S and F in repair round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed complete all as per directed |
| 57 | M and L for brick massonary valve pit with brick in CM 1 6 with 100mm thick PCC work 1 3 6 type C2 from fundation over 75mm thick hard core | M and L for brick massonary valve pit with brick in CM 1 6 with 100mm thick PCC work 1 3 6 type C2 from fundation over 75mm thick hard core |
| 58 | M and L for brick massonary valve pit with brick in CM 1 6 with 100mm thick PCC work 1 3 6 type C2 from fundation over 75mm thick hard core | M and L for brick massonary valve pit with brick in CM 1 6 with 100mm thick PCC work 1 3 6 type C2 from fundation over 75mm thick hard core sub class B brick full brick thick wall 15mm thick internal and external plaster |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender