Housing Urban and Rular Development Government Departments Closing in 4 days TDR #58482747

Tender For Civil Works Related To The Construction And Interior Decoration Of 3 Luxury Suites At The Campus Of The Institute Of Financial Management, Training And Research, Uttar Pradesh, Lucknow, At 24/3 (Electrical Installation Works).

Issued by Government Departments · Lucknow, Uttar Pradesh
Tender Value
60.92 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
4 days left
EMD
5.05 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Civil Works Related To The Construction And Interior Decoration Of 3 Luxury Suites At The Campus Of The Institute Of Financial Management, Training And Research, Uttar Pradesh, Lucknow, At 24/3 (Electrical Installation Works).

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Nov-2026 Revised Date Date 25-Nov-2026
2 12-Nov-2026 Revised EMD Amount Fee 25-Nov-2026

BOQ

Name of Work:- Vittiya prabandh prashikshan evam Shodh Sansthan Uttar Pradesh Lucknow Ke Parisar 24/3 Mein 03 Luxury Suits Ke Nirman Interior Decoration Sambandhit Civil Karya.(Vidhutikaran Karya)
Sl. No. Item Description
1(Part-A) Wiring for light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
2Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
3Wiring for Fan point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
4Wiring for Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
5Wiring for Exhaust fan with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
6Wiring for LED Street Light Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
7Wiring for circuit/ Submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
82 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
92 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
102 X 4 sq. mm + 1 X 4 sq. mm earth wire
112 X 16 sq. mm + 1 X 6 sq. mm earth wire
122 X 6 sq. mm + 1 X 6 sq. mm earth wire
13Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
14Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
15S/F of 8 way SPN DB with additional metallic Double door without MCB/RCCB/ Isolater Cat-A
16S/F of 4 way TPN DB with additional metallic Double door without MCB Cat-A
17Supply and fixing of call bell of approved make on polished MDFEG/ Teak ply board Complete all respect.
18Installation of Exhaust/Fresh air fan in the existing opening including making good the damage connection testing commissioning etc as required.
19Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe with Charcoal/ coke and salt as required etc
20Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
21Supply and drawing 1x1.5sqmm FRLS PVC insulated copper conductor single core cable for invertors
22S/F of 5 to 32 Amp SP MCB
23Supplying and fixing following rating four pole (three phase and neutral), 415 volts, residual current circuit breaker (RCCB) having a sensitivty current 30 mA in the existing MCB DB complete with connections testing and commissionign etx as required.
24S/F of 25 Amp 4 pole RCCB
25S/F of 63 Amp 4 pole RCCB
26Providing and laying G.I Strip 32mm x 6mm from earth electrode directly in ground as required.
27S/F of Brass Compression gland & Aluminum Lugs
28120sqmm 3-1/2 core
2925sqmm 3-1/2 core
3035sqmm 3-1/2 core
3116sqmm 4 core
32S/F of 16 SWG MS drum with Luvers duly painted including marking hole in the wall for fresh air/exhaust fan and finishing properly complete in all respect.
33Supplying and fixing of following rating, DP MCB (10KA) C series MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
3440 Amp DP MCB
35SITC of 1200mm Sweep BEE 5 Star Rated BLDC Fan
36Supply and Laying of Aluminum conductor PVC insulated armored served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top On surface the cable run shall be fixed on M.S clamps etc of suitable sixe or as directed by Engineer in charge complete in all respect including exaction and refilling. The armoring of the cable shall be properly connected with the earth conductor by clamps etc.
37120sqmm 3-1/2 core
3825sqmm 3-1/2 core
3935sqmm 3-1/2 core
4016sqmm 4 core
41Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture
42shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 18-22Watt
43LED Mirror Light
44LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/surface /square/Rectangular) SMD type of following body Down lighter (Round material with PMMA and prismatic diffuser and construction as per IS 10322 with driver as per the requirement Operating voltage AC 140-270 Volt, frequency with Driver efficiency >85%, 50/60 hz, Operating temp range -5 °C to 40 °C. internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P F.20.95, IP20, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body including trim.
45LED Round Light 10 Watt
46LED Round Light 12 Watt
47LED Round Light 18 Watt
48Supply, Installation, Testing and Commissioning of LT Panel vermin proof floor mounting, M.S channel base with bottom and Fabricated out of 2.0/11.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineering-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted don proper interval to ensure the bear the jerks of short Circuit of 50KA for panels having ACB as Incomer & 36KA for panels having MCCB Incomers Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be complete in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering. Incoming 200Amp MCCB-1No., Outgoing 63Amp MCCB -1No., 32Amp MCCB -5No.
49LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥135 lm/Watt).Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI 270, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC i nsulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty System lumen efficacy ≥135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
50Supplying and drawing 20 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor unarmored telephone cable in the existing surface / recessed steel/ PVC Conduit etc. Conduit etc. conplete as required
51Supplying and fixing of following sizes of medium class PVC conduit along with axxessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32 mm
52Supply of Exhaust Fan 300mm Sweep 900/1400 RPM
53Supply of Fresh Air Fan 300mm Sweep (Metaillic)
54Supply and fixing of fire Extinguisher, ABC Type 4.5 kg. capacity (ISI Marked IS :15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
55Supply and fixing of Co2 type fire Extinguisher 4.5 kg. capacity (ISI Marked IS: 2878 & TAC approved) complete with initial charge and wall bracket along with supply of all materials and labour for proper completion of work.
56(Part-B) Fire Fighting WorkProviding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
57100 mm dia
5880 mm dia
59Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmeta & Stainless Steel.
60Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with thefollowing as required. 30 m
61Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
62100 mm dia
63Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
64100 mm dia
65Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Gun meta/Stainless Steel.
66Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Gun meta/Stainless Steel.
67Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required.
68Providing & fixing of pressure switch in M.S. pipe line includingconnection etc. as required.
69(a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018. (d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
70450 LPM at 35 m Head
71SITC of Panel for Terrace Pump installed in Pump Room.
72SITC of Terrace PVC Tank having Capacity of 5000 Liter.
73Supply and Laying of Aluminium conductor PVC insulated armoredserved sheated cable 1100 Volts grade.
7410 sqmm 4 core
75SITC of 25 mm Ball Valve. Complete in all respect.
76Supply installation testing & commissioning of Hose Box of 18 SWG M.S.Sheet with glass fronted door to accommodate 2 nos RRL Hose & 1 no. SS Branch Pipe with nozzle.
77(Part-C) External Electrification WorkSupplying, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender), 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) (Electrolytic grade 99.9% pure copper, Core made of copper wound transformer first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with Offload Tap Changer in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sq.mm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS: 2026 (Part 1 to Part 5), IS: 1180 and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 °C for oil and 40 °C up to 200 KVA and 40 °C for oil and 45 °C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge.
78Design ambient condition: a) air temperature 50 °C, b) Relative Humidity 90% Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked.Fitting and Accessories: The following fittings shall be provided: a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve
79(3½\\" nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1½\\" nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); I) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t)
80Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x).Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. 160 KVA
81S/O D/P Structure with STP Annexure DP for 11 KV
82S/O 11 KV TPMO with Polymer Insulator
83Supply and Laying of 3 core stranded Aluminium Conductor XLPE (Cross linked polyethylene) insulated PVC bedded, galvanized flat steel strip armoured cables confirming to I.S. 7089 (Part II with latest amendments) 11KV grade in existing open masonary duct as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 70sqmm 3 core
84(Part-D) SITC of UPS WorkSITC of 3 Phase input and 3 phase output, 20 KVA UPS (in Parellel configuration), DSP based 30 minutes power backup UPS should have overall efficiency of minimum 95% at 25% to 100% Load Range. True Online Double Conversion UPS using PWM IGBT technology. 3 Phase input operating voltage window 210-478 V or better and input frequency 40-72 HZ or better, UPS shall have continuous rating available till 40 deg C, no derating due to temperature should be present. Battery Racks, Battery to Battery Interlinks, Battery to UPS DC Cable, Battery terminal Caps shall be provided as fresh/new, IGBT Rectifier input for achieving Input Current Harmonics THDi<3%, Input power factor of 0.99 or better @ 100% load, 100% rated Inbuilt static switch & Dual Input is a must.
85(Part-E) SITC of Hydro Pneumatic Water Supply SystemSITC of 4-inch borewell drilling to 200 ft
86Casing development flushing and yield test
87KSB 1.5 HP submersible pump and motor
88Astral 1-inch rising main with cable and installation accessories
89Astral 1-inch delivery run approximately 30 ft
90SVR borewell starter panel and motor protections
91SVR ECOSAND 60 A automatic sand filter with media and valve
92SVR ECOCARBON 60 A automatic carbon filter with media and valve
93SVR ECOSOFT 60 A with resin and automatic valve
94SVR brine tank and regeneration accessories
95SVR 2 KL SS 316 insulated treated-water tank
96SVR hydropneumatic package with 2 pumps pressure vessel and manifolds
97SVR VFD booster panel sensors and automation
98Interconnections isolation valves gauges flow measurement bypass and drain connections
99Rooftop equipment bases supports and electrical connections within agreed limits
100Freight lifting to roof installation testing commissioning and training
101(Part-F) SITC of VRV/VRF SystemSupplying, Installation, Testing and Commissioning of 24 HP VRV/VRF system including indoor / outdoor units piping electrical power distribution/ wiring electrical panel treated fresh air system etc.
102Ground FloorSuit-1 Drawing Room 4 Way Cassette (01 Qty.)
103Bed Room Hi-wall (01 Qty.)
104Bed Room Hi-wall (01 Qty.)
105Suit-2 Drawing Room 4 Way Cassette (01 Qty.)
106Dining Room 4 Way Cassette (01 Qty.)
107Bed Room Hi-wall (01 Qty.)
108Suit-3 Drawing Room 4 Way Cassette (01 Qty.)
109Floor Capacity in HP (Qty. 19.06)
110Outdoor Capacity in HP (Qty. 24)
111Diversity (Qty. 96%)
112Supply of VRV-α air-conditioning system (equipment’s) comprising of following items Outdoor Units-(R410A)ODU- 24 H.P (RXYQ24BRY16) VRV-α Heat Pump Series (Qty. 1 Nos.)
113DGT (Qty. 1 Nos.)
114Indoor Units & AccessoriesHi-wall type unit Ac 2.35 Tr+Cordless remote+Refnet (Qty. 3 Nos.)
1154 Way Cassette type unit Ac 2.08 Tr+Cordless remote+Refnet+Panel (Qty. 1 Nos.)
1164 Way Cassette type unit Ac 3.31 Tr+Cordless remote+Refnet+Panel (Qty. 3 Nos.)
117Low Side WorkInstallation of VRV airconditioning system of following items Variable Refrigerant Volume SystemLifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings(Imported Y-joints & header etc.) remote controls of indoor units, complete as per specification and drawings.
118Outdoor Unit (Qty. 2 No.)
119Indoor UnitsCassette Type Unit (Qty. 4 No.)
120Hi-wall Type Unit (Qty. 3 No.)
121Commissioning of VRV systems including charging of R410A gas as per site requirements (Qty. 16 Kg.)
122Refrigerant PipingInterconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported41.3 mm (1 5/8 \\") (Unit. 16 RM)34.9 mm (1 3/8 \\") (Unit. 8 RM)28.6 mm (1 1/8 \\") (Unit. 10 RM)22.2 mm (7/8 \\") (Unit. 5 RM)19.1 mm (6/8 \\") (Unit. 31 RM)15.9 mm (5/8 \\") (Unit. 40 RM)12.7 mm (1/2 \\") (Unit. 5 RM)9.5 mm (3/8 \\") (Unit. 33 RM)6.4 mm (1/4 \\")
123Drain PipingProviding and fixing rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. 32 mm dia (Unit. 20 RM)25 mm dia (Unit. 40 RM)
124Control & Transmission WiringProviding & fixing control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit. (Unit 122.5 Rmt.)
125Supply and Fixing of Outdoor Stand (Unit 2 No.)
126(Part-G) SITC of Illuminated SignagesIlluminated Signages (Rate applicable on total plinth area)
127GST @ 18% Extra Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58482747
AUTHORITY Government Departments
TENDER VALUE 60.92 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Public Works Department
Work Description Tender For Civil Works Related To The Construction And Interior Decoration Of 3 Luxury Suites At The Campus Of The Institute Of Financial Management, Training And Research, Uttar Pradesh, Lucknow, At 24/3 (Electrical Installation Works).
Basic Detail
Tender No 1273/4CBW-17EM/2026 Date 22-10-2026
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 12 Nov 2026
Submission Date 25 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 60.92 Lakhs
Tender Fee 2354
EMD 5.05 Lakhs
Exemption Not Available
Document List
3defd1ee-d471-4011-9f5a-d119f96a37b1.html
BOQ_2288221.xls
T2T1273Vitya.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 25, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

3defd1ee-d471-4011-9f5a-d119f96a37b1.html

xls

BOQ_2288221.xls

pdf

T2T1273Vitya.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender