Tender For Repair/Replacement Of Lt Electric Cables, Ht/Lt Capacitor Bank, Overhauling Of Ht Vcb, Transformer, Lt Bus Ducts, Lt Acb, Mccb And Street Light Fittings Connected Accessories And Painting Of Electrical Machines, Equipmets And Allied Electr
Tender Overview
Project Description
Tender for Repair/Replacement Of Lt Electric Cables, Ht/Lt Capacitor Bank, Overhauling Of Ht Vcb, Transformer, Lt Bus Ducts, Lt Acb, Mccb And Street Light Fittings Connected Accessories And Painting Of Electrical Machines, Equipmets And Allied Electric Works At Inhs Asvini
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800/1200 Amps from location and repair /overhauling and carrying out with the following all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid separately.) (i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective position & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete. |
| 2 | M & L for painting of HT VCB capacity 250/350MVA,11KV, 400/630/800/1200Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of VCB and all as specified and as directed by Engineer-in-charge. |
| 3 | M & L for Opening the bus-bar chamber, CT chamber, PT Chamber and Meter chamber of HT 11KV, panel board and carry out following and all as directed and specified by Engineer-in-Charge. (Note: spare parts shall be measured & paid seperately.) :-(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B) and HT tape and test with High Voltage(DC) and meggering before and after high voltage test complete.(ii) Inspecting/cleaning/overhauling of CT/PT chamber by checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dust with vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CT's and insulators and HT Tape.(iii) Inspecting/cleaning/overhauling metering chamber by checking of entire wiring system, all meters, selector switches, control fuses and removing dust with vacuum cleaner/blower and moisture by hot air blower and checking tightness of wiring system. |
| 4 | Overhauling, calibration and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete. |
| 5 | Testing of primary injection by artificial load through CT’s, on each multiple setting of over current & earth fault relay, testing polarities, ammeter and selector switch and as directed by Engineer-in-Charge. |
| 6 | Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts, AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately) |
| 7 | Testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: Transformer oil will be measured & paid seperately.) |
| 8 | Supply only transformer oil with 50KV di-electric strength for topping up and replacement of old/burnt transformer oil complete all as specified. |
| 9 | S & F in repair of breather with 500 Grams silica gel of indoor type transformer for 1600KVA, all as specified and directed by Engineer-in-Charge. |
| 10 | M & L for Spray Painting of Transformer 1600KVA ,11KV/440Volt capacity, indoor type with two coats of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities and all as specified and as directed. |
| 11 | M & L for disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer 1600KVA ,11KV/440Volt, top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for attending leakage problem with replacement of oil seal, all gaskets, thermometer(oil temperature gauge) and reassembling complete all as directed.(Note : New Transformer oil and spare parts will be measured and paid separately excluding oil seal and thermometer i.e oil temperature gauge) |
| 12 | M & L in repair of burnt out studs and bushing with nuts of Transformer 1600KVA ,11KV/440Volt, any material by providing new copper alloy stud with nut,washers and bushing with oil seals on HT side all as directed. |
| 13 | M & L in repair for burnt out studs and bushing with nuts of Transformer 1600KVA ,11KV/440Volt, any material by providing new copper alloy stud with nut,washers and bushing with oil seals on LT side all as directed. |
| 14 | S & F in repair of following spare parts suitable for GEC Alsthan make HT VCB, 11 KV , 630/800/1000/1200 Amps indoor type complete all as specified and directed by Engineer-in-Charge.Opening / Closing Push Button Assembly |
| 15 | Motor Charging mechanism gear box |
| 16 | Limit Switches |
| 17 | Closing Coil Assembly |
| 18 | Tripping Coil assembly |
| 19 | Spring Charging Motor |
| 20 | Auxiliary Switch with link |
| 21 | Spring return latch |
| 22 | Vaccum Interupter assembly |
| 23 | Spout Insulator assembly (3Phase) feeder side |
| 24 | Spout Insulator assembly (3Phase) Bus bar side |
| 25 | Potential Transformer,11KV/110Volt/Rout3,100VA burden Trolly mounted with HRC Fuse |
| 26 | Current Transformers,50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec |
| 27 | TNC Switch |
| 28 | PF meters digital type 96x96mm |
| 29 | Indicating Lamps LED type |
| 30 | Supply & fix in repair strip type heater 80 watt with control wiring suitable for indoor VCB,11 KV switch gear Panel board complete all as specified and directed by Engr-in-Charge. |
| 31 | Dismantling Air Circuit Breaker 4pole/3pole, 630/800/1200/2500 Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.(Note : Spare parts will be measured and paid separately) Please Enable Macros to View BoQ information |
| 32 | Dismantling Air Circuit Breaker 4pole/3pole, 630/800/1200/2500 Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.(Note : Spare parts will be measured and paid separately) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender