Project Description

Tender for Construction Of Hsvp Office Complex At Jind (Cm Announcement Code No. 29788 Dated 05.04.2026) Construction Of Hsvp Office Complex Building Including Civil Works, Public Health Work, Electrical Work, Sanitary Installation, Providing And Fixing Office Furniture I.E. Chairs, Tables Etc, Installation Of Air Conditioners, Dismantling Of Existing Structure, Construction Of Boundary Wall Complete In All Respect As Per Satisfaction Of Engineer-In-Charge At Safidon Road Jind And All Other Works Contigent Thereto (Including Three Years Maintenance And Defect Liability Period Free Of Cost).

BOQ

Name of Work:- CONSTRUCTION OF HSVP OFFICE COMPLEX AT JIND (CM Announcement Code No. 29788 dated 05.04.2026) `Construction of HSVP office complex building including Civil works, public health work, Electrical work, sanitary installation, providing and fixing office furniture i.e. chairs, tables etc, installation of Air conditioners, dismantling of existing structure, construction of boundary wall complete in all respect as per satisfaction of Engineer-in-Charge at Safidon Road Jind and all other works contigent thereto` (Including Three years maintenance and defect liability period free of cost).
Sl. No. Item Description
1[10.100.2]Cement Concrete 1:8:16 Flooring 2. Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. [Through Rate]
2[10.107]Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 0 0 0 [Through Rate]
3[10.15]Extra for using hardener at top surface (3.5Kg /sqm) of trimix M25 to finish surface complete in all respect [Through Rate]
4[10.17]Providing and laying polythene sheet under CC M-25 in road and parking complete in all respect [Through Rate]
5[10.18]Extra for making chequers (2mm deep) of approved pattern on cement concrete floors, steps, landing, pavements etc. [Through Rate]
6[10.31.2.1]Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. 2.1. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile [Through Rate]
7[10.45]Extra for pre finished nosing to treads of steps of marble stone. [Through Rate]
8[10.49.1]Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 1. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
9[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
10[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate]
11[10.6]Providing and laying of screed of 40 mm thick cement concrete 1:4:8 to be laid below the topping. [Through Rate]
12[10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate]
13[10.63.4]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 4. Size of Tile 1000x1000 mm [Through Rate]
14[10.67.4]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 4. Size of Tile 1000x1000 mm [Through Rate]
15[10.70.4]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 4. Size of Tile 1000x1000 mm [Through Rate]
16[11.121]Polyurethane polish (PU) two or more coats to give required finish including two coat of wood sealer Including Preparation of surface/base complete as per specification [Through Rate]
17[11.122]Painting two or more coats Italian Pigmented PU white glossy or matt in all shades on wood work surface to give an even shade Including Preperation of surface/base complete as per specification [Through Rate]
18[11.15]6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. [Through Rate]
19[11.39]Washed stone grit plaster on exterior walls height up to 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). [Through Rate]
20[11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) [Through Rate]
21[11.5.1]12 mm cement plaster of mix : 1. 1:2 (1 cement: 2 fine sand) [Through Rate]
22[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
23[11.54]Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. [Through Rate]
24[11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) [Through Rate]
25[11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate]
26[11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer [Through Rate]
27[11.75.2]Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats [Through Rate]
28[11.8.1]12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand) [Through Rate]
29[11.82.1]Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate]
30[11.83.1]Painting over the wooden surface with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 1. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture [Through Rate]
31[11.85.1]Painting over wooden/metal surface with acid proof paint of approved brand and manufacture of required colour to give an even shade : 1. Two or more coats on new work [Through Rate]
32[11.9.1]15 mm cement plaster on rough side of single or half brick wall of mix: 1. 1:4 (1 cement: 4 coarse sand) [Through Rate]
33[11.94.1]Finishing walls with textured exterior paint of required shade : 1. New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm [Through Rate]
34[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate]
35[12.1.1.1]Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid separately). 1.1. Second class teak wood [Through Rate]
36[12.102.2]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm [Through Rate]
37[12.177.1]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With toughened glass panes of 6 mm thickness (weight not less than 15 kg/sqm) [Through Rate]
38[12.19.1.1.1]Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1.1.1. 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood [Through Rate]
39[12.27.1]Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 1. 18 mm thick [Through Rate]
40[12.3.3.1.2]Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 3.1.2. 2nd class teak wood 50 x 20 mm [Through Rate]
41[12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate]
42[12.50.2]Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 2. Fixed to openings /wooden frames with rawl plugs screws etc. [Through Rate]
43[12.60.1]Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : 1. 150 mm [Through Rate]
44[12.7.1.1]Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 1.1. Second class teak wood 35 mm thick shutters [Through Rate]
45[12.76.1]Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 1. 125x85x5.5 mm (heavy type) [Through Rate]
46[12.76.5]Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 5. 75x65x4 mm (heavy type) [Through Rate]
47[12.80]Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. [Through Rate]
48[12.83.2]Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 2. 50 mm [Through Rate]
49[12.86]Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. [Through Rate]
50[12.88]Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete. [Through Rate]
51[13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate]
52[13.3.3.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 3.1. Profile E Fixing with adjustable lugs with split end tail to each jamb [Through Rate]
53[13.30.2]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 2. Hot finished seamless type tubes [Through Rate]
54[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate]
55[13.42.1]Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 1. M.S. tube [Through Rate]
56[15.1.2.1]Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per clause 304 of MORTandH specifications Ordinary soil 2.1. Mechanical Means Depth up to 3 m [Through Rate]
57[17.14.1]Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix method Construction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 1. Grading I material [Through Rate]
58[17.22.1]Water Bound Macadam Gr I 1. Water Bound Macadam Grading I (without screenings for low volume roads (undesignated) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications [Through Rate]
59[17.44]Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing, as per clause 601 of MORT&H specifications [Through Rate]
60[17.45]Cement Concrete Pavement Construction of un-reinforced M-40 grade concrete pavement with dowel jointed, over a prepared sub base with 43 grade OPC cement concrete coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a fully computerised batching and mixing plant as per approved mix design, transported to site in transit mixer with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing, complete as per clause 602 of MORT&H specifications. [Through Rate]
61[17.5.3]Compacting Original Ground 3. Compaction of Earthwork Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications [Through Rate]
62[2.B0663] B0663. Powder coated Aluminium Tower bolt (100x10mm) [Rate]
63[2.B0664] B0664. Powder coated Sliding Bolt 250 x 16 mm [Rate]
64[2.B2013] B2013. PVC slotted pipe 150 mm dia as per IS: 12818 [Rate]
65[2.B2014] B2014. PVC slotted pipe 200 mm dia as per IS: 12818 [Rate]
66[2.B2020] B2020. uPVC slotted pipe 100 mm dia as per IS: 12818 [Rate]
67[2.RM079] RM079. Earth Cost or compensation for earth taken from private land [Rate]
68[20.26.1]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall [Through Rate]
69[20.26.2]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall [Through Rate]
70[20.28.2]Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 2. 115 mm thickness of roof or floor [Through Rate]
71[20.30.1]Fixing galvanised malleable iron holder bats hold fasts to pipe lines fixed on walls and ceilings including all cutting to walls and making good to original condition. 1. 15 mm internal diameter of pipeline [Through Rate]
72[20.30.3]Fixing galvanised malleable iron holder bats hold fasts to pipe lines fixed on walls and ceilings including all cutting to walls and making good to original condition. 3. 25 mm internal diameter of pipeline [Through Rate]
73[20.52.1]providing and placing in horizontal layers filtering media screened washed and cleaned as described below - 1. Top Layer: Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4 mm with uniformity coefficient 2.0 to 3.0) from Ghaggar or other approved source [Through Rate]
74[20.52.2]providing and placing in horizontal layers filtering media screened washed and cleaned as described below - 2. Second layer Coursed sand screened, cleaned and washed and graded from 3 mm to 6 mm (from Ghaggar or approved equivalent quarry) [Through Rate]
75[20.52.3]providing and placing in horizontal layers filtering media screened washed and cleaned as described below - 3. Third layer Bajri (coursed) screened and washed graded from 20 mm to 25 mm (from Ghaggar or approved equivalent quarry) [Through Rate]
76[20.52.4]providing and placing in horizontal layers filtering media screened washed and cleaned as described below - 4. Fourth layer Bajri (coursed) screened and washed graded from 20 mm to 25 mm (from Ghaggar or approved equivalent quarry) [Through Rate]
77[20.52.5]providing and placing in horizontal layers filtering media screened washed and cleaned as described below - 5. Bottom layer Broken stone, screened, washed and graded from 50 mm to 75 mm (from Ghaggar or approved equivalent quarry) [Through Rate]
78[20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate]
79[20.8.7]Jointing A.C./P.V.C. pipes and specials with cast iron detachable joints/split coupler P.V.C. joints fitted with bolts and nuts excluding cost of detachable joints/ split coupler P.V.C. joints rubber rings, bolts and nuts but including cost of labour and tools etc. and tested complete. 7. 250 mm i/d pipe [Through Rate]
80[20.9.5]Cutting A.C./P.V.C. pipes and specials and chipping or filing surface to a uniform finish. 5. 150 mm i/d [Through Rate]
81[20.9.7]Cutting A.C./P.V.C. pipes and specials and chipping or filing surface to a uniform finish. 7. 250 mm i/d [Through Rate]
82[20.91]Providing and Lowering 225 mm outer dia UPVC pipe threaded (10kg/CM2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge [Through Rate]
83[20.92]Providing and lowering 225mm outer dia UPVC filter Jali (10 Kg/CM2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge [Through Rate]
84[20.93]Providing and fixing 250 mm M.S. clamp as for suitable pipe with nut and bolt complete in all respect as per directions of Engineer-in-charge [Through Rate]
85[20.94]Providing and fixing UPVC cap for 225mm outer dia UPVC pipe (10kg/cm2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge [Through Rate]
86[20.96.1]Water Supply installation of shallow/Medium/Deep tubewells as per IS 2800:1991 Drilling of 609.60mm dia bore by hydraulic rotary drilling (reverse circulation method) according to ISI specification No. 2800-1991 (Part-I) as amended up to date and modified to extent of the specification attached with this schedule of items of work in all kinds of soils and boulders up to 125 mm dia except rocky strata including the cost of all consumable stores, fuel, oil, soil stabilizing material and transportation of rig and other accessories to the site of proposed bore and back including cost of lowering of all size of casing pipe while boring and extracting the same against earth friction etc. 1. Drilling from 0 metre but up to 200 metre BGL [Through Rate]
87[21.48]Fixing cast iron road gully grating and frame complete including carriage from the stores of the Engineer-in-charge of the works, loading, fixing and erecting the same in position to correct lines and levels in 1:2 cement sand mortar and painting of grating and frame with coal tar. [Through Rate]
88[21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate]
89[21.84.2]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) [Through Rate]
90[21.93.1]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening [Through Rate]
91[22.10.1.4]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1.4. Kitchen sink with drain board 510x1040 mm bowl depth 178 mm [Through Rate]
92[22.100.3]Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 3. 25 mm nominal bore [Through Rate]
93[22.101.1.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 1.1. 30 cm length 15 mm nominal bore [Through Rate]
94[22.102.1]Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 1. 100 mm diameter [Through Rate]
95[22.103.1]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore [Through Rate]
96[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate]
97[22.105.1]Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore [Through Rate]
98[22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore [Through Rate]
99[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate]
100[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate]
101[22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate]
102[22.110.1]Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 1. 15 mm nominal bore [Through Rate]
103[22.117]Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. [Through Rate]
104[22.119.2]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. [Through Rate]
105[22.123.1.1]Providing and fixing PTMT grating of approved quality and colour. 1.1. Circular type 100 mm nominal dia [Through Rate]
106[22.14.1.2]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.2. Semi rigid pipe 40 mm dia [Through Rate]
107[22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate]
108[22.163.1]Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 1. 100 mm diameter [Through Rate]
109[22.17.1]Providing and fixing 40mm i/d chromium plated trap with chromium plated pipe to wall with walflange completed for use with sinks 1. With Bottle Trap (Indian make) [Through Rate]
110[22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. [Through Rate]
111[22.19]Providing and fixing 100 mm sand cast Iron grating for gully trap. [Through Rate]
112[22.20.2]Providing and fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete 2. With 75 mm internal diameter outlet [Through Rate]
113[22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate]
114[22.222.1.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 1.2. Single Socket Type A 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]
115[22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate]
116[22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate]
117[22.39.1]Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 1. 10 litre capacity - White [Through Rate]
118[22.41]Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. [Through Rate]
119[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate]
120[22.45]Providing and fixing white vitreous chinaware water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. [Through Rate]
121[22.50.1.1.1]Providing and fixing partitions for different type of urinals. 1.1.1. Vitreous Chinaware Partition plate. Small size 680mm x 330 mm White [Through Rate]
122[22.50.1.2.2]Providing and fixing partitions for different type of urinals. 1.2.2. Vitreous Chinaware Partition plate. Large size 835mm x 355 mm Single Colour [Through Rate]
123[22.55.1.1]Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1.1. 100 mm dia Sand cast iron S&S as per IS - 1729 [Through Rate]
124[22.81.1]Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1. 100 mm dia [Through Rate]
125[22.81.2]Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 2. 75 mm dia [Through Rate]
126[22.86.1]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes [Through Rate]
127[22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate]
128[22.87.10]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 10. 150 mm nominal inner dia Pipes [Through Rate]
129[22.87.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 6. 50 mm nominal outer dia Pipes [Through Rate]
130[22.87.8]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 8. 75 mm nominal inner dia Pipes [Through Rate]
131[22.87.9]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 9. 100 mm nominal inner dia Pipes [Through Rate]
132[22.97.1]Providing and fixing brass stop cock of approved quality : 1. 15 mm nominal bore [Through Rate]
133[22.98.1]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore [Through Rate]
134[22.99.1.1]Providing and fixing gun metal non- return valve of approved quality (screwed end) : 1.1. 25 mm nominal bore Horizontal [Through Rate]
135[22.99.1.2]Providing and fixing gun metal non- return valve of approved quality (screwed end) : 1.2. 25 mm nominal bore Vertical [Through Rate]
136[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA [Through Rate]
137[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate]
138[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]
139[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate]
140[23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate]
141[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate]
142[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]
143[23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate]
144[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
145[23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate]
146[23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE [Through Rate]
147[23.22.8.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.4. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 300 amp 415 volts [Through Rate]
148[23.23.2.1]MISCELLANEOUS 2.1. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia [Through Rate]
149[23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire [Through Rate]
150[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
151[23.24.3.2]MS STAND, BUS BAR CHAMBER AND PANELS 3.2. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 100 amp 4 bars of 55 cm each (cross section 25 mm x6 mm) chamber over all size 60 cm x 45 cm x 18cm [Through Rate]
152[23.24.4.1]MS STAND, BUS BAR CHAMBER AND PANELS 4.1. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp. [Through Rate]
153[23.24.4.2]MS STAND, BUS BAR CHAMBER AND PANELS 4.2. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 250 amp. [Through Rate]
154[23.27.4]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 4. M.S. pedestal of size 900 mm wide , 1500 mm high , 450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1050 mm x 600 mm x 200 mm above ground level ,having a base of size 1200 mm x 750 mm x 250 mm below ground level . 0 0 [Through Rate]
155[23.28.1.3]Supplying, installation, Testing and Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5%), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 and (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 3. Powder coated die cast /Extruded aluminum Body including trim 12-15 watt [Rate]
156[23.28.1.6]Supplying, installation, Testing and Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5%), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 and (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 6. Powder coated die cast /Extruded aluminum Body including trim 30 watt [Rate]
157[23.28.12.16]Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 16. 120 watt [Rate]
158[23.28.13.13]Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 13. 72 watt [Rate]
159[23.28.31.9]Supplying, Installation, Testing and Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV plus or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system, including testing at factory and site with fuel, load for test and other necessary arrangements with rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Deg C, 50% RH and at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV plus or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018. (B) Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubrication Oil trip indication(ix) Engine Running Hours indication (x) Fuel Level(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH and at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame and Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK: Daily service fuel tank of suitable liters capacity, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications and accessories as required as per specifications.(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof and dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV plus or better norms etc. and.(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering and protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase and Total), KW and provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C and E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN and L_L), kW, kVA (Phase and Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier,D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour and due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.19. Suitable rating of AC contactors/ ATS / ACB with control wiring. 9. 160 KVA [Rate]
160[23.28.5.5]Supplying, installation, Testing and Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. `complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 5. Powder coated die cast with Aluminium Reflector 22 watt [Rate]
161[23.28.5.6]Supplying, installation, Testing and Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. `complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 6. Powder coated die cast with Aluminium Reflector 30 watt [Rate]
162[23.29.1.1]Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required 1. 900mm, service value >= 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) [Rate]
163[23.29.1.2]Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required 2. 1050mm, service value >= 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum) [Rate]
164[23.29.1.3]Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required 3. 1200mm, service value >= 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) [Rate]
165[23.29.1.4]Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required 4. 1400mm, service value >= 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) [Rate]
166[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
167[23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
168[23.30.1.1]Supply, Installation, Testing and commissioning of EV charging station As per specifications and in Compliance to relevant IS codes etc. 1. Light EV AC Charger (Mode-3) Power : 7 kW, Input power supply: 1phase 230 +10% Volt, output supply: 230 Volt AC, Frequency:50 Hz +/-3%, Operational temperature range : -25 to 55 degree C (outdoor), -5 to 55 degree C(Indoor)., RH upto 95%, Charging Device as per IS-17017-22-1 EV-EVSE Communication: as per relevant IS Codes, Bluetooth Low Energy, one Charge Point Plug/ Socket as per IS- 60309 and IS-17017-2, Vehicle Inlet/ Connector As per EV manufacturer, suitable for 2 Wheelers and 4 wheelers. Indoor use: at least IP41; Outdoor use: at least IP44. Mechanical Strength :protection of the external enclosure against mechanical impact shall be IK08 according to IEC 62262.O/L,S/C protection. Insulation Resistance > 1 M O. Cable Length: 7.5 m. RCD having a rated residual operating current not exceeding 30 mA; Separate RCD for multiple outputs. Telecommunication port of the EV supply equipment according to IS 13252 (Part 1) : 2010. OCPP(Open charge point protocol) 1.6J upgradable to ocpp 2.0. Device Should follow 17017 series of IS codes in general and the installation of the system shall comply with relevent IS Codes. [Rate]
169[23.32.1.1]Automatic Power Factor Correction (APFC) SystemSupply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V plus 10 %, 50 Hz AC System for Ambient temperature -5°C to plus 40°C, fabricated in compartmentalized designed made of CRCA sheet steel of 2.0mm thick for framework and covers, 3 mm thick for gland plate i/c cleaning and finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminum alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 and 2) APFC Panel shall be in compliance with IS :16636 and CPWD Specifications etc. as per below details(A) Incomers Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.(B) Instruments and Indications i) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100 KVAR and above) with Communication Ethernet/RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT`s accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.i) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.ii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V and I, Frequency.iii) Suitable rating control transformer shall be provided for control and indication circuit.i) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB`s.ii) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS 1100 V grade, PVC insulated multi stranded copper control wire.(B) Bus Bars1.3 Amp per Sq.mm, TPN, Electrolytic grade Aluminum bus bar of capacity 1.25 times of incomer rating as per CPWD specification.(C) Outgoings (APFC Section)Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty contactor, the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections inter connections etc. and other features as per CPWD Specifications and relevant IS Code having following:(i) Capacitor bank ratings and stages shall be as per(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism.(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts.(iv) 14% Detuned Reactor of class H insulation and 150% linearity in series with Capacitor. 1. 50 KVAR [Rate]
170[23.33.1 (a).3]Online UPS - Input supply: Single Phase, Output Supply : Single PhaseSupplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)`s both for the rectifier and inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be )95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be ( 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz plus /- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 and 3). The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 3. 6KVA [Rate]
171[23.33.2.1]Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 3 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of plus 5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with plus 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked.Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature: c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates: e) Silica gel breather f) Drain-cum-sampling valve (¾? nominal size thread, IS 554) preferably steel with plug for three phase transformers: g) Thermometer pocket with cap: h) Oil filling holes having (1¼? nominal size thread) with cover (for sealed type transformers without conservator): i) Lifting lugs for the complete transformer as well as for core and winding assembly: j) Pressure relief device or explosion vent above 200 kVA: k) One filter valve on the upper side of the tank (for transformers above 200 kVA): l) Unidirectional flat rollers (for transformers above 200 kVA): m) Inspection hole (for transformers above 200 kVA): n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth):o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard: r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA): t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact: v) Non return valve (for conducting pressure test): w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. 1. 200KVA (Offload Tap Changer) [Rate]
172[23.4.1.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B [Through Rate]
173[23.4.3.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B [Through Rate]
174[23.4.4.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B [Through Rate]
175[23.4.5.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B [Through Rate]
176[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
177[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate]
178[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate]
179[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate]
180[23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate]
181[23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type [Through Rate]
182[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate]
183[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
184[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
185[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate]
186[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
187[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]
188[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]
189[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
190[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate]
191[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
192[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate]
193[24.11.11]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 11. 6 Sq mm 4 core (UnArm.) [Through Rate]
194[24.11.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 32. 25 Sq mm 4 core (Arm.) [Through Rate]
195[24.11.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 82. 185 Sq mm 3.5 core (Arm.) [Through Rate]
196[24.13.12]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 12. 6 Sq mm 4 core (Arm.) [Through Rate]
197[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]
198[24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48. 50 Sq mm 4 core (Arm.) [Through Rate]
199[24.13.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70 Sq mm 3.5 core (Arm.) [Through Rate]
200[24.13.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 70. 120 Sq mm 3.5 core (Arm.) [Through Rate]
201[24.13.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 82. 185 Sq mm 3.5 core (Arm.) [Through Rate]
202[24.15.2]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in 1 per meter below ground level with sand and bricks with all labour and material including digging and refilling of trench as required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 2. 50 Sq mm 3 core [Through Rate]
203[24.16.2]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 2. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 50 Sq mm 3 core [Through Rate]
204[24.2.7.1]LT CABLE 7.1. Supply and erection of suitable compression type brass cable glands for underground Cable :- Up to 6 Sq mm cable 2 to 4 Core [Through Rate]
205[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate]
206[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core [Through Rate]
207[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core [Through Rate]
208[24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm [Through Rate]
209[24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm [Through Rate]
210[24.2.8.2]LT CABLE 8.2. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 4 sqmm to 6 sqmm [Through Rate]
211[24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm [Through Rate]
212[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm [Through Rate]
213[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm [Through Rate]
214[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate]
215[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate]
216[24.4.3]STREET LIGHT 3. Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. [Through Rate]
217[24.7.4]RCC FOUNDATIONS FOR DG SET 4. 125 KVA DG Set [Through Rate]
218[25.11.2.2]HI - WALL SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS:1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). 2. Inverter Type- Cooling only 1.0 TR with 5 Star BEE Rating [Rate]
219[25.11.2.3]HI - WALL SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS:1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). 3. Inverter Type- Cooling only 1.5 TR with 5 Star BEE Rating [Rate]
220[25.11.2.4]HI - WALL SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS:1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). 4. Inverter Type- Cooling only 2.0 TR with 5 Star BEE Rating [Rate]
221[26.76]Providing and fixing pair of Plastic dustbins 100 litre volume each, of two different colours, for dry and wet waste, made of virgin plastic to be mounted on MS rectangular hollow section 50 x 25 x 3 mm frames pivoted on 3 MS square hollow section verticals, 1 m above ground, one 35 cm RHS welded to each vertical member at base and grouted in 180 x 40 x 30 cm 1:2:4 cement concrete. [Through Rate]
222[28.39]Water proofing of roof terraces, Basements, Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of 2 coats of Elastobar and Zycoprime/Equivalent after application of Zycosil and Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brush able. Apply the paste on surface with brush. Leave the surface for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementitious membrane using mixture of 1 Part of Zycoprime plus 1 Part of Cement plus 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed. [Through Rate]
223[3.1.18]By Mechanical Transport including loading, unloading and stacking 18. Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead up to 10 km for all lifts, complete as per directions of Engineer-in-charge. [Rate]
224[3.1.2]By Mechanical Transport including loading, unloading and stacking 2. Earth [5km]
225[30.88.1]Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1. For pipes 100 to 250 mm diameter [Through Rate]
226[30.93]Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube Challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. [Through Rate]
227[37.1.3]Supplying, installation, Testing and commissioning of the passengerMachine Room less (MRL) lift having following main features:a) MOTOR : Gearless lift drive comprising of high starting torque liftduty, 3 phase 440 Volts A.C. permanent magnetic synchronous motor ofproper rating with high efficiency shall be used.b) Operation/Drive : Microprocessor based /PLC, AC VariableVoltage variable frequency variable speed (V3F) vector control drive withencoder feedback closed loop system shall be used for lift car and dooroperation which shall be full collective selective operation hall call demandresponse, UP/Down hall stops, main, Up/Down contactor with overload andphase reversal relay and safety controls.c) Traction Media: main hoist flat coated steel belt / rope. Thimblesof spring permit adjustment of uniform tension for smooth operation of theelevator Pulse belt monitoring system to avoid the cut in the belt.d) Car : car should be with M S platform with bracings of adequatesize and to sustain the impact load cabin plus passengers with safety factorof fire for steel with Anti-skid PVC flooring and side panels should be ofStainless steel with hair line finish of sheet of grade 304 duty with S.S.handrails . Car ceiling shall be steel finish with aesthetic appearances withLED ceiling lights .The size of the car shall be taken as per available lift wellsize and relevant BIS code of lifts. Car panel will also be of S S 304 gradefinished with emergency stop device, emergency alarm, mechanical doorsafety device, full length infra-red curtain in car door, facility ofauto/attended mode. All car panel buttons and all floor switches must bewith brail language as per lift act. Agency shall also provide and install oneNo. 2 MP , IR , IP based ceiling mounted Dome Camera in the car completewith connecting cables and accessories (To be connected with existing CCTVsystem in the Building) .The inspection unit shall be provided at the top ofthe car. e) Landing Doors: All landing door shall be fully automatic centeropening / telescopic made of hair line finish stainless steel grade 304 withkey holes and infrared curtains with unlocking facility from outside.f) Emergency light: Appropriate rechargeable battery operated LEDemergency light in the car and along with alarm switch shall be provided.g) ARD: Automatic rescue Device (ARD) shall be provided accordingto passenger capacity with SMF batteries of approved brands.h) Audio-Visual Indication: Audio visual indication in the lift car,showing over loading such that doors kept open till excess load is removed.i) Scrolling Indicators: Digital scrolling indicator system for up-downarrow with floor position indicator shall be provided inside the car and at allstops/floors.j) Buffers: Spring buffers/PU Buffers shall be provided.k) Car Fan: ENERGY EFFICIENT Car fan/blower with automaticsleep timer shall be provided.l) Voice Annunciator: Voice annunciator with suitable music shall beprovided in lift car.m) Self diagnostics system for operational and safety parametersshall be provided in control panel.n) Mechanical/Electronic over speed governor, door key holes in thefloor doors, fireman switch shall be provided.o) Permanent wiring in lift well with providing and fixing of electricaldistribution board complete with SP and TP MCB`s, proper numbers of lightpoints, with LED fixtures, exhaust fan, 2 nos copper plate /chemicalearthing with 8 SWG copper earth wire and plug points shall be provided by the agency. (Power supply of 3 phase 440 V shall be made available bydepartment in lift machine room.)p) Agency has to provide all working drawings and documents tocomply latest BIS specifications and make proper liaison services forobtaining all necessary permissions. 3. 10 passengers/680 Kg, 3 stops, rated speed adjustable up to 1.0 mtr/sec with 2 years comprehensive maintenance / DLP. [Rate]
228[4.1]Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. [Through Rate]
229[4.11]Deduct for not watering the excavated earth for banking [Through Rate]
230[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
231[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate]
232[4.16.1.1]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.1. All kind of soil Pipes, cables etc, not exceeding 80 mm dia . [Through Rate]
233[4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate]
234[4.17]Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). [Through Rate]
235[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
236[5.11]Demolishing mud phaska in terracing and disposal of material within 50 metres lead. [Through Rate]
237[5.14]Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. [Through Rate]
238[5.23.1]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) [Through Rate]
239[5.26]Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. [Through Rate]
240[5.27]Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. [Through Rate]
241[5.28]Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. [Through Rate]
242[5.29.1]Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1. Of area 3 sq. metres and below [Through Rate]
243[5.30.1]Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1. Of area 3 sq. metres and below [Through Rate]
244[5.36.1]Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of: 1. T or L iron or pipe [Through Rate]
245[5.36.2]Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of: 2. R.C.C. [Through Rate]
246[5.37]Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. [Through Rate]
247[5.41]Removing rolling shutters including top cover, brackets and side guides etc.complete. [Through Rate]
248[5.42]Dismantling cement conglomerate / terrazzo floors 25 mm to 50 mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. [Through Rate]
249[5.43.2]Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 2. For thickness of tiles above 25 mm and up to 40 mm [Through Rate]
250[5.45]Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. [Through Rate]
251[5.46.1]Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : 1. Up to 10 mm thick [Through Rate]
252[5.47.1]Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead : 1. Thickness up to 40 mm [Through Rate]
253[5.48]Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. [Through Rate]
254[5.49]Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. [Through Rate]
255[5.50]Removal of old broken glass panes (any thickness or size, quality or description) from wooden frames, glazed with putty or fixed with beads [Through Rate]
256[5.51]Removing old broken/serviceable glass of any thickness or size or description except polished plate glass from old wood or metal frames etc.(any thickness or size) hacking out old putty etc. including making good breakages in talking out and handling complete [Through Rate]
257[5.52]Dismantling stone-ware drains and of concrete [Through Rate]
258[5.53.1]Removing hume pipes-NP 2/NP 3/NP 4 including excavation and taking out the pipes manually/ by mechanical means and stacking the pipes within standard lead as per direction of Engineer-in-charge 1. up to 600 mm dia [Through Rate]
259[5.54.1]Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 1. 75 to 80 mm dia pipe [Through Rate]
260[5.55.1]Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 1. 15 mm to 40 mm nominal bore [Through Rate]
261[5.56.1]Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 metre lead as per direction of Engineer-in-charge: 1. Up to 150 mm diameter [Through Rate]
262[5.62]Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. [Through Rate]
263[5.63]Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. [Through Rate]
264[5.64.1]Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 1. Up to 150 mm diameter [Through Rate]
265[5.64.2]Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 2. Above 150 mm diameter [Through Rate]
266[5.68.1]Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer-in-charge: 1. Rectangular manhole 90x80 cm and 45 cm deep [Through Rate]
267[5.7.4]Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar [Through Rate]
268[5.70]Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. [Through Rate]
269[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate]
270[6.1.5]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 5. 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) [Through Rate]
271[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]
272[6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) [Through Rate]
273[6.10]Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. [Through Rate]
274[6.13.A]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. A. Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth. [Rate]
275[6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate]
276[6.24.1]Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1. All works up to plinth level [Through Rate]
277[6.24.2]Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]
278[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]
279[6.26.1]Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) [Through Rate]
280[6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. [Through Rate]
281[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate]
282[6.30.16.1]Centering and shuttering including strutting, propping etc. and removal of form for 16.1. Edges of slabs and breaks in floors and walls Under 20 cm wide [Through Rate]
283[6.30.20]Centering and shuttering including strutting, propping etc. and removal of form for 20. Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick [Through Rate]
284[6.30.21]Centering and shuttering including strutting, propping etc. and removal of form for 21. Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick [Through Rate]
285[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
286[6.30.4]Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) [Through Rate]
287[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]
288[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate]
289[6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases [Through Rate]
290[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]
291[6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate]
292[6.38.1]Providing and fixing up to floor four level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) [Through Rate]
293[6.56]Providing and filling in position, blown bitumen in expansion joints. [Through Rate]
294[6.8.1]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 1. 50 mm thick [Through Rate]
295[6.8.3]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 3. 25 mm thick [Through Rate]
296[7.20.1]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
297[7.22.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
298[7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate]
299[7.28.1]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 1. Cement mortar 1:3 (1 cement :3 coarse sand) [Through Rate]
300[7.30]Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. [Through Rate]
301[7.43.2]Brick work with common burnt clay machine moulded perforated non-modular bricks of class designation 12.5 conforming IS : 2222 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 2. Above plinth level up to floor IV level [Through Rate]
302[8.11]Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. [Through Rate]
303[8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. [Through Rate]
304[8.29]Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. [Through Rate]
305[9.10.1]Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. With residual type petroleum bitumen of grade VG -10 [Through Rate]
306[9.12.1]10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow-dung) and covered with machine moulded tile bricks, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat. 1. With machine moulded common burnt clay non-modular brick tiles of class designation 12.5, conforming to IS 2690 [Through Rate]
307[9.13]Extra for every additional 1 cm thickness of mud phaska. [Through Rate]
308[9.14.1]Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 1. With common burnt clay non-modular brick tiles of class designation 10 [Through Rate]
309[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate]
310[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate]
311[9.20]Providing and fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). [Through Rate]
312[9.46.2]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 2. 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) [Through Rate]
313[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate]
314[9.58.1.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.2. Coupler 110 mm [Through Rate]
315[9.59.3]Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 3. 150 mm [Through Rate]
316S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC`s including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. Make:- Schneider/Crabtree/Athena/Anchor/ Havells fabio
317Supply and erection of 3 core PVC copper insulated and sheathed circular flexible wire:- Size 1.50 sq mm (NS)RR FRLS/Havells FRLS/Finolex FRLS
318Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required (NS)600 mmMake:-Orient/Crompton/Havells
319S/E of Automatic ON/OFF of street light controller with digital Astronomical trimer 24 hours , 40-63 amp TPN incomer with AC3 duty contractors, indicators ,A/M switch,IP54 protection ,auto manual operation and 2 amp Fuse for protection of time switch etc complete in all respect with all petty material required to complete the job of satisfaction of EIC.Make:- LandT, Indoasian,ABB
320Supply of 5 MP (2880 x 1620) Dome camera , ONVIF profile S , G and T, M. 1/2.7” Progressive Scan CMOS , 3.6 mm fixed lens , Triple stream with each stream support H.265 compression simultaneously ,min illumination : Color 0.004lux @ F1.2(AGC ON) : B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 20,000 s ,WDR , Compression : H.265/H.264/H.265 plus /H.264 plus /MJPEG . SD card support upto 256GB, Cloud Storage , Built in MIC, frame rate : Main stream should support 25 and 30 fps@ 5MP, Net HDD, ROI Min. 8 Region, Hardware reset, Edge analytics : Face Recognition, Pedestrian and Vehicle Intrusion, Line Crossing, Object Detection, Crossing Counting, Heat Map, Crowd Density, Queue Length, License Plate,Rare Sound Intrusion,Region Entrance, Region Exiting, Defog, Motion Detection, License plate detection. Protocol:-TCP/IP, HTTP, DHCP, DNS, DDNS, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS, FTP, P2P , In built IR LED , IR Distance upto 30 meters , IP 67, POE/12V DC.Approved Makes :Allgovision/ Impulse / Mobotix / Cisco/ Axis
321Supply of 5 MP (2880 x 1620) Bullet camera , ONVIF profile S , G and T, M. 1/2.7” Progressive Scan CMOS ,2.8 mm to 12 mm motorized varifocal lens , Triple stream with each stream support H.265 compression simultaneously ,min illumination : Color 0.004lux @ F1.2(AGC ON) : B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 20,000 s ,WDR , Compression : H.265/H.264/H.265 plus /H.264 plus /MJPEG . SD card support upto 256GB, Cloud Storage , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 and30 fps@5MP, Net HDD, ROI Min. 8 Region, Two Way Audio, Hardware reset, Edge analytics : Face Recognition, Pedestrian and Vehicle Intrusion, Line Crossing, Object Detection, Crossing Counting, Heat Map, Crowd Density, Queue Length, License Plate,Rare Sound Intrusion,Region Entrance, Region Exiting, Defog, Motion Detection, License plate detection. Protocol:-TCP/IP, HTTP, DHCP, DNS, DDNS, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS, FTP, P2P , In built IR LED , IR Distance upto 45 meters , IP 67, POE/12V DC.Approved Makes :Allgovision/ Impulse / Mobotix / Cisco/ Axis
322Supply of 6TB Surviellance Hard Disk. Approved Makes: WD /segate /Toshiba/HP
323Supplying, Installation,Testing and Commissioning of 55 `Professional Display LED /LFDFull HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) Built-in Speaker (10W plus 10W), Magic Clone (to USB), Auto Source Switching and Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling Approved Makes: Panasonic / LG/ Sony/ Samsung
324Supplying, Installation,Testing and Commissioning of Cat6A Patch Cord U/UTP Unshielded 24AWG Bare Copper Stranded Flexible Conductor, HDPE Insulation, Transparent Cross ( plus ) Filler Between Pairs, LSZH Jacket, ANSI/TIA 568C.2 Category 6A, Support 10GBASE-T with Min. 500Mhz Bandwidth, Operating Temperature -20 ? to plus 60 ?, Diameter (= 6.2mm Nominal, No Shield or Barrier Tape Inside, Min. 750 Plug Mating Cycles, Factory assembled with Transparent Premoulded Boots, Length 1 Meter, ETL/NABL Certified.Approved Makes: Derwiser/Nexans/Siemon/Systimax
325Supplying, Installation,Testing and Commissioning of Cat6A Patch Cord U/UTP Unshielded 24AWG Bare Copper Stranded Flexible Conductor, HDPE Insulation, Transparent Cross ( plus ) Filler Between Pairs, LSZH Jacket, ANSI/TIA 568C.2 Category 6A, Support 10GBASE-T with Min. 500Mhz Bandwidth, Operating Temperature -20 ? to plus 60 ?, Diameter (= 6.2mm Nominal, No Shield or Barrier Tape Inside, Min. 750 Plug Mating Cycles, Factory assembled with Transparent Premoulded Boots, Length 3 Meter, ETL/NABL Certified.Approved Makes: Derwiser/Nexans/Siemon/Systimax
326Supply of Cat 6 Patch Cord U/UTP Unshielded 24AWG Bare Copper, Stranded Flexible Conductor, HDPE Insulation, LSZH Jacket, ANSI/TIA 568C.2 Category 6 Patch Cord, Support 1GBASE-T with Min. 250Mhz Bandwidth, Operating Temperature -20 ? to plus 60 ?, Diameter (= 6.0mm Nominal, No Shield or Barrier Tape Inside, Min. 750 Plug Mating Cycles, PC UL94-V-0, Factory assembled with Transparent Premoulded Boots, Length 1 Meter. ETL/NABL Certified.Approved Makes: Derwiser/Nexans/Siemon/Systimax
327Supplying, Installation,Testing and Commissioning of CAT6 24-Port 1U Unloaded Universal Modular Straight Patch Panel preloaded with cable support Bar (with slots to tie individual cable properly at the Support Bar), Stainless Steel Rear Metal Frame, Individual Port Transparent Shutter and Labelling, Preloaded earthing plug for surge protection, UL 1863 Complied, CRC Metal with Black Powder Coated, RoHS Compliant, Individually Replaceable Port IO, (Shuttered IO not recommended, because when shutter gets malfunctioned then entire IO is of no use)Approved Makes: Derwiser/Nexans/Siemon/Systimax
328Supplying, Installation,Testing and Commissioning of fiber Modules 10G BASE Approved Make :Cisco / Juniper / Impulse / Nexxus/Arista
329Supplying, Installation,Testing and Commissioning of Armoured 06 Core Singlemode (OS2) 9/125 Fiber Cable, ITU/T G.652.D, IEC 60794-1 Complied, Outdoor ECCS Armored Fiber Cable with PBT Loose Tube Filled With Thixotropic Jelly, Uni-Tube, 2 Steel Wire Embedded In HDPE Jacket, Water Swellable Tape Under Armor, UV-HDPE Jacket with 1.5mm Thickness, 7.5 plus /- 0.5 mm Overall Diameter, Crush Resistant 2000N/100mm, Tensile Resistant 1000N, Bend Radius : 20 x Cable Diameter, Operating Temperature : -20 to plus 60 Deg C, Max. Attenuation @1310nm and 1550nm : (= 0.35dB/km and (= 0.22dB/km Respectively, Cladding Non-Circularity =1%, Mode Field Concentricity Error =0.6 um, Coating/Cladding Concentricity Error = 12 um, Nominal Weight 65Kg/km, Black ColorApproved Makes: Derwiser/Nexans/Siemon/Systimax
330Supplying, Installation,Testing and Commissioning of Fiber Patch Cord, LC Duplex - LC Duplex, 9/125µm OS2 Singlemode Duplex Zip Cord ((= 2.0mm), IL (= 0.35dB, RL)= 50dB, LSZH Jacket IEC 60332-1, Operating Temperature -40°C to plus 85°C, Meets ANSI/TIA 568.3-D, Length 3Meter Approved Makes: Derwiser/Nexans/Siemon/Systimax
331Supplying, Installation,Testing and Commissioning of 24 Port 1U x 19” LIU Loaded with Singlemode OS2 LC Adapters and LSZH Pigtails along with Splice Trays, Min. 4 No of Circular Cable Entry with Rubber Groummet/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Ties, Panel shall be Powder Coated with Min. 1.2mm Metal Sheath, 30 Years Channel Warranty. Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 ,IEC-60332-1, IEC-60754-1, Insertion loss (= 0.35 dB, Return Loss )= 50, Attenuation: 1310/1550 : 0.3/0.2 dB/KM, Repeatability: (= 0.2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568.3-DApproved Makes: Derwiser/Nexans/Siemon/Systimax
332Supplying, Installation,Testing and Commissioning of 32 channel NVR , ONVIF compliant , Certification CE,FCC,UL,BIS, recording bandwidth 320 Mbps , output interface 1 HDMI (up to 4K), 1 VGA , Alarm in/out :16ch in / 4ch out , 1 X RJ-45 port (1000M) , Bit Rate 16kbps-20mbps per channel, Sync Playback 4/8/10/16 ch playback, iOS smartphone support , 8 HDD support , each HDD slot support upto 8 TB HDD , , 1x3.0 USB for backup /upgrade , 2x 2.0 USB for mouse, 1 E-Sata Port, Cloud Storage, Net HDD, Edge analytics : Customer Flow staistics, Face Attendence, Face Detection and Recognition, Heat Map, Human and Vehicle Detection, Pedestrian Intrusion Detection and Line cross Detection, Queue length detection, Regional population statistics, SOD-Stationaary Object Detection, Deterrence, PIR, Video tampering, AI Registerd Qty- 10000 and AI Captured Qty- 200000. Protocol support:- HTTp, TCP/IP, IPv4, UPNP, RTSP,UDP,SMTP,NTP,DHCP,DNS,IP filter,PPPOE,DDNS,FTP,IP search, P2P, NFS/SMB/CIFS, ONVIF.Approved Make:- Allgovision/ Impulse / Mobotix / Cisco/ Axis
333Supplying, Installation,Testing and Commissioning of 9U Wall Mount Welded/CKD Steel Racks shall be designed for Networking, Servers, Data Centre’s, Audio Video, Telecom and Lab applications.Adjustable 19” equipment mounting verticals provide better mounting flexibility and maximizes the usable mounting space.100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment.: Conforms to DIN 41494 or equivalent ISO standard. Standard Finish should be Powder Coated with Black/Gray colour. Static Load : 30 kgs.Standard Accessories Like Power Distribution Units, Cable Manager, Fans and Mounting hardware. Depth 450/500/600mm Approved Makes: Derwiser/MTS/Rittal/APC/APW
334Supplying, Installation,Testing and Commissioning of 27U Floor Standing Welded/CKD Steel Racks shall be designed for Networking, Servers, Data Centre’s, Audio Video, Telecom and Lab applications.Adjustable 19” equipment mounting verticals provide better mounting flexibility and maximizes the usable mounting space.100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment to conforms to DIN 41494 or equivalent ISO standard.Front Door should be Lockable Toughened Glass Door, Steel Single, Steel Dual. Standard Finish should be Powder Coated with Black colour. Mounting Option : Castor wheels (Front 2 wheels with Break and rear without break) Or Levelers Or Base plinth. Static Load : 30 kgs.Standard Accessories Like Power Distribution Units, Cable Manager, Fans and Mounting hardware. Size Options : 600 x 600 mm / 600 x 800 mm / 600 x 1000 mm / 800 x 1000 mm / 800 x 1200 mm Approved Makes: Derwiser/MTS/Rittal/APC/APW
335Supplying, Installation,Testing and Commissioning of Access switch 24x 1G PoE/PoE plus and 4 x 1/10GSFP plus ports. Should have hot swappable RPS from day 1, Should have AC and DC PSU mix and match arrangement for power source resiliency in the same hardware .Min 370 Watt PoE/PoE plus power budget . Should support 10 Gbps Copper module on SFP plus port for flexibility to utilize. Switching capacity of 168 Gbps, forwarding performance 124 Mpps, should have non blocking architecture, 32 KMAC address. Should have Static Routing, RIP, VRRP, OSPF, OSPFv3, RIP, BFDOSPF, BGP, PBR, ECMP, VRRP from day 1, Should support ISSU from day 1, Should support stacking with min 12 members in a stack (Stacking ports should be exclusive of above mentioned ports), Neighbour discovery, system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP), IPv6 features from day 1, MTBF Min 198000 Hrs. Approved Makes: Cisco/ Nexxus/Juniper / Extreme/Impulse
336Supplying, Installation,Testing and Commissioning of 4x4 Access Point Ceiling Mount having 1 x 2.5GE (PoE/PoE plus ) port , 1 x G Copper port .For 2.4G 2*2 MIMO, For 5G 4*4 MIMO .Built-in omnidirectional internal antennas, Dual frequency with min 6 Stream .For 2.4G: 3dBi and for 5G: 3dBi.200 square meter coverage (without any obstacle).Maximum number of users per band should be minimum 128. power consumption:18W. Encryption: AES, WPA3\802.11i: Supported, Authentication: MAC Address/PSK, Client isolation: Both Layer-2 wireless client isolation and SSID isolation, forwarding security: Packet filter, MAC address filter, and broadcast storm suppression, SSID-VLAN binding: Supported, Management frame protection (802.11w): Supported. Should be CE, FCC, CCC, ROHS certified. Access Points should have option to be managed by cloud infrastructure without replacing the hardware in future required. Approved Make : Cisco / Juniper / Impulse / Nexxus/Arista
337Supplying, Installation,Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz): RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz : Keyboard: 12 function keys: Chassis: Tower/Workstation: DVD: 8X Slimline DVD plus /-RW, Data Only: Dual Graphics Card: Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000: Hard disk: 250GB, 7200 RPM 3.5` SATA 6Gb/s Hard Drive: Operating system: Windows 7 Professional 64 Bit or latest. Approved Makes: HP / DELL / IBM / LENOVO
338S/E of 11 KV Gang operated switch i/c suitable size of copper blade and erection of the same on the existing H pole with the help of channels of size 75x40x6mm ( Heavy Duty )etc.Make Isotech/Rashtriya./Tesla Power
339S/E of fabricated M.S. channel / M.S. angle iron / M.S. flat on PCC poles 11 mtr long as per ISI specifications etc.
340S/E of nut and bolts of all sizes as per IS:1363/1966 nitch screw thread as per ISS:4218/1567.
341S/E of pin insulator polymer type with 11 KV complete on PCC poles of approved make by HVPNL complete in all respects to the entire satisfaction of Engg-in-charge confirming to IS Part-II 1974 and IS : 2486 Part-I 1971 with 150mm threaded portion of 100 mm of GI pin to hold the insulator.
342S/E of stay set complete in all respects with stay wire and disc insulator comprising of MS rod of 18mm dia 1.8 mtr long to withstand 1000Kg load etc.
343S/E of lighting arrestor set for 11 KV disribution system 5 KVA sets IS : 3870/1963
344S/E of LT fuse board with aluminium strip on Acrylic sheet
345Supply, erection of 0.51 mm jelly filled armored telephone cable laid one mtr. below ground level including the cost of digging, bricks, rawl and laying charges, complete in all respect with the entire satisfaction of Engineer-in-charge. (NS)(i) 5 PairMake:- DELTON/ FINOLEX/ HAVELLES
346Supply, erection, laying and testing of D.P. including the cost of krones, base plate, 40mm dia G.I. pipe for incoming and outgoing cable and main box having locking arrangement. (NS)(i) 10 pair DP
347Providing and installation of automatic voltage stabilizer of (heavy duty) copper wound 60 up voltatge complete in all respect. (N.S.)Make:-Voltstar,V-Guard,Microtek
348Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts and bolts etc. of best quality complete in all respect (NS)
349Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS)NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing and laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing and laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring : suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4`) (ii) Gas line:- 15.88mm(5/8`)10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS) Make :Mandev or equivalent
350S/E of surface/wall mounted =20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be = 2000 or above in cool day light (5700K to 6500K), Power factor )0.95, CRI )80, Average life )50000 hours. Complete with mounting Brackets and accessories as required with connections(Industrial)Make: Philips, Havells, Wipro, Bajaj. (NS)
351Supply and erection of 42W Recess 595 X 595 LED Luminaire with housing made up of CRCA for efficient dissipation and diffuser made up of High quality polystyrene opal diffuser to enhance the aesthic of the fixture and to provide glare free uniform light distribution, Powered by an independent output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge Voltage protection and other safety test as per IS:15885 Part 2/Sec 13. Power Consumption not greater than 60W and System Efficacy not less than 121 Lumens/Watt, (5100 lumens) CCT 5700Kand 6500k PF)0.95, CRI)80 ,THD(=10%. LED Average life L70B50: 50000 hours. Operating temperature: -10 °C to plus 40°C , Operating voltage range: 140 V - 270 V,.Make : Havells /phillips/bajaj
352Supply Installation testing and commissioning of microtek Line Interactive UPS with AVR of Rating 0.65 KVA With Warranty of 2 Years for individual computers with battery back up with warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS)
353S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC`s including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. Make:- Schneider/Crabtree/Athena/Anchor/ Havells fabio..
354Providing, supplying, installing, testing, and commissioning of Havells make 1 HP copper-wound, single-phase, self-priming monoblock pump, suitable for 230V, 50Hz AC supply, complete with all standard accessories, including base frame, foundation, nuts and bolts, suction and delivery connections, foot valve, and necessary electrical connections, in all respects as per site conditions and to the satisfaction of the Engineer-in-charge.” Havells, Crompton or equivalent
355Robustt Swing Lid Dustbin - 40L | Silver Stainless Steel Trash Can | 10 Inch (W) x 24 Inch (H) | Swing lid dustbin with removable lid| For Kitchen, Bathroom, Office and Commercial Use - Pack of 1 Type of Bin1 Bin mounted with 2 poleCapacity of each Bin (container) (in Liters):40Material of Pole with stand and container (Bin)Stainless Steel Grade 304Pole diameter (in mm):25-28Pole height (in mm):1000-1099Pole pipe thickness (in mm):1Container wall thickness (in mm):0.8Type of Lid on containerSwing typeFixing accessories provided:Yes
356Supply, installation and Commissionng of addressable fire alarm panel which consists of display board which will have 160 chracter display with touch key pade, motherboard which will have ARM CORTEX M3 32 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the Configuration tools. Two inbuilt programmable inputs, two inbuilt NAC`s and three programmable replays and loop card circuits power supply board, which will have SMPS fully protected board, which its operates on 120 to 220V AC± 10% with 50/60 Hz, battery backup 24V DC with built-in-charger. The panel have IP-50 rating Optional: for BMS integration thru MODBUS converter, Graphical Software, Software for TCP/IP Module, provision for GSM based Auto dialler, provision for printer thru complete module, Apprvoal UL/EN listed only. (NS)Approved Make:- Notifier/Edward/Ravel
357S/I/T/C of Addressable smoke detector with base with base binary coded address setting .Dual LEDs for 360 visibility.Polarity free,sleek low profile housing design.Regular 100mm base ,IP rating-42 ,Approval: UL/EN listed Make:-Notifier/Edward/Ravel/Rux
358Supply, Installation and Commissioning of Response Indicator Alarm status is indicated by Red colour LED, Operates on 12 VDC, Dual LED`s for 360 deg visibility, Flush/Ceiling wall mount, Operating Voltage: 12 VDC, Operating Current: 10 mA, Alarm Indication: RED LED with required accessories. (NS)Approved Make:- Notifier/Edward/Ravel/Bosch
359Supply, Installation and Commissioning of Manual Pull Station Single Action/Dual Action with back box and Break Glass Rod, shall be resettable by Align key to avoid unauthenticated restorations, Addressabel Mini Monitor Module with back box of pull station for monitoring the field NO/NC device. Shall have Binary Coding Setting Dip switch, shall have an LED indication for normal and Activate mode. Approval : UL Listed. (NS)Note: Need to connect with Monitor Module Approved Make:- Notifier/Edward/Ravel/Bosch
360Supply, Installation and Commissioning of Conventional Sounder cum strobe with 24 V DC audiable sound 75 db @ 1 mtr range (16 V DC). It is used for Fire, Burglar and Emergency Alarm System, low current consume @c 47-73 mA Candela : flashing every second, 4 candela setting: 15/30/75/110cd output and 2 different tone audiable sound -UL listed. (NS)Approved Make:- Notifier/Edward/Ravel/Bosch
361Supply, Installation and Commissioning of Fault isolate Base/Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected. (NS)Approved Make:- Notifier/Edward/Ravel/Bosch
362Providing and fixing of CO2 4.5 kg High Pressure Portable Fire Extinguisher, filled with Co2 Gas as per IS 15222, Control discharge mechanism fitted with 1 Meter Wire Braided Hose and Flat Horn with Diffuser Nozzle for dispersed discharge of CO2,Applicable on Class B, C and electrically started Fire, Fire Rating 21B, External coating is of enamel spray painting, Valve Confirm to IS 3224 ISI Marked, CO2 Cylinder construction : hot spinning by seamless pipes and bearing ISI mark, Body confirms to IS 7285 and PESO APPROVED, Extinguishers confirmed to IS 15683:2006 and ISI marked.(NS)Make: SPAGO/SAFEGUARD/MINIMEX/LIFEMAX4.5kg capacity cylinde
363Providing and fixing fire bucket stand fabricated from M.S. Angle 50x50x6 mm complete with canopy made of 18 SWG M.S. sheet, suitable for holding 4 nos. fire buckets of 9.5 kg capacity each, including one coat of red oxide primer and two coats of P.O. red enamel paint of approved quality. The words “MRPL FIRE” shall be painted on both sides of the roof in bold white colour, complete as per specifications and direction of Engineer-in-Charge.
364Supply of 12.5 kg bag of Industrial Fire Sand
365Supply and Installation of G plus 3, SS 304 Grade (German Technology)Door, 800 Center Opening and SS 304Cabin, 10 Passenger Lift, Shaft Size-As per site ,Gearless Machine , and Microcontroller based Main Controller Full collective with ARD Controller, Machine Roomless with Gearless –with music system, LOP, COP, Flooring-PVC, Music. Overload Sensor , with 12 month AMC Make : Surya Tech , Schneider,Kone
366Supply, installation, testing and commissioning of Storage Type Drinking Water Cooler conforming to IS 1475, having cooling capacity of 40 litres/hour and storage capacity of 80 litres, suitable for operation on 230 V, single phase, 50 Hz AC supply, complete with fixed speed compressor, stainless steel storage tank, steel sheet enclosure, and 2 nos. faucets. The unit shall have maximum power consumption of 575 Watts and shall be supplied with all standard accessories, internal piping, insulation, inlet and outlet connections, drain arrangement, mounting arrangement, and required fittings for proper functioning. The work shall include fixing at site, connection with water supply and electrical source, testing, commissioning, and handing over complete in all respects. The drinking water cooler shall be backed by minimum 1-year warranty on complete unit and compressor, along with valid Type Test Report from Central Government Laboratory/NABL/ILAC accredited laboratory confirming conformity to specifications.
367Supply, installation, testing and commissioning of wall mounted Reverse Osmosis (RO) based Water Treatment System having filtration capacity above 50 LPH and up to 100 LPH, suitable for feed water TDS up to 1500 ppm and capable of delivering purified water conforming to IS 10500 standards or better. The system shall consist of SS202 or better RO frame, food grade plastic enclosure, fully automatic control panel with auto cut-off feature, ultraviolet disinfection (UV), ultrafiltration (UF), sand filter, sediment filter and other standard purification accessories complete in all respects.The RO system shall operate on 230V ±10%, single phase power supply and shall be provided with all necessary fittings, valves, internal piping, electrical connections, brackets, screws, supports and accessories required for proper installation and operation. The work shall include neat and secure laying of inlet and outlet piping within 2–3 metres, proper earthing, insulation of wiring, testing, commissioning, training and demonstration to the consignee at site.The item shall be supplied complete with comprehensive warranty of 1 year from the date of satisfactory commissioning including minimum 4 free service visits per year, replacement of pre-filters during service visits, annual replacement of filters/media as applicable, cleaning of complete purification system, and submission of test reports from Government/NABL/ILAC accredited laboratory confirming conformity to specifications. All complete as directed by Engineer-in-Charge.
368Providing, fabricating and fixing individual Stainless Steel (SS) Letters – Grade 302, 0.5~0.8 mm thick, mirror / golden finish, each letter of size 250 mm height, complete in all respects.The letters shall be laser cut, properly finished, buffed and polished to achieve uniform golden appearance. Fixing shall be done with stainless steel studs, fasteners, spacers and chemical anchoring system as required, ensuring proper alignment and firm anchorage to the background surface.The content to be displayed:“HSVP, JIND ”Complete including drilling, template setting, alignment, fixing, and all necessary accessories as per drawings and direction of Engineer-in-Charge.
369Supply of furniture of Geeken , Godrej , Featherlite make/model as approved by Engineer-in-Charge, complete with all accessories, fittings, transportation, loading/unloading and installation at site complete in all respects.3 Seater Sofa With SS Arms and Legs, Perforated Seat and Back, Powder Coated Beam Size in mm - 1750(L) X 710(D) X 755(H) , SS304 ( Magnum 7 - Geeken , Godrej , Featherlite , Godrej , Featherlite )
370Supply of furniture of Geeken , Godrej , Featherlite CAPITAL 1
371Supply of furniture of Geeken , Godrej , Featherlite MERIT
372Supply of furniture of Geeken , Godrej , Featherlite TOKYO 6
373Supply of furniture of Geeken , Godrej , Featherlite GP140
374Supply of furniture of Geeken , Godrej , Featherlite GA 5024
375Supply of furniture of Geeken , Godrej , Featherlite COLUMBIA 1
376Supply of furniture of Geeken , Godrej , Featherlite COLUMBIA 3
377Supply of furniture of Geeken , Godrej , Featherlite DIPLOMAT 3
378Supply of furniture of Geeken , Godrej , Featherlite GMS 42
379Supply of furniture of Geeken , Godrej , Featherlite GMS 10
380Supply of furniture of Geeken , Godrej , Featherlite GMS 22
381Supply of furniture of Geeken , Godrej , Featherlite SHELLY
382Supply of furniture of Geeken , Godrej , Featherlite CARTER
383Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With toughened glass panes of 10 mm thickness (weight not less than 15 kg/sqm)
384M.S. Wheel or roller of steel door orgate and fitting and fixing the same with necessary clamps, nutsand bolts/welding and erection etc. complete.(Wheel of 50 mm dia or above)
3851.5 TR with 5 Star BEE Rating
386Providing and fixing aluminium partition door consisiting of slim profile of required shape and size with frosted glass of 8mm with door handles of 12to 18` annodised black , floor spring door closer and lock of hettich / kazma / RDG complete as per drawing and architeture design. (NS) - Make - Alu arc Providing and fixing fixed window aluminium partition consisiting of slim profile of required shape and size with plain toughned glass 8mm and frosted glass of 8mm complete as per drawing and design. (NS) - Make - Alu arc
387Providing and fixing computer table made of 38 mmthick commercial/BWR grade plywood finished with 1.0 mmthick decorative laminate on all exposed surfaces andbalancing laminate on inner surfaces, including necessaryside panels, top, modesty panel, drawers, shelves, edgebanding, hardware fittings, polishing of exposed edges,complete with all accessories, fixtures, fasteningarrangements, transportation, loading/unloading andinstallation at site complete in all respects. 38 mm thickplywood of Make Greenlam , Century, Acessories of Godrej ,Hettich Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58482684
AUTHORITY Local Bodies
TENDER VALUE 6.64 Crore
LAST DATE 24-11-2026
Authority
Authority Name Haryana Urban Development Authority
Work Description Tender for Construction Of Hsvp Office Complex At Jind (Cm Announcement Code No. 29788 Dated 05.04.2026) Construction Of Hsvp Office Complex Building Including Civil Works, Public Health Work, Electrical Work, Sanitary Installation, Providing And Fixing Office Furniture I.E. Chairs, Tables Etc, Installation Of Air Conditioners, Dismantling Of Existing Structure, Construction Of Boundary Wall Complete In All Respect As Per Satisfaction Of Engineer-In-Charge At Safidon Road Jind And All Other Works Contigent Thereto (Including Three Years Maintenance And Defect Liability Period Free Of Cost).
Basic Detail
Tender No 2026F30D398B E65A 4DE8 915A 4C48F2C9832A259HSV
Bidding Type Tender
Location
City jind
State Haryana
Key Dates
Publish Date 11 Nov 2026
Submission Date 24 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 6.64 Crore
Tender Fee 5000
EMD 13.28 Lakhs
Exemption Available
Document List
18e89a64-b068-41bd-8a97-1ee84222ca43.html
BOQ_639755.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

18e89a64-b068-41bd-8a97-1ee84222ca43.html

xls

BOQ_639755.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender